Loading...
HomeMy WebLinkAboutPA FL13488-R6, skylights'BCIS Home Log In User Registration Hot Topics Submit surcharge Stats & Pacts Publications Contact Us BCIS Site Map Sinks Search �i ` product Approval dopr V USER: Public User Product Approval Menu > Product or Alication Search > A lic�p ation List > Application Detail FL # FL13488-R6 + Application Type Editorial Change Code Version 2017 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sun-Tek Mfg 10303 General Dr Orlando, FL 32824 (407) 859-2117 jfeudneraa sun-tek.com James Feudner engineering@sun-tek.com James Feudner 10303 General Dr Orlando, FL 32824 enginecring@sun-tek.com James Feudner 10303 General Dr Orlando, FL 32824 (407)859-2117 Fxt 111 engineering@sun-tek.com Sky Lights Skylight Certification Mark or Listing National Accreditation & Management Institute National Accreditation & Management Institute Standard AAMA/WDMA 101/I.S.2/NAFS-02 AAMA/WDMA/CSA 101/I.S.2/A440-05 AAMA/ W DMA/CSA/I. S.2/A440-08 Year 2002 2005 2008 Product Approval Method Method 1 Option A Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products I 10/16/2019 10/17/2019 10/22/2019 FL # Model, Number or Name Description 13488.1 CM 2230 CM curb mounted polycarbonate dome .050 (largest size model 2230) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL13486 R6_C CAC CM I010112-R4.1df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Fl_13488 R6__II CM 2230 instal inst.pdf Verified By: James D. Wells, 3r. P.E. 53616 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 13488.2 CM 3046 CM curb mounted .060 polycarbonate dome (largest size model 3046) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No F 11� 3488_R6 C CAC CM 060 NI01011201-R4 pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/31/2021 Design Pressure: +60/-60 Installation Instructions Other: F il. 348$_R6_II_CM 3046instal inst.pdf Verified By: James D. Wells, Jr. P.E. 53616 Created by Independent Third Party: Yes Evaluation Reports Created by independent Third Party: 13488.3 CM 4646 Curb mounted .070 polycarbonate dome (largest size model 4646) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL13488_R6 ,C_CAC CM 070 NI006198-R6.p. ff Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/31/2021 Design Pressure: +60/-60 Installation Instructions Other: F 113348—R6_11_CM 4646 instal inst.Ddf Verified By: James D. Wells, Jr. P.E. 53616 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 13488A CMA 2230 CMA curb mounted aluminum ring .050 polycarbonate dome (largest size model 2230) Limits of Use Certification Agency Certificate Approved for use in HVHZ; No FL1348 R6_C_C�_CMA 050 N1010113-R3.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/31/2021 Design Pressure: +50/-50 Installation Instructions Other: FL13488 R6_II_CMA_223D instal inst.pdf Verified By: James D. Wells, Jr. P.E. 53616 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 13488.5 i CMA 3046 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: f60/-60 CMA curb mounted aluminum ring .060 polycarbonate (largest size model 3046) Certification Agency Certificate FL13488_116 C CAC CMA 060 N1010113.01-R3.odf Quality Assurance Contract Expiration Date 10/31/2021 Installation Instructions Other: FL13488TR6_II_CMA 3046 instal inst .pdf Verified By: James D. Wells, Jr. P.E. 53616 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 13488.6 CMA 4646 GMA curb mounted aluminum ring .070 polycarbonate dome (largest size model 4646) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1 48 _R6_C_CAC CMA 070 NI006226-R6.pA Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/31/2021 Design Pressure. +60/-60 Installation Instructions Other: FL13488_R6_II_CMA 4646 instal inst,pd€ Verified By: James D. Wells, Jr. P.E. 53616 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 13488.7 SF 22230 Self flashing .050 polycarbonate dome (largest size model — 2230) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1348 _.R6_C_CAC_5F 050 N1010111-R4.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/31/2021 Design Pressure: +50/-50 Installation Instructions Other: FL13488_R6 II_SF 2230 instal ins .oddf Verified By: James D. Wells, Jr. P.E. 53616 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 13488.8 SF 3046 Self flashing .060 polycarbonate dome (fargest size model 3046) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FG13488_R6_CCAC_ F 06 NI010 11.01-R5.prO Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/31/2021 Design Pressure: +60/-60 Installation Instructions Other: FL> 3488_R6_II_SF 3046 instal inst.pdf Verified By: James D, Wells, Jr. P.E. 53616 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 13488.9 SF 4646 Self flashing .080 polycarbonate dome (largest size model 4646) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL13488_R6 C_CRC_5F 080 NI009450-R5.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/31/2021 Design Pressure: +60/-60 Installation Instructions Other: FL13488_R6_II F 4646 instal inst.pdf Verified By: James D. Wells, Jr. P.E. 53616 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: 13488.10 5TT Sun-Tek Tube(self flashing) 10", 14", 21" Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL13488_ tB6 C_CAC_5TTNI010115-R6.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 10/31/2021 Design Pressure: +80/-80 Installation Instructions Other: not rated for impact. FL1 488_116 Il 2,22.10 SSTT Final In5tructions.pdf Verified By: James D. Wells, Jr. P.E. 53616 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida, :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. if you do not wish to supply a personal address, please provide the Department with an emall address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval AcceptsTMWIMEIM - Credit Card Safe NOTICE OF PRODUCT CERTIFICATION va GER fiFlCri "7fiD PBO CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI010115-R6 02/11/2010 Structural Sun-Tek 225-1 10/15/2019 To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertificationxom to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAM) if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Sun-Tek Manufacturing, Inc. Series "STT" Self Flashing 10303 General Drive Tubular Skylight Orlando, FL 32824 Configuration: O Polycarbonate: Outer Dome: 0.080" Flat Liner: 0.030" Frame: W-705mm(27.75") H-705mm(27.75") SPECIFICATION PRODUCT RATING AAMAIWDMA/CSA 101/I.S.2/A440-08 Class CW-PG80 1286 x 1286 (28 x 28)-TDD Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3647-7/W-1683 Expiration Date: October 31, 2021 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122