Loading...
HomeMy WebLinkAboutProject info, A-1 200 LEISEN, A-2 200 AMP LEISENBack-up generator system will be a non-separately derived grounding system Ground metallic gas line to generator frame with MIN #6 Green DRAWN CHECKED DATE SCALE JOB NO. SHEET OF 2 SHEETS5818 Lyda laneOrlando Fl. 32839407-816-9000General ContractorQualifer: Mark CrossLicense #: CGC1514240Electrical ContractorQualifer: Mark CrossLicense #: EC13001174REVISIONS BY ELECTRICALPLANINSTALL STANDBY GENERATORFORQUALIFER: MARK CROSS LICENSE # EC13001174 MC 04-16-2020 A-1 CONSTRUCTION TYPE: TYPE OCCUPANCY: SINGLE FAMILY RESIDENCE JURISDICTION: ST. LUCIE COUNTY APPLICABLE BUILDING CODES: •FLORIDA BUILDING CODE, SIXTH EDITION (2017) •FLORIDA ENERGY CODE, SIXTH EDITION (2017) •FLORIDA MECHANICAL CODE, SIXTH EDITION (2017) •FLORIDA PLUMBING CODE, SIXTH EDITION (2017) •EXISTING BLDG. FLORIDA BUILDING CODE, SIXTH EDITION (2017) •FLORIDA ACCESSIBILITY CODE, SIXTH EDITION (2017) •FLORIDA FIRE PREVENTION CODE, SIXTH EDITION •2014 NATIONAL ELECTRIC CODE •NFPA 101 LIFE SAFETY CODE, 2015 EDITION •2013 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS NOTES: IT IS THE CONTRACTOR'S RESPONSIBILITY TO FURNISH AND INSTALL ALL NECESSARY COMPONENTS FOR THE PROPER OPERATION OF ALL SPECIFIED SYSTEMS, REGARDLESS OF WHITHER THOSE COMPONENTS ARE SHOWN ON THE DRAWINGS OR NOT. CONTRACTOR SHALL ALSO VERIFY THAT SPECIFIED COMPONENTS ARE COMPATIBLE WITH OTHERS WITHIN THE SAME SYSTEM ANO WITH THE SYSTEM ITSELF. LEGAL DESCRIPTION: HOLIDAY PINES S/D-PHASE I- LOT 107 (MAP 13/12S) (OR 1510-1862) PARCEL ID #: 1312-500-0108-000-3 PROJECT NO.: G200341 DATE: 7-8-2020 GENERAL ELECIRICAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES AND STANDARDS. 2. THE CONTRACTOR SHALL SATISFACTORLIY REPAIR/REPLACE EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF HIS WORK. 3. APPROVAL SHALL BE OBTAINED FROM THE ENGINEER PRIOR TO CUTTING OR DRILLING ANY STRUCTURAL SUPPORT MEMBER . 4. MINIMUM WIRE SIZE SHALL BE #12 THWN UNLESS OTHERWISE NOTED ON PLANS . 5. ALL CONDUCTORS SMALLER THAN #8 SHALL BE COPPER UNLESS OTHERWISE NOTED ON PLANS . 6. ALL EXPOSED CONDUCTORS SHALL BE RUN IN CONDUIT. 7. ALL MATERIALS SHALL BE U.L. APPROVED. 8. CONTRACTOR SHALL SEAL ALL FIRE RATED PENETRATIONS WITH A FIRE SEALANT EQUAL TO THE RATINGS OF THE PENETRATION. 9. RISERS ARE DIAGRAMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE INSTALLATION 10. THESE DRAWINGS ARE A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 11. ALL CABLES SHALL BE RUN WITHOUT SPLICES. EXCEPT AS OTHERWISE INDICATED. 12. ALL PULL AND JUNCTION BOXES SHALL BE ACCESSIBLE AT ALL TIMES. 13. EXACT POINT AND METHODS OF CONNECTIONS TO EQUIPMENT'S SHALL BE DETERMINED IN FIELD. 14. ALL WORK SHALL BE DONE IN A NEAT ANO WORKMANLIKE MANNER. ALL ELECTRICAL / PLUMBING / MECHANICAL EQUIPMENT SHALL BE ABOVE REQUIRED ELEVATI ON AS PER CHAPTER 11C-5(F)(4) GAS SHALL BE INSTALLED AT LEAST 1 0 FT FROM ANY EXTERNAL SOURCE OF IGNITION (e.g. ELECTRICAL EQUIPMENTS, A/C COMPRESSORS, ETC.) GENERATOR EXHAUST TERMINATION POINT SHALL FBC-R-M1602.2 GENERATOR PACKAGE UNIT OUTLINE SPECIFICATIONS THIS GENERATOR PACKAGE SHALL CONSIST OF A 120/240V, 22 KW, SINGLE PHASE, SOUND ATTENUATED, FULLY PACKAGED, GUARDIAN AIR-COOLED GAS ENGINE GENERATOR SET INCLUDE: BATTERY CHARGING ALTERNATOR MICROPROCESSOR CONTROL FACTORY LOADBANK TESTED 100A MAINLINE CIRCUIT BREAKER SOUND ATTENUATED, WEATHERPROOF ENCLOSURE, 59db @ 23 FEET COMPOSITE MOUNTING PAD UL 2200 LISTED NATURAL GAS OR LP GAS FUEL ELECTRONIC GOVERNOR ENCLOSED CRITICAL GRADE MUFFLER OUTLINE SPECIFICATIONS AUTOMATIC TRANSFER SWITCH 200A, TWO (2) POLES, 120/240 VOLTS, SINGLE PHASE, 22 KAIC. IN A NEMA 3R ENCLOSURE W/ 200A M.C.B, SERVICE ENTRANCE EQUIPMENT RATED A PERMANENT SIGN SHALL BE PLACED AT THE ELECTRICAL SERVICE ENTRANCE EQUIPMENT THAT INDICATES THE LOCATION OF ON-SITE OPTIONAL STANDBY POWER SOURCE. A PERMANENT SIGN SHALL BE PLACED AT THE TRANSFER SWITCH LOCATION INDICATING THE SEQUENCE OF OPERATION TO START THE GENERATOR AND TRANSFER THE ELECTRICAL LOADS. BOND GENERATOR FRAME TO BE GROUNDED PER NEC 250GI FUEL PIPE SHALL BE BONDED AS PER NEC 250.104(B) I I TRANSFER SWITCH IS NON-SEPARATELY DERIVED SYSTEM.ENERATOR FRAME AND GAS PIPE ONLY ALL ELECTRICAL / PLUMBING / MECHANICAL EQUIPMENT SHALL BE ABOVE REQUIRED ELEVATION AS PER CHAPTER 11C-5(F)(4) ( 4) 3/8 DIA. X 3" EXP. ANCHORS OR APPROVED EQUAL one line diagram EXISTING 200 AMP SINGLE PHASE 120/240 VOLT METER NEW 200 AMP SE RATED TRANSFER SWITCH WITH 200 AMP 120/240 VOLT 2 POLE SERVICE RATED BREAKER NEMA 3R EXISTING INTERIOR LOAD CENTER 200 AMP 120/240 VOLT SINGLE PHASE NEMA 1 2 REUSE EXISTING GROUNDING ELECTRODE SYSTEM, CONFIRM SEPERATION OF GROUNDS AND NEUTRALS IN EXISTING LOAD CENTER AND TRANSFER SWITCH SOIL STATEMENT: THE EXISTING SOIL INSPECTED IS SUITABLE FOR SUPPORT OF THE PROPOSED CONSTRUCTION AND THE BEARING CAPACITY OF THE SOILS FOUND MEET OR EXCEED 2000 PSF. ALL ELECTRICAL / PLUMBING / MECHANICAL EQUIPMENT SHALL BE ABOVE REQUIRED ELEVATION AS PER CHAPTER 11C-5(F)(4) (3)-3/8"0 TITEN HD OR EQUIVALENT, 2-3/4" FULL EMBED TO CONCRETE, 3" MIN EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. WIND DESIGN REQUIREMENTS: (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION (2017)) AT-GRADE SIGN METHOD ULTIMATE DESIGN WIND SPEED Vult = 186 mph NOMINAL DESIGN WIND SPEED Vasd = 144 mph RISK CATEGORY= III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY= N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR= 0.85 PRESSURE AT HEIGHT H qh = 77.56 lb/ft2 FORCE COEFFICIENT Cf= 1.44 WIND PRESSURE: P = qh G Cf= 56.80 lb/ft2 (ASD) CONCRETE PAD -----50" --- 4" APPROVED PRECAST PAD PRECAST PAD DETAIL Michael Leisen5902 Nettles Path DriveFt Pierce FL 349513 CONTRACTOR: CODE INFORMATION MARCOPE, LLC 5818 LYDA LANE ORLANDO, FL. 32839 CGC1514240 EC13001174 1 BRAND & MODEL CAPACITY WIDTH LENGTH HEIGHT WEIGHT ALLOWABLE PRESSURE Generac 005871 & 005883 lOKW 25.00" 48.00" 29.00" 387 lbs 41.43 Psf Generac 005872 & 005884 14KW 25.00" 48.00" 29.00" 439Ibs 47.44 Psf Generac 6459, 6461, 6462 16KW 25.00" 48.00" 29.00" 513 lbs 47.44 Psf Generac 006721 16KW 25.00" 48.00" 29.00" 448 lbs 47.44 Psf Generac 005873 & 005885 17 KW 25.00" 48.00" 29.00" 455 lbs 47.44 Psf Generac 005874 & 005886 17 KW 25.00" 48.00" 29.00" 421 lbs 47.44 Psf Generac 005875 & 005887 20KW 25.00" 48.00" 29.00" 451 lbs 47.44 Psf Generac 006729 & 006730 20KW 25.00" 48.00" 29.00" 516 lbs 47.44 Psf Generac 006551 & 006552 22 KW 25.00" 48.00" 29.00" 526 lbs 47.44 Psf Kohler 14RES & 20RES 14-20 KW 26.00" 48.00" 29.00" 500 lbs 47.44 Psf GE 40323GE & 40324GE 13 KW 35.00" 39.40" 39.00" 540 lbs 39.09 Psf GE 040382 15KW 15 KW 33.00" 48.00" 30.50" 484 lbs 43.83 Psf GE 040378 17KW 17 KW 33.00" 48.00" 30.50" 484 lbs 43.83 Psf GE 40330GE & 40331GE 20KW 33.00" 48.00" 30.50" 600 lbs 43.83 Psf Briggs & Stratton 040243-0 lOKW 31.00" 32.00" 34.00" 430 lbs 43.83 Psf Briggs & Stratton 040302-2 12 KW 33.75" 50.00" 31.60" 507 lbs 41.43 Psf Briggs & Stratton 040303-1 15 KW 33.75" 49.00" 31.60" 562 lbs 43.83 Psf Briggs & Stratton 040304-1 18KW 33.75" 49.00" 31.60" 568 lbs 44.00 Psf Briggs & Stratton 040305-1 20KW 33.75" 49.00" 31.60" 570 lbs 44.00 Psf Generac 7035, 7036, 7037 16KW 25.00" 48.00" 29.00" 406 lbs 47.44 Psf Generac 007038 & 007039 20KW 25.00" 48.00" 29.00" 448 lbs 47.44 Psf Generac 007042 & 7043 22 KW 25.00" 48.00" 29.00" 466 lbs 47.44 Psf COMMENTS EXP C 175 MPH & D 156 MPH EXP C 186 MPH & D 156 MPH EXP C 170 MPH & D 156 MPH EXP C 180 MPH & D 156 MPH EXP C 175 MPH & D 156 MPH EXP C 180 MPH & D 156 MPH EXP C 186 MPH & D 156 MPH FEEDER 1 2 FEEDER SCHEDULE FEEDER SIZE Existing 3-#4/0 AL IN 2" PVC or 3-#2/0 CU IN 1 1/2" PVC NEW 3 #1 AL + 1 #6 GD IN 1 1/4" PVC NEW 3-#4/0 AL IN 2" PVC or 3-#2/0 CU IN 1 1/2" PVC FEEDER AS PER NEC TABLE 310.15(B)(6) 3 4 OF