Loading...
HomeMy WebLinkAboutEngineer's LetterPAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 July 15, 2020 Re: Permit# 2001-0494 Re -Roof (Flat Roof Only) 6606 Palomar Parkway. Ft. Pierce, Florida To Whom It May Concern: Our office has personally inspected the Polyglass Self -Adhered Roof System over base sheet ( NOA# 17-1004.09 ) with 11ga. Annular ring shank nails w/ 15/8" tin caps at 8" o.c. in a 4" lap and 8" o.c. in (3) equally spaced staggered rows in the center of the sheet over 19/32" CDX plywood sheathing w/ 8d ring shank nails @ 4" o.c. perimeter and 6" o.c. in the field over existing 2x4 roof members @ 24" o.c. at the above referenced address and find that all work meets the FBC and FRC 2017, 6th Edition and our engineering requirements and we recommend approval of same. Thank you for your attention to this matter. Sinc ely: PAU WELCH INC. Paul etch, P.E. Fla. R g. No. 29945 PW:ns