Loading...
HomeMy WebLinkAboutNOArcouk��] DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Gulf Coast Supply & Manufacturing LLC. 4020 SW 4491" St. Horseshoe Beach, FL. 32648 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786)315-2590 a m.miamidade.eov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 26 ga. GulfLok Roof Panel over 15/32" Plywood deck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. t4 FrrodsP µ7ao93te AUG q tp TL!/ Reviewed tot design nHUl7 � 7 L�IJ FILE //''��� Gr NOA No.: 14-0520.03 nwt umi n, ce Copy Expiration Date: 04/30/20 Approval Date: 04/30/15 Page 1 of 6 ROOFING SYSTEM APPROVAL: Category Roofing Sub -Category: Metal, Panels (Non -Structural) Material: Steel Deck Tyne: Wood Maximum Design Pressure -161 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specifications Description 26 ga. GulfLok Roof Length: various TAS 110 26ga. Steel, Flouropan Coated, snap lock panel. Panel Height: 7/8" Width: 16" (coverage) Thickness: 26ga. (0.0179") Panel Clip Length: 24" TAS 110 Corrosion resistant, 24 gauge steel clip. Width: 1-3/4" long base Thickness 24 ga TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS: Test Product Product Specifications Description Manufacturer Titebond WeatherMaster TAS 132 Sealant formulated to be used with Franklin International Metal Roof Sealant metal roof sytems MANUFACTURING LOCATION: 1. Horseshoe Beach, FL. 2. Sebring, FL. 3. Stuart, FL. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials VLS-004-02-01 ASTM G155 02/22/13 Technologies VLS-005-02-01 ASTM B 117 02/22/13 Architectural Testing B9000.01-450-18 TAS 125 12/12/12 Farabaugh Engineering and Testing T356-I OA TAS 100 07/18/13 Force Engineering and Testing, Inc. 117-0301T-I OA-C TAS 125 07/26/13 NOA No.: 14-0520.03 Expiration Date: 04/30/20 Approval Date: 04/30/15 Page 2 of 6 APPROVED ASSEMBLIES: System: 26 ga. GulfLok Roof Panel, 16" Wide Deck Type: Wood, Non -insulated Deck Description: New Construction "/32" or greater plywood or wood plank, or for re -roofing 15/32" or greater plywood. Slope Range: 2": 12" or greater Maximum Uplift See Table A below Pressure: Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d annular ring shank nails spaced 6" o.c. In reroofing, where the deck is less than "/32" thick (Minimum 15/32") The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 ''/d' annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll or any approved underlayment having a current NOA. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in Gulf Coast Supply and Manufacturing LLC's Installation Manual. 18" wide layer of a Miami -Dade approved self -adhered underlayement membrane shall be applied on each side of the valley. Metal Panels and Install the "26 ga. GulfLok Roof Panel' including flashing penetrations, valleys, end laps Accessories: and accessories in compliance Gulf Coast Supply and Manufacturing LLC's current, published installation instructions and in compliance with the minimum requirements detailed in Roofing Application Standard RAS 133. Panels shall be secured in the flange along the male rib through every precut slot (5-3/16" o.c.) with corrosion resistant #10-12 pancake head fasteners of sufficient length to penetrate through the sheathing a minimum of 3h6". For Perimeter and Comer Option 42, the Panel Clip shall be placed over the male rib prior to securing the panel. Fasteners shall penetrate the clip and go through the precut slot in the male flange of the panel. The female rib of panel is installed over the male rib of panel. For Perimeter and Corner Option #1, a continuous 3/8" bead of Titebond Weathermaster is placed between the screw strip and the male vertical leg. Refer to Table A for maximum design pressures. NOA No.: 14-0520.03 Expiration Date: 04/30/20 Approval Date: 04/30/15 Page 3 of 6 TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Option #1 Perimeter and Corner' Option #2 Maximum Design Pressures -63.5 psf -121.75 psf -161 psf Fastener Spacing 5-'1,6" O.C. 5 3/16" O.C. V/16" O.C. Sealant No Yes No Panel Clip No No Yes 1. Extrapolation shall not be allowed LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133. 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Cade and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 14-0520.03 Expiration Date: 04/30/20 Approval Date: 04/30/15 Page 4 of 6 PROFILE DRAWINGS GULFLOK PANEL ccxnvxis �uxoff s6urxr 'PACM Evens§ PWAMCMEM ATTACH MOT PERIMETER AND CORNER OPTION #1 SEALANT PLACEMENT DETAIL MIAMI•DADE COUNTY .... NOA No.: 14-0520.03 Expiration Date: 04/30/20 Approval Date: 04/30/15 Page 5 of 6 R F?aa1.]i a : U:� PERIMETER AND CORNER OPTION #2 PANEL CLIP PLACEMENT DETAIL Ni- 24GA. CORNER CLEAT 1-I4• �V� PANEL CLIP DETAIL END OF THIS ACCEPTANCE NOA No.: 14-0520.03 Expiration Date: 04/30/20 Approval Date: 04/30/15 Page 6 of 6