HomeMy WebLinkAboutEvaluation ReportDIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES
SECTION: 0616 00—SHEATHING
DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION
SECTION: 07 25 00—WATER-RESISTIVE BARRIERS/WEATHER BARRIERS
jDo.��OFo SECTION: 07 27 00—AIR BARRIERS
b
7�P'F
REPORT HOLDER:
HUBER ENGINEERED WOODS, LLC
EVALUATION SUBJECT:
ZIP SYSTEM"" WALL SHEATHING
ICC ICC ICC
"2014 Recipient of Prestigious Western States Seismic Policy Council
(WSSPC) Award in Excellence"
A Subsidiary of
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any of r e''�� s c t lly
addressed, nor are they to be construed as an endorsement of the subject of the report or �redFtfan or its use.
There is no warranty by iCC Evaluation Service, LLC, express or implied as to arty finding or other matter in this
report, or as to any product covered by the report.
eiow
Copyright ® 2018 ICC Evaluation Service, LLC. All rights reserved.
ICC-ES Evaluation Report ESR-1474
Reissued October 2018
This report is subject to renewal October 2020.
www.icc-es.ora 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 06 00 00—WOOD, PLASTICS AND
COMPOSITES
Section: 0616 00--Sheathing
DIVISION: 07 00 00—THERMAL AND MOISTURE
PROTECTION
Section: 07 25 OD —Water -resistive Barriers/Weather
Barriers
Section: 07 27 00--Air Barriers
REPORT HOLDER:
HUBER ENGINEERED WOODS, LLC
EVALUATION SUBJECT:
ZIP SYSTEM® WALL SHEATHING
1.0 EVALUATION SCOPE
Compliance with the following codes:
■ 2015, 2012 and 2009 International Building Code (IBC)
■ 2015. 2012 and 2009 International Residential Code®
(IRC)
■ 2015, 2012 and 2009 International Energy Conservation
Cade (IECC)
For evaluation of compliance with codes adopted by the
Los Angeles Department of Building and Safety (LADBS),
see ESR-1474 LABC and LARC Supplement.
Properties evaluated:
■ Weather resistance
■ Air leakage
2.0 USES
ZIP System Wall Sheathing panels are used as
combination wall sheathing, air barrier, and water -resistive
barrier. This report recognizes the use of ZIP System
Sheathing, when installed with ZIP SystemThl flexible
flashing seam tape, in walls of Type V construction (IBC)
and dwellings under the IRC, and as an alternate to the
water -resistive barrier required in Chapter 14 of the IBC
and Chapter 7 of the IRC, and to the air barrier required by
Sections R402.4 and C402.5.1 of the 2015 IECC (Sections
R402.4 and C402.4.1 of the 2012 IECC; Sections 402.4.1
and 502.4.3 of the 2009 IECC).
3.0 DESCRIPTION
3.1 Sheathing Panel:
The ZIP System Wall Sheathing panel is an OSB wood
structural panel having a laminated exterior facer. The
Exposure 1 OSB complies with US DOC PS 2 for wood
structural panels. The exterior facer is a medium -density,
phenolic4mpregnated, polymer -modified sheet material
qualifying as a Grade D water -resistive barrier (required by
Section 2510.6 of the 2015, 2012 and 2009 IBC). The
panels are nominally 4 feet wide by 8, 9, 10. 11 or 12 feet
long and have a square -finished -edge or machined -edge
profile.
When tested in accordance with ASTM E96 (water
method), the polymer -modified sheet overlay has a
minimum vapor permeance of 12 perms [68.6 X
10-11 kg/(Pa-s-m2)]. Equivalent Water Vapor Transmission
rate (WVT) of the polymer -modified sheet overlay is
83.4 g/(24h-m2) when tested at 73.4°F (23°C).
The water -resistive barrier and air barrier properties of
the ZIP System® Wall Sheathing Panels are not affected
when the panels are manufactured to comply as facing
materials for SIPS in accordance with Section R610.3.2
and Table R610.3.2 of the 2015 IRC (Section R613.3.2
and Table R613.3.2 of the 2012 and 2009 IRC).
3.2 Seam Tape:
The ZIP SystemThl seam tape is a self -adhering membrane
tape consisting of acrylic adhesive laminated to a
polyolefin backing. The tape is 0.012 inch (0.30 mm) thick
with a minimum width of 3 /4 inches (95.2 mm), and comes
in rolls of various lengths.
4.0 INSTALLATION
4.1 General:
Installation of ZIP System® Wall Sheathing panels must
comply with the applicable code, this report and the
manufacturers published installation instructions. The
manufacturers published installation instructions must be
available at the jobsite during installation.
4.2 Application:
4.2.1 General: The ZIP System® Wall Sheathing panels
must be attached to wall framing in accordance with the
applicable code for wood structural panels, and in
compliance with their panel span rating. The panels must
be installed with the polymer -modified sheet overlay
facing the exterior. In accordance with the manufacturers
published installation instructions, it is recommended that
the square edges of the panels be installed with a gap
between adjacent panels and between panels and
dissimilar materials. All ZIP Systeme Wall Sheathing panel
seams must be sufficiently sealed with ZIP System seam
tape. All overlay surfaces must be dry and free of sawdust
and dirt prior to application of the ZIP System- seam tape.
ICC-ES Evalmtion Reporu are not to be construedas representing aesthettcs or arty other atmthuts, not spec fmQy addressed, nor are they to be construed
m m endomement ufthe subject of the repurt ora rero endation for its we. Thereis no warranry by ICC Evaluaaun Servtre, LLC, evpms or implied, as
to mryftndingor uther matter in this report, or as to airy product morred by the report.
copyright 0 2018 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 9
ESR-1474 I Most Widely Accepted and Trusted Page 2 of 9
The ZIP SystemT°" seam tape must extend a minimum of
1 inch (25.4 mm) past the panel edge T-joint intersections
and must be centered within '/2 inch (12.7 mm) over the
middle of panel seams. The tape must be pressed firmly to
adhere to the surfaces and seal the seams. Wrinkles in
the ZIP SystemTM seam tape are acceptable unless they
create a leak path to the panel seam.
4.2.2 Flashing: Flashing complying with the applicable
code must be installed at the perimeter of door and
window assemblies, penetrations and terminations of
exterior wall assemblies, exterior wall intersections with
roofs, chimneys, porches, decks, balconies, and similar
projections, and at built-in gutters and similar locations
where moisture could enter the wall. An adhesive -backed
flashing tape recognized in a current [CC -ES evaluation
report must be installed to seal all ZIP System Wall
Sheathing flashing joints. Penetration items must be
sealed to the panels. The adhesive -backed flashing tape
must comply with the ICC-ES Acceptance Criteria for
Flexible Flashing Materials (AC148) and must be installed
in accordance with the manufacturer's published
installation instructions. See Figures 1 through 7 of this
report for typical flashing, water -resistive barrier and air
barrier assembly installation details.
4.2.3 Air Barrier Assembly: ZIP System Wall
Sheathing fastened to maximum 24-inch-on-center
(610 mm) wood wall framing, using minimum 6d nails
spaced at 6 inches (152 mm) around panel edges and at
12 inches (305 mm) in the field, leaving a '/8-inch
(3.18 mm) gap between panels, forms an air barrier
assembly when the gaps between panels and the
perimeter of penetrations are sealed with ZIP SystemT
seam tape as required by Section 4.2.1. The assembly has
demonstrated a maximum air leakage of 0.0072 cfm/ft2
[0.037 L/(s•m2)1 infiltration and 0.0023 cfrn/ft2
[0.012 L/(s•m2)] exfiltration at a pressure differential of
1.57 psf (75 Pa) when tested in accordance with
ASTM E2357.
5.0 CONDITIONS OF USE
The ZIP System Wall Sheathing panel and tape system
described in this report complies with, or is a suitable
alternative to what is specified in, those codes listed in
Section 1.0 of this report, subject to the following
conditions:
5.1 This evaluation report and the manufacturer's
published installation instructions, when required by
the code official, must be submitted at the time of
permit application.
5.2 The ZIP System® Wall Sheathing panels must be
manufactured, identified and installed in accordance
with this report and the manufacturer's published
installation instructions. In the event of a conflict
between the instructions and this report, this report
must govern.
5.3 The ZIP System Wall Sheathing panels must be
covered with a code -complying exterior wall covering,
or one that is recognized in a current ICC-ES
evaluation report
5.4 The OSB sheathing must comply with US DOC PS-2.
5.5 Fire -resistance -rated construction is outside the
scope of this report.
5.6 The Zip System Wall Sheathing panels are
manufactured by Huber Engineered Woods, LLC, in
Crystal Hill, Virginia; Easton, Maine; Commerce,
Georgia; Broken Bow, Oklahoma; Spring City,
Tennessee: and Shawinigan, Quebec Canada, under
a quality -control program with inspections by ICC-ES.
6.0 EVIDENCE SUBMITTED
6.1 Data in accordance with the ICC-ES Acceptance
Criteria for Water -resistive Membranes Factory -
bonded to Wood -based Structural Sheathing, Used as
Water -resistive Barriers (AC310), dated May 2008
(editorially revised August 2015).
6.2 Air leakage data in accordance with ASTM E2357.
7.0 IDENTIFICATION
7.1 Each ZIP System Wall Sheathing panel described in
this report must bear a label that includes the
manufacturers name (Huber Engineered Woods
LLC), the product name, nominal panel thickness, the
evaluation report number (ESR-1474), and the words
"Mill 229, Crystal Hill, Virginia"; "Mill 228, Easton,
Maine"; "Mill 227, Commerce, Georgia"; "Mill 290,
Broken Bow, Oklahoma", "Mill 230. Spring City,
Tennessee", or "Mill 390, Shawinigan, Quebec
Canada." The OSB sheathing must also bear a label
demonstrating compliance with US DOC PS 2 from
an approved inspection agency. The ZIP System'
seam tape roll must be labeled with the ZIP System
logo and the evaluation report number ESR-1474
(see Figure 8).
7.2 The report holders contact information is the
following:
HUBER ENGINEERED WOODS, LLC
ONE RESOURCE SQUARE
10925 DAVID TAYLOR DRIVE, SUITE 300
CHARLOTTE, NORTH CAROLINA 28262
(800)933-9220
www.huberwood.com
ESR-1474 I Most Widely Accepted and Trusted
3of9
MMDE
iNME
�m MczS
PGLMI ANE
mjw
wcI�EAMG
C MG
NEfA Mom
BY FLASNMG
14WIh NRER
FI/SNmmDP
sWAIL
SILL SECTION
JAMB SECTION
FIGURE 1—TYPICAL CROSS SECTIONS OF FLANGED WINDOW
ESR-1474 I Most Widely Accepted and Trusted Page 4 of 9
� :,sma•
wall �FATIx6
PLN♦71E-2WJRD
P-lN` N4 L1PE Ftll(il F2WSE
GLLUFS
ION—AF9JnE
PCJ�FSTHAIIE
ILAfN
Intro xuo =
CUPIlIE Ca$ �tVTIMa'NFiD
SILL SECTION HEADER SECTION
WLNOOW JAMB
ZP SYSTEM
ADHESIVE —BACKED WALL SHEALHING
FLASHING TAPE
OUTSIDE CAULKING
ROUGH OPENING
INSIDE
LOW—PRESOURE
POLWRETHANE FOAM
JAMB SECTION
FIGURE 2—TYPICAL CROSS SECTIONS OF INSTALLED BRICK MOLD WINDOW
ESR-1474 I Most Widely Accepted and Trusted Page 5 of 9
ZIP SYSTEMTM
WALL SHEATHING
WALL FRAMING
ADHESIVE -BACKED FLASHING TAPE
METAL FLASHING
- FLASHING FASTENER
ADHESIVE -BACKED FLASHING TAPE
ROOF UNDERLAYMENT (FELT)
/ ROOF SHEATHING
ROOF JOIST
FIGURE 3-ROOF-WALL INTERSECTION (OPTION 1)
FIGURE S—TYPICAL WALL -SILL INTERSECTION
AND FLASHING DETAILS FOR BRICK SIDING
ZIP SYSTEM T.M
WALL SHEATHING
WALLFRAMING
ADHESIVE -BACKED FLASHING TAPE
FLASHING FASTENER
COUNTER FLASHING
BASE FLASHING
FLASHING FASTENER
ADHESIVE -BACKED FLASHING TAFE
�ROOF UNOERLAYNENT (FELT)
i-ROOF SHEATHING
ROOF JOIST
FIGURE 4—ROOF-WALL INTERSECTION (OPTION 2)
FIGURE 6—TYPICAL WALL -SILL INTERSECTION
AND FLASHING DETAILS FOR LAPPED SIDING
ESR-1474 I Most IMdelyAccepted and Trusted Page 6 of 9
Adhesive -Backed
FIGURE 7—INSTALLATION AT PENETRATION OPENING (NON -FIRE -RESISTANCE RATED)
FIGURE 8—LABELING FOR THE LP SYSTEM- SEAM TAPE ROLL
IMES Evaluation Report ESR-1474 LABC and LARC Supplement
Reissued October 2018
This report is subject to renewal October 2020.
www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES
Section: 06 16 OD —Sheathing
DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION.
Section: 07 25 00—Water-resistive Barriersi eather Barriers
Section: 07 27 00—Air Barriers
REPORT HOLDER:
HUBER ENGINEERED WOODS, LLC
EVALUATION SUBJECT:
ZIP SYSTEM® WALL SHEATHING
1.0 REPORT PURPOSE AND SCOPE
Purpose:
The purpose of this evaluation report supplement is to indicate that the ZIP System® Wall Sheathing, described in ICC-ES
master evaluation report ESR-1474 has also been evaluated for compliance with the codes noted below as adopted by the
Los Angeles Department of Building and Safety (LADES).
Applicable code editions:
■ 2017 City of Los. Angeles Building Code (LABC)
■ 2017 City of Los Angeles Residential Code (LARC)
2.0 CONCLUSIONS
The ZIP Systems Wall Sheathing, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474complies
with the LABC Chapter 14, and the LARC Section R703, and is subject to the conditions of use described in this
supplement
3.0 CONDITIONS OF USE
The ZIP System Wall Sheathing, described in this evaluation report must comply with all of the following conditions:
■ All applicable sections in the master evaluation report ESR-1474.
■ The design, installation, conditions of use and identification are in accordance with the 2015 International Building Code®
(2015 IBC) provisions noted in the master evaluation report ESR-1474.
■ The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, as
applicable.
This supplement expires concurrently with the master report, reissued October 2018.
ICC-ES Evalwnon lleporm are nai to be comimed as represenbng aesihetas or any other aunbutes not specifically addressed, mram theyto be conamed
as an endocremeni of the subject of the report are recammendutian for ite urc. There is no warranty by f('C Eiis aalion Service, LLC. express or Implied, as 'u
to anyfinding or other matter in this reparp orm to airy pnnluct covered by the report
Copyright ® 2018 ICC Evaluation Service, LLC. All rights resemed. Page 7 of 9
ICC-ES Evaluation Report ESR-1474 CBC and CRC Supplement
Reissued October2018
This report is subject to renewal October 2020.
www.icc-es.orq 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES
Section: 06 16 00—Sheathing
DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION
Section: 07 25 00—Water-resistive Barriers/Weather Barriers
Section: 07 27 00—Air Barriers
REPORT HOLDER:
HUBER ENGINEERED WOODS, LLC
EVALUATION SUBJECT:
ZIP SYSTEM° WALL SHEATHING
1.0 REPORT PURPOSE AND SCOPE
Purpose:
The purpose of this evaluation report supplement is to indicate that ZIP System® Wall Sheathing, recognized in ICC-ES
master evaluation report ESR-1474, has also been evaluated for compliance with the codes noted below.
Applicable code editions:
■ 2016 California Building Code (CBC)
■ 2016 California Residential Code (CRC)
2.0 CONCLUSIONS
2.1 CBC
The ZIP System® Wall Sheathing, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, complies
with CBC Chapter 14, provided the design and installation are in accordance with the 2015 International Building Code
(2015 IBC) provisions noted in the master report and the additional requirements of the CBC Chapters 14, 16, 16A, 17, 17A
and 23, as applicable.
2.2 CRC
The ZIP System® Wall Sheathing, as described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474
complies with the CRC, provided the design and installation are in accordance with the 2015 International Residential Code
(2015 IRC) provisions noted in the master report.
The ZIP System® Wall Sheathing recognized in this supplement has not been evaluated for compliance with the
International Wildland-Urban Interface Code".
This supplement expires concurrently with the master report, reissued October 2018.
ICC-ES Evaluation Reports arc not to be cmrzuved m ri prnemnigaertheticr or any other atmbutes not spec fwily addressed, norms, they to be construed
os an eadonemear of the subject of the report or a mcommendmton jar its use. There is no warranty by IC'C Evaluation Service, LLC express or implied, as Z
to anyfnding or other miter in this report, or m to anypruduct covered by the mpon.
Copyright® 20181CC Evaluation Service, LLC. All rights reserved. Page 8 of 9
ICC-ES Evaluation Report ESR-1474 FBC Supplement
Reissued October2018
This report is subject to renewal October 2020.
www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES
Section: 06 16 OO—Sheathing '
DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION
Section: 07 25 00—Water-Resistive BarrierslWeather Barriers
Section: 07 27 00—Air Barriers
REPORT HOLDER:
HUBER ENGINEERED WOODS, LLC
EVALUATION SUBJECT:
ZIP SYSTEM® WALL SHEATHING
1.0 REPORT PURPOSE AND SCOPE
Purpose:
The purpose of this evaluation report supplement is to indicate that ZIP System Wall Sheathing panels, recognized in
ICC-ES master evaluation report ESR-1474, have also been evaluated for compliance with the codes noted below.
Applicable code editions:
■ 2017 Florida Building Code —Building.
■ 2017 Florida Building Code —Residential
2.0 CONCLUSIONS
The ZIP System® Wall Sheathing panels, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474,
comply with the Florida Building Code —Building and the Florida Building Code —Residential, provided the design and
installation are in accordancewith the 2015 International Building Code provisions noted in the master report.
Use of the ZIP System Wall Sheathing panels for compliance with the High -Velocity Hurricane Zone provisions of the
Florida Building Code —Building and the Florida Building Code —Residential has not been evaluated, and is outside the
scope of this evaluation report.
For products falling under Florida Rule 9N-3, verification that the report holder's quality assurance program is audited by a
quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the
responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by
the Commission).
This supplement expires concurrently with the master report, reissued October 2018.
XC-ES Evaluation Reports are nut robe construed as ®presenting aesthetics or any other attributes not specifically addressed nor are they to be construed
man endarsement of the subject of the report or a recommendation fur its use. Thee,., on x armnry by lC'C' Evalumma Service, LLC. esp. or otphod, ar Y
to anyftnding or other matter in this report, or m to any product covered by the report
Copyright® 20181CC Evaluation Service, LLC. All rights reserved. Page 9 of 9