Jose Gil PE Approved 07.14.2020
PLAN KEY PV -1 COVER PAGE PV -2 SITE PLAN PV -3 PANEL SPECIFICATION PV -3.1 PANEL LOAD TESTING RESULTS PV -3.2 INVERTER SPECIFICATION PV -3.3 COMBINER BOX SPECIFICATION PV -3.4 JUNCTION BOX SPECIFICATION PV -3.5 ATTACHMENT DETAIL PV -3.6 STRUCTURAL CALCULATION PV -3.7 SEALANT SPECIFICATION PV -3.8 SEALANT SPECIFICATION CONT. PV -3.9 CONDUIT SUPPORT SPECIFICATION PV -4 THREE LINE DIAGRAM PV -4.1 ELECTRICAL NOTES PV -4.2 EQUIPMENT LABELS PV -5 STRUCTURAL CERTIFICATION BUILDING INFORMATION/B.O.M. # STORIES 1/15 ROOF AREA 2788.168457 P.V. AREA 577 ROOFING TYPE ASPHALT SHINGLES ROOF PITCH 19 # RAILS 27 # L -FOOT ATTACHMENTS 66 # MODULES 32 # INVERTERS 32 # SKIRTS 12 # ENPHASE COMBINER BOXES 1 EATON 60A FUSIBLE SOLAR AC DISCONNECT 1 SOA FUSES 2 125A LINE TAPS 2 LG LG 350N1C-V5 350 WATT MODULE 6.6-.41'X 40" X 1.57" EE DATASHEET) GENERAL NOTES: THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, 6TH EDITION 2017 FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 FLORIDA BUILDING CODE, 6TH EDITION 2017 FLORIDA FIRE PREVENTION CODE, NEC 2014 AND ALL LOCAL CODES & ORDINANCES. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6 -INCHES ABOVE THE SURFACE OF THE ROOF FOR SLOPED ROOF AND NO MORE THAN 10 -INCHES ABOVE THE SURFACE OF THE ROOF FOR FLAT ROOF. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. ALL DESIGN, CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK REGISTERED ARCHITECT. FLORIDA STATE STATUTE 471.003(3) PROVIDES THAT LICENSED ARCHITECTS ARE EXEMPTED FROM THE PROVISIONS OF CHAPTER 471 ENGINEERING AND NOT PRECLUDED FROM PERFORMING ENGINEERING SERVICES FOR INTEGRATED SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO THE DESIGN CONSTRUCTION OR ALTERATION OF BUILDINGS AND STRUCTURES FOR HUMAN HABITATION. momentum0 SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING :• o PE86753 �O*••. STATE OF '•��� I SOLAR CONTRACTOR CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION JOSE GIL - MS52684 INVERTER PLACEMENT: 6306 EMERSON AVE FORT PIERCE, FL 34951 SYSTEM UTILIZES "ENPHASE" MICRO -INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE (772) 332-8075 OF EACH MODULE. PV SYSTEM INFORMATION SYSTEM SIZE (DC): 11.2 KW STRUCTURAL STATEMENT: 32 MODULES: LG LG 350N1C-V5 32 INVERTERS: ENPHASE THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE IQ7PLUS-72-2-US SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 6TH EDITION 2017 FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 FLORIDA BUILDING CODE SECTION 1512 THROUGH 1525 AND PROJECT INFORMATION SECTION 1616 THROUGH 1626 FOR HIGH VELOCITY HURRICANE ZONES. INITIAL DATE: 7/14/2020 DESIGNER: SN FSEC CERTIFICATION STATEMENT: REV' DATE: DESIGNER: PER FL. STATUE 377.705 (REVISED 7/1/2017), I, MINA A. MAKAR PE# 86753, Certificate of Authorization #33404, REV' DATE: DESIGNER: AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND COVER PAGE ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2017 PV -i W U LU z W a Z w O Ln & CC LL 0 L z 2 SITE PLAN 21'-4" 25'-6" 25'-2" 4'-9" 3'-2" G) c A X 6) c I X ROOF PANEL COUNT TILT ,� 1T-2" 10'-72" R1 29 19e 4-9 4-911 4-9 4-9„ 4,_91 4'-9” R2 3 180 PZ3IT a a PZ�3� PZ3 PZ PZ3 4'-9" e PZ2_1 I o �eJ eol I, PZ1 k PZ21 oG W 27'_ 2„ • ��- 1 PZ1 1 �o of I PZ2 I PZ2- 1 M . j J m PZ2 I \ PZ °l 1 1 I-- I—`% � \\ PZ2 1 PZ I L41-91' - I ISI I PZ2 1 I PZ2 1 j 1 PZ2 I I 1 / PZ2o i Pzl I I PZ2 ° O j 10 1 1 PZ2 .. e p 10 1 rn NPzl 1 PZ2 0 0 e e� 1 PZ3 41_911 R2 R1 .0 e o °� I PZ2 4'-9" PZ2 .., �PZ i PZ Pz PZ2 C7 e- o • e I I Boxl ) J 4'-9" 1 IPZ3 PZ3Lp PZ31 4'-9" 4'-9" 4'-9" 4'-9" 4'-9" 17'-2" 10'-7Z" 3'-2" � MSP OLAR O AC C 22'-10" 21'-8Z" RAFTER SPACING 24" O.C. (TYP) B SCALE: 3/32" = 1'-0" DISC NOTE: ELECTRICAL EQUIPMENT 1. ROOF COVERING MATERIAL IS COMPOSED OF ASPHALT SHINGLES 2. EXACT ATTACHMENT LOCATION AND QUANTITY OF ATTACHMENTS ARE BASED ON EXISTING RAFTER LOCATIONS OBTAINED FROM FIELD MEASUREMENTS.. THE LOCATION AND QUANTITY OF ATTACHMENTS MAY VARY BASED ON RAFTER LAYOUT START POINT, SPACING VARIATIONS AND ROOFING TYPE. VERIFY IN THE FIELD ALL RAFTER LOCATIONS AND ADJUST LAYOUT AS REQUIRED. A TILE ROOF WILL PRODUCE A STAGERED ATTACHMENT LAYOUT BECAUSE OF EXISTING STAGERED TILE JOINT LOCATIONS 3. EXISTING RESIDENCE EQUIPPED WITH SMOKE/CO DETECTOR IN AND OUTSIDE OF ALL SLEEPING ROOMS HARDWIRED AND INTERCONNECTED AS PER FEDERAL LAW AZIMUTH SHADING 270° 95% momentum 900 78% SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING CLAMPING MAX SPACING IN ZONE 1 72" O.0 AND IN ZONE 2 AND ZONE 3 48" O.0 SYMBOL LEGEND MSP MAIN SERVICE PANEL SP SUB -PANEL REV: UTILITY METER MIN 3'x3' GROUND ACCESS REV: ou AC DISC SOLAR ACDISCONNECT UDC UTILITY DISCONNECT LC LOAD CENTER N3R NEMA 3R BOX W/ ENVOY -S CB COMBINER BOX MODULE 0 I PIPE VENT (—I—J FAN \� SATELLITE DISH A. o PES6753 0�•. STATE OF �'0,S'!'�ZORSDO`.•'G�# 1 /iii OVAL03 ��►it�ttit I SOLAR CONTRACTOR CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION JOSE GIL - MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 772) 332-8075 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 11.2 KW 32 MODULES: LG LG 350NiC-V5 32 INVERTERS:ENPHASE IQ7PLUS-72-2-US IN INITIAL FIRE SETBACKS AS PER 6TH EDITION 2017 FFPC REV: MIN 3'x3' GROUND ACCESS REV: POINT — I PITCH DIRECTION WIND PRESSURE ZONE LINES PROIECTINFORMA71ON DATE: 7/14/2020 DESIGNER: SN DATE: DESIGNER: DATE: DESIGNER: SITE PLAN PV -2 re L6345NIC-VS I LG3SONIC45 'AAr%W I 45nw ^. V, tt ts.ry -G c- 4^3 -04b" ly & 4(g)" c ( 1`� f*wmd Pertaww" Worrinty nes an vp.a-'Wc� wveaty Aftt- )i '03, LG WNW 7 4 it o4-'! 9006% of M" a; 16 %PON* I now Enhanced Product Warrawy L'i ova lfarlyWf I. -W Nl'cvs 2 to )S)ci-S -1 lab'- Ah'Z' 5 teni #-,Pl 'i 00;r ",,I- y # pAd Ammus -- I I T' r4 i vr.3 M —r' w trfs T"L, NeC" 2 tan e,:rvi•t t -.r �, .j' :c ;:, youf hvm we --a rwp -.7dt-n 6ruqlt When you go solm; ask for the brand you can trust LG Solar AbM L6 E WeUoakS A LG Solar LUG* 1 NeON"2 L63451VIC43 LWSONICVS V,-- 14 Arles PU-4 A -q! �(p,01 momentum SOLAR FKV (-U5 I UM SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL I ENGINEERING MA6- ♦ CE 0 867 3 4 STATE OF '00 '4' iVAIL 101 'ff"111111 77/141n 'n -2.& I SOLAR CONTRACTOR CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57031 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATIOD JOSE GIL - MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 17721332-8075 PV SYSTEM INFORMATIOD SYSTEM SIZE (DC): 11.2 KW 32 MODULES: LG LG 350NIC-VS 32 INVERTERS: ENPHASE IQ7PLUS-72-2-US PROJECT INFORMATION INITIAL DATE: 7/24/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: PANEL SPECIFICATION PV -3 %0v0pwwQOwUtwA1n tit Mon YlSyelrleAp"".0" 14 Arles PU-4 A -q! �(p,01 momentum SOLAR FKV (-U5 I UM SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL I ENGINEERING MA6- ♦ CE 0 867 3 4 STATE OF '00 '4' iVAIL 101 'ff"111111 77/141n 'n -2.& I SOLAR CONTRACTOR CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57031 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATIOD JOSE GIL - MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 17721332-8075 PV SYSTEM INFORMATIOD SYSTEM SIZE (DC): 11.2 KW 32 MODULES: LG LG 350NIC-VS 32 INVERTERS: ENPHASE IQ7PLUS-72-2-US PROJECT INFORMATION INITIAL DATE: 7/24/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: PANEL SPECIFICATION PV -3 LG Life's Good Oct 18, 2019 To: Momentum Solar RE: Approval letter to use the 2 Rail Mounting Dear Momentum Solar, LG Electronics U.S.A., Inc. 1000 Sylvan Avenue Englewood Cliffs, N] 07632 201.816.2000 This letter hereby states that LG supports and provides warranty for the referenced LG modules which have been mounted by the 2 Rail Mounting system refer to the installation manual Fig.2 for the test load of 6000 Pa downforce and 5400 Pa uplift under the test conditions based on IEC 61215:2005. System Installation Scene(Picture) - _ Down force Uplift 2 Rail 6000 Pa 5400 Pa Mounting * Under the test condition based on IEC 61215-2:2016, the test load may be different. The following LG Solar modules are approved for warranty: I LG Model Number LG Model Number LGxxxN1C-V5 LGxxxN1K-V5 LGxxxQ 1 C -V5 LGxxxO 1 K -V5 Fig.2 Clamping Type A=200mm Cl B=400mm Our warranty provides all the terms and conditions underlying our obligations and the warranty. Although this Letter serves as an authorization to employ the 2 Rail Mounting System, the original warranty terms for the modules would be rescinded in the event of - Misuse, abuse, neglect, or accident such as micro crack to the cells or glass damages; - Alteration, improper installation or application; - Non -observation of LG Electronics' installation and maintenance instructions; - Repair or modifications by someone other than an approved an approved technician of LG; - Power failure surges, lightening, fire or other event outside LG Electronics' control; - Defect or Power drop due to the incline load; If you have any questions or concerns in regards to this letter of authorization, please feel free to call your LG Electronics Sales Manager. LG Electronics U.S.A. Inc. North America Solar Business Team 1000 Sylvan Avenue Englewood Cliffs, NJ 07632 �,F(Xoj,�),,' ��� SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N] (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING 10 1111111 �dEN No PE86753 .-0 _ STATE OF '• �: //"IUs ®NAi < � 711 SOLAR CONTRACTOR CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC5703, MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION JOSE GIL - MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 (772) 332-8075 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 11.2 KW 32 MODULES: LG LG 350N1C-V5 32 INVERTERS:ENPHASE IQ7PLUS-72-2-US PROJECT INFORMATION INITIAL DATE: 7/14/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: PANEL LOAD TESTING RESULTS PV— 3 ■ l Enphase IQ7and IQ7+ Microinverters IN To team tTlore abou Enphase offerings, visit enowe.com Omomentum ..- PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLI 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 Enphase IQ 7 and IQ 7+ Micrainvel•ters MOMENTUMSOLAR.COM PROFESSIONAL 1HPVT OATA (OC) 1f17.60.2•tls?IQ7.60-e•us MPLU572.2-USP107PLUS-72-5•Us cert srtty%W1dnri*d-wP�;.d- xa5w-3satat+ :,��; , ws�. ENGINEERING- Vo-durac"Catb,hly 60•cellMVmodules cAly PVaroduIek ).ts,fdrum input OC VOhaga 48V 60V Peak power lracFm;vo8u9e 27V•37V 27V.4SV Operating range 16 V • 49 V 16 V • 64 V Mini Mait sfaf I vViaCe 22 v I s6 V 22 V 160 J � She$UNI DC Short ISA ISA � got pa.vrerFd smart gr d ready €rervollage Class DC part 11 Enphate IQ 7 Micro" and Enphase IQ 7+ Micro" OC port bacl "d cw sm 0 A O A dramat'cal y s mp `ty the'nsta 'aton process wN a Fa array Cw1gtra:eon t a t w;rounded a ray, ho a ;dtionol DC lade protaet;or reywrel, It lilt/ AC side 0; ere, tion rcau«fes ," c 20A per baanch errant / ach eVng the h ghest system er is°erlcy. GUYPUT DATA ) 13 7 miemlaverl" 10 . Microkevener `♦♦�` /�/�' Part o= the Enphase Ifs System. the IQ % and Ptak wW power 250 VA 295 VA - ±aa,:ruel canlrnuw. aul« R pswo: 240 VA 290 VA ��\ • • t)rE • • • �` •.'•� 10 7+ M cro<nverters ntegrate w'th the Enphase NOMnal(LA)valtagelra.•fpe11 24avr 2088 24ovr 208v, IQ Envoy", Enphase IQ Battery`, and the Enphase21t 264 V 183.229Y 211.264 v 10220 V o PE86753 Mil IlnLrrl CON mous out2ul current 10 A (240 Vi 1 15 A (209 V) 121 A (240 V) 130 A (204 11) = y �• En"ghten- momor'ng and ana ys-s so -t ware. 11OM"31 fraquMcy 60H3 60 Mx Eden ded frequentyran;t 47.6814t 47-69tft lQ SeeeS M`Cro"nveaers extend the W,°&'Ay At, short CYC1,,4 404 Current aw3 c -felts s $ Amis 3 a pp � � `� 4' standards set orth by prey ous generat ons and pK 20A (L -LI bsaneh ce,:u tr 16 (2:0 VAC) 13 (20.3 VAC) 13 (240 VAC) 11 (202 VAC) � O • STATE OF ♦,�� undergo aver a ri'4i on hours o1 power -on testng. AC port ac Cee d cur pan is Rfl �i���� • •!p�O�IDP;. •'• �t�v� AC port backfaed current OA GA enab °ng Enphase to prow"de an `ndustry ead'ng Power Lector sett+ig 10 ♦ G Y,re1r$nty O= up to 25 }°2$rS, Power 3etta'adiuittsbk) " 7 ir.a� 0 r w 0 71Ea6n 0 t• '//// oMA�. v� 0♦ EFFICIENCY (;ileo V �20a V Z4 @202 V „ n PaakCECefhciency 976si 476 K 97511 97394 711 , / r I, `% CECweightedefrrc.ancy 9 0'•: 970 97D•> 1020% !/l// r MECHANICAL DATA ArrWiMl teinpiratura eange -4GIC to +65` C Relat.ve Kuri=dqr range s < to 100%;condensng) Easy toInstall C0rrW00rt}pe(t03-irtt-2•VSb107PLUS-72.2-W) MC4(or ArnphwIWK UTXwAhaddaoonslO.00"edapter) Lightweight and simple Cwv*ctwtype{IQ76083IS&1Q7PLUS°72,9°US) FrundsPV2(MC4ntefmaleebie) Adaptors for modules with MC4 or VTX cerr:actors faster 0nstatlatiOnIII thwpFamd, ghtertwat'°w re cabling PV2toMC4Order ECA -$20.822 Built-in rapid shutdown Canpt.aIII (NEC 201414A 17) PV2 to UT order ECA -S20 -S25 Oirtreneians (wxFfx D) 212 meets 175 MM x 30 2 mm (w4houi bracket) 1YeE0ht 10 2 bs) SOLAR CONTRACTOR Productive and ReliableCoohig Natureralcalca mveetra9. t+o tans Approved For wet focal A,%5 yes CAMERON CHR3STENSEN i It:m*led for ttrgh powered t�O Ce 3 and 7i•ce1l• rr otlulcs Pof wndegrK CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC5703 PW M More than a rhili n h®urs of test no EnC1C3ve5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 Crass R double -insulated, corroaranresntart palynerreenc/osure • Class fldoutile•ins48tedereosure Er1YMOM'HMtalcategory lWO.-o" reraL_nQ NEMA Type btojwoor CUSTOMER INFORMATIOD 3;'. hired FEATURES - emn9tm+icatre PewerLiteCornrruelicatiai{ptC) JOSE GIL- MS52684 S111ar t GtEl! Ready Von -bring En 0hte4i Ranagerand MyEnhghlenmonitorogcotiars 6306 EMERSON AVE Both aptiom require kilts fationof an Enphasa IQ €nvoy Olsconmetao means Tha AC and OC eomaetdrs haw b"n fvsktsted and aWOwd by UL far ina ea till fosd-break FORT PIERCE, FL 34951 • t:ort.Phessr.,ihadvaneedgl:dwppcxt.voltagearnd frequency ride through requr-ernenis dlatarinsct required by NEC 69 772) 332-8075 GonplianCe U1�67041,UL1741JEEE1547•FCC PwiI$C4rs9 ICES-J03Ctas:e. PV SYSTEM INFORMATI011 (remotely updates to respond la changing CA grid requ,femerits CAWCSA.C22 2 No 1071.01 Cdrlfigurable for varying grid profiles The product is LLL Laced as PV head Sim Down Womw and conforms with Nee -2014 aril SYSTEM SIZE (DC): 11.2 KW NEC -2017 seauan 69-312 and C221.2015 Ruse 04.218 Rapid Shutdown of PV Syate r w. " s A'r Meets CA Rule 21 (UL 1741, SA) end OCCondueters•wti installedacewdinprranu(acnstr•sifttruct^ons 32 MODULES: LG LG 350N1C-V5 • IhK ii :. ll a iaa °. - a e+•1 r,..nxlaLawl T,T rr2 •rwb0� 32 INVERTERS: ENPHASE i Au rxr -„t d rAfii4. ai.•v.y1111Si-'':rsra#ttOtDi%i�lfeay-� IQ7PLUS-72-2-US r: -A-0 nal .eal.1•Ik l.id :X r,,ut tw, i a.+ VA"Ie I VO 111.`? Y rsM 1(r5x red r r the 4r 1 !r a'.•it.ft, 401401,>n. tier 41.e Mitt "'mi Ro t-* *w"w h"fw I 1 90n.i1 Im grey trnnrh n Yaw. rr EN PHAS E. To learn more about Enpl'•ase offerings. visk tmptiim.com v EN PHA$ E, PROJECT INFORMATION F” •x r. �. � r-• - .rtn.rt -...•a a: w:;x••, .. . i a- a INITIAL DATE: 7/14/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: INVERTER SPECIFICATION PV -3.2 Enphase IQ Combiner 3 (X-10-AM1-240-3) 7 i -he Enphase !Q Combiner 3 ' rt• wr. 'rd se 10 En. -8y conso Oates ntercon 4ect or -Qu crient rao a s n:: a erc osufe ar;j stff,am rips r,V er;) 11'OPagp fnst - at Ors tl f -ro. 1 n j a ccnr ; s.ten� rleL "I rL-,l SO ut on °®f !sty zlf-rt a acr cat ons it O"'ers 'r, to `Ou" + C� "tisrUt C rCu 13 and Eat211i W$S 1.rraI* • OcVO 0 Er'aKrr!p+ cnT•rL-,+cn ti'• a'd CLTirr� Pea=be ne[wWk,ng%!.*pats w:•f Etherret. 4' tettu at • 00<.y4 Ar t,...l aft PLC br 42r! • FtoY-0es p!odltt:rsa rttcter ,_� n";! r:�i :�aa ta°calmEt�os nsofl ttt,rt¢) $l -t pk- Reduced s re !foal of" sus comttner Gtr't .d Dor t.-.2 erat>'ete st,Fpah smq!4 Stwc rritrrtt -ifj • S%.P"•Mhac-drTtl�:ecvdLIerVy UP W 10W 240 e arch C,rtwts tart 240 VAC • 60 A le4at PV r' 0waga brano c cysts fiPiti bk • Ei4'at11e `:ATL-te=id:._d t.EfidA Ippt 9J'1 ertlpSL `e • ie'r!,y�tesrlrrmrtrd+Narraney UI I„rr4 v ENPHASE. Enphase IQ Combiner 3 MOCEL NUatBER 1Q CGrTntl aYr � s,,tl'. fr+tft►/4 i4'} f n,Qf't:'�*'.;Md G,r�it p Wed tCr •nt priti� ft+itr�trl� prsdf f+� &tetfutran fr N+'d iA�sSr C t2 N •,.4 54 "*M' onsf- tEa1t Wps 1 an nP6+u1 Y10 t+J• 2 5 I ACCEJ 0#fE5tNREPLACEAIENT PARTS incl nctu:ttd, 0f9er trparra�tt_rt �� Crtrx+t•ct C1 iAt4%JEitA•Di(iGit2.1'frl+ditaPll++) PhrON�4Plrriayrirt.tiCradtCerytNmOtlM+wehdstap4rll<O�rtal't''t1+f+/i+yrt0$Q CEtt.M00EM.01(3016-yapdataytan) rnkaO+NMTara (A•arlab0nfUS, Canacft l rG9Puotosimo, nftusVirg" 41AP49. tEililt70f1YtA3tiGbbadETE•hfaSyeerdelatNfrO w#+rratiwrsprpar}tfttcatkdvin.tca,rTthairata:iotanraaj Conswrc,trontJpn,lang• G' Sc°,1 tar cvrcnT tranatxrr=rs tnaCtt'wtrs � trtmeconaumF:'ian rrt"rrmq (. 2 S • CT•200 SaLli .aa,a*•-<: 'v.y..e ., rG<rr ,•, e) a .. w4kro3f UStl adapt" 'r+lalad at ttM ,Ca Erma Fbe rprtvpfrrt,GaLer6 w�ih /Ohfet i.tKJucgf `. llOra+,la srW Er i:bf C401tMS W-01 Enoowyf'frtyftfw3ch hca+C+s tjsatabir tG. fL IIVLI OrriQ IQ 1�Pti8roji t,,T°.a tQtU'16rw a'!Ct a W w'1 fadlRldaM wYt7ei f COfMfl,C [a1,pn wM FLrrA�ilCLia irYd t'rC`�'wM t+:ua3'r3"ctrl 8Rk+04'2'24 S'•Ct .#s!=: $R?1} 60 ++. B;?:� g�?+) CR?43'3R`Rv},az7Bn:er -,.;...•c•=t+very 8Rk;5A2.2a;t 4'+ . tter p.r t Lt `^ii=''4: l:a 5'tt�r r: .t t'A E•,r:$T.+5 4Rk.'34A'ta;?40 Ekt 01. Power lays carr Ir+ Ctorm Y4as {anon br+dpt e1, gYif11!ty - ana Dai AA r't.Z 120-I 4ccfri0rr r� CtCktCte t0r P7wr L* a Ca ratr n OC,vriarrw j(reaMtrd for ff C 911 xA•Ek CIIA•3 t'*0LkaMW41Qflrrojpraye4t•`tvtQaaratRtBt!o'taranrer ELECTRICAL SPIECIFICATIONS Woo C or+trr.Aws dot y Srfterrvclltze 1215,240VAr, 0N; Eaton 8R $arm b#Abm ratexr 12S A 0143t c04!'rIJ014-.V'f ',11'+2:0Varc.Gbpr91 05A M&A hrtaitstutn}etpCOutpvt 90A Soar,& Cctintf €1c v and'or 5Wa+je) Lh110 feta 2 Poll 0 -on 9a w -ft 0,21,4 ,ted ritnrra"20 kw,' 6rle➢Nf Ontd {rM nc Wod) Maty corttftms eLrru9 taut* tr'ktl ham PY) 64A Mac ictal l`�arxh twttatN#akar fal•rt,y,ia'Q,tt) ffirlA ar pvytrrpriie=�;}Srar°at^�y2A w';h sQ �nn3r txatr.*r :r:V�.kt PtabiS C+On MNMnaCt 200 A!o!d cora pro-nftalkT•d and:*pftd to Iri E"My MECHANICAL OATA rnafes+oG+a(SM,►fxtlj 44Sx3JSx158ar(195a1g33' 60r)wgniof2ipp'(73sc'rwermanangpryrtityj AneGsra tornperaturt rarrlo •40►CIO .arY C t•a� tai 1 Sf Ti r octing Nltwai ;u'rec rim Ow hat s + t 9 Er+ttoauraarnrarrfwKatrat •j Outdoof,Wt—cwIffud, WMA type 3Rpobcarbpytacorrtrutfon waroIzrr • :OA••o30Ato"&We -s 14.04Awa wptrcor4,Kt9r! • 60 A 0"o" bfsAc ! svUT a To too +i' YG CC #f 4cq%dU4t0f! • luar•tugcacAneloutput lOSa2.0AwGcopptrc,snjuct,�rf • tiar:atarsdyound i4tal,Jtap7rrtandr_t"r: Anwars to x�w W#1cadtiv4U4* nenif W comkivot *,ran Atptuda To2000ir4tsts(6•S60 root) INTERNETCONNECTION OPTIONS Int*orgitdww'l Ethanal flptdul 1802 3 CaiS€ (a Colt) U100-wrtt cfb'a (601nckriri co0ww 40tt"tCELL$,AOOfM4t43GrtfCELLAed3 M41(4G)aCELt4ICM1 m4At(4Gbl- C ORRICE Ctr7Q lr Tt.Gxtubrltr to 1fIt,�AatrCSA C222t+1a t'Oft, )C1:fi. Part 13• Coss j,—C— 0`oj PfOducttoneneN09AW44C122iEaccws'' cws0sftritModJKI m »arrptArC+.'g Frt.of L*E 6:!801.1 CANCSA 2I 2 No 610104 TO learn nate aborti Unphase Offerings wstt eeptim.mm v ENPHASE. momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOL/ 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING 1%, IIIc II E • No PE 8 53 . r . d- =_ *Raw. STATE OF LORI SOLAR CONTRACTOR P I MUN CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC5703 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATIOP JOSE GIL - MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 (772) 332-8075 PV SYSTEM INFORMATIOP SYSTEM SIZE (DC): 11.2 KW 32 MODULES: LG LG 350NIC-V5 32 INVERTERS: ENPHASE IQ7PLUS-72-2-US I PROJECT INFORMATION INITIAL DATE: 7/14/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: OMBINER BOX SPECIFICATIC PV -33 solteion" wVnciiciar RJ -1 Residential Transition Box Th a Sottect +on Rj-1 rooftop junction boat with flasWt g provides a safe, secure, and NEMA 4X waterupht solution for We Solar it stalter to penetrate tre roof for attic runs anal matte the proper wire conrectiors, Tire product Is designed to be si riple to install, minimize tide on the roof, w'1'le additioraliy p-c+viding higher levels of protection for the point of peretration r the roof as well as electrical corrections inside the ju irtion box, Key Features • Qesigrted specifically for solar irmulatlons • N4n-tneuUlc—WN NOT rusticorrode • Easy to driitfntodify • Captiva screws in cover- will not fail out • Nk)iM&l design. small footprint • NEMA 4X rated • All roof peratraWns cover by Nems 4x enclosure C @ us USM saltecakalby YyrAW Vyectxr r1KW 4fr S"KernK 271 I kUny S tet H0.610M TA 7;Qe r tKA +1 a6&227 o577 *ww 54NMt! � tAnf Specifications Enclosure Material: Potycitb hkodw/W inhibitors UV S:abil12ed:: Ve: % ln+pact Res4taoxe: Yts Weight. 2.731b Color. Graphite Black Dimensions flashing Dimensions(Appronvi3ter t3 -x r FncWure Dimensions (Apprrximate):5- x r Total Product Height: 3.51 Cuhic :n&,es: 224 Ct6c Inches JUNCTION BOX SPECIFICATION FOR SHINGLE ROOFS momenturi PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N] (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING `��`` 1e�E • •3F ��i _Z No PES6753 `.d O� STATE OF *--�XORIDp;.•'# 111 //;/ ®NAL frfil � 0711q w SOLAR CONTRACTOR CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC5703i MOMENTUM SOLAR 5728 MMOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION JOSE GIL - MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 772) 332-8075 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 11.2 KW 32 MODULES: LG LG 350NIC-V5 32 INVERTERS: ENPHASE 1Q7PLUS-72-2-US PROIECT INFORMATION INITIAL DATE: 7/14/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: JUNCTION BOX SPECIFICATIO PV -3.4 OVERVIEW OFTHE SNAPNRACK ULTRA RAIL SNAPNRAOC, ADJUSTABLE END CLAMP. :ALL REVISION: -� SNAPNRAIX UR-fi0 RAD. AND SPLICE DETAILS SYSTEM INSTALLED ON A TYPICAL ROOF SELECT TO MATCH MODULE HEIGHT _ I/r MODULE SPACING AMDjrBR SNAPNRACK, MID CLAMP. REFER TO SNAP14RAOC INSTALLATION MANUAL FOR REFER DETAILS SONA TACHING ND DETAR' SELECT TO MATa TORQUE SPECIFICATIONS WA ERPROO IN ATTACHING AND - 5/16' DIA HARDWARE WATERPROOFING THE VARIOUS MINAE HEIGHT PN MODULE, TYP. SNAPNRACK ROOF ATTACHMENT PRODUCTS REFER TO SPECIFIC *COMPONENT DETAIL' PV MODULE, TYP. SIMAINRACC UL1A14 RAIL W MODULE FRAME. TYP. FOR DETAILS ON VARIOUS SNAPNIRACK SNAPNRAIX, UNIVERSAL END CLAMP. ACCESSARY AND COMPONENT PRODUCES MODULE HEIGHT AGNOSTIC AND SNAPNRAOC, ULTRA RAR HIDDEN BENEATH MODULES BOTH THE SNAPNRRA UNIVERSAL ENE t DETAIL A: DETAIL B: SNAPNRACC, ULTRA RAR CLAIM AND SNAPNRACK, ADJUSTABLE END DETAIL C: CUM CAN BE USED ON END MODULES SNAPNRACK, ADJUSTABLE END CLAMP SNAPNRACK, MID CLAMP SNAPNRACK, UNIVERSAL END CLAMP MODULES MAY BE CIAMPE ON SHORT OR -PV MODULE, TYP. LONG SIDE PER MODULE MANUFACTURER _ REQUIREMENTS - RAILS MAY BE MOUNTED UPJDOWN OR - - - ACROSS THE SLOPE OF THE ROOF -SNAPNRACK, ULTRA RAIL REFER TO SNAPNRAIX INSTALLATION -.�- 'RAI. END OVERHANG I ----'RAR SPAM DISTANCE BETWEEN MANLML FOR 5/16' DIA HARDWARE TORQUE DISTANCE FROM RAR END CENTERS OF TWO ROOF ATTACHME N T S -- ---� SNRPNRACIC ROOF ATTACHME SPC�TGTIDNS TO OUTER ROOF ATTACHMENT CE11113R. VARIES WITH ROOF TYPE NOT TO EXCEED 34% OF ALLOWABLE SPAN \\-STRUCTURAL MEMBLB! SNAPNRAIX, ADJUSTABLE SPLUNRACX, Mm CLAMP. END CLAMP. SE ECT To SECT ETO MATCH MODULE HEIGHT MATCH MODULE HEIGHT / ~~ - _ SNAPNRACX, ULTRA RAIL DISTANCE FROM RAIL SIOEX N CENODUIE EDGE PV MODULE, TYP. -__ _ _ - NOT TO EX® 25% OF MODULE LENGTH OR MODULE MANUFACTURER RECOMMENDATIONS -' I / '-T-- ~.•. _ .�/ - _ n •` SNAPNRAC, ULTRA RAR ' 111 i y c END CAP, OPTIONAL ROOFINGJJ COMP SHINGLE SHOWN, TYP. II, ROOF SHEATH... AND -r UNDERLAYMENT MATERIAL, TYP. i� STRIICTIIRAL MEMBER, SNAPNRAIX ROOF ATTACHMENT, VAIRES WITH --�— WOODEN RAFTER STKINM. TYP. ROOFTTPE . TO SPECIFIC'ATTACiMEm DETAR• UR -00 RAIL I UR -60 RAIL FOR ATTACHMENT B WATERPROOFING DETARS FOR Lig VAIN SNAPNRAG ULTRA SERIES BALLS 2 r-, cc, ,f MeuXlwn Bloutlq ®q�W OESIGNEt: MAFFENT F DNS DRAWING NUMBER: DBCtflT[ON: 2� (rll l`F I <, U �• " «:� DRAFTER: MAFFENTI GE0. SNR -DC -W329 ULTRA RAIL, SYSTEM OVERVIEW, TYPICAL .^�:.T'^�-• APPROVED BY: 6. PET F1LW 5/7/2D19 DESGRIF74CW: DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT mwatk(ns REVISION: PART NUMBER(S}. SEE BELOW V 406 1� d• 1 f PARTSIST C)JT_L----y f ITT_ YM I PART NUMBER I DESCRTPITON 232-01375, 232-01376 NAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER /BLACK ALUM MATERIALS' 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER DESIGN LOAD (LBS): 405 UP, 788 DOWN, 236 SIDE ULTIMATE LOAD (LBS): 2006 UP, 4000 DOWN, 1070 SIDE TORQUE SPECJKCAT'ION� 12 LB -FT CEFMFIGATION: UL 2703, FILE E359313; WIND -DRIVEN RAIN TEST FROM ULSUBJECT 2582 WEIGHT (LDS): 0.80 U APPROVED -ANYWHERE ALONG RAIL SPAN THERMAL DIPALLSOU GAP: BETWEEN TWO _ ROOF OVERHANGS I 31W - 5/9- RACK, UR -60 SPLICE D NOT APPROVE - RAR ATTACHMENTS /SNApM CANTILEVERS SNAPNRACK, UR -60 BALL -� I SNAPNRACC UR -60 RAR - FASTENS TA TO ROOF ATOIMEms VIA TME'SNRPNRACK, ULTRA RAR MOUNTING HARDWARE! =+ . ULTRA SNAPNRACK, UR -60 SPLICE INSTALLED, TOP SNeouoe r ,ion ..n RAR SPRING AxD SPRING CACE, .PHONAL 6:::=T.•1B BOLSSIRES 5/16• DIA: 18 X 311' -TORQUE ALL FASTENERS TO SNAPNRACX ULTRA THE SPECIFIED VALUES PRIOR PAR MOUNT, TAPPED TO INSTALLING PV MODULES SNAPNRACK,ULTRASNAPNRACK UR -Q BALL MOUNT, TNRU SNAPNRAIXRODF ATTACHMENT, VMRES SNAPNRACK, ULTRA RAIL MOUNTING HARDWARE O-RIN. F -__ SNAPNRACK, UR -60 SPLICE,: -T 1174 1 2 U4' 1 SNAPNRACK, UR -60 SPLICE SNAPNRACK, UR -60 RAIL Shu tg ap v� �� .�M� D6[GNBL MAFFENTRAN(IER �..,7`v, �•••••�„", DRAF Eft MAFFENTRANGER � e APPROVFp 4Y'• R,PFTERSdM SNAPNRAIX ULTRA RAIL UMBRELLA L FOOT WITH v� UMBRELLA FLASHING FOR ODMPOST10N ROOF UB40: 3 3/8' • 4 3/B' SN MOUNTING UR -60 4•5' UM REEL TO ENGINEERING FOR E RAIL SPANS,'BNUMBER ON CART SHOULD MATC1'BIP NUMBER ON THIS DRAWING 5/L6'DA. SS. UMBRELLA LAG SCREW MUST ENDED A MIN. SNAPNRACK OF 3' INTO STRUCTURAL MEMBERI ULTRA RAIL REFER TO SNAPNRAOC INSTALLATION MANUAL FOR .k S/L6 D0. HARDWARE TORQUE SPECIFICATIONS RAIL CAN BE MOUNTED ON ETHER SIDE OF THE , L -FOOT FOR LEVELING DETAILS, REFER TD SNAPNRACL DETAIL DRAWING SNR-DC-OD332 ULTRA RAIL, COMPONENT DETAIL, LEVELING EXTENSION LOT' SHINGLE COURSE rl �� T�-4�p T � � $ 2 USI' 1_{ I UR0�RAILJL I UR -60 RAIL INSTALLED SECTION VIEW FOR USE WITH SNAPNRAC( Al SERIES RAU 8wrvn Bonn uc DESIGNER HAFFENTRANGER c:LI ll �u' Lrn��U-�J ^^•••��••,••� "' DRAFTER: M.AFFenRANGER APPROVEO By: B.PE(ERSON 'Ftl']APk: SNAPNRACK, UR -60 SPLICE, EXPLODED DNS uwwuw mAl,uuc SNR -DC -00331 5!7/2019 K ULTRA RAIL 4FD0T SNAPNRAC( 5/16' DIA SS- UMBPELLA LAG SCREW, TYP. 3• MIN. EMBEDMENT INTO WOOD MEMBER DETAIL SMAPNRAIX UMBRELLA FLASHING MUST SLIP BENEATH THE UPSLOPE SHINGLE COURSE ROOFLEOUNG STRUCTURAL MEMBER ONS u,wwuYU nRA4HRx 6/18/2019 SNR -DC -00339 4LLED, FRONT ULTRA RAIL, ODMPONENT DETAIL, ull-w RAD_ AND SPLIa 2 DN: REVISION. SHINGLE ROOFING, TYP. 8 OF DEOaNG,,YNOWTVP. _ / RAFTERM TVEMBER TYP. momentum0 • e PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING 1114 fill clUv 86733 ��� • STATE OF /701VAL•1Eta���� l 0.7 SNAPNRAIX EP M UMBRELLA GASKET (SEALS UMBRELLA LAG AND UMBRELLA CONE) SOLAR CONTRACTOR UMBRELLA COME ON CAMERON CHRISTENSEN FLASHING TO `SHIELD WATER CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57031 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION JOSE GIL - MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 772 332-8075 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 11.2 KW DETAIL 32 MODULES: LG LG 350N1C-V5 32 INVERTERS: ENPHASE IQ7PLUS-72-2-US ULTRA RAIL, ATTACHMEff DETAIL, UMBRELLA I BSI B L FOOT TO RAFTER ATTACHMENT DETAIL FOR SHINGLE ROOF PROJECT INFORMATION INITIAL DATE: 7/14/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: ATTACHMENT DETAIL QV -3 m S CERTIFICATION OF WIND LOAD PRESSURE CALCULATION THIS IS A 2 -RAIL DESIGN DESIGN LOAD CRITERIA. AS PER ASCE 7-10 (2.4.1) FOR THIS PARTICULAR CASE, THE "DOWNFORCE" CASE 2 AND UPLIFT HAVE BEEN TAKEN INTO CONSIDERATION. P (PSF) =1XD + 1X PNET (DOWNFORCE) P (PSF) = 0.6XD + 1X PNET (UPLIFT) (P = TOTAL DESIGN LOAD) (PNET = WIND LOAD) (D = DEAD LOAD) PNET HAVE BEEN CALCULATED FOLLOWING THE ALLOWABLE STRESS DESIGN METHOD. THE MAXIMUM ABSOLUTE VALUE OF THE 2 CASES IS THE UPLIFT LOAD. THIS 2 -RAIL DESIGN IS WELL UNDER THE CAPACITY OF THE INDIVIDUAL ATTACHMENT CAPACITIES FOR THE DESIGN. THE PHOTOVOLTAIC MODULES USED IN CONJUNCTION WITH SNAPNRACK2-RAIL ATTACHMENT SYSTEM ADDED HAVE A DESIGN CAPACITY OF -4,000 PA., 84 PSF. THIS DESIGN IS WITHIN THE LOADING CAPACITIES OF THE PHOTOVOLTAIC MODULE 2 -RAIL DESIGN TESTING CAPACITIES THAT HAVE BEEN PERFORMED BY INDEPENDENT TESTING BY THE PANEL MANUFACTURERS ENGINEERS. SEE ATTACHED MANUFACTURERS TEST DATA. 10 % OF LEAST HORIZONTAL DIMENSION OR 40% OF THE BUILDING HEIGHT WHICHEVER IS SMALLER BUT NOT LESS THAN EITHER 4% OF THE LEAST HORIZONTAL DIMENSION OR T-0" ALLOWABLE LOAD / ATTACHMENT 5/16" LAG SCREW W/ 3.00" EMBEDMENT INTO RAFTER BELOW ACCORDING TO THE NATIONAL DESIGN SPECIFICIFICATION FOR WOOD CONSTRUCTION 2015 EDITION. = W'= W X CD X CT. - PER TABLE 11.3.1 NDS 5/16" DIA. 4" LONG LAG W/ 3.00" EMBEDMENT INTO 2X ROOF RAFTER (SEE SHEET PV -2 FOR SPACING) W'= 266LB/IN EMBEDMENT (NDS11.3.1 TABLE 12.2A) FOR DF. LARCH, S.Y.P., AND S.P.F. SPECIES CD = 1.6 (TABLE 2.3.2 2015 NDS) CT = 1.0 (TABLE 10.3.4 2015 NDS) W'= 266LB/IN X 3.00" X 1.6 X 1.0 = 1,276.8LBS = ULTIMATE -THREAD MUST BE EMBEDDED IN THE SIDE GRAIN OF A TRUSSES OR OTHER STRUCTURAL MEMBER INTEGRAL WITH THE BUILDING STRUCTURE. -LAG BOLTS MUST BE LOCATED IN THE MIDDLE THIRD OF THE STRUCTURAL MEMBER. -THESE VALUES ARE NOT VALID FOR WET SERVICE. -INSTALL LAG BOLTS WITH HEAD AND WASHER FLUSH TO SURFACE (NO GAP). TORQUE AS PER MANUFACTURERS SPECIFICATIONS. DO NOT OVER -TORQUE. -WITHDRAWAL DESIGN VALUES FOR LAG SCREW CONNECTIONS SHALL BE MULTIPLIED BY APPLICABLE ADJUSTMENT FACTORS IF NECESSARY. SEE TABLE 10.3.1 IN THE AMERICAN WOOD COUNCIL NDS FOR WOOD CONSTRUCTION. WIND LOAD CALCULATIONS (ASCE 7-10 30.3.2) VELOCITY PRESSURE Qz = 0.00256 Kz*Kzt*Kd*V^2(LB/SQ-FT) 0 EXPOSURE B I'YIOtYt@i'1ttAl'TI Kz (VELOCITY PRESSURE EXPOSURE)0.57 SOLAR Kzt (TOPOGRAPHIC FACTOR) 1 PRO CUSTOM Kd (WIND DIRECTIONALITY) SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N] (732)902-6224 0.85 V (WIND SPEED) MOMENTUMSOLAR.COM 160 PROFESSIONAL MEAN HEIGHT 15.00 ENGINEERING VELOCITY PRESSURE Qz 32.02 EXTERNAL PRESSURE COEFFIENT (GCp) (ASCE 7-10 FIGURE 30.4-28) ZONE 0 To 7 TILT 7 To 27 TILT 27 to 45 TILT DOWNWARD% 1 -0.9 -0.8 -0.8 0.3 j' /. 2 1 -1.1 -1.2 -1 0.3 � ttttl f A. 'f/j#/ 3 -2 -1 0.3 ��� ,,.,..... �. �`� .•' .IGEN ••. i DESIGN WIND PRESSURE p = Qz * (GCp -GCpi) WHERE GCpi = -0.18 SOLAR MODULE TOTAL WIND PRESSURE p (ASCE 7-10 EQUATION 30.4-1) o PE86753 '• &.. ZONE 0 To 7 TILT 7 To 27 TILT 27 to 45 TILT DOWNWARD �; ; 1 N/A -19.85 N/A 15.37 .. TATE OF (V �� ' •. XORiDN.•' 2••�'�`�� N/A -32.66 N/A 15.37 3 N/A -58.27 N/A 15.37 SOLAR PANEL WEIGHTED UPLIFT PRESSURES (PSF) 071,q ZONES ZONE RATIO 0 To 7 TILT 7 To 27 TILT 27 to 45 TILT 1&2 4:1 N/A -22.4106 N/A 1&2 3:2 N/A -24.9718 N/A 1&2 2:3 N/A -27.533 N/A 1&2 1:4 N/A -30.0942 N/A SOLAR CONTRACTOR 2 -RAIL RACKING PLUS SOLAR SYSTEM DEAD LOAD CAMERON R LICENSE CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC5703 COMPONENT WEIGHT/UNIT- # MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 MODULES 37.7 CUSTOMER INFORMATIOD 32 INVERTERS 4.0 32 JOSE GIL - MS52684 6306 EMERSON AVE RAILS (2 -RAIL) @ 5.8LB/LF. 1.8L6/LF 16.0 FORT PIERCE, FL 34951 (772) 332-8075 GRAVITY LOAD PV SYSTEM INFORMATION ATTACHMENT/FLASHING 0.98 66 SYSTEM SIZE (DC): 11.2 KW ARRAY TOTAL 577SF 1399 32 MODULES: LG LG 3S0N1C-V5 TOTAL LOAD/ATTACHMENT 21.20 32 INVERTERS: ENPHASE IQ7PLUS-72-2-US 2 -RAIL RACKING SYSTEM ATTACHMENT TOTAL LOADS ASCE 7-10 30.4.2 MAX WIND PRESSURE ZONE 2-32.66 PR07ECrINFORMA77ON TOTAL WIND PRESSURE -18842.17 INITIAL DATE: 7/14/2020 DESIGNER: SN TOTAL ATTACHMENTS 66 REV: DATE: DESIGNER: REV: DATE: DESIGNER: TOTAL UPLIFT WIND LOAD ON ATTACHMENT -285.49 STRUCTURAL CALCULATIOP TOTAL UPLIFT FORCE/ATTACHMENT POINT-264.3LB 264.3LB IS BELOW THE ALLOWABLE 1,276.8 X.33 = 421.34LB PV -3.6 PR06RESSIYE mxTeNIxLs SS 300 Series Professional Grade Silicone Sealant BASIC USES & DESCRIPTION: SS 3W Stenos St ccm Soalsnt,s a meci ;,m rr Biu"us slcoa sealant deli +'d %r-tyofir at- pocaticrTsar+dr f{)US;QenL3F3pt:{3tOr�S COLORS; SS 300 Series Silicone Sea -an, 's aLa` add it 3 standarcx coiom vvh!er SS 301 ' r Irl • SS 307 tit Ciro)+- SS 303 (C.stom colors -ray be aia:labta upo'1 mq.restata_ additional char9c) PACKAGING: SS 300 Serir4 Silicone Sea',int'S 4 a ade it t00 if or. car,r;d5*s WEATHER RESTRICTIONS: 3S 300 Series Sitirc-9 Sea'ant shodd not he appl ed vv�en temperatures are be'ow 20`E or above y 20- STORAGsE AND SHELF LIFE: SS 300 Series Silicone 'Sea`ant has a recommended shelf L, -'e of 12 nvotem from date of manufacture w+sen ste^ed n u -%opened con:a'ners and betwaeen 50'F and 80'T Reser to ptod"t Packaging for manufacture date, APPLICATION: Tne su-tace crust be clean, dry and free from oils and o1hrer CQrat3!nin$ntS. Ather0ugp, wire e�- :,P - solvon't clean ng Msy be req ssx4aco SS 300 Sones is cyKtv*4ess on most Common. nonporous b0d ng substrates. Consult Progress=ve Materials. LLC For primirg feca'rwrendatons on other materials. In all cases, a uniplte 6+"j Aj be testerd ')rWor test joints 0* -.111* i^stilled on the pro"I to Ctxlfirm $vtaiyi ry TYPICAL CURE RATE. Cnre we at 77'" ao *d 50% RFI; A, lack -f-" *tme,. 30 minr;to$ t0 1 hoar 'Technical Product Data CAUTIONS & RECOMMENDATIONS: SS 300 Ser.'es in eea.her tested -,of twesemed as suita6e sat Mr i� jl or ph8-r"4CCt ic4l v"S' SS 300 Ser=ax is not -momrrw-rv."ed'or silicone struc::,•al 94x•-qj, apptication in con,,ned areas w4hout wooer vent satst:n, or ;oinis uncle' cans -ant water subare-s;on. LIMITED WARRANTY INFORMATION PLEASE READ CAREFULLY The Wanratic^ herei•• is to ass'st customers in deterrni i "3 M-et*w th's p oduct is suitable for vai"s appticat o^s. Tris produtt is e4 ntended foe sa'e to induStral at`d ccxrMt-cal cosiomers. Customv-s assume (4 u responsibility for gsatirj control, tr r -j and detcrrnination of sAtabality otpro€t lets to, vis "nte-ded appi.:at`on or use We vva rant that cvr products will r-.c*t 0,yr vt,r rten specikicaticns. We make no other vrarra^ty of n:etchw-stab sty of fitr&A for a partitutar purpose. Our total Habil ty and custorrew excsasitiv remedy for aii proven cl;oos rs rrc►4xC c �t Cf nonconfo-minq cmdue::yntt in no overt Aall we be =able fc• a -:,r other damages. including vr.tfwout I'miiation to speeal, intiotntal. Pk n't+ve, otconsecverttial damages W"CAJl PROPERTIES Test ... ar%pmie Joint t (W sets A 7 C -$,I.12 E, tion no 00 AS', A4 0-41 T.A. 140 MTN0 412 Gltr 100'!L 16""d" 3d AS.lrt 04 t7 t't4rdrbas Shwr A 25 ASTM C,661 UCWFIE" Tttrwr (MIMA04 60 ASIMC-629 Service T.rmf,rratrnt rn .S9 to *M PV Acawl""wd W"dw h X sago t ivoc cera ASTM C 793 ( .050 AS'M 0 5 Conor: ftgressive Mate is for more detaifed specifrca ons on our rorsfing systems and to find a certified contiactcr nftf you. CRC RIMA us <@> ...•....c_ -.e.. USM Ap'PigMM ,^tOvrSAMCUte. Fo4wajey td, 2014 SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING � ItsIj'r It o Ea 753 �O�••.3 TATE OF /111111110 0-7hvI�� I SOLAR CONTRACTOR LIC CERTIFIED SOLAR CONACTOR ENSE NUMBER: CVC5703i TR MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATIOD JOSE GIL- MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 (772)332-8075 PV SYSTEM INFORMATIO1 SYSTEM SIZE (DC): 11.2 KW 32 MODULES: LG LG 350NIC-V5 32 INVERTERS: ENPHASE IQ7PLUS-72-2-US I PROJECT INFORMATION INITIAL DATE: 7/14/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: SEALANT SPECIFICATION PV -3.7 Safety Data Sheets before using this product. DESCRIPTION: KARNAK 19 Flashing Cement is a scientifically compounded composition of selected asphalts, mineral fibers, and refined solvents that are manufactured to a heavy consistency for application by trowel to provide a durable, elastic coating of excellent adhesion and high resistance to water and weathering. This product dries to a tough, flexible, waterproof and corrosion proof coating which gives excellent performance over wide ranges of temperature and weather conditions. KARNAK 19 Flashing Cement is available in 3 consistencies: Summer, Semi and Winter. USES: KARNAK 19 Flashing Cement is a general purpose cement for repairing leaks in shingles, concrete, metal or asphalt roofs, flashings on walls, chimneys, flues, downspouts and cornices. It is excellent for sealing cracks in concrete and brick, as a joint filler for precast roof slabs and for general purpose use in maintenance of exposed buildings and structures. SURFACE PREPARATION: All surfaces should be clean, dry and free from oil or grease, dust, dirt, loose paint or other foreign matter. Recommended application temperature is 40OF to 120°F. If applying at temperatures lower than 40°F, the substrate must be free of moisture and/or ice crystals. APPLICATION: Spread KARNAK 19 Flashing Cement to an average thickness of 1/8" (approximately 8 gallons per square) and press tightly into joints, seams or cracks. To repair large cracks, breaks and blisters: 1. Spread KARNAK 19 Flashing Cement over the damaged area. 2. Embed KARNAK Cotton, Fiberglass or Poly -Mat Membrane reinforcement. 3. Apply another coat of KARNAK 19 Flashing Cement over the entire patch. SPECIFICATIONS: Federal Specification SS -C-153 Type I (Except Non -Asbestos) ASTM D-4586 Type I Class I IGWRb"330 CENTRAL AVENUE, CLARK, NJ 07066 732-388-0300.800-526-4236 • FAX: 732-388-9422 Revised 12.14.18 WEB: http:/ANww.kamakcorp.com Safety Data Sheets before using this product. PHYSICAL PROPERTIES: 1. Consistency: A smooth, heavy trowel consistency which will readily spread on and adhere to vertical and horizontal surfaces without sagging. 2. Character of Dried Film: Uniform, excellent adhesion to masonry, steel, cured concrete, shingles, asphalt roofing and a variety of other surfaces. 3. The dried film retains its flexibility and ductility so that the coating will resist extreme variations in temperature and weather. 4. Has excellent resistance to flow at high temperatures when used on a vertical surface. CAUTION: Do not use near open flame. Material is for building exterior applications only. Avoid breathing solvent fumes and prolonged contact with skin. Do not take internally. If swallowed, do not induce vomiting. Call a physician immediately. Keep out of reach of children. Keep container covered when not in use. Do not thin. Dispose of in an environmentally safe manner. Cover air intakes during application and while drying. PACKAGING: Available in 5 gallon, 3 gallon, 1 gallon cans and 10.1 oz. caulk tubes. If further information is needed, contact Karnak Technical Services at 1-800-526-4236. 0 momentull SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N] (732)902-6224 MOMENTUMSOLAR.COM f PROFESSIONAL ENGINEERING No PE86753 �O� ••. STATE OF 5 �oNAL JilI�N�`` I SOLAR CONTRACTOR CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC5703 MOMENTUM SOLAR 5728 MA70R BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION JOSE GIL- MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 (772)332-8075 PV SYSTEM INFORMATIOD SYSTEM SIZE (DC ): 11.2 KW 32 MODULES: LG LG 350N1C-V5 32 INVERTERS: ENPHASE IQ7PLUS-72-2-US PROJECT INFORMATION MN�AOE COUNTY HPNM.DECOIMIY INITIAL DATE: 7/14/2020 DESIGNER: SN KAM&MK330 CENTRAL AVENUE, CLARK, NJ 07066 REV: DATE: DESIGNER: 732-388-0300.800-526-4236 • FAX: 732-388-9422 REV: DATE: DESIGNER: Revised 12.14.18 WEB: http://www.kamakcorp.com SEALANT SPECIFICATION CON PV -3.8 DESCRIPTION: SNAPNRACK, CONDUIT SUPPORT COMP SHINGLE PART NUMBER(S): 242-02106 DRAWN BY: M.Watkins REVISION: DESCRIPTION: -SnupN ruck- SNAPNRACK, CONDUIT SUPPORT COMP SHINGLE PART NUMBER(S): 595 MARKET STREET, 29TH FLOOR F SAN FRANCISCO, CA 94105 USA PHONE (415) 580 -MO FAX (416) 5906902 THE NF9RIM110N N THIS pU1WIR0 UfgNF®B,RLLiY10 PPORUETMY.INY 242-02106 RWMWCNON, OIEQ08 . URU4ETKEREOF I9 PROHIAKEO W9H WT1RE WHrt1EH CCNNM OF WNNlN BWM LLC. 3 Karnak Application 1- Apply Karnak #19 (211 dob) ` 2- Press Firmly down on Shingles to spread Karnak #19 ,Y 4 MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, L FOOT FLASHING, 12IN X 12IN, BLACK GALV —2—Ti ; SNAPNRACK, CONDUIT SUPPORT STANDOFF SUBASSEMBLY' 3 1 SCREW, LAG, 5/16IN X 1-1/2IN, HEX, SS 4 1 SNAPNRACK, L FOOT BASE, MILL 6000 SERIES ALUMINUM, STAINLESS STEEL, ZINC PLATED STEEL, GALV STEEL N/A — -- - N/A LB -FT N/A - i PA # 8,539,719 r- —6.00 —12.00 DRAWN BY: M.Watkins SnupNrack- REVISION: A 595 MARKET STREET, 29TH FLOOR . SAN FRANCISCO, CA 04105 USA PHONE (415) 5504909 FAX (416) 5504902 RE WFORMATIW NTHI90MnWOle CORFlOENTLLL NVO PROPPIEfMT.TJIY EPRO WCTON, 0190.WIIRE, OR YeETNEREOF I9PHg1®ITER WIi11WT1XE W RIT1Bl C W BEM OF EUN PLR B W �H LLC. momentul SOLAR i PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAI 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N] (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING Illi►► A. / o PE86753 11.25 12.00 " * ' 7� 130�� STATE OF�� �Z' 'f 0NAL �E`� ��• I SOLAR CONTRACTOR 01.00 Z�-- 3.36_ 27 3.65 1.82 1.00 .02 2.00 ALL DIMENSIONS IN INCHES CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC5703( MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION JOSE GIL - MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 (772)332-8075 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 11.2 KW 32 MODULES: LG LG 350N1C-V5 32 INVERTERS:ENPHASE IQ7PLUS-72-2-US PR07ECTINFORMATION INITIAL DATE: 7/14/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: CONDUIT SUPPORT SPECIFICATION PV -3m9 ELECTRICAL SERVICE ELEVATION 32 LG LG 350N1C-V5 35OW MODULES PAIRED WITH 32 ENPHASE IQ7PLUS-72-2-US MICRO -INVERTERS MINUMUM BEN RADIUS 4" HOT LINE TAPS INTERCONNECTION DETAIL ENCLOSURE DIMENSIONS LENGTH: 21.31" WIDTH: 10.3" DEPTH: 9.06" #2/0 AWG SERVICE - CONDUCTOR FROM UTILITY METER FOR 200AMP SERVICE FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 (REVISED 7/1/2017), I, MINA A. MAKAR PE# 86753 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED PV SYSTEM CURRENT 48.4 A USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2017 BRANCH CIRCUITA 11 MICRO -INVERTERS BRANCH CIRCUIT B 11 MICRO -INVERTERS BRANCH CIRCUIT C + + 10 MICRO-INVERTERS- ENPHASE 80A - AC COMBINER BOX SOLAR CIRCUIT TERMINATION CAP DISCONNECTING MEANS INSTALLED ON + + - EATON 60A FUSIBLE END OF CABLE - _ _ ... = SOLAR AC DISCONNECT EXISTING SQUARE D 150A MAIN SERVICE PANEL 240 V MAIN BREAKER: 150A LINE SIDE -� HOT TAP +A i+ "' + �ROOF 10A BREAKER INVERTERS I JUNCTION (ENVOY)T I - POWER INSTALLED ON 1A TO 1C BOX 2A 20A BREAKER (A) 50A FUSES 'GROUND RAIL SYSTEM 3 4 2B 20A BREAKER (B) 2C 20A BREAKER (C) Wire Tag Conduit Wire Qty Wire Wire Type Temp' Wire Temp. Conduit Derated Inverter NOC (A) NEC Design Gauge Rating Ampacity (A) Derate Fill Derate Ampacity (A) Qty Correction Current (A) 1A TO 1C OPEN AIR 3 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 11 1.21 1.25 16.64 2A 1" PVC 2 10 AWG THWN-2 75•C 35 0.96 0.8 26.88 11 1.21 1.25 16.64 2B 1" PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 11 1.21 1.25 16.64 2C 1" PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 10 1.21 1.25 15.13 3 1" PVC 3 + G 06 AWG THWN-2 75°C 65 0.96 1 62.40 32 1.21 1.25 48.40 4 1" PVC 3+G 06 AWG THWN-2 75°C 65 0.96 1 62.40 32 1 1.21 1.25 48.40 NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. 0 momentum SOLA i - .. PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N] (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING IGEN 0 86753 ;• �4 0�••. STATE OF ' e -/;" ®NAL �N(` 11 I11 0711y�W�1Z GRID #2/0 AWG SERVICE • SOLAR CONTRACTOR - CONDUCTOR FROM ' L . • . • • Mme` . AISEA __ - - T _ OVERHEAD FOR ' • • '' • • '' _ •� ' 200AMP SERVICE 6306 EMERSON AVE • S • s 1 �• MSP w (772) 332-8075 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 11.2 KW '•'. Ground Wire .: .• of " • ._. . '• - 32 INVERTERS: ENPHASE '•' •,.COM R. • SOLAR ' ' , EXISTING • MEMIR 06 AWG MSP LOCATED INSIDE • BOX AC , , , •DISCON NECT • , • • .: PROJECT INFORMATION OF STRUCTURE INITIAL DATE: 7/14/2020 DESIGNER: SN ETHWN-2 REV: DATE: DESIGNER: 08 AWG REV: DATE: DESIGNER: 08 AWG THWN-2 THREE LINE DIAGRAM THWN-2 32 LG LG 350N1C-V5 35OW MODULES PAIRED WITH 32 ENPHASE IQ7PLUS-72-2-US MICRO -INVERTERS MINUMUM BEN RADIUS 4" HOT LINE TAPS INTERCONNECTION DETAIL ENCLOSURE DIMENSIONS LENGTH: 21.31" WIDTH: 10.3" DEPTH: 9.06" #2/0 AWG SERVICE - CONDUCTOR FROM UTILITY METER FOR 200AMP SERVICE FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 (REVISED 7/1/2017), I, MINA A. MAKAR PE# 86753 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED PV SYSTEM CURRENT 48.4 A USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2017 BRANCH CIRCUITA 11 MICRO -INVERTERS BRANCH CIRCUIT B 11 MICRO -INVERTERS BRANCH CIRCUIT C + + 10 MICRO-INVERTERS- ENPHASE 80A - AC COMBINER BOX SOLAR CIRCUIT TERMINATION CAP DISCONNECTING MEANS INSTALLED ON + + - EATON 60A FUSIBLE END OF CABLE - _ _ ... = SOLAR AC DISCONNECT EXISTING SQUARE D 150A MAIN SERVICE PANEL 240 V MAIN BREAKER: 150A LINE SIDE -� HOT TAP +A i+ "' + �ROOF 10A BREAKER INVERTERS I JUNCTION (ENVOY)T I - POWER INSTALLED ON 1A TO 1C BOX 2A 20A BREAKER (A) 50A FUSES 'GROUND RAIL SYSTEM 3 4 2B 20A BREAKER (B) 2C 20A BREAKER (C) Wire Tag Conduit Wire Qty Wire Wire Type Temp' Wire Temp. Conduit Derated Inverter NOC (A) NEC Design Gauge Rating Ampacity (A) Derate Fill Derate Ampacity (A) Qty Correction Current (A) 1A TO 1C OPEN AIR 3 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 11 1.21 1.25 16.64 2A 1" PVC 2 10 AWG THWN-2 75•C 35 0.96 0.8 26.88 11 1.21 1.25 16.64 2B 1" PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 11 1.21 1.25 16.64 2C 1" PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 10 1.21 1.25 15.13 3 1" PVC 3 + G 06 AWG THWN-2 75°C 65 0.96 1 62.40 32 1.21 1.25 48.40 4 1" PVC 3+G 06 AWG THWN-2 75°C 65 0.96 1 62.40 32 1 1.21 1.25 48.40 NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. 0 momentum SOLA i - .. PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N] (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING IGEN 0 86753 ;• �4 0�••. STATE OF ' e -/;" ®NAL �N(` 11 I11 0711y�W�1Z GRID SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57031 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 T CUSTOMER INFORMATION LA- JOSE GIL - MS52684 UTILITY 6306 EMERSON AVE METER FORT PIERCE, FL 34951 (772) 332-8075 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 11.2 KW Ground Ground Wire 32 MODULES: LG LG 350N1C-V5 Size Type 32 INVERTERS: ENPHASE IQ7PLUS-72-2-US 06 AWG BARE CU 08 AWG THWN-2 PROJECT INFORMATION 08 AWG INITIAL DATE: 7/14/2020 DESIGNER: SN ETHWN-2 REV: DATE: DESIGNER: 08 AWG REV: DATE: DESIGNER: 08 AWG THWN-2 THREE LINE DIAGRAM THWN-2 PV` PV -4.1 PV MODULE RATINGS INVERTER RATINGS MODULE MAKE LG VOLTAGE DROP CALCULATIONS INVERTER MAKE ENPHASE FORMULA USED PER NEC 2014 HANDBOOK 215.2(A)(4) WHERE APPLICABLE MODEL LG350N1C-V5 MODEL IQ7PLUS-72-2- WIRE RUN Vmp Imp R L (FT) VD W ® momentum IRE SIZE tum % V US o MAX POWER 35OW MAX OUTPUT POWER 290W BRANCH TO ]-BOX 240.00 13.31 1.98 72.42 3.817 1.59% 12 AWG SOLAR OPEN CIRCUIT VOLTAGE 41.3V OPEN DC VOLTAGE 60V 3 -BOX TO LOAD 240.00 38.72 1.24 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOL MPP VOLTAGE 35.3V NOMINAL AC VOLTAGE 240V CENTER 50.00 4.801 2.00% 10 AWG 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N] (732)902-6224 SHORT CIRCUIT CURRENT 10.61A LOAD CENTER TO AC DISCONNECT 240.00 48.4 0.491 3.00 0.143 0.06% 06 AWG MOMENTUMSOLAR.COM MAX AC CURRENT 1.21A PROFESSIONAL MPP CURRENT 9.92A CEC INVERTER EFFICIENCY 97% Ac DISCONNECT TO 240.00 ENGINEERING NUMBER OF MODULES 32 INTERCONNECTION 48.4 0.491 10.00 0.475 0.20% 06 AWG UL1703 COMPLIANT YES NUMBER OF INVERTERS 32 UL1703 COMPLIANT YES MAKE MODEL VOLTAGE CONDUCTOR CONDUCTOR RATING RANGE MAIN RANGE TAP SUB PANEL BREAKER # OF MODULES PV BREAKER PER BRANCH THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2017 FLORIDA BUILDING CODE AND THE 2014 NATIONAL ELECTRICAL CODE ILSCO IPC 4020 600 V 4/0-4 AWG 6-14 AWG SIZE UP TO 16 20A ILSCO IPC 4006 600 V 4/0-2 AWG 2/0-6 AWG J X1111 [ �e�`f 1. ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN��� 15. ALL p!-••• !q ��� CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED CONDUCTORS MUST BE COPPER. 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC `�� ••• y�G Ns� - •' :i ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE 16. COEFFICIENTS. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER MODULES WILL COMPLY WITH 250.64. '• NO PES6753 •: � v NEC 250.24(C). 30. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO NEC 690.46 - 250.120 (NEC 17. PARAGRAPH C). THE GROUND IS CARRIED AWAY FROM THE EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TOA GROUNDING IN THIS AC MODULE SYSTEM 690.17, 690.6. = • �A �, GROUNDING LUG USING #6 BARE COPPER WIRE OR #8 THWN-2 COPPER ELECTRODE SYSTEM PER 250.54(D). 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY ��Z •: i�,S •• STATE OF � •*• WIRE. 18. FUSES WITH 705.12(D)(3), 705.12(13)(2)(3)(6), 705.12(A) AS PERMITTED i "XOR1DN.•'• # •.•'"•"'' FOR PV DISCONNECT HAVE AIC RATINGS OF 200KAAC AND 20KA BY 230.86(6) /////'ONAL'��G�\ 3. THIS SYSTEM COMPLIES WITH NEC 2014 DC. 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION INSTRUCTIONS FOR LINE TAPS I� LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF D7J,a SHALL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. IN INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. FIGURE 1: ADDITION, VOLTAGE DROP CALCULATIONS FROM PANELS TO THE 1. ADJUST THE CONNECTOR NUT TO SUITABLE COMBINER BOX SHALL BE SHOWN IN A SIMILAR FASHION 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. LOCATION 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 21 • UTILITY HAS 24 -HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC 2. PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY 3. INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. INSULATED LAY IN THE MAIN CABLE, SHOULD STRIP A 6. ALL EQUIPMENT INSTALLED IS RATED AT 75°C 22. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL CERTAIN LENGTH OF THE FIRST INSULATED LAY SOLAR CONTRACTOR EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE FROM INSERTED END 7. INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM 110.26. 4 . TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR NUMBER: CVC5703! EQUIPMENT DATASHEET 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT SUITABLE LOCATION. 5. SCREW THE NUT WITH THE SLEEVE SPANNER. M SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION 8. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.8 (D). 6. SCREW THE NUT CONTINUALLY UNTIL THE TOP PART LOCAL AND NATIONAL CODE REQUIREMENTS. 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE IS CRACKED AND DROPPED DOWN JOSE GIL - MS52684 6306 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). EMERSON AVE FORT PIERCE, FL 34951 INSTRUCTIONS 25. TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT 772) 332-8075 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D) ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE PV SYSTEM INFORMATION CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(2). SYSTEM SIZE (DC): 11.2 KW 11. .1 PER NEC 690.17, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE .�,,, 32 MODULES: LG LG 350N1C-V5 TERMINALS THE DISCONNECTING MEANS MAY BE ENERGIZED IN 26. F THE SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC ~• 32 INVERTERS: ENPHASE > THE OPEN POSIGN SHALL READ *WARNING - ELECTRIC SHOCK CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, IQ7PLUS-72-2-US HAZARD - DO NOT TOUCH TERMINALS - OR EQUIVALENT. DISCONNECT. AND COMPLIES WITH 690.6 - NO DC DISCONNECT AND - ASSOCIATED DC LABELING ARE REQUIRED. 12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY 27. SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED PROJECT INFORMATION INITIAL DATE: AT SERVICE ENTRANCE. LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING 7/14/2020 DESIGNER: SN CURRENT SHALL BE PROVIDED 690.52. REV: DATE: DESIGNER: 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 690.64 REV: DATE: DESIGNER: 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO AND NOT PV SOURCE CIRCUITS. 690.6. ELECTRICAL NOTES SUB -CIRCUIT BRANCHES IS ACCEPTABLE. PV -4.1 I ,lw 1@1 1192 EXAMPLES �P e :ammr W 1O momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N] (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING f la►• , A � �i •.•No PE86753 �.� • lee z: AV 0 STATE OF �s // 0iVAl- !Ilii I SOLAR CONTRACTOR CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC5703 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATIOP JOSE GIL - MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 (772) 332-8075 PV SYSTEM INFORMATIOP SYSTEM SIZE (DC): 11.2 KW 32 MODULES: LG LG 350N1C-V5 32 INVERTERS: ENPHASE IQ7PLUS-72-2-US O PROJECT INFORMATION INITIAL DATE: 7/14/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: EQUIPMENT LABELS PV -4.2 MAIN SERVICE PANEL bWARNIN , WARNING • O THIS EQUIPMENT FED PHOTOVOLTAIC POWER SOURCE BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING COMBINER BOX] MAIN SUPPLY PHOTOVOLTAIC SYSTEM OVERCURRENT DEVICE, SHALL NOT EQUIPPED WITH EXCEED AMPACITY OF BUSBAR. RAPID SHUTDOWN OWARNING O ELECTRICAL SHOCK HAZARD JUNCTION : • DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PHOTOVOLTAIC SOLAR AC A�WARNINGDISCONNECT OPERATING CURRENT 38.72A ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS OPERATION VOLTAGE 264 V TERMINALS ON BOTH LINE AND O LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION AC DISCONNECT INSTALLED BY MOMENTUM SOLAR 325 HIGH STREET METUCHEN, NJ 08840 PHONE NUMBER: 732-902-6224 LINE SIDE TAP z j /WA R N I N G © DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM DISCONNECTMAIN PANEL NOMINAL AC OPERATING VOLTAGE 240 V RATED AC OPERATING CURRENT38.72A OWARNING O DUAL POWER SOURCE UTILITY METER SECOND SOURCE IS PHOTOVOLTAIC SYSTEM I ,lw 1@1 1192 EXAMPLES �P e :ammr W 1O momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLA 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N] (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING f la►• , A � �i •.•No PE86753 �.� • lee z: AV 0 STATE OF �s // 0iVAl- !Ilii I SOLAR CONTRACTOR CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC5703 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATIOP JOSE GIL - MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 (772) 332-8075 PV SYSTEM INFORMATIOP SYSTEM SIZE (DC): 11.2 KW 32 MODULES: LG LG 350N1C-V5 32 INVERTERS: ENPHASE IQ7PLUS-72-2-US O PROJECT INFORMATION INITIAL DATE: 7/14/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: EQUIPMENT LABELS PV -4.2 Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd. Skillman NJ. 08558 908-872-3664 StudioGdesign@comenst.net July 14, 2020 Re: Proposed Photovoltaic Solar Panel Installation Jose Gil 6306 EMERSON AVE FORT PIERCE, FL 34951 Dear Plan Reviewer: Certification: I have reviewed the engineering testing reports for the racking and attachments to be used on this project and 1 certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that an inspection was performed by a representative of the Architect/Engineer of Record, and analysis of the existing structure was conducted. There is adequate structural capacity for the installation of the array with the following recommendations: 1. The array will be installed on the existing roof. The roof framing is constructed of 2"x4" wood trusses @24" o.c. spanning 12'1(" with a top chord length of 147 with intermediate supports at 1/2 points, making the effective longest span equals 7'5" with 1/2" plywood sheathing. The new array (See Site map by contractor) will add 2.63 Lb. / SE overall to the roof. No additional structural support is required for the roof structure. 2. The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed instructions. The attachment system shall be UL 1703 approved tested. Provide 6 mil. vapor barrier between dissimilar metals. Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual. The panel angle shall match the roof slope. Reference summary table below: Roof T Shinale I Fastener Max S acin (in. ) Attachment System: "SnapNrack" "Ultra Rail" ® wind zone Iwind zone 2 wind zone 3 Fastener htfo: min. 5/16" x 4" long stainless-steel lags with a min. 72 48 0 embedment of 3" into the rafters i 3. Solar Modules shall be UL -1703 rated. Refer to manufacturers specifications sheets. 4. Positive drainage of the system shall be so as not to void the existing roof warranty. 5. All aspects of the installation shall comply with the Florida Administrative Code, 2017 Florida Building Code - Residential Sixth Edition, ASCE-7-10, 2017 Florida Building Code - Energy Conservation, Sixth Edition, 2014 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. All components used meet the criteria of the Florida Solar Energy Center. 6. Please refer to the attached structural calculations. If you have any questions relating to this matter, please contact me at your earliest convenience. Thank you. ,i Daniel W. Dunzik, RA. LEED-AP FL. Lic. No. AR98795 Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd. Skillman NJ. 08558 908-872-3664 StudioGdesign@comcast.net July 14, 2020 Gravity Load Calculation Criteria Structural Design Loads per ASCE 7-10 Dead Loads = 10 psf + 2.6 psf (new solar panels) = 12.6 psf Roof Live Load = 20 psf Ground Snow Load = 0 psf Wind Load Calculation Criteria Wind Loads per ASCE 7-10, Ch. 30 method 1 Using an area of 10 SF, wind loads from Figure 30.5-1: Zone 1 = -42.1 psf Roof Slope = 23 degrees Roof Mean Height = 15 ft Zone 2 = -73.4 psf Basic Wind Speed = 160 mph Zone 3 = -108.5 psf Exposure = B Per section 2.4.1, ASD combo = D + 0.6W: Zone I = 2.6 psf + 0.6(-42.1 psf) = -22.7 psf Zone 2 = 2.6 psf+ 0.6(-73.4 psf) = -41.4 psf Zone 3 = 2.6 psf+ 0.6(-108.5 psf) = -62.5 psf Check Attachment to Wood Truss Use 5/16 dia. Lag screw w/ 3" embedment into 2 in. wide roof rafter Lag Screw Spacing: Lag Screw Tributary Area: Zone 1 = 72" o.c. max Zone 1 = (72" o.c. max)12 / 144 = 36 SF Zone 2 = 48" o.c. max Zone 2 = (48" O.C. max)A2 / 144 = 16 SF Zone 3 = 0" o.c. max Zone 3 = (0" o.c. max)A2 / 144 = 0 SF Lag Screw Forces: W = 26616/in (Table 12.2A, 2015 NDS) Zone 1 = 22.7 psf x 36 SF = 817 lb < W', OK Cd = 1.6 (Table 2.3.2, 2015 NDS) Zone 2 = 41.4 psf x 16 SF = 662 Ib < W', OK Ct = 1 (Table 2.3.3, 2015 NDS) Zone 3 =62.5 psf x 0 SF = O lb < W', OK W = W x embed x Cd x Ct W'= 266 lb/in x 3 in. x l .6 x 1 = 1276.8 lb (lsj) momentuffz SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N] (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING `� ill ll►/� ``� ♦ •' �.10EN •• i No PE86753 0. STATE OF //;s� OVAL 1�%N���`` Illll 07/1 --� SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION JOSE GIL - MS52684 6306 EMERSON AVE FORT PIERCE, FL 34951 772) 332-8075 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 11.2 KW 32 MODULES: LG LG 350N1C-V5 32 INVERTERS:ENPHASE IQ7PLUS-72-2-US PRO3ECTINF00MATION INITIAL DATE: 7/14/2020 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: STRUCTURAL CERTIFICATION PV+ 5