FL # 083=R
Application Type Revisio
Code Version 2017
Application Status Approved
Comments
Archived I_I
Product Manufacturer Carlisle SynTec Systems
Address/Phone/Email 1285 Ritner Highway
P.O. Box 7000
Carlisle, PA 17013
(717)245-7000
malpezzl@syntec.carlisle.com
Authorized Signature Joe Malpezzi
malpezzl@syntec.carlisle.com
Technical Representative Robert Patton
Address/Phone/Email 1555 Ritner Highway
Carlisle, PA 17013
(717) 245-7264
Robert.PAT'rON@syntec.carlisle.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Single Ply Roof Systems
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
I_I Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed V ® 7 x9lf r✓
the Evaluation Report (� I /1 i�
Florida License v�E-�1/6�6 v0/t�h®I`®�
Quality Assurance Entity UL Ll�./�1' rY��"�'/1
Quality Assurance Contract Expiration Date 04/07/2 '3'''(}:cCPU,
'H1%�0 O
Validated By J+Ihn WVa elation Ch li �ardtol5y Received
Certificate of Independence FL14083 R23 COI 2020 01 COI NIEMINEN p)f
Referenced Standard and Year (of Standard) Standard Year
ASTM D6878 F/Lie 2011
Page 1 of 2
Florida Building Code Online
6/30/20, 7:39 PM
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
FM 4470
2012
FM 4474
2011
TAS 131
1995
UL 1897
2012
Method 1 Option D
04/06/2020
04/07/2020
04/14/2020
06/02/2020
06/09/2020
FL #
Model, Number or Name
Description
14083.1
Carlisle Sure -Weld TPO Single Ply
Thermoplastic Olefin (TPO) Single Ply Roof Systems
Roof Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
F1,14083 R23 II 2020 04 03 FINAL Al ER FL14083-
R23.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
VeriFled By: Robert J. M. Nieminen PE - 59166
Design Pressure: +N/A/-722.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application relates to
Evaluation Reports
one particular assembly. Refer to the ER Appendix all systems
FL14083 R23 AE 2020 04 03 FINAL ER FL14083-1123.0f
Created by Independent Third Party: Yes
max. design presssures. 2.) Refer to ER, Section 5 for Limits
of Use. 3.) This Product Approval is for Non-HVHZ
jurisdictions: Refer to FL16440 for HVHZ.
Sack Next
ContactUs c 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 8SO 487-1824
The State of Florida Is an ANEW employer. Coovdoht 2007-2013 State of Flo[ :: Pdvacv Statement :: Accessibility Statement ❑ Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395, -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made avallable to the public. To determine if you are a licensee under Chapter
455, F.S., please click here.
Product Approval Accepts:
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=WGEVXQwtDgtGLR%2byCBylJmTUImMQIToYlue4MuTwiz5ZgNG7iaPovw%3d%3d Page 2 of 2
System Deck
No. (Note 1) Insulation Layer
Fasteners
Attachment
"NEMOletc.
Road Cover I MDP
(Pso
Min. 15/32-inch
(Optional) One or more layers, any
Carlisle HP-X Fastener and
1 per 6 ft'
Sure -Weld or Sure -Weld EXTRA bonded to RHINOBOND
W-26,
plywood or
combination, loose laid
RHINOBOND Insulation Plate (TPO) or
(2 z 3 ft grid pattern)
Insulation Plate (TPO) or RHINOBONDTreadSafe Plate (TPO)
-22.5
wood plank
RHINOBOND TreadSafe Plate (TPO)
with RHINOBOND tool per manufacturer's instructions.
Min. 15/32-inch
(Optional) One or more layers, any
Carlisle HP-X Fastener and
1 per 4.0 h r
Sure -Weld or Sure -Weld EXTRA bonded to RHINDBOND
W-27.
plywood or -
_
combination, loose laid
...... RHINOBOND Insulation Plate (TPO) or
,,___„_ __ ,_ _ _, , ,__,
(2 z 2 It erid pattern)
Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO)
-30.0
Min. 15/32-inch
(Optional) One or mare layers, any
Carlisle HP-X Fastener and
1 per4.0 ft'
Sure -Weld or Sure -Weld EXTRA bonded to RHINOBOND
LW-28
plywood or
combination, loose laid
RHINOBOND Insulation Plate (TPO) or
(2 x 2 It grid pattern)
Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO)
-37.5-
wood plank
RHINOBOND TreadSafe Plate (TPO)
with RHINOBOND tool per manufacturers instructions.
rn. -rnc
(Optional) One or more layers, any
isle - Fastener an
1 per 6 ft'
sure -Weld orSure-Weldone o
W-29.
plywood or
combinatipn, loose laid
RHINOBOND Insulation Plate (TPO) or
(2 z 3 It grid pattern)
Insulation Plate (TPO) or RHINO BOND TreadSafe Plate (TPO)
-45.00
wood plank
RHINOBOND TreadSafe Plate (TPO)
With RHINOBOND tool per manufacturers instructions.
Min. 15/32-inch
(Optional) One or more layers, any
Carlisle HP-X Fastener and
1 per 2.7 ft'
Sure -Weld or Sure -Weld EXTRA bonded to RHINOBOND
W-30.
I
plywood or
combination, loose laid
RHINOBOND Insulation Plate (TPO) or
(12 parts per4x8 ft board)
Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO)
-05.0
wood plank
RHINOBONDTreadSafe Plate (TPO)
with RHINOBOND tool per manufacturers instructions.
Min. 15/32-inch
(Optional) One or more layers, any
Carlisle HP-X Fastener and
6-inch o.c. in rows 60-inch
Sure -Weld or Sure -Weld EXTRA bonded to RHINOBOND
W-31.
plywood or
combination, loose laid
RHINOBOND Insulation Plate (TPO) or
Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO)
-60.0
Carlisle HP-X Fastener and
o
Sure -Weld or Sure -Weld EXTRA bonded to RHINDBOND
Min. 19/324nch
(Optional) One or more layers, any
1 per 2.7 hz
W-32.
plywood or
combination, loose laid
RHINOBOND Insulation Plate (TPO) or
(12 parts per 4xB ft board)
Insulation Plate (TPO) or RHINOBOND TreadSafe Plate (TPO)
-67.5
wood plank
RHINOBOND TreadSafe Plate (TPO)
with RHINOBOND tool per manufacturers instructions.
NEMO ETC, LLC Evaluation Report C33680.09.10-R23 for FL14083-1123
Certificate of Authorization 832455 6M EDITION (2017) FBC NON-HVH2 EVALUATION Revision 23: 04/03/2020
02019, NEMO ETC, LLC Carlisle Sure -Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 8 of 86
i
SYNTEC SYSTEMS
HP-X FastenersTM and Rhino6ond® Plates
Overview
Carlisle HP-X Fasteners are used with Carlisle's TPO or PVC RhinoBond
Fastening Plates to secure Sure -Weld® TPO and Sure -Flex'" PVC roofing
membranes. The HP-X Fastener may be used on 20-gauge (0.91 mm) or
22-gauge (0.76 mm) steel or wood decks (minimum "/32" [12 mm] COX
plywood). The HP-X Fastener is designed to offer an optimum combination
of driving performance, back -out and corrosion resistance with excellent
pullout values. The RhinoBond TPO or PVC Fastening Plate is designed
to attach the roofing membrane from the underside using the RhinoBond
induction -welding tool.
Features and Benefits
a Reduces the number of fasteners and plates compared with
conventional mechanically attached applications
D No perimeter sheets required
» Faster dry -in time
a Non -penetrating system
• Even load distribution across membrane
Installation
No pre -drilling is necessary for woad and steel decks. Simply insert the
HP-X Fastener through the Carlisle RhinoBond plate and install with a
standard clutch drive electric screw gun (0-2500 rpm). Optimum fastener
performance is achieved when the fastener is installed perpendicular to
the deck and into the top flutes of a steel deck. Follow RhinoBond System
installation instructions to attach the membrane to the installed plate using
the RhinoBond portable induction tool.
Keep insulation substrate and membrane clean. Any debris on the top of
the insulation substrate and/or the membrane should be removed prior
to initiating the induction welding process. Use a leaf blower or broom to
eliminate any debris from the membrane surface.
Keep magnets clean. If a metal shard or other debris from the roof sticks
to the magnet, it can cause damage to the membrane surface in the weld
area. Periodically ensure there are no contaminants on the bottom side of
the magnet.
Review Carlisle specifications and details for complete installation
information.
Precautions
n Eye protection is recommended during installation.
Use care to avoid over -torquing the fastener.
» Do not expose plates to UV for extended periods.
PropertiesTypical
Size Inch (ram) Weight/Ctn(Kg)
Thread Length
Inch (mm)
Packaging
Fasteners/Cin.
2 (50)
20 fibs (9.1)
Full
1,000
l 3 (80)
291bs (13.1)
3 (75)
1,000
1 4 (110)
381bs (17.2)
4 (100)
1,000
5 (130)
471bs (21.3)
4 (100)
500
6 (150)
56 Ibs (25.4)
4 (100)
500
7 (175)
33 Ibs (15.0)
4 (100)
500
8 (200)
38 lbs (17.2)
4 (100)
500
10 (250)
46 Its (20.9)
4 (100)
500
12 (300)
55 Ibs (24.9)
4 (100)
500
! 14 (355)
651bs (29.5)
4 (100)
500
1 Plates
31/8.(80) 361bs(16.0) — 500
Steel Deck
22.Gauge or 20 Gauge
Wood Deck
Min..15/32"
Typical Pull-out Value
710 lbf(3158 N) 22 gauge
375 lbf(1668 N)
Minimum Penetration
3/a" (19 ram)
1" (25 mm)
Maximum Penetration
4" (100 mm)
4" (100 mm)
Typical Static Back -out
15.1 in Ibs (1.7 N-m)
N/A
I Typical Drill Times
1.5 seconds - 20 gauge
N/A
Tvoical Drooenies and characteristics are based an samples
for all samples at this product. This data and Information Is intended as a guide and does not
reflect the specification range for any particular property of this product.
800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-245-7053 1 www.carlislosyntec.com
02.01.19 ® 2019 Carlisle. Carlisle, HP-x Fasteners, Sure -Flex and Sure -Weld are trademarks of Cadlsle.
REPRINT CODE: 6051136 - "HPA Fasteners and RhinoBond Plate Product Data Sheet" ehlnollond Is a registered trademark of OMG, Inc. and is patent protected.
IlnsulBase' POLYISO
Insulation
Overview
InsulBase is a rigid -roof insulation panel composed of a closed -cell
polyisocyanurate foam core bonded on each side to glass -reinforced
felt (GRF).
Features and Benefits
» InsulBase polyiso insulation provides the highest R-value per inch of
commercially available insulation products
» Environmentally friendly construction with 0% ozone -depleting
components and CFC free
» Approved for direct application to steel decks
Panel Characteristics
» Available in 4' x 4' (1220 mm x 1220 mm) 4' x B' 20 mm x 2440
mm) panels in thickness of Y2" (13 mm) to 4. )
Applications
» Single -Ply Roof Systems (Ballasted, Mechanically Attached,
Fully Adhered)
i
SYNTEC SYSTEMS
InsulBase Polyiso Thermal Values
Thickness Thickness LTTR Flute
(inches) (MM) R-value Spanability
0.50 13 2.8 2 W
1.00 25 5.7 2'A"
1.50 38 8.6 4'W
2.00
2.50
51
64
11.4
14.4
4'/V
4 W
3.00
76
17.4
4 W
3.50
89
20.5
4 W
4.00
102
23.6
4'W
4.50
114
26.8
4'W
Installation
Ballasted Single -Ply Systems
Each InsulBase panel is loosely laid on the roof deck. Butt edges and
stagger joints of adjacent panels. Install the roof membrane according to
Mechanically Attached Single -Ply Systems
InsulBase panels must be secured to the roof deck with fasteners and
plates (appropriate to the deck type). Butt edges and stagger joints
of adjacent panels. Install the roof membrane according to Carlisle's
specifications.
InsulBase panels must be secured to the roof deck with fasteners and
plates (appropriate to deck type). Butt edges and staggerjcints of adjacent
panels. Install the roof membrane according to Carlisle's specifications.
InsulBase 4' x 8' panels can be secured to the roof deck with Carlisle's
FASrAdhesive, either full coverage or bead spacing.
InsulBase 4' x 4' panels may be adhered to prepared concrete deck with a
full mopping of Type III or IV asphalt.
Review Carlisle specifications and details for complete installation
information.
800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-245-7053 1 www.carlislesyntec.com
IInsulBase POLYISO
Insulation
Codes and Compliance
» ASTM C1289, Type II, Class Grade Pon
rade 3 (25 psi)
» International Building Code (IBC) ec
» UL Standard 790, 263 and 1256: Component of Class A Roof Systems
(refer to UL Roof Materials' system directory)
» FM® Standards 4450/4470: Class 1 approval for steel roof -deck
constructions (refer to FM RoofNavBN)
» California Code of Regulations, Title 24, Insulation Quality Standard
License #TI-1418
» Third -party certification with the PIMA Quality Mark for Lang -Term
Thermal Resistance (LTTR) values
» CAN/ULC S704, Type 2 & 3, Class 2
» Florida Building Code Approval
Precautions
Insulation must be protected from open flame and kept dry at all times.
Install only as much insulation as can be covered the same day by
completed roof -covering material. Protect installed product from excessive
foot traffic. Carlisle will not be responsible for specific building and roof
design by others, for deficiencies in construction or workmanship, for
dangerous conditions on the job site or for improper storage and handling.
Technical specifications shown in this literature are intended to be used
as general guidelines only and are subject to change without notice. Call
Carlisle for more specific details, or refer to PIMA Technical Bulletin No.
109: Storage & Handling Recommendations for PDlyiso Roof Insulation.
i
BYNTEC 8Y6TEM8
PropertiesTypical
Physical Property
Test Method
Value
' Compressive Strength
ASTM D1621
20 psi' minimum
(138 kPa, Grade 2)
Dimensional Stability
ASTM D2126
2% linear change (7 days)
I Moisture Vapor Permeance
ASTM E96
<1 perm
(57.5 ng/(Pa•s•ma))
Water Absorption
C1763
<1%volume
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product. This data and Information is intended as a guide and does not
reflect the specification range for any particular property of this product.
'Also available in 25 psi minimum, Grade 3
�$SIFj� Foamed plastic as roof deck construction material with
4 O resistance to an intemal fire exposure only for use in
®U� constmctlon no.(s)120 and 123. See UL Directory of
C us Products Certified for Canada and UL Roofing Materials
and Systems Directory. 99DL
0 PI ',Mark"
The Certified LTrR-value
800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-246-7053 1 www.carilsiesyntee.com
12.04.18 ® 2018 Carlisle. Carlisle, SecurShleld, Insul Base and FAST are trademarks of Carlisle.
REPRINT CODE: 800491- "Insumase Polylso Product Data Sheet"
ISure-Weldo TPO
Reinforced Membrane
Overview
Carlisle's Sure -Weld TPO reinforced membrane is a premium, heat -
weldable, single -ply thermoplastic polyolefin (TPO) sheet designed for new
roof construction and re -roofing applications. Sure -Weld High Slope (HS)
membrane is formulated with additional flame retardant for higher -slope
fire code approvals. Sure -Weld EXTRA is 80 mils thick for significantly
higher strength and weatherability.
Sure -Weld TPO membranes use advanced polymerization technology
that combines the flexibility of ethylene -propylene (EP) rubber with the
heat weldability of polypropylene. All Sure -Weld TPO membranes include
OctaGuard XT, an industry -leading, state-of-the-art weathering package.
OctaGuard XT technology enables Sure -Weld TPO to withstand the extreme
weatherability testing that is intended to simulate exposure to severe climates.
Physical properties of the membrane are enhanced by a strong polyester
fabric that is encapsulated between the TPO-based top and bottom plies.
The combination of the fabric and TPO plies provides high breaking and
tearing strength, as well as excellent puncture resistance. The relatively
smooth surface of the membrane produces a total surface fusion weld
that results in a consistent, watertight, monolithic roof assembly. The
membrane is environmentally friendly and safe to install.
Carlisle's standard and HS TPO membranes are available in highly reflective
white, tan, and gray, in both 45-mil and 60-mil thicknesses. 80-mil
Sure -Weld EXTRA (including HS) is also offered in white, gray, and tan colors.
Special color Sure -Weld HS TPO membranes are also available (see Carlisle's
TPO Color Palette brochure). Carlisle's TPO is offered in 4-, and 6-ft
perimeter sheets and 8-,10-, and 12-ft Sure -Weld field sheets. Sure -Weld
HS and special color TPO membranes are available in limited sizes.
Carlisle's tan and white TPO membranes are ENERGY STAR® -qualified and
California Title 24 compliant and can contribute toward LEED® (Leadership
in Energy and Environmental Design) credits.
i
SYNTEC SYSTEMS
Productivity Boosting Features and Benefits:
Optional APEEL Protective Film
CI
ptlVlTy
Carlisle's Sure -Weld TPO reinforced membrane is o
available with an optional APEEL Protective Film, a.Qsaving time and labor by eliminating the need forroof cleaning upon project completion. Carlisle's Q,
innovative APEEL Protective Film can be left in s000
place for up to 90 days without affecting the
integrity of the film, guarding the TPO membrane's surface from scuffs
and dirt accumulation'during installation. Durable and easy to remove,
APEEL Protective Film improves aesthetics and long-term reflectivity
and is ideal for re -roofing, re-cover, and new construction projects.
OO EICTFISUFIRO XTCL
Features and Benefits
Outstanding puncture resistance
n Excellent fire resistant assemblies
v Environmentally friendly and stable formulation
Excellent resistance to impact and low temperatures
u Excellent chemical resistance to acids, bases and restaurant exhaust
emissions
D UL 2218 Class 4 hail rating
• Exceptional resistance to heat, solar UV, ozone and oxidation
u Manufactured using a hot -melt extrusion process for complete scrim
encapsulation
R 100% recyclable (see Carlisle's Recyclability Statement)
Enhanced with the OctaGuard XT weathering package
APEEL Protective Film application guards the TPO membrane's
surface from scuffs and dirt accumulation during installation,
improving the roof system's appearance and long-term performance
v APEEL Protective Film can be left in place for up to 90 days without
degrading due to its excellent heat- and UV -resistance
800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-245-7053 1 www.carlislesyntee.com
Sure -Weld TPO
Reinforced Membrane
Installation
1. Sure -Weld TPO roofing systems are quick to install, as minimal labor
and few components are required. TPO systems are installed using an
Automatic Heat Welder, making sheet welding fast, clean, consistent,
and easy to learn, while reducing strain on the roofing technician.
2. APEEL Protective Film should be removed from within areas that
are to be heat -welded together. In areas that do not require heat -
welding, the APEEL Protective Film can be left in place for up to
90 days. When the installation of the entire TPO roofing system is
complete, remove and discard the APEEL Protective Film.
3. The Carlisle Mechanically Fastened Roof System installation
starts by fastening the insulation with a minimum of 4 fasteners per
4' by 6' board. The membrane is mechanically fastened to the deck
using HP-X- Fasteners and Piranha Plates"" or HP-XTRA Fasteners
and Piranha XTRA Plates. Adjoining sheets of membrane are
overlapped over the fasteners and plates and joined together with a
minimum 1%2"-wide (4 cm) hot-air weld.
PropertiesTypical
Physical Property
ASTM D6878 Requirement
45-mil
60-mil
80-mil EXTRA
Tolerance on Nominal Thickness, %ASTM D751 test method
+15, -10
± 10
± 10
±10
Thickness Over Scrim, in. (mm)
0.015 min
0.018 typical
0.024 typical
0.034 typical
ASTM D7635 optical method, average of 3 areas
(0.380)
(0.457)
(0.610)
(0.864)
Breaking Strength, Ibf (M)
220 (976 N)
225 (1.0) min
250 (1.1) min
350 (1.6) min
ASTM D751 grab
min
320 (1.4) typical
360 (1.6) typical
425 (1.9) typical'
Elongation Break of Reinforcement, %
15 min
15 min
15 min
15 min
ASTM D751 grab method
25 typical
25 typical
25 typical
Tearing Strength, Ibf (N)
55 (245) min
55 (245) min
55 (245) min
55 (245) min
ASTM D751 proc. B 8 in. x 8 in.
130 (578) typical
130 (578) typical
130 (578) typical
Brittleness Point, °F rC)
-40 (-40) max
-40 (40) max
-40 (-40) max
-40 (40) max
ASTM D2137
-50 (46) typical
-50 (-46) typical
-50 (46) typical
Linear Dimensional Change, %
±1 max
±1 max
±1 max
±1 max
ASTM DI204, 6 hours at 1580F
-0.2 typical
-0.2 typical
-0.2 typical
Ozone Resistance, no cracks 7X ASTM D1149, 100 pphm, 168 bra
PASS
PASS
PASS
PASS
Water Absorption Resistance, mass %
± 3.0 max
± 3.0 max
. 3.0 max
± 3.0 max
ASTM D471 top surface only 166 hours at 158°F water
0.90 typical
0.90 typical
0.90 typical
' Factory Seam Strength, Ibf (N) ASTM D751 grab method
66 (290) min
66 (290) min
fib (290) min
fib (290) min
Field Seam Strength, Iof/In (kN/m)
No requirement
25 (4.4) min
25 (4.4) min
40 (7.0) min
ASTM D1876 tested in peel
50 (8.8) typical
60 (10.5) typical
70 (12.3) typical
• Water Vapor Permeance, Perms
No requirement
0.10 max
0.10 max
0.10 max
ASTM E96 proc. B
0.05 typical
0.05 typical
0.05 typical
Puncture Resistance, Ibf (kN)
No requirement
250 (1.1) min
300 (1.3) min
400 (1.8) min
i FTM 101 C, method 2031 (see supplemental section)
325 (1.4) typical
350 (1.6) typical
450 (2.0) typical
Properties After Heat Aging
ASTM D573, 32 weeks ® 240OF or 8 weeks ® 275°F
PASS
PASS
PASS
PASS
No cracking when bent around 3" diameter mandrel
No cracking
No cracking
No cracking
No cracking
Weight Change, %
± 1.5 max
1.0 max
1.0 max
1.0 max
Typical Weights Ib/flz (kg/mi
0.23 (1.1)
0.29 (1.4)
0.40 (2.0)
Typical properties and characteristics are based an samples tested and are not guaranteed for all samples of this product This data and Information is intended as a guide and does not reflect the
specification range for any particular property of this product.
(Sure -Weld TPO
Reinforced Membrane
4. The Carlisle Fully Adhered Roofing System installation begins by
fastening the insulation at the required density necessary to meet
the appropriate warranty or wind load requirement. The substrate
and membrane are then coated with an appropriate Sure -Weld TPO
bonding adhesive and the membrane is rolled into place.
Review Carlisle specifications and details for complete installation
information.
Precautions
» Sunglasses that filter out ultraviolet light are strongly recommended, as
tan and white surfaces are highly reflective. Roofing technicians should
dress appropriately and wear sunscreen.
» Surfaces may become slippery due to frost and ice buildup. Exercise
caution during cold conditions to prevent falls.
» Care must be exercised when working close to a roof edge when
the surrounding area is snow-covered, as the roof edge may not be
clearly visible.
» Use proper stacking procedures to ensure sufficient stability of the rolls.
» Exercise caution when walking on wet membrane. Membranes may be
slippery when wet.
» Store membrane in the original undisturbed plastic wrap in a cool,
shaded area and cover with light-colored, breathable, waterproof
tarpaulins. Membrane that has been exposed to the weather must be
prepared with Weathered Membrane Cleaner prior to hot-air welding.
» Take care not to stand or place heavy objects on the edge of folded -
over membrane, as this could cause a hard crease in the membrane.
» Maximum sustained temperature not to exceed 160°F (71°C) for TPO
membrane.
» Do not use razor blades or other sharp tools to cut the APEEL Protective
Film while it is still adhered to the TPO membrane as damage to the
underlying membrane may occur. Pull the protective film away from the
membrane prior to cutting.
» Remove APEEL Protective Film by pulling towards the center of the
roof. Do not remove the film by pulling towards the roof edge.
» A static electric charge may develop when removing APEEL Protective
Film from the surface of the membrane sheet. To avoid the possibility
of ignition, lids must be closed on any flammable products and a fire
extinguisher should be readily available.
» Color membranes will 'fade' overtime mainly due to the ultraviolet
portion of sunlight. Since most roof surfaces are exposed to variable
sunlight, some areas will be more susceptible to color changes caused by
UV fading. Warranties for color membranes do not cover fading of colors.
i
SYNTEC SYSTEMS
EXTREME Testing for Severe Climates
ASTM Standard D6878 is the material specification for Thermoplastic
Polyolefin-Based Sheet Roofing. It covers material property requirements
for TPO roof sheeting and includes initial and aged properties after heat
and xenon -arc exposure. As stated in the scope of the standard, "the tests
and property limits used to characterize the sheet are values intended to
ensure minimum quality for the intended purpose." Carlisle's goal is to
produce TPO that delivers maximum performance for the intended purpose
of roofing membranes. Maximum performance requires the membrane to
far exceed the requirements of ASTM D6878.
Heat Aging accelerates the oxidation rate that roughly doubles for each
1 B°F (1 DOC) increase in roof membrane temperature. Oxidation (reaction
with oxygen) is one of the primary chemical degradation mechanisms of
roofing materials.
Carlisle Testing — Heat Aging
ASTM Requirement Sure -Weld Requirement
ASTM TEST 32 weeks" >128 weeks
240°F
..Heat exposure comparable to 3,120 weeks (60 years) at 185OF for 8 hours/day.
» Test specimen is a 2" by 6" piece of 45-mil membrane unbacked,
placed in circulating hot-air oven.
» Criterion— no visible cracks after bending aged test specimen around
3"-diameter mandrel.
Q-Trac testing combines accelerated weathering with real -world conditions
using an array of ten mirrors to reflect and concentrate full spectrum
sunlight onto membrane test specimens. The Q-Trac device automatically
tracks the sun's path from morning to night. Also, it adjusts to compensate
for seasonal changes in the sun's altitude. Eight years in Q-Trac testing is
equal to 40 years of real -world exposure. Carlisle requires its Sure -Weld
TPO membranes to pass the equivalent of 40 years of exposure in the Q-Tmc
I ASTM D6878 Requirement Sure -Weld Requirement
ASTM TEST WA Equivalent of 40 years
j N/A of exposure
Environmental Cycling subjects the membrane to repeated cycles of heat
aging, hot-water immersion, and xenon -arc exposure.
» ASTM requirement — none
» Carlisle EXTREME test':
10 days heat aging at 240OF (116°C) followed by
800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-245-7053 1 www.carlislesyntec.com
Sure -Weld TPO
Reinforced Membrane
- 5 days water immersion at 158"F (70°C) followed by
- 5,04O kJ/m2 (2000 hours at 0.70 W/m2 irradiance) xenon -arc
exposure
'Test specimen is 2.75" by 5.5" piece of membrane with edges sealed.
'Criterion - after 3 complete cycles, test specimens shall remain
flexible and not have any cracking under 1Ox magnification while
wrapped around a 3"-diameter mandrel.
Supplemental Approvals, Statements
and Characteristics:
1. Sure -Weld TPO meets or exceeds the requirements of ASTM D6878
Standard Specification for Thermoplastic Polyolefin-Based Sheet
Roofing.
2. Radiative Properties for ENERGY STAR, Cool Roof Rating Council
(CRRC) and LEED.
3. Sure -Weld TPO membranes conform to requirements of the US
E.P.A. Toxic Leachate Test (40 CFR part 136) performed by an
independent analytical laboratory.
4. Sure -Weld TPO was tested for dynamic puncture resistance per
ASTM D5635-04 using the most recently modified impact head. 45-mil
was watertight after an impact energy of 12.5 J (9.2 ft-Ibf) and
60-mil was watertight after 22.5 J (16.6 ft-Ibf). 80-mil EXTRA was
watertight after an impact energy of 30.0 J (22.1 ft-Ibf).
5. NSF-P151 Certification for rainwater catchment system components.
- Plant 91/White Only
Pre -consumer Recycled Content
Post -consumer Recycled Content
Manufacturing Location
Solar Reflectance Index (SRI)
10%
0%
i
SYNTEC 8YSTEA4S
Radiative .•-
ENERGY STAR*, and
LEED
Test Method
White
Tan
Gray
TPO
Too
TPO
ENERGY STAR - Initial solar
Solar Spectrum
0.79
0.71
N/A
reflectance
Reflectometer
I ENERGY STAR -Initial solar
Solar Spectrum
0.70
0.64
N/A
f reflectance after 3 years
Reflectometer
,j
(uncleared)
CRRC- Initial solar
ASTM C1549
0.79
0.71
0.46
j reflectance
I CRRC- Solar reflectance
ASTM C1549
0.70
0.64
0.43
after 3 years
(uncleared)
I CRRC - Initial thermal
ASTM C1371
0.90
0.86
0.89
emittance
CRRC-Thermal emittance
ASTM Cl371
0.86
0.87
0.88
after 3 years
(uncleared)
i LEED- Thermal emittance
PASS
0.90
0.86
0.85
SRI -Initial
99
86
53
(Solar Reflectance Index)
I SRI -3 year aged.
85
77
48
(Solar Reflectance Index)
Radiative
•.
Reflectance
Emittance
SRI
Medium Bronze
0.28
0.86
29
Rock Brown
0.25
0.87
26
Slate Gray
0.38
0.87
42
i Terra Cotta
0.25
0.86
25
j Patina Green
0.25
0.88
25
Senatobla, MS Solar Reflectance Index (SRI) is calculated per ASTM E1980. The SRI Is a measure of the
roof's 'ability to reject solar heat as shown by a small temperature rise. It is defined so that
Tooele, UT a standard black (reflectance 0,05, emittance 0.90) Is 0 and a standard white (reflectance
Carlisle, PA 0,80, emittance 0.90) Is 100. Materials with the hlghestSRI values are the coolest choices
99 (white) 86 (tan) for roofing. Due to the way SRI Is defined, particularly hot materials can even take slightly
negative values and particularly cool materials can even exceed 100.
*ENERGY STAR recommends that using the Roof Savings Calculator (mc.oml.gov), which
factors In both heating and cooling costs, to determine whether a cool roof will be an energy
efficient choice for your geographic climate and building type.
a�
`p,SS/fjF. F� w�w
I U� O l�'-`-� ' APPROVED �a `i .
rAuuv.omecouarr @CtUC!&Ar6Vh
800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-245-7053 1 www.carlislesyritec.com
03.25.2002020 Carlisle. Carlisle, Sure -Weld, OctaGU&d XT, APEEL, Piranha Plates and HP-x are trademarks of Carlisle.
REPRINT CODE: 600515-"Sure-Weld TPO Reinforced Membrane Product Data Sheet" ENERGY STAR Is a registered trademark owned by the U.S. Government 'ENERGY STAR qualification is only "lid In the U.S.
LEED Is a mustered trademark of the U.S. Green Boldim Council.