Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553 Certification for Design Load Compliance Project Name: RE -ROOF Project Address: 7370 US HIGHWAY 1 Permit#: Occupancy Type: INSTRUCTIONS FOR USE: Construction Type: V • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications Involving the following: o New Residences (single or multi -family) o Residential Additio o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for Interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2017 6th Edition with 20_5upplements using ASCE 7-1( 2. Structure Designed as (check one): X Enclosed _ Partially Enclosed Open 3. Risk Category: _ 1 X II_ III_ IV Exposure Category: X B_ C_ D 4. Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width: 5 ft S. Mean Roof Height: 15 ft Roof Pitch: a.zs :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openin 16.0 16.0 Zone 1: Zane 2: 16.0 Zone 3: 27.6 27.6 Zone 4: Zone 5: Garage: N/A _27.6 -46 4 -69 8 _30.0 _37 0 N/A 7. Design Loads: Floor N/A PSF Roof/Dead: 7 PSF Roof/Live: 20 Balcony:_ N/A PSF Dock: N/A PSF Deck: N/A_ PST Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED S. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes —Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 250 PPSF Soil Test Reports Submitted? _Ye 1 certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: SLCCL Paul Welch P.E. Print Name Paul Welch Inc. 29945 / 5115 Cert # & Co. Cert Auth. 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL Company Name & Address