Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutDesign pressure calcsNewSouth
WINDOW SOLUTIONS
9596 Okeechobee Blvd. West Palm Beach, FL 33409 • 561-712-9000 • CRC1330822
Property Information
Building
Information
Owner: Alan coe
Wind Zone:
170 MPH.
Address: 379 Baysinger Ave
Exposure Category:
C
Fort Pierce, FL 34982
Minimum Building Dimension: 25 ft.
Mean Roof Height:
15 ft.
Risk Category:
11
Design
Pressure Calculations
Opening
Location
Device
Device Device
Max Positive
Max Negative
Number
Zone
Width (in)
L.L (in) Elevation (ft)
Pressure (psf)
Pressure (psf)
I
Int
48
48 7
36.6
-39.8
2
Int
48
48 7
36.6
-39.8
3
Int
64
48 7
35.9
-39.1
4
Int
32
35.50 7
37.8
-41.0
5
Int
32
35.50 7
37.8
41.0
6
Int
48
48 7
36.6
39.8
7
Int
32
35.50 7
37.8
-41.0
8
Int
32
36 7
37.8
-41.0
Prepared in accordance wish: ASCE 7-10, Chapter 30. Wind Loads - Compomnts and Cladding. 61h Edition (2017) Florida Building Code.
Page I of 1