Design pressure calcs
NewSouth WINDOW SOLUTIONS 9596 Okeechobee Blvd. West Palm Beach, FL 33409 • 561-712-9000 • CRC1330822 Property Information Building Information Owner: Alan coe Wind Zone: 170 MPH. Address: 379 Baysinger Ave Exposure Category: C Fort Pierce, FL 34982 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: 11 Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width (in) L.L (in) Elevation (ft) Pressure (psf) Pressure (psf) I Int 48 48 7 36.6 -39.8 2 Int 48 48 7 36.6 -39.8 3 Int 64 48 7 35.9 -39.1 4 Int 32 35.50 7 37.8 -41.0 5 Int 32 35.50 7 37.8 41.0 6 Int 48 48 7 36.6 39.8 7 Int 32 35.50 7 37.8 -41.0 8 Int 32 36 7 37.8 -41.0 Prepared in accordance wish: ASCE 7-10, Chapter 30. Wind Loads - Compomnts and Cladding. 61h Edition (2017) Florida Building Code. Page I of 1