Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
REVISION, Serkin Product Approval revision
OFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT # RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 6906 Cabana Lane, Fort Pierce, FL 34951 DETAILED DESCRIPTION OF PROJECT REVISIONS: We will no longer be using Tri- Built Materials product Tri-Built Sand 16048.1 as an underlayment. We will be using GAF t-enbuster High Traction Synthetic Roofing Underlayment 10626.1 CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CCC1326977 BUSINESS NAME: Modtek Roofing Inc. QUALIFIERS NAME: Luke McConnell ADDRESS: 1360 Old Dixie Hwy SW Ste 103 CITY: Vero Beach STATE: FL PHONE (DAYTIME): 7722138437 OWNER/BUILDER INFORMATION: NAME: Luke McConnell ADDRESS:1360 Old Dixie Hwy SW CITY: Vero Beach PHONE (DAYTIME: 7722036453 STATE: FL ARCHITECT/ENGINEER INFORMATION: NAME: NA ADDRESS: NA CITY: NA PHONE (DAYTIME): NA SLCCC: 9123109 Revised 06130117 STATE: NA ST. LUCIE CO CERT. #: ZIP: 32962 FAX: NA FAX: NA ZIP: 32962 ZIP: NA FL # -- Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL10626-R17 Revision 2017 Approved GAF 1 Campus Drive Parisppany, NJ 07054 (800)766-3411 mstieh@gaf.com Robert Nieminen Ireith@nemoetc.com William Broussard 1 Campus Drive Parsippany, N) 07054 (800) 766-3411 TechnicaIQuestionsGAF@gaf.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/16/2022 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL10626 R17 COI 2019 01 COI NIEMINEN pdf Standard year ASTM D1970 2015 ASTM D226 (physicals) 2009 ASTM D4533 (tear) 2015 ASTM D6164 2011 ASTM D6757 2016 FM 4474 2011 FRSA/TRI April 2012 (04-12) 2012 Equivalence of Product Standards Certified By https://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5V°/a2boQY9nVE2RUHVOuwgULxCexQ3n%2f%2f62rZgZHg°/a3d%3d 1/2 7/17/2020 Sections from the Code Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Of Method 1 Option D 12/16/2019 12/16/2019 12/19/2019 02/11/2020 06/08/2020 FL # Model, Number or Name ` Description 10626.1 GAF Roof Underlayments Roofing Underlayments for use in sloped roof systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL10626 R17 II 2019 12 FINAL ER GAF UNDERLAYMENTS FL10626- Approved for use outside HVHZ: Yes R17.pdf Impact Resistant: N/A Verified By: Robert Nlemien 59166 Design Pressure: +N/A/-442.5 i Created by Independent Third Party: Yes Other: 1.) The design pressure noted in this I Evaluation Reports application relates to one particular underlayment FL10626 R17 AE 2019 12 FINAL ER GAF UNDERLAYMENTS FL10626- system. Refer to ER Section 5.6.4 for details. 2.) R17 pdf Refer to ER Section 5 for other Limits of Use. Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. CQpyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund. Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, FS., please click here . Product Approval Accepts: StCiI 11 kl^.t` GICS, https://www.floridabuilding.orglprlpr app_dg.aspx?param=wGEVXQwtDgtBNbEY5V%2boQY9nVE2RUHVOuwgULxCexQ3n%2f%2f62rZgZHg%3d%3d 212 C MEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY :EVALUATION.O. GAF Evaluation Report 01506.04.08-1117 1Campus Drive FL10626-1117 Parsippany, NJ 07054 Date of Issuance: 04/25/2008 (800) 766-3411 Revision 17: 12/13/2019 SCOPE: This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61 Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 11. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 V. The facsimile seal appearing was authorized by Robert �.; S>' —' "g-•'` Nieminen, P.E. on 12/13/2019. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEW I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEW ETC, LLC NNEMO i etc. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1507.1.1, R905.1.1 Exception Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1.1, R905.1.1 Exception Tear Strength ASTM D4533 2015 1507.2.3 / 1507.1.1 Physical Properties ASTM D6757 2016 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3, R905.3.3 Physical properties FRSA/TRI April 2012 (04-12) 2012 1507.11.2 Physical Properties ASTM D6164 2011 3. REFERENCES: Entity Examination Reference Date ERD (TST 6049) Physical Properties R3360.02.07-2-R1 03/13/2007 ERD (TST 6049) Physical Properties G12110.12.08 12/02/2008 ERD (TST 6049) FRSA/TRI April 2012 (Slippage) G34150.08.11 11/14/2011 ERD (TST 6049) ASTM D6164 G40630.01.14-2B 01/07/2014 ERD (TST 6049) ASTM D6164 G46160.09.14-3A 09/09/2014 ERD (TST 6049) ASTM D1970 GAF-SC13285.03.17-3 03/01/2017 ERD (TST 6049) ASTM D1970 GAF-SC13285.03.17-4 03/01/2017 PRI (TST 5878) Physical properties BRY-003-02-01 03/19/2002 PRI (TST 5878) ASTM D1970 GAF-026-02-01 03/26/2002 PRI (TST 5878) ASTM D1970 GAF-027-02-01 03/26/2002 PRI (TST 5878) Physical properties GAF-042-02-01 06/03/2005 PRI (TST 5878) Physical properties GAF-224-02-01 07/27/2009 PRI (TST 5878) ASTM D1970 GAF-238-02-01 03/03/2010 PRI (TST 5878) ASTM D1970 GAF-275-02-01 11/11/2010 PRI (TST 5878) Physical properties GAF-349-02-01 07/03/2012 PRI (TST 5878) Wind Uplift GAF-434-02-01 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-03 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-04 09/16/2013 PRI (TST 5878) FBC 1507.1.1 (Exception) GAF-818-02-01 12/05/2017 PRI (TST 5878) FBC 1507.1.1 (Exception) GAF-826-02-01 06/04/2018 PRI (TST 5878) FBC 1507.1.1 (Exception) GAF-847-02-01 06/04/2018 PRI (TST 5878) FBC 1507.1.1 (Exception) GAF-914-02-01 04/10/2019 PRI (TST 5878) FBC 1507.1.1 (Exception) 376TOO12 07/15/2019 PRI (TST 5878) FBC 1507.1.1 (Exception) 376TOO18 x 2 07/31/2019 PRI (TST 5878) ASTM D1970 376T0032 10/22/2019 UL (TST 1740) Physical properties 02NK22569 06/04/2002 UL (TST 1740) ASTM D6757 1ONK11990 OS/18/2011 Miami -Dade (CER 1592) HVHZ compliance 16-1216.02 02/02/2017 Miami -Dade (CER 1592) HVHZ compliance 18-0119.15 02/22/2018 ICC-ES (EVL2396) IBC/IRC compliance ESR-2053 07/01/2017 [CC -ES (EVL2396) IBC/IRC compliance ESR-2808 07/01/2017 ICC-ES (EVL2396) IBC/IRC compliance ESR-1322 01/01/2018 ICC-ES (EVL2396) IBC/IRC compliance ESR-3286 02/01/2018 UL, LLC (QUA 9625) Quality Control Service Confirmation 12/17/2018 MEMO ETC, LLC Evaluation Report 01506.04.08-R17 Certificate of Authorization#32455 WHEDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R17 GAF Roof Underlayments; (800) 766-3411 Revision 17: 12/13/2019 Page 2 of 11 4. PRODUCT DESCRIPTION: 4.1 4.2 4.3 4.4 W. 5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 NMEMO I etc. Product Specification Plant(s) Description LibertyT SBS Self -Adhering ASTM D1970 Mt. Vernon, IN smooth -surfaced, fiberglass -reinforced, self- Base/Ply Sheet adhering SBS modified bitumen roof underlayment StormGuard® Film Surfaced ASTM D1970 Mt. Vernon, IN film -surfaced, fiberglass -reinforced, self - Leak Barrier Savannah, GA adhering SBS modified bitumen roof underlayment; also used as a secondary water barrier to seal roof decks WeatherWatch® Mineral ASTM D1970 Mt. Vernon, IN mineral -surfaced, fiberglass -reinforced, self - Surfaced Leak Barrier Savannah, GA adhering SBS modified bitumen roof Arkadelphia, AR underlayment; also used as a secondary water barrier to seal roof decks Deck -Armor'" Premium FBC 1507.1.1 & North Bay, ON non -woven, spun -bonded polypropylene Breathable Roof Deck R905.1.1 Dadra, India laminated polyethylene scrim sheet roof Protection (Exception) underlayment FeltBuster® High -Traction FBC 1507.1.1 & Richmond, VA non -asphaltic, polypropylene roofing Synthetic Roofing Felt R905.1.1 underlayment (Exception) Shingle -Mate® Roof Deck FBC 1507.1.1 & Pryor, OK fiberglass reinforced, asphaltic roof Protection R905.1.1 underlayment (Exception) StormSafe' Anchor Sheet FBC 1507.1.1 & North Bay, ON polypropylene woven fabric which serves as R905.1.1 an anchor sheet in two-ply roof (Exception) underlayment systems Tiger Paw" Roof Deck FBC 1507.1.1 & Dadra, India non -woven, polypropylene reinforced, Protection R905.1.1 North Bay, ON polymer coated roof underlayment (Exception) Parzai, India Umerkui Kilvani, India RoofPro— SBS-Modified All- AC165 Fontana, CA fiberglass -reinforced, SBS modified bitumen Purpose Underlayment roof underlayment VersaShield® Fire -Resistant ASTM D6757 Conover, NC non -asphaltic, fiberglass -based roof Roof Deck Protection (physicals) underlayment and/or fire barrier Ruberoid® Mop Granule ASTM D6164 Savannah, GA granule -surfaced, polyester -reinforced, asphalt -applied SBS modified bitumen roof underlayment Ruberoid® Mop Granule FR ASTM D6164 Savannah, GA granule -surfaced, polyester -reinforced, asphalt -applied SBS modified bitumen roof underlayment NENiO ETC, LLC Evaluation Report 01506.04.08-Ri7 Certificate o}Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R17 GAF Roof Underlayments; (800) 766-3411 Revision 17: 12/13/2019 Page 3 of 11 S. LIMITATIONS. ONEMOletc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request maybe made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: R! TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail -On Tile Foam -On Metal Wood Shakes & Slate or Simulated Tile Shingles. Slate Liberty—SBS Self -Adhering Base/Ply Sheet yes No No No No No StormGuard® Film Surfaced Leak Barrier Yes No No Yes No No WeatherWatch® Mineral Surfaced Leak Barrier Yes No No No No No Deck -Armor'"' Premium Breathable Yes No No Contact Contact Contact Roof Deck Protection GAF GAF GAF FeltBuster® High -Traction Synthetic Roofing Felt Yes No No No No No Shingle -Mate® Roof Deck Protection Yes No No No No No Tiger Paw'" Roof Deck Protection Yes No No Contact Contact Contact GAF GAF GAF RoofPro'"" SBS-Modified All -Purpose Underlayment Yes No No No Yes Yes VersaShield® Fire -Resistant Roof Deck Protection Yes No No No No No Ruberoid® Mop Granule Yes Yes Yes No Yes Yes See 5.5.1 Ruberoid® Mop Granule FR Yes Yes Yes No Yes Yes See 5.5.1 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS" Adhesive Florida Product Approval Underlayments DuPont TileBond " FL22525 Ruberoid® Mop Granule; Ruberoid® Mop Granule FR 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance NEMO ETC, LLC Evaluation Report 01506.04.08-1117 Certificate ofAuthorizotion#324SS 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-I117 GAF Roof Underlayments; (800) 766-3411 Revision 17: 12/13/2019 Page 4 of 11 5.6 Allowable Substrates: ME TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Primer Substrates LibertyT"" SBS Self -Adhering Base/Ply Sheet self -adhering (Optional) ASTM D41 plywood StormGuard® Film Surfaced Leak Barrier Weather Watch® Mineral Surfaced Leak Barrier Liberty'" SBS Self -Adhering Base/Ply Sheet self -adhering None ASTM D226 felt StormGuard® Film Surfaced Leak Barrier Weather Watch® Mineral Surfaced Leak Barrier Liberty'"" SBS Self -Adhering Base/Ply Sheet self -adhering ASTM D41 metal (flashing metal, valley metal, etc.) StormGuard® Film Surfaced Leak Barrier Weather Watch® Mineral Surfaced Leak Barrier Ruberoid® Mop Granule hot asphalt ASTM D41 structural concrete Ruberoid® Mop Granule FR Ruberoid® Mop Granule hot asphalt None GAFGLAS® #80 UltimaT"' Base Sheet or Ruberoid® 20 Smooth Ruberoid® Mop Granule FR 5.6.1 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on or mortar -set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure = -45 Dsf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 UltimaTm Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch D.C. at the min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. #2 Maximum Design Pressure = -75 Dsf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 UltimaT"" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch D.C. at the min. 4-inch wide side laps and 8-inch D.C. at three (3), equally spaced, staggered center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. NEMO ETC, LLC Evaluation Report 01506.04.08-R17 Certificate of Authorization #31455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL 10626-R17 GAF Roof Underlayments; (800) 766-3411 Revision 17: 12/13/2019 Page 5 of 11 #3 Maximum Design Pressure = -97.5 psf. ONEMOletc. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 UltimaT"" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c. at the min. 2-inch wide side laps and 4-inch o.c. at four (4), equally spaced center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FIR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. #4 _Maximum Design Pressure = -442 5 psf. Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction Base Sheet: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FIR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. 5.6.1.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Maximum Exposure (days) Deck -Armor'" Premium Breathable Roof Deck Protection, FeltBusterO High -Traction Synthetic Roofing Felt, Shingle -Mate® Roof Deck Protection, StormSafe— Anchor Sheet, Tiger Paw— Roof Deck Protection, RoofProT" SBS-Modified All -Purpose Underlayment, Liberty— SBS Self -Adhering Base/Ply Sheet, 30 StormGuard® Film Surfaced Leak Barrier and WeatherWatcho Mineral Surfaced Leak Barrier VersaShield® Fire -Resistant Roof Deck Protection, Ruberoid® Mop Granule and Ruberoid® Mop Granule FR 180 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Ruberoid® Mop Granule Flat Max. 10-tile stack 4:12 Flat Max. 6-tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack 5:12 Ruberoid® Mop Granule FIR Flat or Lugged Max. 6-tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack J. 4:12 NEMO ETC, LLC Evaluation Report 01506.04.08-R17 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R17 GAF Roof Underlayments; (800) 766-3411 Revision 17. 12/13/2019 Page 6 of 11 NNE etc. 6. INSTALLATION: 6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application and prime the substrate (if applicable). 6.3 Install self -adhering underlayments when ambient temperatures are minimum 45°F and rising. 6.4 All metal surfaces shall be primed with Matrixm 307 Premium Asphalt Primer or alternate GAF accepted ASTM D41 primer prior to application of self -adhering membranes. 6.5 Deck -Armor'"" Premium Breathable Roof Deck Protection: 6.5.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width for double -layer applications. 6.5.2 Fasteners: Minimum fasteners shall be 1-inch diameter plastic -capped corrosion resistant nails or 1-inch diameter plastic - capped, corrosion resistant staples, unless restricted by Code. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails shall be required where the ultimate design wind speed, Vauia equals or exceeds 150 mph." 6.5.3 Slopes of 4:12 or greater: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch o.c. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.5.4 Slopes of 2:12 to less than 4:12: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 28.5-inches (for 54-inch wide rolls) or minimum 25.5-inches (for 48-inch wide rolls). End (vertical) laps shall be offset from course to course not less than 6 feet. Begin by fastening a full -width along the eaves or install full -width leak barrier. Place a full -width sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 28.5-inch side laps (for 54-inch wide rolls) or minimum 25.5-inch side laps (for 48-inch wide rolls), resulting in a double -layer application. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch o.c. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.5.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty— SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier or WeatherWatch" Mineral Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. NEMO ETC, LLc Evaluation Report 01506.04.08-R37 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626_R17 GAF Roof Underlayments; (800) 766-3411 Revision 17: 12/13/2019 Page 7 of 11 ONEMOjetc. 6.6 FeltBuster®Hlgh-Traction Synthetic Roofing Felt or Tiger Pawl Roof Deck Protection: 6.6.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width for double -layer applications. 6.6.2 Fasteners: Minimum fasteners shall be 1-inch diameter plastic -capped corrosion resistant nails or 1-inch diameter plastic - capped, corrosion resistant staples, unless restricted by Code. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "..except metal cap nails shall be required where the ultimate design wind speed, Vault, equals or exceeds 150 mph." 6.6.3 Slopes of 4:12 or greater: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch o.c. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.6.4 Slopes of 2:12 to less than 4:12: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 25.5-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Begin by fastening a full -width along the eaves or install full -width leak barrier. Place a full -width sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 25.5-inch side laps, resulting in a double -layer application. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch o.c. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.6.5 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty" SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. 6.7 StormSafeT"' Anchor Sheet: 6.7.1 StormSafel Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems. 6.7.2 Fasteners: Minimum fasteners shall be 1-inch diameter plastic- or steel -capped corrosion resistant nails; corrosion -resistant nails & 1-5/8-inch tin -caps; or Drill-Tec screws and plates, unless restricted by Code_ Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "..except metal cap nails shall be required where the ultimate design wind speed, Vauib equals or exceeds 150 mph." 6.7.3 Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch o.c. Fasten in the field of the roll 12-inch o.c. in two, equally spaced, staggered center rows. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. One the same day, install LibertyT" SBS Self -Adhering Base/Ply; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier over the StormSafeT Anchor Sheet. MEMO ETC, LLC Evaluation Report 01506.04.08-R17 Certificate ofAutharization #32455 6T" EDITION (2017) FBC NON-HVH2 EVALUATION FL10626-R17 GAF Roof Underlayments; (800) 766-3411 Revision 17: 12/13/2019 Page 8 of 11 *NEMO I etc. 6.8 RoofProTM' SBS-Modified All -Purpose Underlayment and Shingle -Mate® Roof Deck Protection: 6.8.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed. 6.8.2 Fasteners: As required in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed. No hammer tacks or staples are permitted. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: ':..except metal cap nails shall be required where the ultimate design wind speed, V,,,h, equals or exceeds 150 mph." 6.8.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty'" SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. 6.9 VersaShieldg Fire -Resistant Roof Deck Protection: 6.9.1 Shall be installed in compliance with the codified requirements for ASTM D6757 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.9.2 Fasteners: Minimum fasteners shall be 1-inch diameter plastic -capped or metal -capped corrosion resistant nails or 1-inch diameter plastic -capped, corrosion resistant staples, unless restricted by Code. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails shall be required where the ultimate design wind speed, Va it, equals or exceeds 150 mph." 6.9.3 Slopes of 4:12 or greater: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch D.C. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.9.4 Slopes of 2:12 to less than 4:12: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 22-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Begin by fastening a half -width starter strip along the eaves or install full -width leak barrier. Place a full -width sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 22-inch side laps, resulting in a double -layer application. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch D.C. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.9.5 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty'" SBS Self -Adhering Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. NEMO ETC, LLC Evaluation Report 01506.04.08-1117 Certificate of Authorization #32455 6`" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R17 GAF Roof Underlayments; (800) 766-3411 Revision 17: 12/13/2019 Page 9 of 11 NNEMO I etc. 6.10 Liberty'"" SBS Self -Adhering Base/Ply Sheet: 6.10.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1S07.1.1 for the type of prepared roof covering to be installed. 6.10.2 The minimum and maximum roof slopes are %::12 and 6:12, respectively. Back -nailing is required when slope is 1:12 or greater. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. encapsulated within min. 3-inch side laps. 6.10.3 Non -Tile Applications: Shall be fully self -adhered to the substrates noted in Section 5.6. For direct -bond to deck applications plywood shall be primed with Matrix"'" 307 Premium Asphalt Primer or alternate GAF accepted ASTM D41 primer at % to %gallon per square. Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Roll out sheet and allow to 'relax' for min. 30 minutes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix'" 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-inch apart. Use a weighted lawn or linoleum roller to ensure complete adhesion to the substrate. Use a hand roller to firmly bond side and end laps. 6.11 StormGuard® Film Surfaced Leak Barrier: 6.11.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.11.2 Back -nailing is required. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. encapsulated within min. 3-inch side laps. 6.11.3 Non -Tile Applications: Shall be fully self -adhered to the substrates noted in Section 5.6. Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of Matrix'"" 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-inch apart. Use a hand roller to firmly bond side and end laps. 6.12 WeatherWatchO Mineral Surfaced Leak Barrier: 6.12.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.12.2 WeatherWatch® Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4- inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6.12.3 Back -nailing is required. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. encapsulated within min. 4-inch side laps. NEW ETC, LLC Evaluation Report 01506.04.08-R17 Certificate of Authorization#31455 6Ta EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R17 GAF Roof Underlayments; (800) 766-3411 Revision 17: 12/13/2019 Page 10 of 11 6.12.4 Non -Tile Applications: { vt i1 NEMO I eti Shall be fully self -adhered to the substrates noted in Section 5.6. Prior to removal of release film, align sheets properly starting at the low -point of the roof leave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12" D.C. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of MatrixTm 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-feet apart. Use a hand roller to firmly bond side and end laps. 6.13 Ruberoid Mop Granule; Ruberoid® Mop Granule FIR: 6.13.1 Ruberoid® Mop Granule or Ruberoid® Mop Granule FIR shall be installed in compliance with current GAF published installation requirements. 6.13.2 For use in tile applications, Ruberoid® Mop Granule or Ruberoid® Mop Granule FIR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems, 6.13.3 Fully adhere in ASTM D312, Type IV hot -asphalt to the substrates noted in Section 5.6. Side laps shall be minimum 4-inch and end -laps minimum 6-inch wide, and offset end -laps minimum 3-feet from course to course. Side and end -laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8- inch beyond the lap edge. 6.13.4 Consult GAF instructions regarding back -nailing requirements. 6.14 Tile Staging (Ruberoid® Mop Granule; Ruberoid® Mop Granule FIR): 6.14.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 4 herein, and GAF published requirements for the staging. 6.14.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the manufacturer or the named CA entity for plants covered under Rule 61G20-3 CtA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - NEIVIO ETC, LLC Evaluation Report 01506.04.08-R17 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-1117 GAF Roof Underlayments; (800) 766-3411 Revision 17: 12/13/2019 Page 11 of 11