Loading...
HomeMy WebLinkAboutMobile Home Inspection Report1 St Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce, FL 34982 Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone II certified. Owner::yya Y A R L YES Date: a. S aoao (Print or type) _I I MfffipwNbl Addres Year/ Width;_H Length '5!P Single C = In Compliance N = Not in Compliance LOT 1411 C AAtfP IrLA AW3o3 HUD Plate # %5LA oZ R30Y Double Wind Zone Fire Safety / Electrical 1. Smoke Detector: Installed Missing —C— 2. Electrical System Checked: Exposed Wiring _Other_ _ 3. Distribution Panel: Missing Loose_ Main Missing Breaker Missing_ Unplugged Opening Other _C 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire_ GFCI receptacles not where required_ Ce 5. Electrical Ground: Chassis Main Panel Gas Pipe Revised 3/9/05 Page 1 of 3 I Construction C_ 1. Exit Doors Operable: Front Back Other 2. Exit Door Locks: Missing Inoperable 3. Egress windows: Missing Inoperable _4. Windows: Broken Glass Inoperable 5. Screens: Missing Damaged_ 6. Floor System: Joist Decking Area Damaged SOFT F4R W MtLbYi'kY 7. Interior Paneling: Missing _ Loose _ Damaged_ �_ 8. Rodent Proofing: Bottom Board _ Pipe openings _ Other _L 9. Leaks Apparent: Ceiling _ Doors _ Floor _ Roof 10. Vertical tie -down straps: Missing _ Short _ Damaged_ 11. Structural modifications since manufactured: YES_ NO-Z 12. Walls: Structurally Unsound _ Loose _ Weather tight Plumbing C 1. Trap: Missing Not connected Other _C 2. Plumbing fixtures: Missing _ Not installed _ Not Vented 3. Relief Valve: Missing Inoperable Other _ 4. Drain Waste and Venting Piping: Missing Not supported_ Clean outs _ Use of fittings _ Not capped_ Heating and Air Conditioning 1. Heating Appliances: Missing Not Connected _r— 2. Deleted Heating/AC system: Not installed Other 3. Thermostat: Missing Inoperable 4. Air registers: Missing Inoperable 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 (RERVRRecF) -- 6. Gas furnace Water heater vent: Missing �7. Return Air: To Furnace To A/C 8. Range: Vent Hood Loose From roams - _i 9. Gas Valve: Accessible Installed improperly 10. Gas lines: Not capped Not supported Kinked Not bonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO--V—/— 2. Will a remodeling permit be required? YES NO_V/— The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX Date inspected: a ;' 26' Inspected By: V J . �,__ sign lure requrred� Phone Number: l,�(]'//aJ 1 THEIR SEAL. License# 3`�3g8 Page 3 of 3 En&sW STEVEN G. WOOD, P.E. FL LICENSE 34398 Sg0 SULTAN DR peaT ST LUCIE, FL