Loading...
HomeMy WebLinkAboutProduct approvals, 16851.53/31/2020 Florida Building Code Online BCIS Home Log In User Registralkm db'pr Y�ProductcUser uses: Publla User frTG� I �i• ._ .=6ir Hot Tgft Submit Sumbarye Sets & Facts Publiratlom Cantnct Us BCIS Site Map Unks Search pruJUR Approval Menu > Prod,a or Agol cat on Searcn > 6pallcabon Ust > Appllc rdan Gatall FL N FL16851-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer NewSouth Window Solutions Address/Phone/Email 10741 Crossroads Commerce Blvd. tampa, FL 33610 (813) 626-6000 danochstein@newsouthwindow.com Authorized Signature Vivian Wright rickw@mbidgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2020 Validated By Ryan 1. King, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL16851 R7 COI (d) Certificate of Ind I?en0ence.l7_df YAM AAMA/WDMA/CSA101/I.S.2/A440 2011 AAMA/WDMA/CSA101/I.S.2/A440 2008 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201, 202, 203 1994 Sections from the Code https://www.floridabuilding.org/pr/pr_app_dU.aspx?param-vGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGe9cEYNv7g2QiOQ%3d%3d 1/5 3/31/2020 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products Go to Page S Method 1 Option D O6/07/2018 O6/26/2018 06/27/2018 08/15/2018 03/27/2020 00 Page l/200 FL ! Modd, Number or Nome Description 16851.1 a. 9400 Single Hung Window Extruded Vinyl "Non -Impact' Single Hung Tit Window New Construction with Nail Fin (O/X - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R7 11 (b) Inst 16851.1.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.1 for Design Pressure Ratings, any FL36851 R7 AE (b) Eval 16851.1.12d( additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. 16851.2 b. 9400 Single Hung Window Extruded Vinyl *Non -Impact" Single Hung Tit Window with Flange (O/X - configuration) LlmRs of Use Installation Instructions Approved for use In HVHZ.• No FL16851 R7 II fbJ [nst 16851.2.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.2 for Design Pressure Ratings, any FL16851 R7 AE its) Eval 16851.2.ILdf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16851.3 c. 9450 Single Hung Window Extruded Vinyl 'Impact" Single Hung Tit Window New Construction with Nall Fin (O/X - configuration) Limits of Use Installation InsWctions Approved for use in HVHZ: No FL16851 R7 II fb) Inst h251.3.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Design Pressure: N/A Created by Independent Third Party: Yes Evaluation Reports Other: See INST 16851.3 for Design Pressure Ratings, any FL16851 R7 AE (b) Eval 16851.3 odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16851.4 d. 9450 Single Hung Window Extruded Vinyl "Impact" Single Hung Tit Window with Flange (O/X - configuration) Installation Instructions Limits of Use Approved for use In HVHZ: No FL16851 R7 II (b) Inst 16851 Ad& Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST I6851.4 for Design Pressure Ratings, any FL16851 27 AE (p)Fval 16851 4 odf additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. ruled Vinyl "Impact' Single Hung Tih Window New 36851.5 e. 9450 Single Hung Window Impact Rated - HVHZ nstruction with Nall Fin (O/X - configuration) Limits of Use Installation Instructions Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes FL16851 R7 II (� Inst 16851.S.odf Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.5 for Design Pressure Ratings, any FL16851 R7 AE (b) Eval 16851.5.gd( additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16851.E f. 9450 Single Hung Window Impact Rated - HVHZ Extruded Vinyl "Impact" Single Hung Tit Window with Flange (DIX - configuration) Limits of Uw Installation Instructions htp :th~.florldabuilding.orglpr/pr epp d8.aspx7parem-vGEVXQMDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGegcEYNv7g2QiOQ%3d%3d 2/5 3/312020 Florida Building Code Online Approved for use in HVHZ: Yes I L i6851 R7 II (Q) Inst 16851.6.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.6 for Design Pressure Ratings, any FL16851 R7 AE (Q) Eval 16851.6.gd_f additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. 16851.7 g. 4400 Single Hung Window Extruded Vinyl 'Non -Impact" Single Hung Window New Construction with Nail Fin (O/X - configuration) Llmita of Use Installation Instructions Approved for use In HVHZ: No FL16851 R7 II (1) Inst 16851.7.odf Approved for use outside HVHZ: Yes Verified By: Lyndon R Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.7 for Design Pressure Ratings, any FL16851 R7 AE (b) Eval 16851.7.ggf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16851.8 1 h. 4400 Single Hung Window Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 16851.8 for Design Pressure Ratings, any additional use limitations, installation Instructions and product particulars. Extruded Vinyl "Non -Impact" Single Hung Window with Flange (DIX - configuration) Installation Instructions FL16851 R7 II (d) Inst 16851.8.gdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16851 R7 AE (d) Eval 16851.8.gd( Created by Independent Third Party: Yes 15851.9 I. 4450 Single Hung Window I with Ned Fin (O/X Vinyl pect" Single H) Hung Window New Construction gurati units of use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 16851.9 for Design Pressure Ratings, any additional use limitations, Installation instructions and product particulars. 16651.10 j. 44SO Single Hung Window Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 16851.10 for Design Pressure Ratings, any additional use limitations, Installation Instructions and product particulars. Installation Instructions FL16851 R7 II (d) Inst 16851.9.odf Verified By: Lyndon F. Schmidt, RE. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16851 R7 AE (d) Eval 16851.9.gdf Created by Independent Third Party: Yes Extruded Vinyl "Impact" Single Hung Window with Flange (O/X - configuration) Installation Instructions FL16851 R7 II (c) Inst 16851.10.ddf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16851 R7 AE (d) Eval 16851.10.odf Created by Independent Third Party: Yes 16651.11 It. 4450 Single Hung Window Impact Extruded Vinyl "Impact" Single Hung Window New Construction Rated - HVHZ I with Nail Fin (O/X - configuration) Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL16851 R7 II (Q) Inst Sfi851.11.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.11 far Design Pressure Ratings, any FL16851 R7 AE (Q) Eval 16851.SS.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16851.12 I. 4450 Single Hung Window Impact Rated - HVHZ Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 16851.12 for Design Pressure Ratings, any additional use limitations, Installation instructions and product particulars. Extruded Vinyl "Impact" Single Hung Window with Flange (O/X - configuration) Installation Instructions FL16851 R7 II (Q)[nst 16851.12.odf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16851 R7 AE fQ) Eval 16851.12.odf Created by Independent Third Party: Yes 16851.13 m. 4000 Twin Single Hung Window Extruded Vinyl "Non -Impact" Twin Integral Mulled Common iamb Single Hung Window New Construction with Nail Fin (O/X I O/X - configuration) https:IAw.floridabuilding.org/pr/pr_app_dfl.aspx?param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGeScEYNv7g2QiOQ%3d%3d 3/5 3/31/2020 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R7 II (b) Ins[ 16851.13.0df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.13 for Design Pressure Ratings, any FL16851 R7 AE (b) Eval 16851.13.pdf additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. 16851.14 n. 4000 Twin Single Hung Window Extruded Vinyl 'Non -Impact" Twin Integral Mulled Common Jamb Single Hung Window with Flange (O/X I O/X - configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No Approved for use outside HVHZ: Yes FL36851 R7 II (b) Ins[ 16861.14.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.14 for Design Pressure Ratings, any additional use limitations, Installation instructions and product FL36851 R7 AE (b) Eval 16851.14.otlf Created by Independent Third Party: Yes particulars. 16851.15 0. 4000 Triple Single Hung Window Extruded Vinyl "Non -Impact" Triple Integral Mulled Common Jamb Single Hung Window New Construction with Nail Fin (O/X I O/X I DIX - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16851 R7 1[ (b) Inst 16851.15.= Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.15 for Design Pressure Ratings, any FL16851 R7 AE (b) Eval 16851.SS.odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 16851.16 p. 4600 Twin Mulled Single Hung / Picture Window Extruded Vinyl 'Non -Impact" Twin Integral Mulled Common Jamb Single Hung / Picture Window New Construction with Nail Fin (O/X 10 - configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL16851 R7 II (b) [ns[ 16851 16.odf Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.16 for Design Pressure Ratings, any FL16851 R7 AE (W Eval 16861.16.gd( additional use limitations, installation Instructions and product particulars. Created by Independent Third Party: Yes 16851.17 q. 4600 TWIn Mulled Single Hung / Extruded Vinyl'Non-Impact' Twin Integral Mulled Common Picture Window Jamb Single Hung / Picture Window with Flange (O/X 10 - configuratlon) Limits of Use Installation Instructions Approved for use In HVHZ: No Approved for use outside HVHZ: Yes FL16851 R7 II (b) Inst 16851.17.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16851.17 for Design Pressure Ratings, any additional use limitations, installation Instructions and product FL16851 R7 AE (b) Eval 16851.17.pdf Created by Independent Third Party: Yes particulars. 16851.18 r. 4800 SH/SH/SH - Triple Single Hung Extruded Vinyl Integrally Mulled Triple Single Hung Windows with Flange; (O/X I O/X I O/X configuration) Installation Instructions Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes FL16851 R7 II (b)_Ins[ 16851 18.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Design Pressure: N/A Created by Independent Third Party: Yes Evaluation Reports Other: See INST 16851.18 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. FL16851 R7 AE (b) Evai 16851 18.pdf Created by Independent Third Party: Yes 16851.19 s. 4900 SH/Sri - Twin Single Hung Extruded Vinyl Integrally Mulled Twin Single Hung Windows with Flange; (O/X I O/X configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 16851.19 for Design Pressure Ratings, any additional use limitations, Installation Instructions and product particulars. FL16851 R7 II (a) Inst 16851.19.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16851 R7 AE (d) Eval 16851.19.pdf Created by Independent Third Party: Yes hftps://www.floridabuilding.org/pr/pr_app_d0.aspx9param=wGEVXQwtDgbnmTSTNdVPsacroUCDUOyarHoxOGegcEYNv7g2QiOQ%3d%3d 4/5 3/31/2020 Florida Building Code Online 16851.20 t. 4900 SH/SH/SH - Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows Hung with Flange; (O/X I O/X I O/X configuration) Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 16851.20 for Design Pressure Ratings, any additional use limitations, Installation instructions and product particulars. Installation Instructions FL16851 R7 II fQ) Inst 1fi851.20.odf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16851 R7 AE (Q) Eval 16851.20.otlf Created by Independent Third Party: Yes Go to Page 0 0 Page 1/ 2 0 0 Contact Us :: 3e01 Blair Stone Road Tallahassee FL 32399 Phone: 850487-1824 The state of Florida Is an AA/EEO employer. copyright 2007-2013 State of Florida, :: privacy Stemmen[ :: Accesslblllty Statement :: Refund Statement Under Florida law, email addresses arc pudic records. If you do not want your e-mall address released In response to a public -records request, do not send elechonic mall to this entity. Instead, contact Me office by phone or by traditional mall. if you have any questions, please contact 850.487.1395. *Pursuant to section 455.275(1), Florida Statutes, eaectihm October 1, 2012, Ilcereees licensed under Chapter 455, F.S. must provide Me Department with an email address If they have one. The emails provided may be used for official communication with Me licensee. However mall addresses are public record. If you do not wish te supply a personal address, please previde the Department with an email address which on tie made available to Me public. To determine 8 you are a licensee under Chapter 455, F.S., please dick hem. praduet Approval Arcapls: ®® ® El t Credit Card Safe https:llwww.floddabuilding.org/prlpr_app_dtl.aspx7param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGegcEYNv7g2QiOQ%3d°/3d 5/5 0 MG •eN Y0 3ded S31ON Mtl3N30 8 S:WSS311d S I Lele'ero'ua raN weyd N01S30 INCUVA313 7901d)d 31Y0 N n lol SeSCc ld 'oaNloA 'OfZ soB '0-d SS7 3EU t1UL 'W WS 01 3IYOd0 cl 9L 9 1 vi Y 'JN! 'SINv1lO5NW ONIOl109 ('f AWMN NO 1 d Mf O LIM '03 N19 Ol 31g LI 01 L ��``�Pt'1VN0 pryb 3'd z N p `2NLJ���pyjp:"a' la!wy>s .j uoou.h MOONIM 'JNlIH 370Ni5 Y :'e n•.°a..e Nu�naw �I0000ed 0 40Z el mom 6 KV cN ��rrr I'llitZi ` W C FF ZE z � C 6 z � g � o N i 5 fr i d 0 m a ° 4 8 N � b a a c n llIJ13H 3YNV}ld'%V9i.9L s 2 � c _mtlb � —Nt7fNV c.<wnv 6NvcTcaOrnAvrrol r<aor-rnrW!wrl -M6unN aBUK rca9rlAiMOMdY °wou aarou NINiM'wMiA sNNnvA uYwS wHwuyDVx Do ft88 -ON YO 348 SNOISIA38 SN01103S SSOSO LGL OOMIPA' �oN 'O'd h ltl1NOZ1lIOH >J IMJLLN3i1 in SBSff V 'oDMIDN •pC2 •oB 'O'd M_�/� In 4 'ONI 'Sl IIMN00 ONNIIIne �PuQfi �A18N355tl tl0 11Nd B49C1 'ON '3'd polwws '! De a MOON4N ONOH 370N15 d 4 A, wWuy quxuroep �1pnO0Md b � � � A • LIQZ ZI J040po `*•. BOICy DN �� yJ.d.N,ipt�; •j� Pd" ,ewa NAD Iwa 'NIw.Y/I-t 'NIW.Vlk-I O rc m z G N \\\ N N W N K O rc w x N H O N N Z P9 w N N U S t5 � N m III IIIIIIIIIIII i. Fg �� ox$ �NS z_ AB 31tl0 ON 53'I OB3 910Z '03 N1S O1 31y0dn Sl 9Z 9 t Mf OB3 LIOZ '03 N19 Ol 31y0d0 LI BO 01 Z [-Z'�'C'S'ISB9L'tiU(SpZI L599L'li\L6uixep �\EunN NSu15 LSH3L'1fVIP.VMOy 1MWy ¢pWN VLLN3NYWll3E S.v4puM VIM$ W N\IluaiOVY eo CM '9N VO 3dHd SNOI1B35 55O8� SNOISV\38 La1a'6N'Cla :'aN •ucgd 1VIN0ZI8OH 8 1Y31183A 31tl0 ON 9aCfC V 'ooM1oA •OfL •08 'O'd M'�/' S31 Jflf 4lOZ '03 H1S Ol 31VOd0 Sl 9Z 9 1 vi 'ONI ' W II 9NOO ONI IM-BU(]f IA18W S HO 19Vd Nf JB! LIOZ '03 N19 OL 31YOd0 L1 0, OL \vlwya5�j�uop3uRd� MOONIM 9NnH 31'JNIS ••IaalO>V •� ;4 w•aw quwuiuoa15n0Otld E S b LIOZ ZL L9g0AO U � U o m z i 0 h �u R �» a. x N O �i O! V 05 0 u og �wR 0C3 LL �� Z PI � 1NL e W y aV a 09 au o2 x„ E €Q of �x I-ES"'S'L5897 IA(LT0i) L589S-b\s6ulmep-J\6unH W6.5 LSnl IAII�V nnpml W-IJ- tl MNVMM �u!M Vino$MAN\slua!Dttl 969££ ld 'o IDA 'O£i =8 'O'd �Yb� 'ONI ' 1 IIMNOO ONIMIN9 \\\\\U111111III"''' 1PIwVx£YJ �000� ='Njt puv°m�9ruw t YfL�L{OZ/'Zl 19WG0 s a �II11111111 Li ONI80HONV 3MIA b N008 ;Al9N3SS 80 19vd SNOISIA321 •- 0i 2 y Y E2 u' '� 31V0 ON 53I O93 >10Z '03 H S O1 31VOdO Sl 9Z 9 I Af 093 LIOZ '03 H19 01 31V0d0 LI 90 OI MOONIM ON11H 319NIS- F � I o U❑Q I Z�+aw 17i0� U lO p O07 y ZZoo v I f�<5 1 <Z,V S I O F O I �yU2 ivy it m rc a � r 0 NAI) z !n ; L TT rlds tl.•-'.�'... •'�-� NU N m rdw OO 0".9 3 Wm� V m u xm z N O w O � FI'dw ly T mEff you 4 L . Pm =pa m m � �m8€�0 f ((ZUZJJ t m pQ�j ssggC uUtuft N ei [-0'6mG'S'IMT-IN1I061S99IIi\d U-1-J\6-nH.Aul5ism livmN d, wN,-PI-I-V NMAVM irw UM RMn -NkWu 10 tl CLOG '" Y0 3ded $N0 SI/\38 S1N3NOdW00 LB Le'eee'f LB :'ON Sueyd A� A9 31V0 ON self[ V 'oay�oA •OCZ -8 '0'd //U,&r 5: Oei it OZ '43 H1S Ol 31YOd0 St 9Z 9 t vi 4 N 'ONI ' t llOSNOO ONimine AleW35 NO laud Nf OHi L102 '43 H19 Ol 31VOd0 Lt 60 01 Z n 7 ;R WS 'ON .P.Al ,MOONIM `JNOH 310NIS yy pp YY uGu • 'mow •• •i :Ag 1Of1004d E d b 0 A uoz zl ,egom h � sroO o I�— T 1 ce a a 0 AZ 0 o N Y Tn Li 0 O I O o p Lzvi- .9zo—1 r AZ' I —vI 10 n N I 1 q f—.99'1 n] .BLi E EN m DLT .6I'Z m 1 ago ° b o � .z9oo v i I I S� •62 e 6ZZ� L-G'fiN0'G'iGPai-11\I/1MiGPat-tA5UIM -l\�PH B16UK iGPat tJ\P�Pb1EEV llllWN POUON VLLN3NVWb3d SMOOUIM YIIIO$MPNV1Yd, J�N e C➢ Elea 'oN YO 3de! SNOISIA38 SlItl1.30 ONI-40 ONtl ti a -a A le : - '0-d ,P� SlWd31tlW d0 1118 A9 31tl0 ON n BaeCC L 'eoypA 'OfL •ee 'O'd /1/1 531 JB! 9lOZ '03 N1S Ol 31Mdn SI 9Z 9 l Ni Y Ili 'ONI 's.lwn05N00 ONimins / A]aW355b a0 ltlbd Nf OB3 LIOZ '03 H19 Ot 31tlOd0 LI 90 01 Z J ;.�"jp1,•., iVw4ee Y'l �uNePu,j MOONIM ONlIH 310NIS ¢ ■ ¢s ■L 4 'As n•�.mJd .w.w•.w :1OW00ad 5 E b -*: *vo _ ; aBYEI BN �- .:>, 5 e u _ Z Z� € z z< `M < a <„ V` Q 0N so o � � 0O _ n � O � Z z )/1) O pK�12 w m W U 0 Z Oz aO_ m s' 12 O <U w�LL 3❑ Cz S K s 2� 32 o� O o UUZn cc u S9 03 �z3a W 3z a W SU 0 < cc �pOp � U 3 � U '6 U p �•,3"'•^'•,5252�3 UUUUUUUUa= 1' d' 52 K GC 52 d• C1OO 52 fG 52 K i � 52Cj��fj R' x i � V f =U= !�� x li Y � � UU � 3� OC OQ OL 3 c O � � o o �Uz�r� ZO UOE w O YY gt� �_F1 N Oi-�]—y W ZZ K Ill !Y• $ Z= � NLwL �S jqj "'ON 6J viz Oi 11 6 rY DY J Y J N � ^� �S Z rN aC d• Uyi W �� Zr. U' xyy L]tv� i`A JI� Y iliy �� USu U =�xoox�xda=== <N Z�IV �00��'L u2 pC�� W K W J im V m W LL (f 2'� Y E N l�l P h •O n m P ���� �� Py N lV N i-O'aMY'c'i<.OinJ\IIinrl iCeOi-l�\SaW/Mn -1\aYnN d16YK i[Wi-lJ\S IPbdEb INm1A IpUH tl\I NiNtlWMN 5/JUWIM YIM$ MPNUIY iII]�B Iz w R W Building Consultants, Inc. Comulling and Engineering Services for the Building Industry P.O. Box 230 Valdco. FL 33595 Phone 813.659,9197 C, Florida Board or Professional Engineers Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name NewSouth Window Solutions 9450 Single Hung Window Windows Single Hung 4901 Oak Fair Blvd Impact Rated -HVHZ Tampa, FL 33610 w/ Nailing Fin 813 626-6000 Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for NewSouth Window Solutions, based on Rule Chapter No. 61G20-3, Method 1 D of the State of Florida Product Approval, Dept. of Business 8 Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ', this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing FL-16851.5 require further engineering analysis by a licensed engineer or registered architect. 5. See drawing FL-16851.5 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by ATI C9937.03-401-18 TAS 201, 202, 203-94 Architectural Testing, Inc. Shawn G. Collins, P.E. 2. Miami Dade NOA Materials Testing 17-0712.05 Saflex• PVB Interlayer (Eastman Chemical Co.) 3. Drawing No. Prepared by Signed 8. Sealed by No. FL-16851.5 RW Building Consultants, Inc. (CA#9813) Lyndon F. Schmidt, P.E. 4. Calculations Prepared by Signed 8 Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) Lyndon F. Schmidt, P.E. ASTM E1300 Glass Load Lyndon F. Schmidt, P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management 111ettriffr f ng t NewSouth ndow Solutions is products withinla quality assurance lrogram that complies with manufacturing `��. ............. oo�, 17020 and Guide 53. :� ,•��GEh�S`�,T ���, No 43409 *, ,sty 9 STATE O�. c�OfilpP:��,�.. 'P6�Sr0A„t� t%%,Lyndon F.Schmidt. P.E. FL PE No. 43409 1a1v2017 Sheet 1 of 1