Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY- EFFICIENCY CODE FORBUILDINGCONSTRUCTION_ Florida Departmenf of Business and Professional Regulation -Residential Performance 'Method Project Name: WYNNE THE MANOR IMPACT Builder Name: WYNNE BUILDING CORP.. . Street: THE MANOR 71 Sq ��V.y� Permit Office: ST. LUCIE COUNTY 'City, Stale, Zip:, FT. PIERCE, FL, Permit Number: , Owner: WYNNE BUILDING CORP. �� Jurisdiction: -Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) C New construction or existing. .. New (From Plans) 9. Wall Types (1654.2 sgft.), Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ird Insul, Exterior R=4.1 1374.20 ft2 • b. Frame -Wood, Adjacent .. R=11.0 280.00 ft2 3. Number of units, if multiple family 1 S c. N/A R= - ft2 4. Number of Bedrooms 2 d• N/A '(1754.0 R= ft2 ' 10. Ceiling Types sgft.) Insulation- . Area. 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1724.00 ft' 6. Conditioned floor area above grade (ft2) 1724 b. Knee Wall (Vented) -R=19.0 30.00 ft2_ c. NIA R= ft2 Conditioned floor area below grade (ft2) 0 - 11. Ducts R ft2 7. Wi'ndows(153A sgft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 150 a. U-Factor. Sill, U=1.04 113.35 ft2 SHGC: SHGC=0.29 b. U-Factor: sgl, U=1.11 40.00 ft2 12. Cooling systems kBlu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A . _ ft2 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor. N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50� SHGC: Area Weighted Average Overhang Depth: 3.010 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems _ a. Electric Cap:.50 gallons. 8. Floor Types (1723.5 sqft.) Insulation. Area - EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1723.50 ft2 b. Conservation features - b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.089 Total Proposed Modified Loads: 53.45 PASS Total Baseline Loads: 54.12 I hereby certify that the plans and specifications covered by Review of the plans and o�SS STAB this calculation are in compliance with the Florida Energy specifications covered.by this , 1 OA Code. calculation indicates compliance 1. with the Florida Energy Code. rnnr Qrw O PREPARED BY: Before construction is completed DATE: 1-9-20 this budding will be inspected for compliance with Section 553.908, y A hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Code. - WE t&� OWNER/AGE BUILDING OFFICIAL:, . DATE: _- �"� DATE: � - Compliance requires certification by the air'handlerunit manufacturer that the air handler enclosure"qualifies as certified factorysealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2): REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY ' 1/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6thFilitlog(2pd Compliant Software - Page 1 of 6 PROJECT Title: - WYNNE THE MANOR IMPA" Bedrooms: 2 Address Type: Street Address Building Typ'e:. User Conditioned Area: 1724 Lot#. ` . Owner Name: WYNNE BUILDING CORP. Total Stories: - 1 Block/Subdivision: " #of Units: 1 Worst Case: Yes PlalBook: " Builder Name: WYNNE BUILDING CORP. Rotate Angle: 270 Street: THE MANOR 71 Permit Office: ST. LUCIE COUNTY Cross Ventilation: No ' County: " St. Lucie . Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE , " Family Type: Single-family FL, New/Existing: New (From Plans) Comment:. CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location - TMY Site 97.5 % 2:5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area 'Volume 1 Entire House 1724 •14774.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 GREAT ROOM 546 5350.8 No 0 1 Yes Yes Yes 2 MASTER BEDROO 354 2832 No 2 1 1 Yes Yes Yes 3 WIC 77 616 No 0 1 No Yes Yes 4 CLST. 35 280 No 0 1 No Yes Yes 5 M BATH 54 432 No 0 1 Yes Yes. Yes 6 KITCHEN 180 1440 Yes 0 1 Yes Yes Yes 7 JUNIOR M. BED 198 . 1584 No 0 i 1 Yes Yes Yes 8 BATH so 400 No 0 1 No Yes Yes 9 POWDER 35 280. No 0: 1' .Yes Yes .Yes 10 NOOK 42 336 No 0 1 Yes ' Yes Yes 11 LAUNDRY 49 392 No 0. 1 Yes, Yes Yes 12 ENTRY 104 832 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio GREAT ROOM .47.f1 0 546:ft'.... _ 0 1 0 2 Slab -On -Grade Edge Insulatio MASTER BEDRO 46 It 0 354R' 0. 1 0 3 Slab -On -Grade Edge Insulatio WIC 1 ft 0 77 It' 0 1 0 4 Slab -On -Grade Edge Insulatio CLST. 1 fl 0 35 ft2 0 1 0 5 SIab-On-Grade Edge Insulatio M BATH 9 ft 0 54 ft' 0. 1 0 1/8/2020 4:31 PM EnergyGauge& USA 6.0.02.(Rev..1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMAKY 6KEGKLIS'1 KCPUKI FLOORS # Floor Type'Space Perimeter Perimeter R-Value Area JoistR-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio KITCHEN lift 0 180 ft2 __ 0 1 0 7.Slab-On-Grade Edge Insulatio JUNIOR M. BED 14 ft 0 198 ft' ____ 0 1 0 8 Slab -On -Grade Edge Insulatio BATH 1ft 0 50 1112 __ 0 9 0 . 9 Slab -On -Grade Edge Insulatio POWDER 5 ft 0 35 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulatio NOOK 6 ft 0 42 112 ___- 0 1 0. 11SIab-On-Grade Edge Insulatio LAUNDRY 17 ft 0 49 ft2 -___ 0 1 0 Miab-On-Grade Edge Insulalio ENTRY 5.9 ft 0 103.5 ft- — 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 -Hip Metal 1817 ft2 0112 Light N 0.6 - No 0.9 No '0 18.4 ATTIC / V IRCC• # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Vented -300 1724 ft2 N N CEILING Ceiling Type Space R-Value Ins Type Area - Framing Frac Truss Type _ 1 Under Attic (Vented) GREAT ROOM 30 Blown 546.ft2 0.1 Wood 2 Under Attic (Vented) MASTER. BEDRO 30 Blown 354 112 0.1 Wood _ 3 Under.Attic (Vented) WIC 30 Blown 77ft2 0.1. Wood _ 4 Under Attic (Vented) CLST. 30 Blown 35 ft' 0.1. Wood 5. Under Attic (Vented) M BATH 30 Blown 54 ft2 0.1 Wood _ 6 Under Attic (Vented) KITCHEN 30 Blown 180 ft2 0.1 Wood _ 7 Under Attic (Vented) JUNIOR M. BED 30 Blown 198 ft2 0.1 Wood _ 8 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 . Wood 9 Under Attic (Vented) POWDER 30 Blown 35 ft2 0.1 Wood 10 Under Attic (Vented) NOOK 30 Blown 42 ft' 0.1 Wood _ 11 Under Attic(Vented) LAUNDRY 30 Blown 49 ft2 0.1 Wood _ 12 Under Attic (Vented) ENTRY 30 Blown 104 112 0.1 Wood 13 Knee Wall (Vented) GREAT ROOM 19 Blown 30 ft' 0.11 Wood WALLS ' Adjacent Cavity Width Height Sheathing Framing Solar Below - Space ... - - - u SW=>SE Exterior Concrete Block- Int InsGREAT ROO 4.1 26 0 9 10 255.7 ft2 0 0 0.3 0 _1 _ 2 NW=>S -Exterior .Concrete Block- Int InsGREAT ROO 4.1 21 0 9 10 206.5 ft2 0 0 0.3 0 3 NE=>NW Exterior Concrete Block - Int InS01ASTER BE 4.1 25 0 8 , 0 200.0 ft2 0' 0 - 0.3 0 1/8/2020 4:31 PM EnergyGauge®LSA 6.0.02.(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6. FORM R405-2017 - INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing "Solar Below Space -4 SW=>SE Exterior Concrete Block- Int InsNASTER BE 4.1 8 0 8 0 64.0 ft' 0 01 0.3 0 _5 NW=>S Exterior Concrete Block- Int lnsNASTER.BE 4.1 13 0 8 0 104.0 ft2 0 0. 0.3 0 NE=>NW Exterior Concrete Block - Intl lnsulM BATH 4.1 _ 9 0 8 0 72.0 ft2 0 0 0.3 0. _6 7'SW=>SE Exterior Concrete Block- Int lnsulKITCHEN 4.1 11 0 8 0 88.0 ft2. 0 0 0.3 0 _ 8 NE=>NW Exterior Concrete Block- Int InsdUNIOR-M. B 4.1, 14 0 8 0 112.0 ft' 0 0 0.3 0 -9 SW=>SE Exterior Concrete Block - Int lnsulPOWDER 4.1 5. 0 8 0 40.0 ft2 0 0 0.3 0 10 SW=>SE Exterior Concrete Block - Int maul NOOK 4.1 6 0 8 0 48.0 ft2 0 0 0.3 0 11 NE=>NW Exterior Concrete Block -Int lnsuLAUNDRY 4.1 ,3 0 8 0 24.0 It' 0 0 .0.3 0 12 SE=>NE Exterior Concrete Block- Int InsuLAUNDRY 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 13 SW=>SE Exterior Concrete Block: Int InsuLAUNDRY 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 14 SE=>NE •Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8 0 48.0ft2 0 0 0.3 0 15 N=>W Garage Frame -Wood :ENTRY 11 35 .8' 280.0.ft2 0.23' 0.3 0 DOORS # 'Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NE Insulated ENTRY None .32 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall : Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 SW=>SE 1 Metal Low-E Single Yes 1.04 0.29 N _ 46.4 ft2 1 ft ,0 1n 1. ft 5 In None None 2 •NW=>SW2 Metal Low-E Single Yes 1.11 0.27 N 40.0 It' 8 ft 0 in 1 ft 5 in None None _ 3 NW=>SW 5. Metal Low-E Single Yes 1.04 0.29 N 32.4 ft? 1 It 0 in 1' ft 5 in None None _ 4 'NE=>NW 6 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft2 1ft 0 in . 1 f1 5 in None None. 5 NE=>NW 8 Metal 'Low-E Single Yes 1.04 0.29 N 16.2 ft2 1 It 0 in 1 ft 5 in None None _ 6 SW=>SE 9 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft2 1 ft0 in 1 ft 5 in None None 7 SE=>NE 12 Metal, Low-E Single Yes 1.04 0.29 N 4.7 ft2 7 ft 0 in 1 ft 5 in None None GARAGE # Floor Area: `Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 35 ft 8 ft. 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH50 . 1 Wholefiouse Proposed.ACH(50) .000272, 1231.2 67.59 127.12 .097 5 , 118/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity _ Block Ducts 1 Electric Heat Pump/ None Singl HSPFi8.5 34.8 kBlu/hr 1 sys#1 - COOLING SYSTEM " # System Type Subtype Subtype Efficiency. Capacity Air Flow SHR Block Ducts "1 Central Unit' Split Singl SEER: 15 34.8 kBlu/hr 1044 cfm 0.85 .1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF " Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER -SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None .None ft' 'DUCTS " --supply — Return -- Air " CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT "" .QN RLF- Heat Cool 1 Attic 6 150 ft2 Attic 45 ft' Default Leakage Attic (Default) (Default) - 1 1 TEMPERATURES Programabl[e T]hermostaf[t:']Y Ceiling Fans: r[ Heating [X] Jan Mar Feb "" A May [[ ]] Jun [X] Jul May ] 4X] Aug DC] ]Sep j NovrI7�,rI�' Oct Nov Dec Venting [[ ]) Jan IIII 1111 Feb lx Mar l l lxl [JJ r [ lXl Jun [[ 11 Jul I ) Aug E. ] Sep l�l (X] [ ]Dec Thermostat Schedule: ,HERS 2006 Reference Hours Schedule Type 1- 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) " AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 •78 78 Cooling (WEH) AM 78• 7878 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78. . 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68' 68 68 68 68 66 66 . Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM' " 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space . Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH " Default(8 lbs/sq-.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft - 0.3 ENTRY Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY 1/8/2020 4:31 PM . EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction _ Space_ Default 81bs/s A ft. ft 0.3 GREAT/DINING 1/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE MANOR IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE MANOR 71 Permit Office:. ST.;LUCIE COUNTY City, State, Zip: • FT. PIERCE, FL, Permit Number: Y U Owner: WYNNE BUILDING CORP. Jurisdiction: _ Design Location: FL, Fort Pierce o COMPONENT AIR BARRIER CRITERIA' INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building: envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier, not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed.. ' Ceiling/attic The air barrier inany dropped ceiling/soffit shall be aligned with The Insulation in any dropped:ceiling/soffit the insulation and any gaps in:the air barrier shall be sealed. shall be aligned with the air barrier. Access. openings, drop down stairs or knee wall doors to , Unconditioned attic spaces shall be sealed. ' -Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers rsand headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the. cavity 'sealed. with material having a.thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. - Exterior thermal envelope insulation for framed ._ walls shall be installed in substantial contact and continuous alignment with the air barrier: Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. - Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed.to (including ..insulation. . maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on - the underside of floor framing and'extends from the bottom to the top of all perimeter floor framing ' members. (- Crawl space walls Exposed earth in unvented crawl spaces shall becovered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. • Batts in narrow cavities shall be cut to fit, or narrow. Narrow cavities, cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation 'Air sealing shall be provided' between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall:be air tight and IC rated. Plumbing andwiringBatt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on• . installatlon.readily conforms to available space shall extend behind ninina an wirino. Shower/tuff The air barrier installed at exterior walls adjacent to showers and Exterior walls. adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. I I ' be insulated. Electrical/phone box or The airbarrier. shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register bootsthatpenetrate building thermal envelope shall Abe sealed to the sub -floor or drywall. ' Concealed When required to be sealed, concealed fire sprinklers shall only be- sprinkled sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not beused to fill voids between fire snrinkler cover Mates and waliq or nellinas a. In addition, Inspection of log walls shall be in accordance with the provisions of ICC-400: 1/8/2020 4:36 PM EnergyGauge® USA 6.0:02(Rev. 1) - FlaRes2017 FBC 6th'Edition (2017). Compliant Software Page 1 of 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Duds, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b). Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1724 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 c)Area 7c. 153.4 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP' d) Gas furnace, natural gas AFUE a) Gas furnace, LPG AFUE f) Other 8.50 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRec%o g) Other 10131. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. IC) Whole house fan No 11c. 19.0 d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code ompliant features. Builder Signature: Date: Address of New Home: THE MANOR 71 ���Vd ( City/FL Zip: FT. PIERCE, FL 1/8/2020 4:36:22 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1