HomeMy WebLinkAboutElectrical PlanL 4 6 LL 4—7—_L.L 1.0-.2.........i..L- 10._-2 _. LL 21 —0 _�.L- -- -.... 37 5
+/-10'=0" AFF
EXISTING WOOD
TRUSS BOT.
CORD
9'-0" AFF
EXISTING ACOUSTIC
CEILING 2'x4' T—GRID
CLIP TOP OF NEW WALL
TO CEILING GRID
NEW FRAMED WALL:
1/2" GYP. BIRD BOTH SIDES OF
2x4, 25ga STUDS ® 16" o.c. w/
R-11 BATT INSULATION, TAPED &
PAINTED
FASTEN 25ga RUNNER TO SLAB
_w/ 'HILTI' SHOT PINS 'DNI 37P8'
(SHANK DIA. 0.145") OR
3/16"X1.5" TAPCON 0 16"O.C.
TYPICAL. SEAL BOTH SIDES
SMALL PARTITION MOFICATION
SCALE: 1 /2"=1'-O"
'HILTI' SHOT PINS
OR 3/16"X1.5"
TAPCON 0 16"O.C.
TYPICAL
SCREW
EACH
FLANGE
SLAB ON GRADE
co
�r-
=1c
0
Ln
se o u_r anr�umo., nnLL o o EXIT EXIT
O O F. E STOR.
e F. E, ( ❑ D.F. _ CLOSET
—IN WOMEN �—�I S.S. �Icv
WOMEN r� MEN BUSINESRECEPTI7:
RECEPTIOS)
STORAGE EMPLOYEE
0-)@ —
I I
�
X I I
w
go
O
e'e Oe
Oe
O
oeo
m1m
m1G .,.� �
oeo U—J11 _ .T1.
O =° °c DID
mo
O coeo
010
c
mG IG1m
p I
o1m
mounn I
DID II�—VNI
010
OFfI
'
GIG=°
010
j
0
1
1
O
me
o10
me
oeo
m1
GIG
01
.o
me
jI
oeo
me
oeo
me
oeo
O
1
O
111
me
j1
oeo
m1
oeo
m1
010
68 SF I s o w B S INESS 399 SF LC)
;_ OFFICE N
(BUSINESS)
--- — + + +
(1) OF EXISTING � T +
RTU S. SEE m c� DRAG 1 1
NEW VENTILATION & Ai � ° I 121 Sf
FRAMED ® MODEL NUMBERSam
WALL BELOW THIS PAGE ' c +NEW-F �- �- C
RAM_CD1 4'+ 31 "{_ 4- '— 91
mo
mm
EXISTING GAMING
ffYI AREA ruG
A-3: 2,730 SF "d
I ��
n_I�
1m
oeo
m,
oeo
101
m,m
O
1
O
toe
In
o10
: ::
oeo
101
an
O
1
O
rrrMFTTM
Lr- tsapiIl�::-
\IF.,
ii
---®•---®�
--®•
0
1
I
O
1m
o10
1m
GIG
m1
010
o
O
1
1
O
1m
o10
mo
am
Gm
0
1
O
em
00101
o10
,m
o10
1m
0
1
O
Im
kin-
1m
o
1
10
1m
Im
:::
GIG
1m
o10
o
1
1
O
1m
o10
1m
DIo
am
GIG
eel 0
eee o
eee 0
eee o
go
go
Bel p
Bee p
lee p
eee p
O
1
1
O
m1
Gm
mI
Gm
am
am
O
1
1
0
O
m1
m1
om
am
Gm
O
1
1
O
m1
0
mm
o=
m,
o
O
1
mI
G�
m1
G
m1
—
—
O
1
1
O
m1
mm
m,
Gm
m1
om
O
1
10
me
om
m1
om
mI
Gm
— — 11,33
ffilm iiiii�i�i`G�
�1
�� 1=1 Ijl — • Pl
1121
_-
�� ICI
- - - 1=i 1=i lip 1=i
oeo
GIG
0
O
'
GIG
+
ID
GO
DID
DIDDID
EXISTING FLOOR AREA IS NOT BEING CHANGED & IS EQUIPPED WITH EMERG.o_X 0 + a 0
LIGHTS, ILLUM. EXIT SIGNS & FIRE EXTINGUISHERS AS REQUIRED BY CODE / m,m + + OUR
oio 'U'" / agomo —� oio �—a + + 4- '
0 07 07 07 07 07 � 07 � V � �L...�' ` // 111-1
0 1 1 GIG L...T �S' 07+ via
oio
an 010 0
p ell p ele p Ili p eee p eee p ele p eel p eee p gee O Ill O ill O eee p Ill 0 ele p m p eee p eee p 111 p eae mo oio g$ O e O e O s O
Ulm
EXIT _ GIG
_ _ GeG
LOCK DOORS AX. TRAVEL LOCK DOOR
® DI NCE: 79'
# 7636
# 7632 69'-2" # 7634 19'-6"
EXISTING GAMING FLOOR AREA NEW GAMING FLOOR AREA
N TER OR FINISHES:
1. FLOORS:
EXISTING NON -SLIP FLOORING TO REMAIN;
2. ALL WALLS: EXISTING PAINTED 5/8" TYPE-X GYPSUM BIRD;
3. CEILING: EXISTING ACOUSTIC TILE & GRID TO REMAIN AS IS;
CONTRACTOR TO ENSURE ALL FINISHES MEET NOTE 6 BELOW.
4. ALL FURNISHING BY OWNER AND TO MEET NOTE 6 BELOW PER FBC 2017, TABLE 803.11,
5. INTERIOR WALL & CEILING FINISHES SHALL HAVE FLAME SPREAD INDEXES AS FOLLOWS:
INTERIOR EXIT STAIRS & EXIT PASSAGEWAYS, MINIMUM CLASS 'A';
INTERIOR CORRIDORS & ENCLOSURES FOR EXIT ACCESS TO EGRESS,
MINIMUM CLASS 'B';
OFFICES, GAME ROOMS, SUPPORT ROOMS & HALLWAYS: INTERIOR WALL AND
CEILING FINISH MATERIALS SHALL BE MINIMUM CLASS 'C';
CEILINGS A.C.T. FINISHES WHICH ARE CLASS A:
ALL INTERIOR WALLS ARE GYPSUM BOARD. CLASS A'
6. EXISTING INTERIOR OF EXTERIOR WALLS: PT 1X2 ® 24"O.C. w/ MIN. R-4.1 INSULATION
w/ GYPSUM BIRD. w/ PAINT FINISH;
CLASS A : FLAME SPREAD INDEX 25 OR LESS
CLASS B : FLAME SPREAD INDEX 26 TO 75
CLASS C : FLAME SPREAD INDEX 76 TO 200
HVAC FRESH AIR ADJUSTMENT:
THERE IS NO CHANGE TO THE EXISTING HVAC SYSTEM OR LAYOUT.
THE OCCUPANCY IS A-3 (ASSEMBLY), WHICH WILL REQUIRE THE FOLLOWING
ADJUSTMENT. BASED ON GAMING ROOMS USE PER FMC 2017, TABLE 403.3:
MINIMUM CALCULATED OUTDOOR AIR PER CODE FOR A-3:
(3,575 SF NET AREA/1000 SF x 20 PEOPLE x 0.18 CFM PERSON) + (7.5
CFM/PERSON x 3,550 SF NET AREA/1000 SF x 20 PEOPLE) =
13 CFM + 533 CFM = 546 CFM
ENSURE (3) FRESH AIR DAMPERS ON THE RTU'S ARE ADJUSTED FOR MIN.
200 CFM EACH.
AC ROOF UNITS: (3) GOODMAN, MODEL # ASPT61D14AC
Eg
LaEM J
FLOOR PLAN
SCALE: 1 /4"=1 '-0
ELECTRICAL SYMBOL LEGEND
® FIRE EXTINGUISHER
TYPE 2A 1013C
EMERGENCY
FLOOD LIGHT W/
BATTERY BACK—UP
EMERGENCY
w FLOOD LIGHT W/
EXIT SIGN COMBO
PLUMBING FIXTURES CALC:
PLUMBING FIXTURES PER TABLE 403.1 2007 FPC:
FOR 138 MALES: 138/125 = 2 WC:
FOR 138 FEMALES: 138/65 = 3 WC;
LAV'S AT 1 /200 PEOPLE = (1) FOR EACH GENDER;
(1) SERVICE SINK REQUIRED;
(1) DRINKING REQUIRED;
PLUMBING PROVIDED:
MENS: (1) WC, (1) URINALS, (1) LAVATORY;
WOMENS: (3) WC, (2) LAVATORY;
(1) SERVICE SINK;
(1) DRINKING FOUNTAIN;
PLUS (1) PRIVATE WC & (1) PRIVATE LAV.;
EXISTING
PRIVATE
RESTROOM
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BQCC
RAYMOND
CHLADNY AIA
DIGITALLY SIGNED BY RAYMON
CHLADNY, Al
ADVANCED ARCHITECTUR
EMAIL: SOCRATESHILL@GMAIL.CO
DATE: 2020, 03 17 9:11:1
1�1�`w.&'u
(772)631-5709 AA26002573
THESE DRAWINGS CONTAIN
ARCHITECTURAL SYMBOLS
USED FOR GRAPHIC
PURPOSES ONLY. SIZE ANI
LOCATION MAY VARY TO
MEET MANUFACTURER'S
SPECIFICATIONS.
DO NOT SCALE DRAWINGS.
ANY QUESTIONS ABOUT
DIMENSIONS, CONTACT
DESIGNER.
START DATE: 05.19.19
NO.REVISION/ISSUE DATE
1ST —REVISION
08.12.19
2ND—REVISION
09.09.19
3RD—REVISION
02.27.20
4
4TH_REVISION
03.17.20
GLIENT:
DOUBLE UP ARCADE
7632-7636, S. FEDERAL
HIGHWAY
PORT ST. LUCIE, FL
Ro=y.:Chladny
LlwnGnd A1ChitaCt #AR_ 017475
A=1