Loading...
HomeMy WebLinkAboutReview CommentsPlanning & Development Selvicas ,Buildfhl & Code RegLdaflondivision 2300 V9rglnia Avenue FartPtarca;Ft_ 3082 PROPERTY INFORMATION Address: 123 Queen Frederika Ct City / State I Zip: Fort Pierce, FI 34949 Parcel 1414-701-0035-000/0 Zoning: RS4 1 Owner(s): Tammie R Cox / Timothy A Winegardner Jurisdiction: SAINT LUCIE COUNTY Si%'fl APPLICATION INFORMATION Permit Number: 1912-0472 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Karen A Gordon Business Name: Paradise Homes Group Business Addr: 575 Nw Mercantile Place # 109 City / State I Zip: Port St Lucie, FI 34986 REVIEWS AND COMMENTS Block: 4 Automatic Sprinkler System? No Fax Number: 772-621-4664 Email: Permitting@Paradisehomes fl.Com Review Tvne Status Reviewed By Date Started Date Comnloted Date Released ADDRESSING ASSIGNMENT COMPLETE Lori Bender 1/3/2020 1/7/2020 1/7/2020 Comment: DOCUMENTS MISSING PENDING Deanna Givens 12123/2019 12/2312019 Comment: NOTICE OF COMMENCEMENT 12/2312019 Comment: VEG PERMIT SENT TO ERD. VEG PERMIT IN DRAWER UNDER "C" COX. NO FEE 12/2312019 Comment: FILLED LANDS AFFIDAVIT 12/2312019 Comment: ROOFING SUB AGREEMENT 12/2312019 Comment: HVAC SUB AGREEMENT 1213112019 Comment: COPY OF RECEIPT FOR PAID UTILITY WATER 12/3112019 Comment: HOA APPROVAL LETTER. ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzol 1/3012020 1/212020 1/212020 Comment: FRONT COUNTER REVIEW COMPLETE Deanna Givens 12/2312019 12123/2019 1212312019 Comment: NOTIFIED FOR PICK UP PENDING Comment: Planning A Developmebt Services Stfildi 1g] & Code Regx latiao Division VQD1nMIltiaAvenvs Fort P]erce, FL. 34982 REVIEW COMMENTS PLANS EXAMINER REVIEW INCOMPLETE Jpi, Inc -Andrew 1/8/2020 117/2020 Comment: 1) SOIL REPORT REQUIRED. (R401.4) 1f7/2020 Comment: 2) DRAINAGE PLAN REQUIRED. 1f712020 Comment: 3) EXPOSURE CATEGORY IS INCORRECT. (R301.2.1) 1/7/2020 Comment: 4) NO FOUNDATION PLAN WAS PROVIDED. (R401.1) 1f712020 Comment: 5) FIX CONFLICT WITH ATTIC INSULATION VALUE -ARCH. DWGS VS ENERGY CALCS. ([A] 107.2.1) 1/7/2020 Comment: 6) PROVIDE ATTIC/SOFFIT VENT SIZE & LOCATION REQUIRED TO MEET (R806.1). 11712020 Comment: 7) PROVIDE PRODUCT APPROVALS FOR BAHAMA SHUTTERS. ([A] 107.2.1) Comment: 8) PLEASE CHECK THE GARAGE DOOR SPECIFICATIONS- SHEET 2 SHOWS REQUIED PRESSURES WHICH 117/2020 EXCEED THE PRODUCTS RATED PRESSURE IN THE PRODUCT APPROVAL AFFIDAVIT. MODEL # W5 DOES NOT APPEAR IN THE PRODUCT APPROVAL. (R609.2) 1f7/2020 Comment: 9) PRODUCT APPROVAL NUMBER 15278.13 DOES NOT EXIST. ([A] 107.2.1) 1/8/2020 Comment: 10) TRUSS DRAWINGS REQUIRED. ([A] 107.2.1) Comment: 11) PLEASE PROVIDE A DETAILINOTE FOR FIRE BLOCKING. SPECIFY ON PLANS THE INSTALLATION OF 1/812020 FIREBLOCKING FOR THE FOAM INSULATION AGAINST MASONRY. (R302.11) 118/2020 Comment: 12) PROVIDE FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR INSULATION. (R302.10) Comment: 13) PROVIDE CONSTRUCTION DETAILS/SPECIFICATIONS FOR DECORATIVE TRELLIS AND BRACKETS 1/8/2020 ATTACHED TO THE BUILDING. ([A] 107.2.1) 1/812020 Comment: 14) PROVIDE FLASHING DETAILS FOR ALL OPENINGS. (R703.4) Comment: NOTE- PRELIMINARY PLAN REVIEW STARTED, MULTIPLE DOCUMENTS ARE MISSING. ADDITIONAL 1/8/2020 COMMENTS MAY BE ISSUED UPON RECEIPT OF MISSING DOCUMENTS. ([A] 107.2.1) ZONING REVIEW INCOMPLETE Lydia Galbraith 1213112019 Comment: PLEASE PROVIDE 2 SIGNED AND SEALED SURVEYS. THE SUBMITTED SURVEYS ARE COPIES AND HAVE 12131/2019 NO SIGNATURE AND SEAL. 12131/2019 Comment: PLEASE PROVIDE COPY OF THE PERMIT FROM THE HEALTH DEP. FOR SEPTIC. 12/31/2019 Comment: PLEASE PROVIDE TWO FLOOR PLANS AND TWO SURVEYS WITH STAMP FOR APPROVAL HEALTH DEP. Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS 12/31/2019 EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.