Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: COX RESIDENCE BuilderName: PALDISE AE7pormi,_ Street: 123 QUEEN FREDERIKA CT. PermitOffioe: ST.UNTCity, Stale, Zip: FT. PIERCE, FL, 34949 PermilNumber:FOwner: TAMMIE COX Jurisdiction: 661rDesignLocation: FL, Fort Pierce County: St.N8 2lo 1. New construction or existing New (From Plans) 9. Wall Types (2347.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int lnsul, Exterior R=4.1 1997.30ft2 b. Frame- Wood, Adjacent R=19.0 350.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Numberof Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (2304.0 sqft.) Insulation Area 5. Is thisaworst case? No a. Under Attic (Vented) R=38.0 2304.00 W 6. Conditioned floor area above grade (ft2) 2304 b. NIA R= ft2 Conditioned floorarea belowgrade(ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(352.4 soft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 275 a. U-Factor: Sgl, U=0.58 352.44 ft2 SHGC: SHGC=0.24 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 48.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 48.0 HSPF:9.00 SHGC: Area Weighted AverageOverhang Depth: 5.625 ft. Area Weighted Average SHGC: 0.240 14. Hotwatersystems a. Electric Cap: 50 gallons 8. Floor Types (2304.0 soft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2304.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area:, 0.153 Total Proposed Modified Loads: 68.59 PASS Total Baseline Loads: 79.65 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. f. rinrr 2 a O PREPARED BY: Before construction is completed DATE: 12-20-19 this building will be inspected for compliance with Section 553.908 ;4 ■ ° c I hereby certify that this building, as designed, is ' compliance Florida Statutes. lj,, �y� with the Florida Energy Co e.fVE'- OWNER/AGENT- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 12/19120196:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Pagel of FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: COX RESIDENCE Bedrooms: 3 Address Type: SVeetAddress Building Type: User ConditionedArea: 2304 Lot# OwnerName: TAMMIE COX Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: BuilderName: PARADISE HOMES RotateAngle: 0 Street: 123 QUEEN FREDERIK Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: 6611000 Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Single-family FL, 34949 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V Designt-ocation TMYSite 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2304 24791.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER SUITE 351 4001.4 No 0 1 1 Yes Yes Yes 2 WIC 36 360 No 0 1 Yes Yes Yes 3 WIC2 35 350 No 0 1 No Yes Yes 4 TILT. 24 240 No 0 1 Yes Yes Yes 5 MASTER BATH 222 2220 No 0 1 Yes Yes Yes 6 FOYER 72 1008 No 0 1 Yes Yes Yes 7 STUDY 121 1210 No 0 1 Yes Yes Yes 8 GREAT ROOM 486 5832 No 2 1 Yes Yes Yes 9 LAUNDRY 63 630 No 0 1 No Yes Yes 10 HALL 102 1020 No 0 1 No Yes Yes 11 KITCHEN 247 2470 Yes 0 1 No Yes Yes 12 CAFE 151 1510 No 0 1 Yes Yes Yes 13 POOL BATH 53 530 No 0 1 Yes Yes Yes 14 BEDROOM #3 142 1420 No 2 1 1 Yes Yes Yes 15 GUEST SUITE 136 1360 No 2 1 1 Yes Yes Yes 16 GUEST BATH 63 630 No 0 1 No Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER SUITE 34ft 0 351 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulation WIC 61t 0 36 112 ---- 0 1 0 12119/20196:06 PM EnergyGaugeO USA 6.0.02(Rev.t)=--1 Res2017 FBC 6th Edition(2017) Compliant Software Page 2of6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpet 3 Slab -On -Grade Edge Insulation WIC2 1ft 0 35 ft2 ---- 0 1 0 4 Slab -On -Grade Edgelnsulation TLT. 4ft 0 24 ft2 ---- 0 1 0 5 Slab -On -Grade Edgelnsulation MASTER BATH 39ft 0 222 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulation FOYER 9ft 0 72 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulation STUDY 16ft 0 121 ft2 _--- 0 1 0 8 Slab -On -Grade Edge Insulation GREAT ROOM 18ft 0 486 ft2 ---- 0 1 0 9 Slab -On -Grade Edgelnsulation LAUNDRY 1 ft 0 63 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulation HALL 1 ft 0 102 ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulation KITCHEN 1 ft 0 247 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulation CAFE 24ft 0 151 ft2 ---- 0 1 0 13SIab-On-Grade Edge Insulation POOL BATH 15ft 0 53 ft2 ---- 0 1 0 14SIab-On-Grade Edge Insulation BEDROOM#3 14ft 0 142 ft2 _--- 0 1 0 15SIab-On-Grade Edge Insulation GUEST SUITE 9ft 0 136ft2 --_- 0 1 0 16Slab-On-Grade Edge Insulation GUEST BATH 1 It 0 63 ft2 ---- 0 1 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Compasitionshingles 2577 ft2 0ft2 Medium N 0.6 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2304 ft2 N N 12/19/2019 6:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) MASTER SUITE 38 Blown 351 ft2 0.1 Wood 2 UnderAttic(Vented) WIC 38 Blown 36 ft2 0.1 Wood 3 UnderAttic(Vented) WIC2 38 Blown 35 ft2 0.1 Wood 4 UnderAttic(Vented) TLT. 38 Blown 24 ft2 0.1 Wood 5 UnderAttic(Vented) MASTER BATH 38 Blown 222 ft2 0.1 Wood 6 UnderAttic(Vented) FOYER 38 Blown 72 ft2 0.1 Wood 7 Under Attic (Vented) STUDY 38 Blown 121 ft2 0.1 Wood 8 UnderAttic(Vented) GREAT ROOM 38 Blown 486 ft2 0.1 Wood 9 UnderAttic(Vented) LAUNDRY 38 Blown 63 ft2 0.1 Wood 10 UnderAttic(Vented) HALL 38 Blown 102 ft2 0.1 Wood 11 UnderAttic(Vented) KITCHEN 38 Blown 247 ft2 0.1 Wood 12 UnderAttic(Vented) CAFE 38 Blown 151 ft2 0.1 Wood 13 UnderAttic(Vented) POOL BATH 38 Blown 53 ft2 0.1 Wood 14 UnderAttic(Vented) BEDROOM#3 38 Blown 142 ft2 0.1 Wood 15 UnderAttic(Vented) GUEST SUITE 38 Blown 136 ft2 0.1 Wood 16 UnderAttic(Vented) GUEST BATH 38 Blown 63 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE Exterior Concrete Block- Int lnsLMASTER SUI 4.1 2 0 11 4 22.7 ft2 0 0 0.6 0 _ 2 SW Exterior Concrete Block- Int Ins0AASTER SUI 4.1 16 0 11 4 181.3 ft2 0 0 0.6 0 3 NW Exterior Concrete Block- Int lnsUMASTER SUI 4.1 16 0 11 4 181.3 ft2 0 0 0.6 0 _ 4 SW Exterior Concrete Block- Int Insul WIC 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 _ 5 SW Exterior Concrete Block- Int Insul TILT. 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 6 NE Exterior Concrete Block- Int lnsuMASTER BA 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 7 BE Exterior Concrete Block- Int lnsuMASTER BA 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 _ 8 SW Exterior Concrete Block- Int InsuMASTER BA 4.1 17 0 10 0 170.0 ft2 0 0 0.6 0 _ 9 SE Exterior Concrete Block- Int Insul FOYER 4.1 9 0 14 0 126.0 ft2 0 0 0.6 0 10 NE Exterior Concrete Block - Intlnsul STUDY 4.1 1 0 10 0 10.0 ft2 0 0 0.6 0 11 BE Exterior Concrete Block-Intlnsul STUDY 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 12 SW Exterior Concrete Block-Intlnsul STUDY 4.1 3 0 10 0 30.0 ft2 0 0 0.6 0 13 NW Exterior Concrete Block- Int lnsuGREAT ROO 4.1 18 0 12 0 216.Oft2 0 0.6 0 14 SW Exterior Concrete Block- Int Insul CAFE 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 15 NW Exterior Concrete Block - Int Insul CAFE 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 16 NE Exterior Concrete Block- Int lnsuPOOL BATH 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 17 NW Exterior Concrete Block - Int InsuPOOL BATH 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 18 NE Exterior Concrete Block- Int InsuBEDR00M # 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 19 NE Exterior Concrete Block- Int lnsuGUEST SU IT 4.1 9 0 10 0 90.0 ft2 0 0 0.6 0 20 N Garage Frame -Wood GUEST BAT 19 35 10 350.0 ft2 0 0.5 0.600000 0 12/19/2019 6:06 PM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Omt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 BE Insulated FOYER None .39 6 8 48 ft2 2 NW Insulated POOLBATH None .39 2 10 8 22.7 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 3 Vinyl Low-ESingle Yes 0.58 0.24 Y 72.0 ft' 7 ft 0 in 0 It 6 in None None 2 SW 5 Vinyl Low-ESingle Yes 0.58 0.24 Y 6.0 ft2 2 ft 0 in 1 ft 0 in None None 3 SE 7 Vinyl Low-ESingle Yes 0.58 0.24 Y 3.4 ft2 2 It 0 in 1 ft 6 in None None 4 SE 7 Vinyl Low-ESingle Yes 0.58 0.24 Y 16.0 ft2 2 It 0 in 1 It 0 in None None 5 SW 8 Vinyl Law-ESingle Yes 0.58 0.24 Y 15.0 ft2 2ft0in 1ft0 in None None 6 BE 9 Vinyl Low-ESingle Yes 0.58 0.24 Y 12.0 ft2 6 ft 0 in 6 ft 0 in None None 7 BE 11 Vinyl Low-ESingle Yes 0.58 0.24 Y 36.0 ft2 2 ft 0 in 2 It 0 in None None 8 NW 13 Vinyl Low-ESingle Yes 0.58 0.24 Y 96.0 ft' 9 ft 10 in 0 It 6 in None None 9 SW 14 Vinyl Low-ESingle Yes 0.58 0.24 Y 15.0 ft2 9 It 10 in 0 ft 6 in None None 10 NW 15 Vinyl Low-ESingle Yes 0.58 0.24 Y 45.0 ft2 2 It 0 in 1 It 0 in None None 11 NE 16 Vinyl Low-ESingle Yes 0.58 0.24 Y 6.0 ft2 2 It 0 in 0 ft 6 in None None 12 NE 18 Vinyl Low-ESingle Yes 0.58 0.24 Y 15.0 ft2 2 ft 0 in 1 ft 0 in None None 13 NE 19 Vinyl Low-ESingle Yes 0.58 0.24 Y 15.0 ft2 2 ft 0 m 1 ft 0 in None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 945 ft2 945ft2 35 ft loft 19 INFILTRATION # Scope Method SLA CFM 50 ELA EgI-A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000342 2065.9 113.42 213.3. .1334 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:9 48 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 48 kBtu/hr elm 0.7 1 sys#1 12/19/2019 6:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50gal 60.9 gal 120deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # CompanyName System Model# Collector Model# Area Volume FEF None None ft' DUCTS ---Supply--- --Return-- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area LeakageType Handler TOT OUT ON RLF Heat Cool 1 Attic 6 275W Attic 65 ft' DefaultLeakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programabl[eT]]hermostat::Jan[ Cffeiling Fans: Feb ]]N Heating [X] JNov an [X] Feb r Mar X r [[X]� [IX1� [[X]] r[[[] ] r [f OctOct Dec Dec Venting [[ ]] Jan [[ ]] Feb X Mar Apr [ MaM:yy [ ] Jun [ ] Jul [ ] Aug lXJ Sep [ NNov ov ThermostatSchedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.ft. 0 ft' 0 ft 0.3 MASTER SUITE Default(8lbs/sq.ft. ft' ft 0.3 WIC Default(8lbs/sq.ft. ft' ft 0.3 WIC2 Default(8lbs/sq.ft. ft' ft 0.3 TILT. Defaull(8 lbs/sq.ft. ft' ft 0.3 MASTER BATH Defaull(8 lbs/sq.ft. ft' ft 0.3 FOYER Default(81bs/sq.ft. ft' ft 0.3 STUDY. Default(8lbs/sq.ft. ft' ft 0.3 GREAT ROOM Default(8lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8lbs/sq.ft. ft' ft 0.3 HALL Default(8lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8lbs/sq.ft. ft' ft 0.3 CAFE Default(8lbs/sq.ft. ft' ft 0.3 POOL BATH Default(8lbs/sq.ft. ft' ft 0.3 BEDROOM #3 Default(81bs/sq.ft. ft' ft 0.3 GUEST SUITE Default 8lbs/s .ft. ft' ft 0.3 GUEST BATH 12/19/2019 6:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6