Loading...
HomeMy WebLinkAboutCertification for Design Load ComplianceProject Name: Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliancy"*' Cox Residence L,Ij Ias Project Address: 123 Queen Frederika Ct, N Hutchinson Island, FL Permit #: Occupancy Type: R-3 Construction Type: V-13 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all pe it appIRPffi@@ i Wmg the fpRowing: o New Residences (single or multi -family) o Residential Addition DEC 23 2019 1 o Any accessory structure requiring a building permit o Any non-residential structure. ST. Lucie County, Permitting * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Residential Code Fifth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed __Partially Enclosed _Open 3. Risk Category: _I X 11 _III _IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 mph X ASD _LRFD 'End Zone Width: 5.18 ft 5. Mean Roof Height 15.83 ft Roof Pitch: --> :12 Parapet: --� ft (See Sh 2 or 3) 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings) Zone 1: --> Zone 2: --> Zone 3: --> Zone 4: --> Zone 5: --> Garage: --> (See Sh 3) 7. Design Loads: Floor: 55 PSF Roof/Dead: --' PSF Roof/Live: 20 Balcony: ss PSF (See Sh 5) Dock: 40 PSF Deck: 55 PSF Stairs: 40 PSF Fence: N/A PSF Railings: 50 plf PSF R. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. i Is A Continuous Load Path'Provided? X Yes _Not Applicable Explain Why Not 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions;of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: - Steve Kastner, PE 39528 Print Name Cert # & Co. Cert Auth. Kastner Engineering, LLC DEC 01 Nig Signature, Date,: and Seal 5320 Florida Palm Ave, Cocoa, FL 32927 Company Name & Address Revised07/25/2614 Residential Standard Calculation an 1997 RECEIVED n+a. Version 2011 L STEP 1 Article 220.42 & 220.52 r" w ears HIV 2304 General Lighting load 6,912 VA 6 Small Appliance 9,000VA [ST� 1 Laundry circuit 1,500 VA tc cJe County, Pom Gen. Lgt, Sm App.& Laun. Load 17,412 VA - - - -------A Residence of rt Control Services 1;07 SW Biltmore St PSL, FL, 34983 Telephone & Fax 3,000 VA @ 100%= 3,000 VA 14,412 VA @ 35%= 5,044 VA VA @ 25% = VA STEP 2 Article 220.50 & 220.51 RI General Lighting Demand Load 8,044 VA A/C Condenser & Fixed Electric Space Heating CITY Total 1 FAIC VA AHU 1Fw- 11,600 VA Iry Heating Load 11,600 VA VA AHU 2 VA CU Load VAVA AHU 3 VA VA AHU4VA Greater of Heat@ 100%vs.A/C@100% 11,600 VA VA AHU5 VA ° STEP 3 Article 220.53 Appliance Demand Load 23,558 VA •503vA 1 Water Heater 4,500 VA !A00VA . 2 Refrigerator 2,800 VA Dryer Demand Load 5,000 VA ecovA _- Freezer VA +.owvA V 1 Dishwasher 1,030 VA Range Demand Load 6,400 VA 6sm . 1 Disposal 690 VA aoovA V R I Hood VA Service Demand 54,602 VA 11MVA 1 Microwave 1,630 VA ❑ 4000vA '. Microwave VA Demand Load 228 A M)VA ,. Mini Refrig VA ❑ p4WVA Wine ClrVA Neutral Demand 91A v Insta Hot VqvA _ Ironing Center VA Min.Service Req. 250 A ❑ ;.I. V Jacuzzi Tub VA - ❑ --- -- - _ .: Sprinkler Pump 1,127 VA Min. Feeder size 410 ❑ Wen w Well Pump VA Min. Neutral size 3 Selen Fountain Pump VA Eq. Grding Cond. 4 lat . Elevator VA ❑ Copper Pool Equip. Panel 14,725 VA 100 % Demand ❑ GATES VA No Demand ❑ Other load VA No Demand Total Appliance Load 26,502 VA 4 or more demand @ 75% plus 100% demand loads 23,558 VA STEP 4 Article 220.54 Electric Clothes Dryers 5,000 VA STEP 5 Article 220.65 Electric Ranges Cal C demand 8000 1 or Number of appliances 1 Cooktop Col B demand ❑ check Box for Gas Range Cooktop Col B demand Oven(s) 8,000 W Col B demand Oven(s) Col B demand Number of appliances 1 Dem. Factor 80% Cooktop & Oven Demand Load 6,400 W Pool Panel Feeder Calculation Continuous Motors Non -continuous Spa heater 11 kVA Pool heater 3.5 ton Pool heater 5 ton Pool Light eeiea `1 Blower f.5 hp '.,, other load other loatl ❑ Min.Co er Pool Feeder (See Note) 2,300 ...... 0 ... .. 0 ... 1 0 ...... 2300 ❑ 24ov 0 ❑ 240v 0 ❑ 24ov # 6 AWG A B N 1150 1150 0 0 0 0 0 0 0 0 5063 5063 0 0 0 1150 1150 0 0 0 0 i 0i 0 0 61 Al61 A A Minimum Panel Rating 100A Phase Amperes Neut. load Continuous Motors 1.5 hp ..❑ 24ov eekn ❑ 240v eelen .. ❑ 24ov seten '-il ❑ 240v Non -continuous Motors :elect :. 0 24ov =elect 141 ❑ 240v sekn �- ❑ 240v S,;-; � ❑ 24w .eat ❑ 240v 0.0 Motor Neutral Load Max.Unbalanced Neutral Load