Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Subsoil Investigation Report
/9 is-OY?a-- Subsoil Investigation Report prepared by: ting, Inc© ent: Tannic Cox gtact: Jordan Kane dress: 123 Queen Frederika Court Fort Pierce, FL 34949 jecr Proposed Residence and Pool Press: 123 Queen,Frederika Court Fort Pierce, FL 34949 e: Wednesday, February 6,2019 als Testing l InspectlAIII Environmental am � 5r<I} Phone: 954-784-2941 E-Fax: 954-784-7875 m Table of Contents Client Information Project Information ----------------------------- -------------------------------------- ---pg. 1 General 'Soil Descriptions ------------------ -------------------- --------------------- pg. 1 Foundation Recommendations ------------- ---------------- — --- -- ------------- — ----- pg. 2 Excavations------------------------------- —---------- ----------------------------------- —Pg 3 Grading------------------- ------------ —------------ —-------------------- —----------------- -Pg. 3 Appendices----- --- -------------- ------------- -------- — --------- — ------------- -------- pg. 4 Soil Boring Log(s) Laboratory Test(s) Project Location Soil Boring Location(s) Soil Classifications Sampling Procedures Limitations of Liability For Your Information Our findings in this report are based on soil conditions encountered in the test bore locations only, proposed structure to be built, (if available at this stage), Florida Building Code requirements and standard engineering practices. If your report is preliminary (i.e. vacant land or building to be demolished) additional borings are required within the foot print of the proposed structure once the location & layout of the proposed structure is known. Please read this report in its entirety and follow all recommendations. Failure to do so may result in the permitting agency (Building Department, etc.) withholding ,the Certificate of Occupancy. This will cause delays and additional costs. The Permitting Agency will require a final certification or signing off of the project prior to issuing the Certificate of Occupancy. All of our recommendations need to be followed to receive a final certification from F.E.T., including densities on each lift, demucking verification, piling inspection, etc., whichever recommendation applies to your project. " Please schedule us at least 24 hours in advance for all tests and inspections. If you choose to use another Engineering Firm, you must verify they will provide you with the proper certification in writing, as outlined in our report. Our firm will only provide a certification letter if it has verified all work as recommended in our report. 3370 NERh Avonuc ,Oak Iand•Park.•Florid a.33334 ""-.+te€.„+.• em-a CMEC .-• OR • �, ■T ©ederal Ogngineering esting, Inc. Wednesday, February 6, 2019 Tammle Cox 123 Queen Frederika Court Fort Pierce, FL 34949 Ann.: Jordan Kane RE: Subsoil Investigation Proposed Residence and Pool 123 Queen Frederika Court Fort Pierce, FL 34949 Dear Sirs: Phone: 954-784-2941 E-Fax: 954-784-7875 Job Order Number 19SB060 .com Pursuant to your request, Federal Engineering & Testing, Inc. has completed a subsoil investigation on 02/04/2019 at the above referenced site. The purpose of our investigation was to verify subsoil conditions relative to foundation preparation and design. A total of three (3) SPT borings were performed according to ASTM D-1586, one (1) drilled down to a depth of thirty feet (30), one (1) drilled down to a depth of twenty-five feet (25), and one (1) drilled down to a depth of fifteen feet (15), below the existing ground surface. (See attached field sketch for locations). The following is a general description of soil stratas for the subject site: pePO! Descnptron of Soils , ! From :' 'fo 0" 6" Topsoil & Vegetation 6" 3' Brown Sand 3' 6' Light Gray Sand with Shell 6' 11' Gray Silt with Traces of Organics 111 15' Gray Sand with Shell 15' 20' Bluish Gray Clay 20' 30' 113luish Gray Sand with Shell Groundwater table elevation was measured immediately at the completion of each boring and was found at an average depth of three (3) feet below existing ground surface. Fluctuation in water level should be anticipated due to seasonal variations and run off as well as varying ground elevation, construction dewatering and pumping activities in the area. Site contractor must familiarize himself with site conditions in the event groundwater controls and dewatering is needed. Surface flooding may result under hurricane conditions and should be taken into consideration in the design of the project. The contractor shall make sure that groundwater levels on adjacent properties are not affected by the contractors dewatering activities. Specialty groundwater contractors shall be consulted for all work below the groundwater level. The boring log(s) attached present a detailed description of the soils encountered at each location. The soil stratification shown on the boring log(s) is based on the examination of the recovered soil samples and interpretation of the driller's field log. It indicates only the approximate boundaries between soil types. The actual transitions between adjacent soil types may be gradual. Wednesday, February 6, 2019 123 Qoeen Frcderika Court Fort Pierce, FL 34949 Page 2 ederal ngineering K esting, Inc. Based on our understanding of the proposed structure and the information obtained from our field boring logs; it is evident that deep foundation systems are needed to support the proposed new structure without detrimental settlement to the structure. Per the Florida Building Code FBC 2017, Chapter 18; deep foundation systems shall consist of one of the following alternatives: Alternatives ' ' Approximatte Depth Driven Size • Allowable Com ression Pile ; = Capacity 1n Tons Allowable Tension Prle t;apaclty m , •. Tpps ` Allowable Lateral Capacity: Tons Pin Piles/ Push Piers 30' or Refusal 4 Inch 5 Tons 1 Ton N/A Helical Piles 30' or Refusal 3 Inch 12 Tons 6 Tons N/A Auger Cost Piles 30' BELS 12 Inch 25 Tons 12 Tons I Ton Auger Cast Piles 30' BELS 14 Inch 35 Tons 17 Tons 2 Tons "BELS - Below Existing Land Surface's Estimated Lateral Load for a Pile Top Deflection of '/4 inch. Proposed pile length based on the existing ground elevations at the time of drilling. Pile length may vary depending on proposed grade beam elevations and inconsistent soil profiles. In the case of pin, helical and precast piles a minimum of four (4) test piles shall be driven to determine production pile length. All work shall be in accordance with the local Building Code and Coastal Zone Construction Requirements (if required). Helical pile bearing capacity is dependent on helix numbers, size and spacing. The foundation contractor will be able to provide the most cost effective combination of helix designs. The above depths are the minimum depths required to achieve design capacities. Predrilling might be required to achieve design depths. All slabs and pool decks for the subject structure shall be designed as structural slabs spanning between supports and designed by a Florida Registered Structural Engineer and placed under the supervision of a Geotechnical Engineer. All work shall be conducted by an experienced Florida Licensed Specialty Piling Contractor. All piles shall be designed by a professional engineer and shall be placed under the supervision of our Geotechnical Engineer to verify compliance with our recommendations. If the pile is not reinforced over the entire length, we recommend a single #7 reinforcing steel bar be placed the full length of the pile to verify pile continuity. In case of existing structures in the vicinity of the pile driving operation, care shall be taken not to create excessive vibration. Vibration levels shall be monitored to verify compliance with county regulations. Steps must be taken to prevent excessive vibrations. In the event excessive vibrations are experienced during construction, alternative driving methods shall be implemented (i.e.: predrilling, jetting, hydraulic push, etc...). The minimum center to center spacing of piles or adjacent foundations shall be not less than twice the average diameter for round piles or 1-3/4 times the diagonal dimensions of rectangular piles, but in no case less than 30 inches. The installation of adjacent piles (located within 4 feet of each other) on the same working day is not recommended. We recommend that adjacent piles not be installed until the initial grouted pile has set overnight. The grout used in the pile installation shall develop a minimum compressive strength of 4000 PSI at 28 days. 2r I _ Wednesday, February 6, 2019 123Queen Frederika Court Fort Pierce, FL 34949 Page 3 deral efgIneer �81�81 QQ��nglneering eating, Inc, Any underground structures such as grease traps, septic systems, etc. must be supported on pile foundations, unless the deleterious material (i.e.: silt, muck; peat, ,etc ... ) is excavated in its entirety and replaced with compacted washed gravel such as pea rock or #57 stone below the water table elevations and clean granular materials above the water table. Excavations shall not extend within one (1) foot of the angle of repose next to existing footings or structures unless underpinned. Trenching shall be in compliance with the Florida Building Code, OSHA and Trench Safety Act requirements. Shorings shall be designed and inspected by a Florida licensed professional engineer. Provisions shall be made by the architect, engineer of record and contractor to address differential settlements when tying in new to existing structures. Mixing of different foundation types shall not be used unless provided with expansion joints to address differential settlement. All outside ground' surfaces must be sloped away from the structure to avoid water accumulation and ponding. All rain waters shall be discharged away from all building foundations. Verify all water, sewer, plumbing, sprinkler and drainage lines are properly functioning with no leaks in the vicinity of the foundation. Regardless of the thoroughness of a geotechnical exploration, there is always the possibility that conditions may be different from those of the test locations; therefore, Federal Engineering & Testing, Inc. does not guarantee any subsoil condition between the bore test holes. A site plan showing the location of the proposed stricture was not provided at the time the soil borings were performed. Once plans and specifications have been finalized and drawn, Federal Engineering & Testing, Inc. shall be provided a copy of the finalized plans and specifications for review. For a more accurate portrayal of subsurface conditions, the site contractor should perform test pits. If different conditions are encountered, Federal Engineering 8c Testing Inc., shall be notified to review the findings and make any recommendations as needed. In accepting this report the client understands that all data from the soil borings is intended for foundation analysis only and is not to be used for excavating, backfilling or pricing estimates. The site contractor -must familiarize themselves with the job site conditions. Environmental analysis of the soil materials is not part of the scope of services. If environmental analysis of the soils is required, we can provide a proposal for performing an environmental analysis of the soil materials. For Environmental due diligence, a Phase I and/or Phase lI Environmental Site Assessment is recommended. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Federal Engineering & Testing, Inc. appreciates the opportunity to be of service to you at this phase of your project. Please feel free to contact us i. Nyp,nlay be of further service to you.. Sincerely, Keith LeBlanc, PZ ro 1 2,5� * Federal Engineering;gTestiF ;'� Florida Reg. No. 50. ; ZoRtoP.'" Certificate of-Authorizat49L AA , Wednesday, Fcbruary 6, 2019 123 Oueen Frederika Court Fort Pierce, FL 34949 Page 4 Appendices ederai ® ngineering 8 esting, Inc. O ederai Phone: 954.784.2941 E-Fax: 954-784-7875 OQegineering www.fed-ong.com www.fed-eng.cam ®vesting, Inc. SPT Test Boring Report Client: Tanunie Cox Date of Test: February 4, 2019 Project: Proposed Residence and Pool Hole No.: B-1 Address: 123 Queen Frederika Court Location: See Attached Drawing Fort Pierce, FL 34949 Depth (FT) Soil Descriptions Hammer Blows 'IN" 1 0" - 8" Topsoil & Vegetation 7 8 14 2 8" - 3' Brown Sand 6 5 3 7 9 ' 17 4 3' - 6 Light Brown Sand with Shell 8 9 5 10 8 17 6 9 8 7 2 1 3 8 6' - 13' Gray Silt with Traces of Organics 2 3 9 10 2 10 2 2 11 A A A 12 A A 13 A A A 14 13' - 16' Gray Sand with Shell A A 15 7 9 17 16 8 10 17 A A A 18 16- 21' Bluish Gray Clay A A 19 A A A 20 A A 21 12 11 25 22 21' - 25' Bluish Gray Sand with Shell 14 15 23 A A A 24 A A 25 A A 26 27 28 29 30 Water Level: 3'6" Below Land Surface A = Auger Phone: 954-784.2941 E-Fax: 954-784-7875 .anganeeren�, admln@fed-ong.com _ .. o www.fdd.eng.com OOesp.ii �Binge c.. SPT Test Boring Report Client: Tammie Cox Project: Proposed Residence and Pool Address: 123 Queen Frederika Court Fort Pierce, FL 34949 Date of Test: February 4, 201.9 Hole No.: B-2 Location: See Attached Drawing Depth (FT) Sol] Descriptions Hammer Blows "N" 1 0" - 6" Topsoil & Vegetation 7 9 17 2 6" - 3' Brown Sand 8 9 3 8 7 16 4 3' - 6' Light Gray Sand with Shell _ 9 10 5 8 9 16 6 7 9 7 2 1 3 8 6' - 11' Gray Silt with Traces of Organics 2 0 9 1 2 3 10 1 I 11 A A A 12 1 V - 15' Gray Sand with Shell A ,A 13 A A A 14 A A 15 10 12 20 16 15'-20' BlulshGrayClay 8 8 17 A A A 18 A A 19 A A A 20 A A 21 14 15 31 22 16 15 23' _ A A A 24 20'— 30' Bluish Gray Sand with Shell A A 25 A A A 26 A A 27 16 15 29 28 14 15 29 A A A 30 I A A Water Level: 3'8" Below Land Surface A = Auger Phone: 954-784 2941 E-Fax: 954-784.7875 ®nghmeering admin@fed-eng.com www.fed-ang.com ®DesUng, Inc SPT Test Boring Report Client: Taounie Cox Project: Proposed Residence and Pool Address: 123 Queen Frederika Court Fort Pierce, FL 34949 Date of Test: February 4, 2019 Hole No.: B-3 Location: See Attacked Drawing Depth (FT Soil Descriptions Hammer Blows 'IN" 0" - 6" Topsoil & Vegetation 7 9 19 2, 6" - 3'6" Brown Sand 10 9 3 8 9 19 4 3'6" - 6' Light Gray Sand with Shell 10 8 S 11 7 16 6 9 8 7 2 1 1 6'- 12' Gray Silt with Traces of Organics 1 2 9 1 10 1 1 11 A A A 12 12'- 15' Gray Sand with Shell A A13 A A A 14 15 14 12 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Water Level: 3'8" Below LandSurfce A = Auger Oed@f ag Phone:954-784.2941 E-Fax: 954-784.7875 On9ineee'eng admin@fed-eng.com www.fed ong.corn ®Oestarog; Once. Report of Organic Content ASTM-D 2974 Date: Monday, February 4, 2019 Tammie Cox 123 Queen Frederika Court Fort Pierce, FL34949 Attn.: Jordan Kane RE: Geotechnical Services Proposed Residence and Pool 123 Queen Frederika Court Fort Pierce, FL 34949 Results of Test Sampled by: Sample Location: Material Description: Job Oider Nwnber Reported To: Client I s• t-lj e 4 - % Sample Looahon arld.Deptli-- «-.+ - - - Orgatiic Content Percentage%» —µ- - BI 6' -13' 39% B2 6' - 1 l' 1.8% B3 6' -12' B4 N/A N/A B5. N/A N/A Tested By: SJ Checked By: KL .e `: "„: 33701NE:51h Avenue I Oakland Park, Florida 33334w. v lhk • IAM ® T :Ounh © ������ Phone: 954-784-2941 E-Fax: 954.784-7875 eriginoeiring admin@fed-eng.com www.fed-eng.com No. 200 Wash Sieve Analysis Date: Monday, February 4, 2019 Tammie Cox 123 Queen Frederika Court Fort Pierce, FL 34949 Aun.: Jordan Kane RE: Geotechnical Services Proposed Residence and Pool 123 Queen Frederika Court Fort Pierce, FL 34949 Results of Test Sampled by: b Sample Location: E Material Description: Starting Sieve Weight B-1; Starting Sieve Weight B-2: Job Order Number 19SBO60 Sample Date: Sample Number: B-1 & B-2 Bonng,#, Sreve Sieze Cumulative Weight Retained (g) '.Comulatrve,o Passing': Gti mulattve.%" <i Retained . , B-1 #200 (0.075 mm) 102.57 39.9% 60.1% B-1 Pan - - B-2 #200 (0.075 mm) 132.14 19.20/, 80.8% B-2 Pan Tested By: Si Checked By: KL 3370 NE 5th Avenue I Oakland Park, -Florida 33334 CMEC • � �� • ®� _, 4 comet _r ';•ry X • i�.� u.•. ' ationae, Sid.•. 4 T1N•w Site Loc //}Sage Irf v 2018 Google c r Site Loc //}Sage Irf v 2018 Google c r C� Client: Tammie Cox Test: Subsoil Investigation (site map is not to scale) ® ri edereaal Q ngineeng & esting,Ine. Soil Boring Location Map 3370 NE 511i Project: Proposed Residence and Pool Project Address: 123 Queen Frederika Court Fort Pierce, FL 34949 t;Q I d ederal ©ngineering Resting, Inc. Soil Classifications Correlation of Penetration Resistance with Relative Density and Consistency Sands .. Dynamic Cone Penetrometer Penetrometer Resistance Standard Penetration Hannner Blows Relative Density 0 -10 0-4 Very Loose 11 -25 5 - 10 Loose 26 - 45 11 - 20 Firm 45 - 75 21 -30 Very Finn 76 -120 31 - 50 Dense >120 > 50 Very Dense Dynamic Cone Penetrometer Penetrometer Resistance Standard Penetration Flammer Blows Relative Density w 0-6 T, 0-2 Very Soft 7-15 3-5 Soft 16 - 30 6 -'10 Firm 31- 45 11 - 15 Stiff 46 - 90 16 - 30 Very Stiff 91 - 150 31 - 50 Hard Rock Hardness`Descnption ` Soft Rock core crumbles when handled Medium Can break core with your hands Moderately Hard Thin edges of rock core can be broken with fingers Hard Thin edges of rock core cannot be broken with fingers Very Hard Rock core rings when struck with a hammer., Sand Quantity Modifiers, , Very Slight Trace 0 = 2 % SlightTrace 2 - 5 % Trace Little Trace 10 -15 % Some 15 - 30 % ' With >30% Silt =`Clay Qnantity Moditiers Slightly Silty/Clayey 0 5% Silty /Clayey 5 - 30 % Very Silty / Clayey 30 - 50 % Particle Size Boulder > 12 in Cobble 3 -12 in Gravel _ 4.76 mm - 3 in Sand 0.074 mm - 4.76 mm Silt 0.005 nun - 0.074 nan. Clay < 0.0.05 mm A©ederal © glneering esting, Inc. Drilling & Sampling Procedures The soil borings were installed in accordance with Standard Penetration Tests procedures as set forth in ASTM D-1586. Representative samples were collected utilizing spilt -barrel techniques in accordance with the procedures set forth in "Penetration Tests and Spilt -Barrel Sampling of Soil in ASTM D-1586. The following field tests, measurements and laboratory analysis were performed/collected during the installation of each soil boring. Penetration Tests During the sampling procedures, Standard Penetration Tests were performed at five (5) foot intervals to obtain the standard penetration value (l) of the subsurface soil. The standard penetration value (N) is identified as the number of blows of a 140-pound hammer falling thirty (30) inches, required to advance the spilt -barrel sampler one (1) foot into the subsurface soil. The sampler was lower into the bottom of the previously cleaned drill hole and advanced by blows from the hammer. The number of blows was recorded for each of the three (3) successive increments of six (6) inches penetration. The "N" value is obtained by adding the second and third incremental numbers. Water Level Measurements Water Level depths were obtained during the test boring operations. In relatively pervious soils, such as sandy soils, the indicated depths are usually reliable groundwater levels. Seasonal variations, tidal conditions, temperature, land -use and recent rainfall conditions may influence the depths to groundwater levels. Soil Properties / Classification All samples collected were classified in accordance with the Unified Soil Classification System criteria to determined soil material properties and compared with published literature of the USDA Soil Conservation Survey. Ground Surface Elevations Ground surface elevations have not been provided for the proposed boring locations. Therefore, all references to depth of the various strata and materials encountered were from existing grade at the time of the drilling operations. Limitations of Liability Warranty We warrant that the services performed by Federal Engineering and Testing, Inc. (F.E.T.) are conducted in a manner consistent with the level of skill and care ordinarily exercised by members of the profession currently practicing under similar conditions. No other warranties, expressed or implied, are made. While the services of F.E.T. are an integral and valuable part of the design and construction process, we do not warrant, guarantee, or insure the quality or completeness of services or satisfactory performance provided by other members of the construction pmcess and/or the construction plans and specifications which we have not prepared, nor the ultimate performance of building site materials. As mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Reports are not intended for 3rd party use. Subsurface Exploration Subsurface exploration is normally accomplished by test borings. The soil boring log includes sampling information, description of the materials recovered, approximate depths of boundaries between soil and rock strata and groundwater data. The log represents conditions specifically at the location and time the boring was made. The boundaries between different soil strata are indicated at specific depths; however, these depths are in fact approximate and dependent upon the frequency of sampling. The transitions between soil stratum are often gradual. Water level readings are made at the time the boring was performed and can change with time, precipitation, canal levels, local well drawdown, and other factors. Regardless of the thoroughness of a Geotwhnical exploration there is always a possibility That conditions may be different from those of the test locations; therefore F.E.T. does not guarantee any subsoil condition surrounding the bore lest holes. For a more accurate portrayal of subsurface conditions, the site contractor should perform tests pits. If different conditions am encountered, F.E.T. shall be notified to review the findings and make any recommendations as needed. Laboratory and Field Tests Tests are performed in accordance with specific ASTM Standards unless otherwise indicated. All criteria included in a given ASTM Standard are not always required and performed. Each test report indicates the measurements and determinations actually made. Ownership of Tests /Reports All lest results and/or reports prepared by F.E.T. pursuant to this agreement and/or Addendum(s) thereto, shall remain the property of F.E.T. until all monies due and owing to F.E.T. under this Agreement and/or Addendum(s) thereto, are paid in full. Analysis and Recommendations The Geotechnical report is prepared primarily to aid in the design of site work and structural foundations. Although the information in the report is expected to be sufficient for these purposes, it is not intended to determine the cost of construction or to stand alone as construction specifications. Anederal gineering elating, Inc. Analysis and Recommendations cant In accepting this report the client understands that all data from the will boring is intended for foundation analysis only and is not to be used for excavating, backfilling or pricing estimates. In accepting this report the client understands that all data front the soil boring is intended for foundation analysis only and is not to be used for excavating, backfilling or pricing estimates. The site contractor must familiarize themselves with the job site conditions. Soil boring(s) on unmarked vacant pmperty, or existing structure(s) to be demolished is considered preliminary with further boring(s) to be performed after proposed building pad is staked out. Report recommendations are based primarily on data from lest borings made at the locations shown on the test boring reports. Soil variations may exist between borings and may not become evident until construction. If variations are then noted, F.E.T. must be contacted so that field conditions can be examined and recommendations revised if necessary. The Geotechnical report states our understanding as to the location, dimensions, and structural features proposed of the site. Any significant changes in the nature, design, or location of the site improvements must be communicated to F.E.T. so that the Geotechnical analysis, conclusions, and recommendations can be appropriately adjusted. Construction Observations Construction observation and testing is an important element of Geotechnical services: The Geotechnical Engineer's Field Representative (Field Rep.) is the '.owner's representative' observing the work of the contractor, performing tests, and reporting data from such tests and observations. The Geotechnical Engineer's Field Representative does not direct the contractor's construction means, methods, operations, or personnel. The Field Rep. does not interfere with the relationship between the owner and the contractor, and except as an observer, does not become a substitute owner on site. The Field Rep. is only collecting data for our Engineer to review. The Field Rep. is responsible for his/her safety only, but has no responsibility for the safety of other personnel and/or the general public at the site. If the Field Rep. does not feel that the site is offering a safe environment for him/her, the Field Rep. will stop his/her observation/ testing until he/she deems llte site is safe. The Field Rep. is an important member of a team whose responsibility is to observe the test and work being done and report to the client whether that work is being carried out in general conformance with the plans and specifications. Limitations of Report Federal Engineering & Testing, Inc. shall have an liability, in contract, tort or otherwise, for any inaccuracy, defect, or omission in interpreting this report and shall not in any event have any liability for lost profits or any other indirect, special, incidental, consequential, exemplary or punitive damages. In the event of future conflict between owners and contractors the following applies: F.E.T.(s) legal and/or company representation and preparation for representation fees will be billed on an hourly rate, i.e. deposition, expert witness, etc. F.E.T. has no obligation to amend its conclusions or recommendations after the date of this report. Any alterations or changes in the location of the project should be brought to our attention at the earliest convenience for review and applicability of this report. ©edera8 Phone: 064.784.2041 E-Fax:',954-7847875 Ag g, ineee�eng admin@fed-eng.com www.fe`d-ong.com estin Inc. Partial List of Services Geotechnical Enaineerina Services Soil I Aggregate Tests Field Inspection Services Asphalt Services Soil Borings Fill & Quality Control Inspections Backscatter Density Tests Density Compaction Tests Demucking Inspections Extractions & Gradations Grain Size Analysis Building Inspections Marshall Limits Moisture Contents Pile Driving Inspections Bulk Specific Gravity Soil,Classfications Pile Load Tests Cores for Thickness Determination Limerock Bearing Ratios $feel Inspection Asphalt Pavement Monitoring Florida Bearing Values Threshold Inspection Asphalt Assessment Specific Gravity Bolt inspection Carbonate Analysis Weld Inspection Concrete Tests Hydraulic Conductivity Vibration.Monitoring Concrete Strength Testing Organic Contents Slump Tests L.A. Abrasion Geotechnical Engineering Windsor Probe Testing Schmidt Hammer Testin FOOT Inspections QC Management Foundaton Engineering Foundation Design & Recommendation . 9 Core Testing Earthwork Inspections p Subsoil Investigation Pile Load Calculations AtrConlent Concrete Unit Weight QC Concrete Inspections QC Asphalt Inspections Piling Installation Monitoring Flexual Strength Testing Environmental Engineering Services Phase I Site Assessments Phase II Site Assessments Lead Base Paint Surveys Site Inspections Phase I Follow up on Contaminated Sites Report and Analysis Research of Properly Records Installation of Monitoring Wells Air Monitoring SoifBorings Soil and. GroundWaterAnalysis Roof Testing & Inspection Services TAS 105 Field Fastener Withdraw_ al Test TAS 106 Tile Uplift Test TAS 124 Bell Chamber I Bonded Pull Test TAS 126 Moisture Survey Windload Calculation Drainage Calculations Lightweight Concrete placement Inspection Roof Assessment / Evaluation Cap Sheet Inspection Fastener Spacing Inspection. 711e1 Shingle/ Standing Seam Inspection Base Sheet Instellation Inspection