HomeMy WebLinkAboutGoodman Airconditioning & Heating Submittal Data Sheet... Nr Conditioning& eeadng Submittal Data Sheet 16.0 SEER, Air Conditioner System,3.0 Ton, Outdoor Unit-GSX160371A• Submitted By: Goodman/Amana Unitary Test System Submitted To: WA Tags : AHRI 204295313 Products [GSX160371A• , ASPT35B14A•] , SEER 15.0. EER 12.5 STANDARD FEATURES: High -efficiency compressor Single -speed PSC condenser fan motor Factory -installed filter drier Fully charged for fifteen feet of tubing length Contactor with lug connection AHRI Certified - ETL Listed Ground lug connection Copper tube & enhanced aluminum fin coil CABINET FEATURES: • Heavy -gauge galvanized steel cabinet and louvered coil guards • Service valves with sweat connections and easy -access gauge ports • Engineered sound control top design • Baked -on powder -paint finish with 500-hour salt -spray approval • Single -panel access to controls with space for field -installed accessories • Service port and controls are accessible while unit is operating • Compact footprint • Rust -resistant screws • When property anchored, meets the 2017 Florida Building Code unit integrity requirements for hurricane -type winds (Anchor bracket kits available.) `1 m BB. L S=p At Goodman, gineemeve in American in toe U.S.A. Units am BBB f6 3 9 designed, engineered and assembled in the U.5.0. \_ 0;/ www.goodmanmfg.com Air Conditioning a Heating Submittal Data Sheet 15.0 SEER, Air Conditioner Systeni Ton, Outdoor Unit-GSX160371A' Submitted By: Goodman/Amana Unitary Test System Submitted To: WA Tags : AHRI 204295313 Products [GSX160371A' , ASPT35B14A•] , SEER 15.0 , EER 12.5 PERFORMANCESYSTEM Outdoor Unit Model No.: GSX160371A' Description : 15.0 SEER, Air Conditioner System, 3.0 Ton Outdoor Indoor Unit Model No.: ASPT35B14A' System TXV/PISTON : Factory Rated Cooling Conditions: Outdoor (°F DB/WB):95/75 Rated Heating Conditions: Outdoor ('F DBIWB):N/AIN/A Indoor ff DB/WB):80167 Indoor ff DB/WB):N/A/N/A Rated Cooling Capacity (Btu/hr): 34600 OD Rated Heating Capacity (Btu/hr) N/A EER: 12.5 Heating COP: NIA SEER: 15.0 AFUE: N/A OUTDOOR 1 Power Supply(V/Hz/Ph): 2081230/60/1 Compressor Type: Scroll Min. Circuit Amps MCA (A): 20.2 Compressor Stages: Single Stage Max Overcurrent Protection (MOP) (A): 35 Suction Valve Connection Size (in): 7/8 Compressor Rated Load Amps: 15A Liquid Valve Connection Size (in): 3/8 Refrigerant Type: R-410A Sound Power(High/Med/Low) (dBA): 73 /-1 NIA Holding Refrigerant Charge (oz): 93 Cooling Operation Range ff DB): 55 -125 Additional Charge (ozlft): 0.60 Heating Operation Range (°F DB): N/A Pre -charge Piping (Length) (ft): 15 Net Weight (lb): 182 Dimensions (HxWxD) (in): 36-114 x 35-3/4 x 35-314 Gross Weight (lb): 225 'Max. Pipe Length (Vertical) (ft): 50 'Max. Pipe Length (Total) (ft): 80 'Refer to Long Line Set Applicah'on TP-107 (orlines gmaterthan 80 R. or vertical elevation changes more than 50 R. forstngle stage equipment and 25 B. for2stage equipment At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.S.A. 0 www.Boodmanmfg.com Air Condilloning a eeanng Submittal Data Sheet 15.0 SEER, Air Conditioner System,3.0 Ton, Outdoor Unit-GSX160371A' Submitted By: Goodman/Amana Unitary Test System Submitted To: WA Tags : AHRI 204295313 Products [GSX160371A•, ASPT35B14A'] , SEER 15.0. EER 12.5 At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.SA www.goodmanmfg.com A, Ondidoning& Heating Submittal Data Sheet 15.0 SEER, Air Conditioner System,3.0 Ton, Outdoor Unit-GSX160371A• Submitted By: Goodman/Amapa Unitary Test System Submitted To: N/A Tags : AHRI 204295313 Products [GSX160371A• , ASPT35B74A'],, SEER 15.0 , EER 12.5 STANDARD FEATURES: • Internal factory -installed thermal expansion valves for cooling and heat pump applications • Direct drive, multi -speed ECM blower motor • All -aluminum evaporator coil • Coil mounting track for quick repositioning • Optimized for use with R-410A refrigerant • Cabinet air leakage less than 2.0% at 1.0 inch H2O when tested inaccordance with ASHRAE standard 193 • Cabinet air leakage less than 1.4% at 0.5 inch H2O when tested in accordance with ASHRAE standard 193 • 3 kW— 25 kW electric heater kits • AHRI certified • ETL listed CABINET FEATURES: Rigid SmartFrame cabinet Horizontal or vertical configuration capabilities • 21" depth for easier attic access • DecaBDE-free thermoplastic drain pan with secondary drain connections • Screw -less sides and back helps to reduce, condensation when installed in humid locations • Foil -faced insulation covers the internal casing to reduce cabinet condensation • Galvanized, leather grain -embossed finish • Glue -less cabinet insulation retention Tool -less filter access At Goodman. we believe In American dependability. Units are designed, engineered and assembled in the U.S.A. www.goodmanmfg.com NrWndidoningaeeating Submittal Data Sheet 15.0 SEER, Air Conditioner System,3.0 Ton, Outdoor Unit-GSX160371A` Submitted By: Goodman/Amana Unitary Test System Submitted To: N/A Tags : AHRI 204295313 Products [GSX160371A• , ASPT35B14X] , SEER 15.0 , EER 12.5 INDOOR AIR HANDLER UNIT DETAILS: ASPT351314 Power Supply (V/Hz/Ph): 208124016011 Suction Connection Size (in): 3/4 Min. Circuit Amps MCA (A): 5.6/5.6 Liquid Connection Size (in): 3/8 Max Overcurrent Protection (MOP) (A): 15 Condensate Connection (in): 314 Net Weight (to): 129 Dimensions (HxWxD) (in): 45 x 17-1/2 x 21 Gross Weight (lb): 109 The Electrical data shown, here in submittal is for Air Handler only with no heat added. When adding Heat Kit please refer to Heat Kit Spec Sheet for electrical requirements At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.S.A www.goodmanmfg.com NrCanditioning S. heading Submittal Data Sheet MID SEER, Air Conditioner System,3.0 Ton, Outdoor Unit-GSX160371A' Submitted By: Goodman/Amana Unitary Test System Submitted To: WA Tags : AHRI 204295313 Products [GSX160371X , ASPT35B14A'] , SEER 15.0. EER 12.5 3.08• (r.83 an) 1A5• (3.58.) 21 T 921'— — 0) Q C��.� j 293' It B.1 an) ar i cm) paean) 5a p3.3 an) C 3.1' 11.3' - p.9 on(28.70 an) GRAM PORT DETAIL (1A0 cm) (1.GO an) (ae i _ PLASTIC\ ( SPEAKER q (a.ean) LOGO LOCATION l (53fan) SUCTION TUBE A LIQUID LINE, ° G — _ --_ TUBE-- SEE GRAIN PORT DETAIL,� `—' p E H F 1 --1.73' 1'+ 19.5'(49.5an) - L as (4.39.) INLET (4.39 Un) (251.) INLET UA0em) (FRONT VIEW) (RIGHT SIDE VIEW) w I At en we ineereda dAmerican dependability. U. iA- Units are B8. MMM!H d designed, engineered and assembled in the U.S.A www.goodmanmfg.mm