RE: Job 81186
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
A-1 Roof Trusses
4451 St Lucie Blvd
Site Information: Fort Pierce, FL 34946
Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE
Lot/Block: 118 Model: BERMUDA 1674
Address: 308 PALM BREEZE DR, FORT PIERCE Subdivision:
City: County: St Lucie State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City:
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading
Conditions):
Design Code: FBC 2017 RES / TPI 2014 Design Program: Alpine Engineered Products
Wind Code: ASCE 7-10 Wind Speed: 160
Roof Load: 37.0 psf Floor Load: 0.0 psf
This package includes 39 individual, dated Truss Design Drawings and 16 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules.
No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
Date
1
2655
A01 —
6/9/20
13
2539
A13
6/9/20
25
2523
_
CJ3A
6/9/20
2
3404
A02
6/9/20
14
2514
1301
6/9/20
26
2524
CJ5
6/9/20
3
3401
A03
6/9/20
1 15
2515
B02
6/9/20
1 27
2535
HJ3
6/9/20
4
2583
A04
6/9/20
16
2516
B03
6/9/20
28
2536
HJ7
6/9/20
5
2576
A05
6/9/20
17
2517
B04
6/9/20
29
2537
HJ7S
6/9/20
6
2507
A06
6/9/20
18
2666
B05
6/9/20
30
2538
HJB1
619120
7
2572
A07
6/9/20
19
2518
B06
6/9/20
31
2525
J3
6l9/20
8
2569
A08
6/9/20
20
12541
C01
6/9/20
1 32
12526
J34
6/9/20
9
2555
A09
6/9/20
21
2519
CO2
6/9120
33
2527
J3GE
6/9/20
10
2511
A10
6/9/20
22
2520
CA
6/9/20
34
2528
J7
6/9/20
11
2470
All
6/9/20
23
2521
CJ1A
6/9/20
35
2529
J7C
6/9/20
12
12513 1
Al2
6/9/20
24
2522
CJ3
619/20
36
2530
VM02
6l9/20
its uubbundwuKjks roccnccundvcuccnNicLaieuuyrvNnrcrayuiCCicunwucs,IrIV.UIIUGIirIyunmussys,ltu.
Truss Design Engineer's Name: Rama Pranav Kr[stam
My license renewal date for the state of Florida is February 28,2021.
NOTE:The seal on these drawings indicate acceptance of professional engineering
responsibility solely forthe truss components shown.
The suitability and use of components for any particular building is the responsibility of the building
designer, perANSUTPI-1 Sec. 2.
The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction
documents (also referred to attimes as'Structural Engineering Documents') provided bythe Building
Designer indicating the nature and character of the work
The design criteria therein have been transferred to Rama Pranav Kristam PE by [Al Roof Trusses or
specific location]. These TDDs (also referred to at times as'Structural Delegated'
Engineering Documents') are specialty structural component designs and may be part of the prvject's
deferred orphaned submittals. As a Truss Design Engineer (i.e., Specialty
Engineer), the seal here and on the TDD represents an acceptance of professional engineering
r+esponsibilityforthe design of the single Truss depicted on the TDD only. The Building Designer is
responsible forand shall coordinate and review the TDDs for
compatibility with theirwritten engineering requirements. Please review all TDDs and all related notes.
Page 1 of 2
OF G _
)NAX,. v
111111tt111
Rama Pranav Kristam, RE
4451 St Lucie Blvd. Suite 201
Fort Pierce, FL 34946
Rama Pranav Kristen P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
'' Fort Pierce, FL 34946
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
A-1 ROOF These truss designs rely on lumber values established by others.
TRUSSES
A FLORIDA CORPORATION
RE: Job WRMSBM167482
No.
Seq #
Truss Name
Date
37
2531
VM04
6/9/20
38
2532
VM05
6/9/20
39
2533
VM06
6/9/20
40
STDL01
STD. DETAIL
6/9/20
41
STDL02
STD. DETAIL
6/9/20
42
STDL03
STD. DETAIL
6/9/20
43
STDL04
STD. DETAIL
6/9/20
44
STDL05
STD. DETAIL
6/9/20
45
STDL06
STD. DETAIL
6/9/20
46
STDL07
STD. DETAIL
6l9/20
47
STDL08
STD. DETAIL
6/9120
48
STDL09
STD. DETAIL
6/9/20
49
STDL10
STD. DETAIL
6/9/20
50
STDL11
STD. DETAIL
6/9/20
51
STDL12
STD. DETAIL
6/9/20
52
STDL13
STD. DETAIL
6/9/20
53
STDL14
STD. DETAIL `
619/20
54
STDL15
STD. DETAIL
6/9/20
55
STDL16
STD. DETAIL
6/9/20
Rama Pranav Kristam, P.E.
# 88906
Page 2 of 2 4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
WRMSBM1674B2 ( A01
1ivaa 1yp.
GABL
Wry I rry 1 vu1ua14UZu
2655
T
JT Tt
it T
Bap a3p
i 6�i i Bpi
r
1'-6'5'6 i 4 296'4 P9'11'14 �I
I�-1Ta' 1 294'
SEAT PVItE REQ. SEAT PATE REp, SEAT Pi-E REO
i- 18'3'13 k M-3 -i
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing:, 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwali: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP M-30 :T3, T4, T6 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3 :W7, W9 2x4 SP #2:
2'2.12 198'14 114+(
2'+�
51p 51p 51N Stp
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Bracing
(a) Continuous lateral restraint equally spaced on member
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 plf at -3.97 to 62 plf at 8.68
TC: From 31 plf at 8.68 to 31 plf at 15.03
TC: From 62 plf at 15.03 to 62 pif at 36.70
BC: From 14 pif at -2.64 to 14 pif at 8.40
BC: From 7 pif at 8.40 to 7 pif at 15.62
BC: From 14 plf at 15.62 to 14 pIf at 35.36
TC: 83lb Conc. Load at 8.64,10.64,12.64,14.64
BC: 51 lb Conc. Load at 8.64,10.64,12.64,14.64
Plating Notes
All plates are 1.5X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 0 -2.64 26.02
BC 97 0.20 8.25
BC 36 8.25 15.67
BC 75 15.77 35.22
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.173 E 999 360
k,q_-RT(CL): 0.367 E 602 240
HORZ(LL): 0.078 F - -
HORZ(TL): 0.165 F
Creep Factor: 2.0
Max TC CSI: 0.890
Max BC CSI: 0.996
Max Web CSI: 0.840
Wgt: 312.2 Ibs
VIEW Ver: 19.01.00A.0618.15
Wind
Wind loads and reactions based on MWFRS.
Bearing Block(s)
Brg blocks:0.131"x3", min. nails
brg x-loc #blocks length/blk #nails/blk wall plate
2 18.000' 1 191. 13 Rigid Surface
Brg block to be same size and species as chord.
Refer to drawing CNNAILSP1014 for more information.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to
exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- !Rh /Rw /U /RL
AS 911 /- /- /- /442 /13
Y 5506 /- /- /- /1448 /-
S 1060 /- /- A /374 /-
Wind reactions based on MWFRS
AS Brg Width = 7.6 Min Req = 1.5
Y Brg Width = 7.6 Min Req = -
S Brg Width = 7.6 Min Req = 1.5
Bearings AS, Y, & S are a rigid surface.
Bearings AS, Y, & S require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C
2829 -1053
J - K
1974
- 665
C - D
1507 - 2088
K - L
2030
- 667
A - B
75 - 39
L - M
2025
- 670
B -AS
2047 - 2172
M - N
2021
- 673
D - E
1754 - 592
N - O
2074
- 685
E - F
1785 - 600
O - P
1941
- 658
F - G
1786 - 599
P - Q
1988
- 670
G-H
1831 -610
Q-R
315
-527
H - 1
1813 -601
R-S
357
-1117
1-1
1816 -607
S-T
75
-39
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
C -AC 921 - 283 Y - W 52 -190
AC -AB 129 - 37 W - V 368 - 274
AA- Z 280 - 33 V - U 368 - 274
Z - X 1165 - 3283 U - S 841 -186
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
D -AC
111 -144
J -AL
617 -1862
D -AD
1036 - 3161
AL- X
1256 -4307
D -AA
764 -184
AL -AN
1631 - 488
AC -AA
804 - 249
AM- K
83 - 309
AD-AE
1039 - 3172
X - Y
1455 - 5489
AA -AB
62 0
X -AP
1162 - 3576
AA-AH
1554 -496
X - W
251 - 351
AE-AA
220 - 611
AN -AO
1633 - 489
AE-AF
1050 -3230
AO- M
136 -417
AF-AG
1054 -3243
AO -AP
1641 -490
AG-AH
1056 -3250
AP- W
320 -128
AH- Z
418 -1377
AP-AQ
866 -1736
AH-AI
627 -1593
W - Q
129 -466
Z -AL
3720 -1118
AQ-AR
862 -1723
-WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite
lvlv te 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, 349te
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
r:nnvnnht 02nta A-1 Rnnf Tn.--- Renrndnntinn of thin dmimant. in anv form. is nrohihited withnut thn written n,. i6Rinn of A-1 Rnnf TniaveR
yl
A01 I GABL 11 11 VV
2655
AI-AJ 629 -1601 AR- Q . 859 -1715
AJ-AK 629 -1601 U - Q 614 - 227
AK -AL 629 -1603 U - R 294 - 711
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp. Gables Tens. Comp
E -AD 107 -295 1 -AK 38 -158
F -AF 150 - 446 AN- L 54 -187
G -AG 104 - 353 AQ- N 177 - 538
H -Al 147 -511 AR- P 69 -201
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedri
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Mstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
1l 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvdnht 0 2016 A-1 Roof Tm. s%c - Ranrodertion of this dnralmentin anv formis nrohihitad withmil tha wntten narmic inn of A-1 Roof T—Al
JUU
WRMSBM 1674B2
. yN.
A02 I COMN
1,y I r1y
3404
E-- 5.7.9 324'7 '
i 17'8' 20W
SEAT PLATE REQ.
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
TOLL: 20.00
Wind Sid: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
BOLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
EXP: B Kzt: NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
NCBCLL: 10.00
TCDL 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
TO 0
-2.64 3.00
BC 75
0.20 35.22
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
19'7'6
38,
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.069 C 999 36
VERT(CL): 0.151 C 999 24
HORZ(LL): 0.030 C -
HORZ(TL): 0.065 C
Creep Factor: 2.0
Max TO CSI: 0.743
Max BC CSI: 0.898
Max Web CSI: 0.912
Wgt: 222.6 Ibs
VIEW Ver: 19.01.00A.0618.16
SEAT PLATE REQ.
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
S 445 /- /-
/209 /205
/332
P 2181 /- /-
/1179 1782
/-
K 627 /- i-
/485 /220
/-
Wind reactions based on
MWFRS
S Brg Width = 7.6
Min Req = 1.5
P Brg Width = 3.5
Min Req = 2.6
K Brg Width = 7.6
Min Req = 1.5
Bearings S, P, & K are a rigid surface.
Bearings S & K require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
B - C 1345 - 595
F - G 1006
- 217
C - D 712 -1082
G - H 1051
- 226
A- B 35 0
H- 1 1137
- 253
B - S 968 -1159
I - J 377
- 396
D - E 203 -126
J - K 406
- 750
E-F 245 -110
K-L 35
0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
C-R 486 -231 P-N 12 -1
R - Q 485 - 230 N - M 12 -1
Q - 0 274 -178 M - K 612 - 286
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
D-R
96 0
O-H
262
-314
D - Q
274 - 578
0-1
484
- 836
Q - F
408 - 33
0 - M
255
- 499
F - 0
397 - 771
I - M
601
-188
G - O
356 -1094
M - J
326
- 443
0 - P
843 -2134
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Krislam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
f:nnvnnht t7201A A-1 Rnnf TniceP_<— Rnnrnrindinn of thin d—rhent in nnv formis nmhihited without the written nerniasinn of A-1 Finer Tnu—
JVY
WRMSBM 1674B2
I IUJJ IIUJJ IYPU
A03 ( COMN
1 y 1y I Uu1UZ),4U4V
1
3401
17'8' i20'4"
SEAT PLATE REQ. SEAT PLATE REQ.
18'5"14
F4-} 101014 1P 7,4"4
r 38'
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 it
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 18.53
BC 120 18.53 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
19'6"2
19'T6
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/# Gravity Non -Gravity
VERT(LL): 0.021 S
999 360 Loc R+ / R- / Rh / Rw / U / RL
VERT(CL): 0.046 S
999 240 B 643 /- i- /394 /155 /313
HORZ(LL): 0.010 M
- - P 1846 1- /- /930 /430 /-
HORZ(TL): 0.018 M
- - K 683 /- /- /488 /168 /-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.665
B Brg Width = 7.6 Min Req = 1.5
Max BC CSI: 0.942
P Brg Width = 3.5 Min Req = 2.2
Max Web CSI: 0.852
K Brg Width = 7.6 Min Req = 1.5
Bearings B, P, & K are a rigid surface.
Wgt: 226.8 Ibs
Bearings B & K require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.16 Chords Tens.Comp. Chords Tens. Comp.
A-B 35 0 G-H 651 -111
B - C 294 - 834 H - 1 271 - 427
C - D 178 -508 I - J 256 - 518
D - E 187 -426 J - K 379 - 870
E- F 572 - 54 K- L 35 0
F-G 583 -14
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-T 682 -248 P-N 11 -3
T-S 4 -16 N-M 11 -3
S-Q 0 0 M-K 719 -183
R - O 426 - 238
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - T
103 - 68
O - P
749 -1798
C - R
232 - 337
O - G
240
- 295
T - R
694 - 241
O - H
459
- 751
R-S
73 0
O-M
232
-71
R - E
400 -41
H - M
508
-154
E - O
395 - 795
M - J
315
- 434
F - O
265 - 709
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TOD to be valid. As a Truss Design Engineering (Le, Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 209
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, Blvd,
349te Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1.
C;onvrinht n 2n16 A-1 Roof Tnracr_c - Rnnrortnnnno of this dminnentin anv formis nrohihitsd vvithend thn wrif ,n narmissinn of A-1 Roof Tnissos.
YVV
WRMSBM1674B2
I I.... I I V.D I Yp-
A04 COMN
1 y 1y �
I vu,uu,4u4
1
2583
i 17'8" - I- 20'4•
SEAT PLATE REQ. SEAT PLATE REQ.
18'5"14 19'6"2
�4• 18'4'10 197"6 1 4+
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2 34 2x4 SP M-30
Webs 2x4 SP #3
Code / Misc Criteria
Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 112 0.15 18.53
BC 75 18.53 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
38'
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.054 D 999 36
VERT(CL): 0.104 Q 999 24
HORZ(LL): 0.027 F - -
HORZ(TL): 0.051 F
Creep Factor: 2.0
Max TC CSI: 0.580
Max BC CSI: 0.980
Max Web CSI: 0.284
Wgt: 214.2 Ibs
VIEW Ver: 19.01.00A.0618.15
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- i Rh / Rw / U / RL
B 928 /- /-
/607 /297 /331
N 1281 /- /-
/666 /561 /-
1 903 /- /-
/563 /315 /-
Wind reactions based on
MWFRS
B Brg Width = 7.6
Min Req = 1.5
N Brg Width = 3.5
Min Req = 1.5
1 Brg Width = 7.6
Min Req = 1.5
Bearings B, N, & I are a
rigid surface.
Bearings B & I require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 35 0
F- G 226 - 381
B - C 485 -1442
G - H 430 -1014
C - D 426 -1191
H - 1 550 -1371
D- E 222 - 457
I- J 35 0
E - F 327 -443
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - Q 1229 - 374 N - L 18 - 3
Q - P 835 - 258 L - K 18 - 3
P - O 835 - 258 K - I 1169 - 326
O - M 404 -185
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - Q
248 - 310
M - F
340
- 520
Q - D
465 -110
M - G
405
- 655
D - O
398 - 686
M - K
707
- 44
E-O
436 -125
G-K
418
-98
M - N
658 -1229
K - H
325
- 431
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvdnht 0 2016 A-1 Ronf Tot—, - Renrodnntion of this dnmmontin anv form. is nmhihited vrilhnnt the wd fnn nnnniscion of A-1 Roof To—.,
JOID 1 FUSS I rU55 I YPV WLy My vufvafcvcv
WRMSBM1674B2 A05 I COMN 111 11 ( 2576
T
1 1
1 615111 31'6"5
SEAT PLATE REG. SEAT PLATE REG.
195'12 19-6"4
38'
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.081 C 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.172 C 999 240
W 442 /- !- l205 /162 /332
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.035 C - -
R 2178 /- !- /1185 1585 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.075 C
K 632 /- !- /490 /224 /-
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 4.2 psf
0.
Max TC CSI: 0.702
W Brg Width = 7.6 Min Req = 1.5
Load Duration: 1.25
BCDL: 4.2 psf
R Brg Width = 3.5 Min Req = 2.6
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
Max BC CSI: 0.996
K Brg Width = 7.6 Min Req = 1.5
C&C Dist a: 3.80 ft
Max Web CSI: 0.918
Bearings W, R, & K are a rigid surface.
Loc. from endwall: not in 9.00
Wgt: 235.2 Ibs
Bearings W & K require a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.15
Chords Tens.Comp. Chords Tens. Comp.
Lumber
B - C 1322 - 571 F - G 1034 - 231
Top chord 2x4 SP #2
C - D 764 -925 G - H 1116 -229
Bot chord 2x4 SP #2
A - B 35 0 H - I 503 - 268
Webs 2x4 SP #3
B - W 947 -1127 I - J 464 - 280
Bracing
D - E 270 -144 J - K 387 - 779
E - F 287 - 84 K - L 35 0
(a) Continuous lateral
restraint equally spaced on member.
Plating Notes
Maximum Bot Chord Forces Per Ply (Ibs)
All plates are 1.5X4 except as noted.
Chords Tens.Comp.
Chords
Tens. Comp.
C- V 353 -208
R- O
7
-18
Purlins
V - S 569 - 765
O - N
624
- 268
In lieu of structural panels or rigid ceiling use puriins
U - T 0 0
N - M
624
-268
to laterally brace chords as follows:
S - P 556 -722
M - K
626
-266
Chord Spacing(in oc) Start(ft) End(ft)
T - Q 14 -48
TC 0 -2.64 3.77
BC 66 0.20 15.89
BC 75 15.89 35.22
Maximum Web Forces
Per Ply (Ibs)
Apply purlins to any chords above or below fillers
Webs Tens.Comp.
Webs
Tens. Comp.
at 24" OC unless shown otherwise above.
D - V 267 -480
P - G
249
- 293
Wind
E - V 320 -379
P - H
492
-860
Wind loads based on MWFRS with additional C&C member design.
V - F 931 -462
P - O
246
-445
S-T 18 -8
H-O
501
-181
F - P 547 -1484
O - J
318
- 611
Q- R 829 - 2143
J- M
243
0
P - Q 830 - 2105
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI.1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lurie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
r:nnvdnht n 2016 A-1 Rnnf Tniave_v- Ranr A-Ainn of this dnraimentin anv form. ix nmhihiled withrnil tha writtnn nanniccion of A.1 Rnnf Tres
. uu uss i t uss I ype ury rry U01UWZUZU
WRMSBM1674B2 ( 'A'
06 I COMN 2 11
2507
SEAT PLATE RED.
1 T8" i 20'4"
III2X4 �4X10=3X6
38'
�-- 2'8"6 1- 137"10 — +2 0 8+ 197'8
Loading Criteria (pst)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2 :T1 2x8 SP 2400f-1.8E:
:T2 2x6 SP #2:
Bot chord 2x4 SP #2 :B1, B2 2x6 SP #2:
Webs 2x4 SP #3
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X4 except as noted.
(`*) 1 plate(s) require special positioning. Refer to scaled plate plot details for
special positioning requirements.
Tray Scab(s)
(2) 2x8x9-3-5 x SP 2400f-1.8E scabs at left end. Attach one scab to each outer face
of chord with: 0.131 "0", min. nails @ 8" oc, Plus additional nail clusters at: BRG.:
(4), heel: (6), 1st panel point: (2).
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.28 15.82
BC 100 15.82 35.16
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.212 O 999 36
VERT(CL): 0.397 O 999 24
HORZ(LL): 0.136 L - -
HORZ(TL): 0.255 L
Creep Factor: 2.0
Max TC CSI: 0.468
Max BC CSI: 0.996
Max Web CSI: 0.750
Wgt: 311.5 Ibs
VIEW Ver: 19.01.00A.0618.15
I
1
SEAT PLATE RED.
12
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1431 /- /- /810
/345 /290
J 1512 /- /- /899
/371 A
Wind reactions based on MWFRS
A Brg Width = 7.6 Min Req = 1.5
J Brg Width = 7.6 Min Req = 1.8
Bearings A & J are a rigid surface.
Bearings A & J require a seat plate.
Maximum Top Chord Forces Per
Ply (Ibs)
Chords Tens.Comp. Chords
Tens. Comp.
A - B 364 - 622 F - G
930 - 2163
B - C 1306 - 3262 G - H
924 -1963
C - D 1173 - 2813 H -1
922 - 2135
D - E 884 - 2005 I - J
1052 - 2663
E- F 990 - 2002 J- K
35 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - V
3166 -1078
R - O
2470
- 773
V - U
3156 -1075
Q - N
32
-11
U - T
3156 -1075
N - M
2302
- 827
T - R
2501 - 787
M - L
2302
- 827
S - P
32 -13
L - J
2304
- 827
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
V-C
76 -162
O-F
181
-108
C - T
336 - 764
O - G
201
-149
D - T
442 -135
O - N
1969
- 632
D- O
449 - 900
P- Q
83
0
S-R
43 -5
G-N
128
-441
E - O
1361 - 677
N - I
271
- 536
O-P
113 0
1 - L
217
0
-WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd,
d, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NQT the
Fort Pierce, 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C:onvdnht 201fi A-7 Ronf Tniasa_o — RrnrndnNinn of this domiment. in anv fnrtn. is nmhihited withnol the wnttvn nennizsinn of A-1 R-f Tntacac
.,uo uss Iluse IyPV Wry My u011.1z UZU
WRMSBM1674B2 (A07 I COMN 11 1
2572
F- 7'0'8 1 3011'S
16'4' 28'
eSX6 /SX8(R)
F G
SEAT PLATE REQ SEAT PLATE REQ.
18'5'12 196*4
r
I--1-1
19'7.8
38'
14-{
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl
L/# Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Sid: 2014
VERT(LL): 0.270 X 817
360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0,00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.527 X 418
240 AA 909 /- /- /544 /300 /313
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.113 D -
- T 1277 /- !- /654 /315 /-
Des Ld: 37.00
EXP: B Kzt: NA
Plate Type(s):
HORZ TL 0.225 D
( )
K 915 /- /- /574 /295 /-
Mean Height: 25.00 ft
WAVE, HS
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 4.2 psf
Max TC CSI: 0.824
AA Brg Width = 7.6 Min Req = 1.5
Load Duration: 1.25
BCDL: 4.2 sf
p
T Brg Width = 3.5 Min Req = 1.5
Spacing: 24.0 "
MWFRS Parallel Dist: hl2 to h
Max BC CSI: 0.977
K Brg Width = 7.6 Min Req = 1.5
C&C Dist a:-3.80 ft
Max Web CSI: 0.696
Bearings AA, T, & K are a rigid surface.
Loc. from endwall: not in 9.00
Wgt: 222.6 Ibs
Bearings AA & K require a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp.
Lumber
Top chord 2x4 SP #2 :T1,
T2 2x4 SP 2400f-2.OE:
B - C 3714 -1370 F - G 494 -447
Bot chord 2x4 SP #2 :63 2x4 SP M-30:
C - D 913 -1836 G - H 482 - 505
Webs 2x4 SP #3 06 2x4 SP #2:
A - B 35 0 H -1 581 - 725
B -AA 2715 - 2751 I - J 574 - 858
Bracing
D - E 408 -656 J - K 705 -1407
(a) Continuous lateral restraint equally spaced on member.
E - F 436 - 588 K - L 35 0
Plating Notes
(**) 1 plate(s) require special positioning. Refer to scaled plate plot details for
special positioning requirements.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 0 -2.64 4.41
TC 24 13.70 16.36
BC 91 0.20 16.22
BC 75 16.22 35.22
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
C - Z
1822 - 672
T - R
107
- 33
Z-Y
1821 -671
S-Q
110
-304
Y - W
1821 - 671
R - O
40
- 64
X-V
0 -1
O-N
1188
-456
W - U
447 -168
N - M
1188
- 456
U - P
670 - 223
M - K
1191
- 455
V-S
94 -216
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
D- Z
275 0
P- H
341
- 547
D - W
729 -1425
P - O
764
- 239
F - W
148 - 31
Q - R
639
-173
U - V
146 - 335
H - O
182
- 78
T- S
600 -1715
O - J
295
- 567
P- Q
410 - 839
J- M
225
0
P - G
116 - 302
**WARNING** Please thoroughly review the "A•1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engmeedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the content of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 201
d, Suite
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, 4451 St. Lucie Blvd,
349te
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1.
Cnnvdnht n 2016 A-1 Roof Tnissas - Ronmdnotinn of this r minienl. in anv fnno. is nrohihitad without tha vmll- r"+. hn inn of A-1 Roof Tni. S
auu 'A'
Ewa i tuao t yNc �(ty rry wfuaf<
WRMSBM1674B2 (A'08 I COMN 1 11
2569
30'10"2
a
i` 14'4' 17'
TT
15X8(R) T4 @H0710
F G H
SEAT PLATE REQ. SEAT PLATE REQ.
18'5'12 19V4
tit 19'7'8 14�
IX
38'
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2 :T4 2x6 SP #2
:T6 2x4 SP M-30:
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 1.5X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 0 -2.64 4.52
TC 24 11.70 18.36
BC 75 0.20 35.22
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/# Gravity Non -Gravity
VERT(LL): 0.141 U
999 360 Loc R+ / R- / Rh / Rw / U / RL
VERT(CL): 0.408 U
544 240 W 470 /- /- /244 /79 /267
HORZ(LL): 0.047 C
- - R 2088 /- /- /1146 /159 /-
HORZ(TL): 0.093 C
K 677 /- /- /523 /192 /-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.764
W Brg Width = 7.6 Min Req = 1.5
Max BC CSI: 0.972
R Brg Width = 3.5 Min Req = 2.5
Max Web CSI: 0.858
K Brg Width = 7.6 Min Req = 1.5
Bearings W, R, & K are a rigid surface.
Wgt: 228.9 Ibs
Bearings W & K require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp.
B - C 1465 - 370 F - G 993 - 229
C - D 488 - 766 G - H 993 - 227
A - B 35 0 H -1 600 - 226
B - W 1084 -1095 I - J 526 - 228
D - E 410 - 598 J - K 347 - 783
E- F 431 - 534 K- L 35 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
C-V
446 -69
R-O
0
-122
V - S
360 - 380
O - N
607
- 225
U- T
0 0
N- M
607
- 225
S - P
374 - 277
M - K
610
- 224
T-Q
0 -182
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
D - V
385 - 555
P - Q
835 - 2020
V - F
1050 -466
P - O
517 - 627
F - P
542 -1064
P - H
853 -1528
S - T
5 - 54
O - H
821 - 507
G - P
51 -104
O - J
433 - 807
Q- R
821 - 2087
J- M
327 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:nnvnnht (7 201e A-1 Ronf Tmsses - Renrndnrtion of this dnrument. in anv form, is nrnhihifed without the wdHnn oarmissinn of A-1 Rnnf Tmcses.
dvu uuaa rivao typ- Ty
, ry vwva,av�.,
WRMSBM1674B2 A09 I COMN 11 11 2555
12'4" 'l018"
31'1'7
15,
.6X6
F G
t H
12
6 i? 'L2X4(R 1%3X4
_o T %1.5X4(R)C
w 'a2X4(R) 8 4X6 m6X6 (a)
-�,-°id. 05X6 U T G
v A -3X4
1 L Q3 J63XK(A1)
113Y3 aqua a¢xe L
SEAT PLATE REQ. SEAT PLATE REQ.
18'5'12 19W4
16'4" 1978
38,
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
TCDL: 10.00
Speed: 160 mph
TPI Sid: 2014
VERT(LL): 0.097 C 999 361
BCLL- 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.195 C 999 241
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.042 C -
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.085 C
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2
NC13CLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Max TC CSI: 0. 890
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
Max BC CSI: 0.753
C&C Dist a:.3.80 ft
Max Web CSI: 0.455
Loc. from endwall: not in 9.00
Wgt: 215.6 Ibs
GCpi: 0.18
VIEW Ver: 19.01.00A.0618.15
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member
Plating Notes
All plates are 1.5X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 0 -2.64 4.18
TC 24 9.70 20.36
BC 75 0.20 35.22
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
V 469 !- /-
/245 /177
l256
Q 2103 /- !-
/1108 /566
!-
J 660 !- /-
/493 /213
!-
Wind reactions based on
MWFRS
V Brg Width = 7.6
Min Req = 1.5
Q Brg Width = 3.5
Min Req = 2.5
J Brg Width = 7.6
Min Req = 1.5
Bearings V, Q, & J are a rigid surface.
Bearings V & J require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
B - C 1466 - 491
F - G 1198
- 262
C-D 791 -876
G-H 519
-214
A-B 35 0
H - 1 457
-218
B - V 1109 -1161
I - J 359
- 795
D-E 294 -122
J-K 35
0
E - F 1201 - 263
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
C-U
371 -171
Q-N
11
-17
U - R
295 -193
N - M
627
- 234
T- S
0 0
M- L
627
- 234
R - O
284 -175
L - J
630
- 233
S-P
12 -17
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
D - U
393 - 567
O - P
863 - 2056
E - U
457 -78
O - N
312 -477
E - O
524 -1300
O - G
650 -1388
R- S
34 0
N- G
568 - 272
F - O
233 - 346
N - 1
394 - 708
P - Q
862 -2080
1- L
287 0
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" forth.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(`v6nht.)201e A-1 Rtu,f Tni -- Renrndnntion of this dornmont. in anv form. N nmhihitad without the written nemi-inn of A-1 Rnof Tnt
doo i Fuss IF uss 1 ype Qry Fry unfuafzuzu
WRMSBM1674B2 A10 HIPS 1 1 2511
T
1
j 10'4"
viF 5X8
SEAT PLATE RED.
18'5"12
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.80 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
18'4"8
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Bracing
(a) Continuous lateral restraint equally spaced on member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 10.33 25.00
BC 120 0.15 18.52
BC 75 18.52 37.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
14'8"
13'
1111.5X4
SEAT PLATE REQ.
19'6"4
19'7"8
38'
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.026 K 999 36,
VERT(CL): 0.052 K 999 241
HORZ(LL): 0.014 K -
HORZ(TL): 0.026 K -
Creep Factor: 2.0
Max TC CSI: 0.955
Max BC CSI: 0.814
Max Web CSI: 0.572
Wgt: 205.8 Ibs
VIEW Ver: 19.01.00A.0618.15
1'4�
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 699 /- /-
/447 /170 /203
O 1695 /- /-
/787 /414 !-
1 740 /- /-
/512 1181 /-
Wind reactions based on MWFRS
B Erg Width = 7.6
Min Req = 1.5
O Brg Width = 3.5
Min Req = 2.0
1 Big Width = 7.6
Min Req = 1.5
Bearings B, O, & I are a rigid surface.
Bearings B & I require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 35 0
F- G 244 - 386
B - C 415 - 924
G - H 229 - 459
C - D 301 - 603
H - I 403 -1006
D-E 416 -64
I-J 35 0
E -F 416 -63
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - Q 772 - 207 M - L 825 - 262
Q - P 487 -118 L - K 825 - 262
P - N 488 -118 K - I 828 - 262
O-M 3 -5
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C- Q
236 - 333
N- M
348
0
D - Q
430 -114
N - F
445
- 859
D - N
451 - 970
M - F
381
-154
E - N
278 - 505
M - H
318
- 575
N- O
760 -1657
H- K
229
- 7
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, Blvd,
349te Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
0onvnnht cn 201A A-1 Roof Tnrese_v - Renrnrinntion of thin do-ment in anv form. is nmhihited vrithnut the vrtitlen nenniscinn of A.1 Ronf Tninnee
moo t fuss t tubs i yNC Wty rwfwfcucu
WRMSBM1674B2 A11 I HIPS 11 11 ry I 2470
II
i- 874 i18W 11' -�
o 5X6 =3X6 =5X6
D E F G H
SEAT PLATE REQ. SEAT PLATE RED. SEAT PLATE REQ.
---- 13'3"1 24'8"3
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.79 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2 :T1 2x4 SP 2400f-2.OE
Bot chord 2x4 SP #2 :B4 2x4 SP 2400f-2.0E:
Webs 20 SP #3
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 3X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use puriins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 8.27 26.94
BC 75 0.00 37.79
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
37' 11 "4 I.1'4"
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): 0.042 L 999 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(CL): 0.080 L 999 240
R 473 /- /- /428 /159 /186
HORZ(LL): 0.012 L - -
P 1737 /- /- /971 /395 /-
HORZ(TL): 0.022 L
J 944 /- /- /602 /234 /-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.805
R Brg Width = 6.9 Min Req = 1.5
Max BC CSI: 0.493
P Brg Width = 7.6 Min Req = 2.0
J Brg Width = 7.6 Min Req = 1.5
Max Web CSI: 0.924
Bearings R, P, & J are a rigid surface.
Wgt: 250.6 Ibs
Bearings R, P, & J require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01AOAA618.15
Chords Tens.Comp. Chords Tens. Comp.
A- B 37 0 F- G 488 - 200
B - C 262 -491 G - H 396 - 602
C - D 206 -197 H - I 507 -1080
D - E 174 -117 I - J 637 -1440
E- F 488 - 200 J- K 35 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
R - Q 636 - 706 N - M 900 -180
Q - P 636 - 706 M - L 900 -180
P - O 370 -218 L - J 1231 -449
O-N 370 -218
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
B - R
363 - 405
T - U
335
- 267
B - S
379 -146
E - U
589
- 784
R - S
694 -437
P - U
951
-1567
C - T
289 - 307
U - G
620
-1215
S - Q
344 -484
U - N
822
- 365
S - T
521 - 432
G - N
267
- 3
S - P
1090 - 781
N - H
247
- 407
D - T
164 -262
H - L
422
-67
T - E
608 - 476
L - I
306
- 375
-WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and d, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, 4451 St. Lucie Blvd,
349te
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
46
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
0 nwinht M 201a A-1 Rnnf TnimsP_c - R.nmd-1ion of this dov.-anf. in anv farmie nmhihifed withnnt the wriften nenniccion of A4 Ronf Tni. v ,
Joo r hiss r rubs i ypc wly cry V Vrua/LULU
WRMSBM1674132 I Al2 ( HIPS 11 11
a
�- 6'3"4 22'8"
s 5X8 =4X4 III 1.5X4= 3X6 =5X6
12 C D E F G H
9' --�
T6 11111.5X4
co (a)
o B J
`r A =5X6
11a 6X6 1111.5X4 g R Q p K=3X
t Z Y X UTV =4X8=3X6 III .5X4 M
1113X6 =3X8 III1.5X4 =4X4
SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ.
r-- 13'3"1 24'8"3
P„1a 15,5„6 48 14,5„6 1j18 7,9„8 _f_ 4"
37' 11 "4
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl Lid
TCDL: 10.00
Speed: 160 mph
TPI Sid: 2014
VERT(LL): 0.071 P 999 36
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.134 P 999 24
BCDL: 7.00
Risk Category: 11
FT/RT:10(0)/10(10)
HORZ(LL): 0.023 M -
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.044 M
Des Ld: 37.00
Mean Height: 15.00 ft
WAVE
NCBCLL: 10.00
TCDL: 4.2 psf
Creep Factor: 2.0
Load Duration: 1.25
BCDL: 4.2 psf
Max TC CSI: 0.793
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
Max BC CSI: 0.804
C&C Dist a: 3.79 ft
Max Web CSI: 0.655
Loc. from endwall: not in 9.00
Wgt: 231.0 Ibs
GCpi: 0.18
VIEW Ver: 19.01.00A.0618.15
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Bracing
(a) Continuous lateral restraint equally spaced on member.
Plating Notes
All plates are 3X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 6.27 28.94
BC 75 0.00 30.29
BC 93 30.29 37.79
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
2513
II
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
0 Z 463 /- /-
/426 /206 /149
- X 1835 /- /-
/982 /406 /-
K 894 /- /-
/559 /230 /-
Wind reactions based on MWFRS
Z Brg Width = 6.9
Min Req = 1.5
X Brg Width = 7.6
Min Req = 2.2
K Brg Width = 7.6
Min Req = 1.5
Bearings Z, X, & K are a rigid surface.
Bearings Z, X, & K require
a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 37 0
G- H 583 -1095
B - C 588 - 352
H - 1 850 -1611
C - D 869 - 297
I - J 765 -1641
D - E 281 - 392
J - K 659 -1444
E- F 281 - 392
K- L 35 0
F - G 281 - 392
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
Z - Y
173 -135
S - R
1083
- 342
Y - X
42 - 83
R - Q
1083
- 342
W-U
504 -818
Q-N
1198
-417
X-V
9 -18
P-O
0
0
U - S
507 - 835
O - M
38
-18
V- T
0 0
M- K
1249
- 524
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
B - Z
580 - 425
E - S
155
- 315
B - Y
226 - 345
G - Q
241
-48
C - Y
229 - 360
Q - H
87
-128
C - W
799 -1049
H - N
620
- 347
Y - W
369 - 380
N - O
75
- 5
W - X
945 -1733
N - 1
171
-165
W - D
584 -1240
N - M
1245
- 519
D - S
1493 - 644
N - J
182
- 58
U - V
90 -42
M - J
161
- 320
S-G
416 -860
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:onvdnht 2aie A-1 Ronf Tniecr_s - Ronrndur]inn of this dnnllmnnl. in anv form. in nrohihited without thr. wdttnn nnmin�inn of A-1 Ronf Tnim-
Jon 1 russ I russ I ype Cary my ubfuafzuzu
WRMSBM167462 I A13 I HIPS 1 1 I 2539
280 i 1871 187+ 187#+ 187#4 1871 190 �190I � 190 + 190+ 1901 1901 190#4 430#�- 7'0"6 -�
F-4-3"4 1 26'8' + 7'
12 a3X10
6 D
=4X6 T3 R7X6(R)
H I J
B
)"W8
(a)
K�4X41AC
r5EAA
:�N6X6
wH0714
0
T' .s
7X8 III1.5X4U T
�6X12 �H0308
S 63 R
a
L=4X6(A2) 35
M
Z Y W V X
3X6 N
=3X8
1111111.5X4
=6X6
SEAT PLATE REQ.
SEAT PLATE REQ.
SEAT PLATE REQ.
I- 13'3"l
24'8"3
P"a 165"6
14'5"6 - " ^- 778
37'11"4
4'3'10 2 0'6 2' 22' 2' 2' �3 i 3 i 2' -�"-- 2' � 2' - t - 21-t 2, 1 i
213 111# 11 111# Ill 98# 98# 98# 98# 98# 98# 98# 98# 603#
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL• 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a:3.79 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2 :T2 2x4 SP 2400f-2.OE:
:T3 2x4 SP M-30:
Bot chord 2x4 SP M-30 :B1 2x4 SP #2:
:63 2x4 SP 2400f-2.0E:
Webs 2x4 SP #3 :W7, W13 2x4 SP #2:
:W8 2x4 SP M-30:
012 2x4 SP 2400f-2.OE:
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Bracing
(a) Continuous lateral restraint equally spaced on member
Special Loads
-----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 pIf at -1.40 to 62 plf at 4.27
TC: From 31 pIf at 4.27 to 31 plf at 30.94
TC: From 62 plf at 30.94 to 62 pIf at 39.27
BC: From 14 pIf at 0.00 to 14 pIf at 4.30
BC: From 7 plf at 4.30 to 7 pif at 30.65
BC: From 14 plf at 30.65 to 14 plf at 37.94
TC: 280 lb Conc. Load at 4.30
TC: 187 lb Conc. Load at 6.33, 8.33,10.33,12.33
14.33
TC: 190lb Conc. Load at 16.33,17.60,18.87,20.87
22.87,24.87,26.87,28.87
TC: 430 lb Conc. Load at 30.91
BC: 213 lb Conc. Load at 4.30
BC: 111 lb Conc. Load at 6.33, 8.33,10.33,12.33
14.33
BC: 98 lb Conc. Load at 16.33,17.60,18.87,20.87
22.87,24.87,26.87,28.87
BC: 603 lb Conc. Load at 30.91
Plating Notes
All plates are 3X4 except as noted.
Deft/CSI Criteria
PP Deflection in loc L/defl L//
VERT(LL): 0.233 R 999 3(
§tRT(CL): 0.433 R 679 2
HORZ(LL): 0.060 N -
HORZ(TL): 0.112 N -
Creep Factor: 2.0
Max TC CSI: 0.676
Max BC CSI: 0.987
Max Web CSI: 0.726
Wgt: 232.4 Ibs
VIEW Ver: 19.01.00A.0618.15
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 4.27 30.94
BC 75 0.00 15.30
BC 43 15.30 30.79
BC 85 30.79 37.79
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Left bottom chord exposed to wind.
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
40 AC 470 /- /- /- /198 /-
- Z 4890 /- i- /- /1626 /-
L 2005 I- l- I- /630 /-
Wind reactions based on MWFRS
AC Brg Width = 6.9 Min Req = 1.5
Z Brg Width = 7.6 Min Req = 5.8
L Brg Width = 7.6 Min Req = 2.4
Bearings AC, Z, & L are a rigid surface.
Bearings AC, Z, & L require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 37 -17 G - H 232 - 864
B - C 195 - 395 H -1 1026 - 3462
C - D 590 -106 I - J 1423 - 4665
D - E 3473 -1082 J - K 1661 - 5205
E - F 232 - 864 K - L 1157 - 3710
F - G 232 - 864 L - M 35 -16
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
AC -AB 6 0 U - T 3352 - 999
AB -AA 304 -152 T - S 3352 - 999
AA- Z 103 - 325 S - R 4647 -1423
Z - X 23 - 79 R - O 4766 -1512
Y- W 1027 - 3297 Q- P 0 0
X-V 0 0 P-N 156 -50
W - U 1049 - 3374 N - L 3253 -1009
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
B -AC 218 -455 F - U 270 - 639
B -AB 316 -160 U - H 896 - 2905
C -AB 244 -17 H - S 969 - 239
C -AA 326 -1132 S - I 468 -1397
AA- D 1013 -295 I - R 150 0
AA-Y 15 -316 R-J 103 -112
D - Y 1103 - 3253 O - P 639 -191
Y - Z 1498 - 4503 O - J 1619 - 472
Y - E 1014 - 3146 O - N 3216 - 994
E - U 4949 -1495 O - K 1429 - 481
W - X 25 - 82 N - K 370 -1034
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-I. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cn-mlit 0 2016 A-1 Ronf Tmcse_v - R-mrinntinn of this rl-ninntin snv fnnnis nrohihifM uAthont thn wnttnn nnnni-inn of A4 Ronf Tnisses.
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
AC -AB 6 0 U - T 3352 - 999
AB -AA 304 -152 T - S 3352 - 999
AA- Z 103 - 325 S - R 4647 -1423
Z - X 23 - 79 R - O 4766 -1512
Y- W 1027 - 3297 Q- P 0 0
X-V 0 0 P-N 156 -50
W - U 1049 - 3374 N - L 3253 -1009
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
B -AC 218 -455 F - U 270 - 639
B -AB 316 -160 U - H 896 - 2905
C -AB 244 -17 H - S 969 - 239
C -AA 326 -1132 S - I 468 -1397
AA- D 1013 -295 I - R 150 0
AA-Y 15 -316 R-J 103 -112
D - Y 1103 - 3253 O - P 639 -191
Y - Z 1498 - 4503 O - J 1619 - 472
Y - E 1014 - 3146 O - N 3216 - 994
E - U 4949 -1495 O - K 1429 - 481
W - X 25 - 82 N - K 370 -1034
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-I. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cn-mlit 0 2016 A-1 Ronf Tmcse_v - R-mrinntinn of this rl-ninntin snv fnnnis nrohihifM uAthont thn wnttnn nnnni-inn of A4 Ronf Tnisses.
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
B -AC 218 -455 F - U 270 - 639
B -AB 316 -160 U - H 896 - 2905
C -AB 244 -17 H - S 969 - 239
C -AA 326 -1132 S - I 468 -1397
AA- D 1013 -295 I - R 150 0
AA-Y 15 -316 R-J 103 -112
D - Y 1103 - 3253 O - P 639 -191
Y - Z 1498 - 4503 O - J 1619 - 472
Y - E 1014 - 3146 O - N 3216 - 994
E - U 4949 -1495 O - K 1429 - 481
W - X 25 - 82 N - K 370 -1034
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-I. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cn-mlit 0 2016 A-1 Ronf Tmcse_v - R-mrinntinn of this rl-ninntin snv fnnnis nrohihifM uAthont thn wnttnn nnnni-inn of A4 Ronf Tnisses.
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-I. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cn-mlit 0 2016 A-1 Ronf Tmcse_v - R-mrinntinn of this rl-ninntin snv fnnnis nrohihifM uAthont thn wnttnn nnnni-inn of A4 Ronf Tnisses.
uoD buss
WRMSBM1674B2 I B01
I russ I ype
JACK
ury Fly
2 1 1
Ub/UWZUZU
2514
1
12
2X4(A1) B
SEAT PLATE REQ.
�- 1'4" -+ 1'10"15
C
T
0
M
r
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.000 D
Des Ld: 37.00
EXP: B Kzt: NA
Mean Height: 15.00 ft
Plate Type(s):
WAVE
HORZ(TL): 0.000 D - -
NCBCLL: 10.00
TCDL: 4.2 psf
Creep Factor: 2.0
Load Duration: 1.25
BCDL: 4.2 psf
Max TC CSI: 0.282
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.046
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Loc. from endwall: Any
Wgt: 8.4 Ibs
GCpi: 0.18
VIEW Ver: 19.01.00A.0618.15
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 21 0.15 1.91
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
0
r
0
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 193 /- /- 1155 /50 /47
D 24 /- /- /21 /7 /-
C 27 /- /- /18 /12 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 35 0 B-C 12 -41
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
`*WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI.1. The approval of the TDD and any Feld
4 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
4451 St. Lucie Blvd, Suite 201
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cn mhf n 2nia A-1 Rnnf Tnissec — Renrorluelinn o(fhis dnnnmenf. in anv faro. is nmhlhitod without the written nenniceian of A-1 Rnnf "r
JOD truss hubs ryyG try ny VUrvarGVGv
WRMSBM1674B2 I B02 JACK ( 2 1 I 2515
12
6
T=2X4(A1) B
1 T A
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
D
1113X4(++) C T
0
rn
H 8"12 Zo
1"
1111 X4
SEAT PLATE REQ. 1 $
f' 2 6"2„I
1,4n {?"�
E- 3214 -j
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Plating Notes
(++) - This plate works for both joints covered.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 30 0.15 2.36
BC 13 2.36 3.24
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): 0.006 G
999 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(CL): 0.011 G
999 240
B 229 /_ /_ /172 /51 /66
HORZ(LL): 0.004 G
- -
E 31 /- /- /22 /4 /-
HORZ(TL): 0.007 G
D 77 1- /- /42 /29 /-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.282
B Brg Width = 7.6 Min Req = 1.5
Max BC CSI: 0.054
E Brg Width = 1.5 Min Req = -
Max Web CSI: 0.053
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Wgt: 16.8 Ibs
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.15
Chords Tens.Comp. Chords Tens. Comp.
A- B 35 0 C- D 35 - 80
B-C 3 -88
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-H 10 -23 G-E 0 0
C-G 33 -2 H -F 0 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
G - H 48 - 22
.*WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing JDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvrinht C12016 A-1 Rod Tntccr_s — Renrodn Jinn of this dmimantin anv foon, is ornhihitsd vith-1 the written nannission of AA Roof Tmcses
JOD
WRMSBM1674B2
I rubs
B03
I I ubb I ypu
JACK
t tty I cry
4 1
VO/VV14VLV
2516
4P
SEAT PLATE REQ.
C
114
n_w1a _ZY90
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
B 206 A /- /160 /50 /55
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.001 D
D 34 !- A /26 /4 A
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.001 D
C 48 !- A /19 /21 A
Des Ld: 37.00
Mean Height: 15.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 4.2 psf
Max TC CSI: 0.322
B Br Width = 7.6 Min Re 1.5
Load Duration: 1.25
BCDL: 4.2 psf
Max BC CSI: 0.048
D Brg Width = 1.5 Min Req
g q
Spacing:24.0 "
MWFRS Parallel Dist: 0 to h/2
C Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Bearing B is a rigid surface.
Loc. from endwali: Any
Wgt: 11.2 Ibs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.15
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A-B 35 0 B-C 22 -68
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Purlins
Chords Tens.Comp.
In lieu of structural panels or rigid ceiling use purlins
B - D 0 0
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 28
0.15 2.46
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
ft 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St, Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
C.nnvrinht 0 201a A-1 Ronf Tniazas — Renrndnrlinn of this dnraiment. in nnv fnnn. iv nrnhihited , ithnnt thn written nnnniacinn of A-1 Rnnf Tn—
WRMSBM1674B2 I B04
JACK
12
6 F�7' -2X4(++) C
T*—=2X4(Al)B
A
SEAT PLATE REQ.
1'4" ---
i 2,6"2 I
HB 1'5"14
1ty 11y I �,��,����
2517
D
�— 1'4"6 ---
r 4' -1
1
l
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code:FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Sid: 2014
VERT(LL): 0.019 F 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.034 F 999 240
B 254 /- /- /186 /54 /77
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.011 G - -
E 44 /- /- /29 /4 /-
Des Ld: 37.00
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.020 G
D 102 /- /- /55 /40 /-
Mean Height: 15.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 4.2 psf
Max TC CSI: 0.201
B Brg Width = 7.6 Min Req = 1.5
Load Duration: 1.25
"
BCDL: 4.2 sf
p
Max BC CSI: 0.070
E Brg Width = 1.5 Min Req = -
Spacing: 24,0
MWFRS Parallel Dist: 0 to h/2
D Brg Width = 1.5 Min Req = -
C&C Dist a: 3.06 it
Max Web CSI: 0.076
Bearing B is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 18.2 Ibs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver. 19.01.00A.0618.15
Chords Tens.Comp. Chords Tens. Comp.
Lumber
Top chord 2x4 SP #2
A - B 35 0 C - D 46 - 70
Bot chord 2x4 SP #2
B - C 2 -82
Webs 2x4 SP #3
Maximum Bot Chord Forces Per Ply (Ibs)
Plating Notes
Chords Tens.Comp. Chords Tens. Comp.
(++) - This plate works
for both joints covered.
B - H 19 -27 G - E 0 0
Purlins
C- G 36 -5 H- F 0 0
In lieu of structural panels
or rigid ceiling use purlins
to laterally brace chords
as follows:
Maximum Web Forces Per Ply (Ibs )
Chord Spacing(in
oc) Start(ft) End(ft)
Webs Tens.Comp.
BC 30
0.15 2.36
G H 52 21
BC 22
2.36 4.00
-
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
**WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lude Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C'onvr aht n 2016 A-1 Roof Tn,mes — Renmdimlion of this de-reAntin env form, is nmhihited without the wdffao nenni-m of AA Roof Tnusvee
aoo truss I russ I ype ury rly unfuafzuZu
WRMSBM1674B2 I It, I COMN 1 1
2666
27# 75# 2# 75# 27#
�--- 21 "8 --#-- 1 10 877- 0"14 9 2 9" + 14 1,10"8 -- -- 21 "8 ---{
L r 1'4"14" ! 318" 1 1-6"4 -+{3,8" ,! 1'4"14 ;
12
4.24
p
=5X6
E=5X6 F
T
12
T2
"45X6 T
G T2
m3X5X6D
6
=3X8
v
05X6 C
Hk5X6
N
1 T
--7�-
altw
_2X4(A1)B
1111.5X4� -3X4
ML
L2X4(A1) r
A R
Q P
1111.5X4 K
M3X4
W1.5X4
=3X4
SEAT PLATE REQ.
SEAT PLATE REQ.
11'8"
�- 1 W 3'0"4
+
579
I 3'0"4 1,4"
4
4 4
+
24#
34
44fF
48# 48#
34
24#
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: 11
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2 :T2 2x6 SP 2400f-2.OE:
Bot chord 2x4 SP #2 :132 2x6 SP #2:
Webs 2x4 SP #3
Special Loads
-----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 plf at -1.33 to 62 plf at
1.41
TC: From 31 plf at 1.41 to 31 pif at
10.26
TC: From 62 plf at 10.26 to 62 plf at
13.00
BC: From 7 pif at 0.00 to 7 plf at
11.67
TC: 27 lb Conc. Load at 2.12, 9.54
TC: 77 lb Conc. Load at 4.00, 7.67
TC: 75 lb Conc. Load at 5.07, 6.59
TC: 102 lb Conc. Load at 5.83
BC: 24 lb Conc. Load at 2.12, 9.54
BC: 31 lb Conc. Load at 4.00, 7.67
BC: 48lb Conc. Load at 5.07, 6.59
BC: 44 lb Conc. Load at 5.83
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 5.07 6.59
BC 34 0.15 2.73
BC 67 2.73 8.65
BC 34 8.65 11.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Code / Misc Criteria
Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.315 M 433 36
§tRT(CL): 0.562 M 243 24
HORZ(LL): 0.249 K - -
HORZ(TL): 0.449 K -
Creep Factor: 2.0
Max TC CSI: 0.603
Max BC CSI: 0.986
Max Web CSI: 0.370
Wgt: 77.7 Ibs
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- ! Rh / Rw / U / RL
B 699 /- /- /- /215 /-
1 699 /- /- /- /215 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
1 Brg Width = 7.6 Min Req = 1.5
Bearings B & I are a rigid surface.
Bearings B & I require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens, Comp.
VIEW Ver: 19.01.00A.0618.15 I A - B
35 -16
F - G
477 -1852
B - C
238 - 876
G - H
259 - 956
C - D
260 - 957
H -1
238 - 876
D - E
474 -1843
I - J
35 -16
E - F
477 -1888
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - R
687 -184
N - L
1958
- 502
R - P
94 - 25
G - L
209
- 854
Q - D
205 - 845
M - K
94
- 25
Q - O
1951 - 500
K - I
687
-183
O - N
1918 -487
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Camp
C - R
126 - 422
N - F
84
- 230
R - Q
768 - 205
M - L
11
- 30
Q - P
11 - 30
L - K
767
- 204
E-O
79 -216
H-K
126
-421
E-N
13 -38
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvrinht 0201E A-1 Ronf Tnicsr_c - Renrndunlion of thin dnnntin nnv form. is nmhihited Wthnnt the vrtitten--in.,inn of AA Rnnf Tn.-,
,,,., .,cay , ,,, 2518
WRMSBM1674B2 B06 COMN 1 1
I . - 5'10" 5'10" -�
D///4X4(R1)
12
6 p
M
i� =4X4(++) C E=4X4(++)
<M
2X4(A1)B K J I H F_2X4(A1)
1 y 1111.5X4
A N M L III 1.5X4 G
1111.5X4
SEAT PLATE REQ. SEAT PLATE REQ.
11,8"
V4„ ,,1__ 2'6n2 64e12 10 2'6"2 _,1 V4n , I
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
TOLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Sid: 2014
BOLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
EXP: B Kzt: NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 15.00 ft
WAVE
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP 2400f-2.OE
Bot chord 2x4 SP #2
Webs 2x4 SP 43
Plating Notes
(++) - This plate works for both joints covered.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 30 0.15 2.36
BC 88 2.36 9.30
BC 30 9.30 11.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): 0.230 L 593 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(CL): 0,424 L 321 240
B 525 /- /- /320 /132 /110
HORZ(LL): 0.229 H - -
F 525 /- /- 1320 /132 /-
HORZ(TL): 0.422 H
Wind reactions based on MWFRS
Creep Factor: 2.0
B Brg Width = 7.6 Min Req = 1.5
Max TO CSI: 0.480
F Brg Width = 7.6 Min Req = 1.5
Max BC CSI: 0.313
Bearings B & F are a rigid surface.
Max Web CSI: 0.464
Bearings B & F require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Wgt:50.4lbs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 19.01.00A.0618.15
A - B 35 0 D - E 348 - 785
B - C 200 - 308 E - F 211 - 308
C- D 363 - 785 F- G 35 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B-N 111 -45 K-H 746 -211
C-M 571 -150 J-1 0 0
M-K 746 -211 I-F 111 -50
N -L 0 0 H-E 571 -143
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
M-N 96 -25 H - 1 96 -28
D-K 159 -10
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1.
r,nnwinht(cJ2n1e A-1 Rnnf Tnt.sr_-Rnnrcdijdinnnfthi. tdnrnmenl inanvfnnn. icnrohihiteivithotilthnwrittt..nnennisainnof A-1 Rnnf Tnr
Jon I russ I runs I ype uty vly U6/uarzuzU
WRMSBM1674B2 I C01 ( GABL 11 (1
1074 67# 67# 67#
+ 67#+ + 674+ + 674
+ + 107
3'0'6
i^-37*14- + 12'8'4 3'T14
�^ 10, fir
SEAT PLATE REQ.
SEAT PLATE REQ.
20'
I'- 3'0'6 --�- 2'0'62' --�-- 2' 1'10'8 ^ f^ 2' --�-- 2' --�-- 2'0'6
1044 44# 444 444
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL• 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwail: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP M-30
Bot chord 2x4 SP M-30
Webs 2x4 SP #3
Special Loads
-__-(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 plf at -1.33 to 62 plf at 3.03
TC: From 31 pif at 3.03 to 31 plf at 16.97
TC: From 62 pif at 16.97 to 62 pif at 21.33
BC: From 14 pif at 0.00 to 14 pif at 3.03
BC: From 7 plf at 3.03 to 7 pif at 16.97
BC: From 14 plf at 16.97 to 14 pif at 20.00
TC: 107 lb Conc. Load at 3.03,16.97
TC: 67 lb Conc. Load at 5.06, 7.06, 9.06,10.94
12.94,14.94
BC: 104 lb Conc. Load at 3.03,16.97
BC: 44 lb Conc. Load at 5.06, 7.06, 9.06,10.94
12.94,14.94
Plating Notes
All plates are 1.5X4 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 0 3.01 16.99
BC 99 0.15 19.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Deft/CSI Criteria
PP Deflection in loc L/defi L/#
VERT(LL): 0.212 H 999 36
k,lF_:RT(CL): 0.411 H 574 24
HORZ(LL): 0.088 D - -
HORZ(TL): 0.170 D
Creep Factor: 2.0
Max TC CSI: 0.696
Max BC CSI: 0.981
Max Web CSI: 0,417
Wgt: 134.4 Ibs
VIEW Ver: 19.01.00A.0618.15
Wind
Wind loads based on MWFRS.
Additional Notes
See STD DETAILS for gable wind bracing requirements.
Loading
Truss designed to support 2-0-0 top chord outlookers and cladding load not to
exceed 8.00 PSF one face and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
2541
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 2314 !- /- /773
/527 /329
J 2317 !- /- /773
/525 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 2.7
J Erg Width = 7.6 Min Req = 2.7
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per
Ply (Ibs)
Chords Tens.Comp. Chords
Tens. Comp.
A - B 75 - 27 F - G
1331 - 2190
B - C 1906 -4086 G - H
1244 -2252
C - D 1173 - 2440 H - 1
1172 - 2442
D - E 1245 -2251 I - J
1905 -4094
E-F 1331 -2190 J -K
75 -27
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - N 3585 -1512 M - L 3601 -1534
N - M 3593 -1502 L - J 3593 -1545
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - N
175 - 22
F - Q
1094 - 621
C - O
752 -1353
Q - R
763 -1369
C - M
248 - 288
R - S
758 -1362
O - P
757 -1362
S -1
752 -1353
P - Q
763 -1369
L - I
176 -17
M -1
257 - 297
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Comp
D - O 136 -213 R - G 277 - 267
E - P 277 - 264 S - H 136 - 214
Q - M 378 - 90
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Convrinht n 2016 A-1 Roaf Tmcses - Renrodnntion of this doraumonlin aov foro. is orohihited without the wnften nonnisc nn of A-1 Ronf Tnisses
WRMSBM1674B2 I CO2 1 COMNr 2" h 1,
2519
i, 10' i 10,
SEAT PLATE REQ.
1'4" —�
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
EXP: B Kzt: NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 15.00 ft
WAVE
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels
or rigid ceiling use purlins
to laterally brace chords
as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 120
0.15 19.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
D=4X4
=DAU
t
l
SEAT PLATE REQ.
20'
1'4" - I
Deft/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): 0.039 H
999 360
Loc R+ ! R- / Rh / Rw / U / RL
VERT(CL): 0.074 H
999 240
B 843 /- /- /491 /209 /165
HORZ(LL): 0.017 H
- -
F 843 /- /- /491 /209 /-
HORZ(TL): 0.033 H
Wind reactions based on MWFRS
Creep Factor: 2.0
B Brg Width = 7.6 Min Req = 1.5
Max TC CSI: 0.285
F Brg Width = 7.6 Min Req = 1.5
Max BC CSI: 0.854
Bearings B & F are a rigid surface.
Max Web CSI: 0.201
Bearings B & F require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Wgt:91.0lbs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 19.01.00A.0618.15
A- B 35 0 D - E 434 -926
B - C 523 -1253 E - F 523 -1253
C- D 433 - 926 F- G 35 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - H 1068 - 354 H - F 1068 - 385
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - H 226 - 344 H - E 226 - 344
D-H 518 -196
*"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 201
d, Suite
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, 4451 Si. Lucie Blvd,
349te Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPIA.
(:nnvdnht n 201a A-1 Roof Tni. s — Renindnntino of this d=on,ntin anv form, is nmhihited withnnt the wdten normiesinn of A-1 Ronf Tnieses.
JOu
WRMSBM1674B2
Iruss
CA
I russ I ype
JACK
ury Irly
6 1
U01W1/LULU
2520
Loading Criterialpsp
TCLL: 20.00
TCDL: 10.00
BCLL: 0-00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord 2x4 SP 42
Bot chord 2x4 SP #2
1
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 10 0.15 0.97
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
0
12
6 C
2X4(A1) B
SEAT PLATE REQ.
�— 1'4" — 1111111 - d
Code / Misc Criteria
Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Wind
Wind loads based on MWFRS with additional C&C member design.
T
LO
Defi/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): NA
Loc R+ 1 R- / Rh / Rw / U / RL
B 197 /_ /_ /172 /69 /33
VERT(CL): NA
HORZ(LL): -0,000 D
D 6 /-11 /- /15 /15 /-
HORZ(TL): 0.000 D
C - /-33 !- /29 /43 /-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.282
B Brg Width = 7.6 Min Req = 1.5
Max BC CSI: 0.036
D Brg Width = 1.5 Min Req = -
Max Web CSI: 0.000
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Wgt: 5.6 Ibs
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.15
Chords Tens.Comp. Chords Tens. Comp,
A-B 35 0 B-C 56 -29
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
`*WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the content of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
4451 St. Lucie Blvd, Suite 201
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terns areas defined in TPI-I.
r:nnvrinht n 2f11fi A-1 Rnnf TmggpG — Renrodimtion of thh dmiment. in anv fnnn. is nrnhihiterl wlthnut the wniten oermi.ainn of A.1 Rnnf Tnr. S
WRMSBM1674B2 I CAA I JACKJ, 1 1 I V 2521
12
6 F,—,- C
III 1.5X4B
TA N
°' H B 7"7 iv
eo
III 3X6E D
SEAT PLATE REQ.
�— 1'4"12 _4'i' 17 -'1
� 10"15 —{
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TOLL: 20.00 Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.000 B
999 360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.000 B
999 240 E 178 /- /- /171 /81 /-
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.000 B
- - D 15 /- /- /10 /- /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.000 B
C - /-32 /- 146 /60 /33
Des Ld: 37.00 Mean Height: 15.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00 TCDL: 4.2 sf
p
Max TC CSI: 0.180
E Brg Width = 6.9 Min Req = 1.5
Load Duration: 1.25 BCDL: 4.2 psf
Max BC CSI: 0,007
D Brg Width = 1.5 Min Req = -
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.094
Bearing E is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 8.4 Ibs
Bearing E requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 37 0 B - C 151 -59
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Purlins
E-D 0 0
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
Maximum Web Forces Per Ply (Ibs)
BC 11 0.00 0.91
Webs Tens.Comp.
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
B - E 317 -172
Wind
Wind loads based on MWFRS with additional C&C member design
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' forth.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd,201
d, Suite
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, 349te
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
Cnnvdnht n 2M A-1 Rnnf Tnietaa — Remndurfinn of this dmiment. in env form. is nmhihited withmit (hn written nenniacinn of A-1 Roof Tn.--
Job
WRMSBM1674B2
Iruss
CJ3
I russ I ype
JACK
Ubfuaf2UZU
2522
C
12
6
0
2X4(A1) B r LO
A p
SEAT PLATE REQ.
�-- 1'4" 2'11"11 -f{
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
Loc R+ ! R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
B 220 /- /- /167 /51 /62
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.001 D - -
D 43 /- /- !31 /2 /-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.001 D
C 66 /- /- /28 /29 /-
Des Ld: 37.00
Mean Height: 15.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 4.2 sf
p
Max TC CSI: 0.322
B Brg Width = 7.6 Min Req = 1.5
Load Duration: 1.25
BCDL: 4.2 psf
Max BC CSI: 0.072
D Brg Width = 1.5 Min Req = -
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Bearing B is a rigid surface.
Loc. from endwall: Any
Wgt: 11.2 Ibs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.15
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 35 0 B - C 30 -89
Top chord 2x4 SP 42
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Puriins
Chords Tens.Comp.
In lieu of structural panels or rigid ceiling use purlins
B - D 0 0
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 34
0.15 2.97
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 68906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
Convdnht n 2016 A-1 Roof Tnisses — Reenodnntinn of this do-menlin env formis nrnhibiled wifhnnl the wntfen nnnnit,inn of A-1 Ronf Tniesos.
goo t russ
WRMSBM1674B2 I CJ3A
t ,usI ype
I JACK
uty
( 1
riy UU/UtF/LULU
11 2523
C
12
T A;
w
91HB
1'11"7
III3X6 E
D
SEAT PLATE REQ.
P l-- 1-11
�-- 1'4"12 --
�-_ 22„15 _ ►�
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.000 B
999 360 Loc R+ ! R- / Rh ! Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.000 B
999 240 E 193 /- /- /169 176 !-
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): -0.000 B
- - D 38 /- /- 123 /- l-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.000 B
C 45 /- /- /38 /15 /53
Des Ld: 37.00 Mean Height: 15.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00 TCDL: 4.2 psf
Max TC CSI: 0.197
E Brg q Width = 6.9 Min Re 1.5
Load Duration: 1.25 BCDL: 4.2 psf
Max BC CSI: 0.050
D Brg Width = 1.5 Min Req
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C BrWidth = 1.5 Min Re
9 q
C&C Dist a: 3.00 ft
Max Web CSI: 0.091
Bearing E is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 14.0 Ibs
Bearing E requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 37 0 B - C 156 -52
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Purlins
E - D 0 0
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
Maximum Web Forces Per Ply (Ibs)
BC 27 0.00 2.24
Webs Tens.Comp.
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
B - E 305 -178
Wind
Wind loads based on MWFRS with additional C&C member design
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
d, Suite 201
4451 St. LuciuciPierce, e Blvd,te
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort 349te
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C nvrinht nc 2016 A-1 Roof Tni.-- Renrnduction of this domimentin anv fnnn, N nrohihited without tha written nonoic inn of A-1 Rnnf To-
Job I russ I russ I ype Ury cry Ubfuafzuzu
WRMSBM1674B2 ( CJ5 I JACK 1 3 1 1 2524
C
T
SEAT PLATE REQ.
f — 1'4" i' 411"11
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.005 D
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.008 D
Des Ld: 37.00
Mean Height: 15.00 ft
WAVE
NCBCLL: 10.00
TCDL: 4.2 psf
Creep Factor: 2.
Load Duration: 1.25
BCDL: 4.2 psf
Max TC CSI: 0510
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.284
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Loc. from endwall: Any
Wgt: 18.2 Ibs
GCpi: 0,18
VIEW Ver: 19.01.00A.0618.15
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 58 0.15 4.97
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
0
CV LO
Ch
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 288 /- /- /253 175 /92
D 77 !- /- 189 /35 /-
C 128 !- /- /69 /53 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 35 0 B-C 57 -156
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St, Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
(:nnvdnht a)2Ma A-1 Rnnf Tnreer_v— Renmdnntinn of thin do imentin anv fnnn. i� nmhihited vrithnut the written Dnrmicainn of A-1 Rnnf Tnts¢e.[.
n auu iluaa 11uaa iyNG .try wtvatww 2535
WRMSBM1674B2 I HJ3 I HIP_ 12 11y
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: B Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 0 plf at -1.89 to 61 plf at 0.00
TC: From 2 plf at 0.00 to 2 plf at 4.18
BC: From 2 plf at 0.00 to 2 plf at 4.18
TC: -20 lb Conc. Load at 1.38
BC: 12 lb Conc. Load at 1.38
Purlins
In lieu of structural panels or rigid ceiling use puriins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 48 0.15 4.18
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
-20#
1 2'9"10 -- -�
ff
SEAT PLATE REQ.
�--- 1'10"10 -}- 42"3 -�
f-- 1'4"8
12#
Code / Misc Criteria
Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
11
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
ktRT(CL): NA
HORZ(LL): -0.002 D
HORZ(TL): 0.003 D
Creep Factor: 2.0
Max TC CSI: 0.100
Max BC CSI: 0.133
Max Web CSI: 0.000
Wgt: 16.8 Ibs
VIEW Ver: 19.01.00A.0618.15
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 169 /- /- /- /104 /-
D 61 /-1 /- /- /9 /-
C 40 /-5 /- /- /14 /-
Wind reactions based on MWFRS
B Brg Width = 10.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 19 -9 B-C 22 -11
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
lv
4451 St. Lucie Blvd, Suite
(e 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
ss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, 349te
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
G-6aht cn 2n1e A-1 Roof Tnttxn_v - R-ritinlinn of thie domimenlin anv fnnnis nmhihited without the written oormisainn of A-1 Roof To-,
ion 1 n1Ss
WRMSBM1674B2 HJ7
I russ I ype Uty Hly
HIP_ 1 I
1
oeivaf2u2u
2536
1
-20# 256#
132#
i �- 2'9"10 --{
SEAT PLATE REQ.
1'10"10 1 9110"1
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Sid: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP M-30
Bot chord 2x4 SP 2400f-2.OE
Webs 2x4 SP #3
Special Loads
----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 61 plf at -1.89 to 61 plf at 9.84
BC: From 14 pif at 0.00 to 14 plf at 9.84
TC: -20 lb Conc. Load at 1.38
TC: 132 lb Conc. Load at 4.21
TC: 256 lb Conc. Load at 7.03
BC: 12 lb Conc. Load at 1.38
BC: 86 lb Conc. Load at 4.21
BC: 155 lb Conc. Load at 7,03
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 116 0.15 9.84
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
D
�-- V4"9 --{-- 2,9"15 8j 2,9"15 --�
t 86#
12# 155#
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Sid: 2014
VERT(LL): 0.037 G 999 360
Loc R+ / R- / Rh / Rw / U / RL
B 739 /- /- /- /343 /-
Rep Factors Used: Varies by Ld C
§PERT(CL): 0.066 G 999 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.008 F - -
E 492 /- /- /- /152 /-
Plate Type(s):
HORZ(TL): 0.015 F
D 243 /- /- /- /103 /-
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.667
B Brg Width = 10.0 Min Req = 1.5
Max BC CSI: 0.561
E Brg Width = 1.5 Min Req = -
Max Web CSI: 0.904
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Wgt: 44.8 Ibs
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.15
Chords Tens.Comp, Chords Tens. Comp.
A-B 37 -17 C-D 81 -116
B - C 549 -1452
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B- G 1353 -488 F- E 0 0
G - F 1338 - 487
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
G - C 241 -11 C - F 508 -1396
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Mstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
Blvd,
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, 349te
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
(:nnvdnht no 2me A-1 Rnnf Tmases - Renrodnrtion of this dwiiment. in anv fnnn. is nmhihitod vAthnut tha wditen nermissinn of A-1 Ronf Tmcses
JOU IfUbb Hubb Iypti WLy rty UUIUU14UZV
WRM5BM1674B2 I HJ7S HIP_ I 1 ( 1 ( 2537
a
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Special Loads
-----(Lumber Dur.Fac.=1.25 ! Plate Dur.Fac.=1.25)
TC: From 0 pif at -1.97 to
61 plf at 0.00
TC: From 2 pif at 0.00 to
2 plf at 5.98
BC: From 2 plf at 0.00 to
2 plf at 5.98
TC: 66 lb Conc. Load at 0.35
TC: -12 lb Conc. Load at 1.29
TC: 173 lb Conc. Load at 3.17
BC: 43 lb Conc. Load at 0.35
BC: 15 lb Conc. Load at 1.29
BC: 116lb Conc. Load at 3.17
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 72 0.00 5.98
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Left bottom chord exposed to wind.
66# .12N+ 173#+
2'9"10'_'�
12
4.24 (j'
a
1I1.5X4B
TA
HB 5'8"4
E D
A1.5X4
SEAT PLATE REQ.
-41- 5'8'4 +I
I--- 5'11"12
r 1-�-- T1'10'10
15#
43# 116#
Code / Misc Criteria
Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defi L/#
VERT(LL): -0.000 B 999 36,
%06RT(CL): 0.001 B 999 24
HORZ(LL): 0.000 B - -
HORZ(TL): 0.000 B
Creep Factor: 2.0
Max TC CSI: 0.723
Max BC CSI: 0.562
Max Web CSI: 0.039
Wgt: 23.8 Ibs
VIEW Ver: 19.01.00A.0618.15
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
E 320 ! /- /- /141 /-
D 102 /- /- 1- /12 /-
C 93 /- /- /- /42 /-
Wind reactions based on MWFRS
E Brg Width = 9.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Bearing E requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 20 - 9 B- C 34 -49
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
E-D 0 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
B - E 131 - 207
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TOO to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C.n Min 02Mfi A-1 Rnnf T.-- Renrnrtnnlinn of this rinrnmontin anv form, is nrahihiteri withnmt the written nerni-inn of A-1 Rnnf Tnrcvas
Job I russ 1 russ 1 ype Qry I My UoruaiZuZu
WRMSBM1674B2 I HJB1 I HIP_ 2 1 2538
97#+
e f"_ 1-7.10
D
12 T T
T =2X4(Ai)B H81� iv N
1 A O�{ FF 1
111�X4
SEAT PLATE REQ. 1 g
jam- 2'8"12 --'1•I
h-- 1'5. VS-12 ---{
r4'3"15 ---j
I-- 2 8"5 -J
68#
Loading Criteria (psi) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl
L/# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.025 F 999
360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Varies by Ld C §q-RT(CL): 0.048 F 999
240 B 161 /- /- /- /33 /-
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.013 G -
- E 48 /- /- /- /3 !-
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.025 G
D 75 /- /- /- /17 !-
Des Ld: 37.00 Mean Height: 15.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00 TCDL: 4.2 sf
p
Max TC CSI: 0.334
B Brg Width = 8.3 Min Req = 1.5
Load Duration: 1.25 BCDL: 4.2 psf
Max BC CSI: 0.096
E Brg Width = 1.5 Min Req = -
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
D Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.106
Bearing B is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 19.6 Ibs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp.
Lumber
C - D 32 10
Top chord 2x4 SP #2
_ C 14 60
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Maximum Bot Chord Forces Per Ply (Ibs)
Special Loads
Chords Tens.Comp. Chords Tens. Comp.
-----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
B - H 23 -5 G - E 0 0
TC: From 0 pif at -1.42 to 62 plf at -0.00
C - G 18 0 H - F 0 0
TC: From 2 pif at -0.00 to 2 plf at 4.33
BC: From 2 plf at 0.00 to 2 plf at 4.33
TC: 97 lb Conc. Load at 2.69
Maximum Web Forces Per Ply (Ibs)
BC: 68 lb Conc. Load at 2.69
Webs Tens.Comp.
Plating Notes
G - H 87 -7
(++) - This plate works for both joints covered.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 32 0.15 2.58
BC 23 2.58 4.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
**WARNING** Please thoroughly review the "A-t ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TOO, only Alpine
connector plates shall be used for the TOO to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TOO only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav KHstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TOO and the practices and
4451 St. Lude Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C-flnht () 201a A-1 Finer To.--- RonmtiuMino of this tins iment in anv Connis nrohihited without the whiten nenoi inn of A-1 Roof Te-n
WRMSBM1674B2 ( J3„
uaa yp.
EJAC
l.2ly r-ly
8 1
2525
T
SEAT PLATE REQ.
114" + 31
Loading Criteria (pst)
Wind Criteria
Code / Misc Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
EXP: B Kzt: NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 15.00 ft
WAVE
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0"
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Puriins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 34 0.15 3.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
C
Defl/CSI Criteria ♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/# Gravity Non -Gravity
VERT(LL)• NA I Loc R+ / R- / Rh / Rw / U / RL
VERT(CL): NA
HORZ(LL): 0.001 D
HORZ(TL): 0.001 D
Creep Factor: 2.0
Max TC CSI: 0.322
Max BC CSI: 0.075
Max Web CSI: 0.000
Wgt: 11.2 Ibs
VIEW Ver: 19.01.00A.0618.15
B 221 /- /- 1168 /51 /63
D 44 /- /- /31 /2 /-
C 67 /- i- /29 /29 /-
Wind reactions based on MWFRS
B Brg Width = 7.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 35 0 B-C 30 -90
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucia Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
Cnnvriaht P 2016 A-1 Roof To,.-- Ranrndutlinn of this rinm—ntin anv form, is nrohihifnd wifhtnit th" writfnn nonni-in. of A4 R—f Toi. Cns.
JOD
WRMSBM1674B2
I cuss
J34
I russ I ype Ury cry
JACK 14 11
unruWZUZU
2526
4"3
31411
C
Loading Criteria (pst)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
TCDL: 10.00
Speed: 160 mph
TPI Sid: 2014
VERT(LL): NA
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
BCDL: 7.00
Risk Category: 11
FT/RT:10(0)/10(10)
HORZ(LL): 0.001 D
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.002 D
Des Ld: 37.00
Mean Height: 15.00 ft
WAVE
NCBCLL: 10.00
TCDL: 4.2 psf
Creep Factor: 2.0
Load Duration: 1.25
BCDL: 4.2 psf
Max TC CSI: 0.143
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.144
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Loc. from endwall: not in 4.50
Wgt: 12.6 Ibs
GCpi: 0.18
VIEW Ver: 19.01.00A.0618.15
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 39 0.13 3.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left bottom chord exposed to wind.
M
N
♦ Maximum Reactions (Ibs)
Gravity
Loc R+ / R- / Rh
Non -Gravity
/Rw /U /RL
B 201 /- /- /177 /54 /63
D 51 /- /- 159 /23 /-
C 83 /- /- /44 /34 /-
Wind reactions based on MWFRS
B Brg Width = 3.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 26 0 B-C 37 -74
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (Le, Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4461 St. Lucie Blvd,201
d, Suite
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, 349te
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvdrht 0 21116 A-1 Roof Tn,. , — Rvnrodnntion of thk donnmantin anv fnm is nrnhihitnd vrithont tha writtan 000niWon of A-1 Roof Tnzs
uuu wa
WRMSBM1674B2 J3GE
u uaa ryp.
JACK
2527
4P
�- 1'4" ---
rr
SEAT PLATE REQ.
2'7"11
p 1111.5X4
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.001 D
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.001 D
Des Ld: 37.00
Mean Height: 15.00 ft
WAVE
NCBCLL: 10.00
TCDL: 4.2 psf
Creep Factor: 2.
Load Duration: 1.25
BCDL: 4.2 psf
Max TC CSI: 0186
Spacing: 24.0 "
MWFRS Parallel h to 2h
Max BC CSI: 0.046
_Dist:
C&C Dist a: 3.00 ft
Max Web CSI: 0.038
Loc. from endwall: not in 9.00
Wgt: 14.0 Ibs
GCpi: 0.18
VIEW Ver: 19.01.00A.0618.15
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Puriins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 30
0.15 2.64
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design
T
1
T
1
♦ Maximum Reactions (Ibs), or *=PLF
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
D* 106 /- /- 176 /13 /15
Wind reactions based on MWFRS
D Brg Width = 31.7 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 35 0 B-C 23 -53
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 155 -31
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
C - D 89 - 54
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the RC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TOO and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:nnvrioht n 2016 A-1 Roof Tmcsn_c— R-rodurtion of this doonmentin anv formis nrohihited without the written nenniscinn of A-1 Roof Tom
Job
WRMSBM1674B2
Iruss
R
Iruss type
EJAC
7 ( 1y I Ut)/U`J/ZUZD
2528
SEAT PLATE REQ.
C
�-- V4"' 7' _ I
Loading Criteria (psi) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Slid: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): NA
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): NA
B 361 /- /- /317 /88 /121
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.015 D
D 111 /- /- /131 /52 /-
EXP: B Kzt: NA
37.00
Plate Type(s):
HORZ(TL): 0.027 D
C 187 !- /- /102 177 !-
Des Ld: Mean Height: 15.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00 TCDL: 4.2 sf
p
Max TC CSI: 0.711
B Brg Width = 7.6 Min Req = 1.5
Load Duration: 1.25 BCDL: 4.2 psf
D Brg Width = 1.5 Min Req = -
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.640
C Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.000
Bearing B is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 23.8 Ibs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.15
Chords Tens.Comp. Chords Tens. Comp.
Lumber
Top chord 2x4 SP #2
A - B 35 0 B - C 84 140
Bot chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Purlins
Chords Tens.Comp.
In lieu of structural panels or rigid ceiling use purlins
B - D 0 0
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member
design.
Left bottom chord exposed to wind.
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
Cnnvdnht n 2016 A-1 Roof Tmccoc— Renrori-A n of thi., do.—M in anv fnnnis mohihifed without thn wditan nnrmi-ion of A-1 Roof Tnia -
uoo 1 runs 1 russ I ype Ury ry unruar�u�u r
WRMSBM1674B2 (J7uC EJAC 8 1 I 2529
D
12
6 M
_O
N
1113X4(++)C M i�
v
T _2X4(A1) B HB 4'5"14 E
T A ��GG
1111.5X4
SEAT PLATE REQ.
�— V21" --E-- 2'6"2 Y r 4'4"6 — -{
7'
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Sid: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl
L/# Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Sid: 2014
VERT(LL): 0.171 F 482
360 Loc R+ / R- ! Rh / Rw / U ! RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.316 F 260
240 B 361 !- /- /252 /68 /121
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.081 G -
- E 98 /- i- /66 /8 /-
Des Ld: 37.00
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.151 G -
- D 190 /- /- /102 178 /-
Mean Height: 15.00 ft
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00
TCDL: 4.2 sf
p
Max TC CSI: 0786
B Brg Width = 7.6 Min Req = 1.5
Load Duration: 1.25
"
BCDL: 4.2 psf
.
Max BC CSI: 0.348
E Brg Width = 1.5 Min Req = -
Spacing: 24.0
MWFRS Parallel Dist: h/2 to h
D Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.279
Bearing B is a rigid surface.
Loc. from endwall: not in 9.00
Wgt: 28.0 Ibs
Bearing B requires a seat plate.
GCpi: 0.18
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration: 1.60
VIEW Ver: 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp.
Lumber
Top chord 2x4 SP #2
A - B 35 0 C - D 85 -118
Bot chord 2x4 SP #2
B - C 0 -197
Webs 2x4 SP #3
Maximum Bot Chord Forces Per Ply (Ibs)
Plating Notes
Chords Tens.Comp. Chords Tens. Comp.
(++) - This plate works
for both joints covered.
B - H 84 -73 G - E 0 0
Puriins
C- G 81 -36 H- F 0 0
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Maximum Web Forces Per Ply (Ibs)
Chord Spacing(in
oc) Start(ft) End(ft)
Webs Tens.Comp.
BC 30
0.15 2.36
G - H 72 34
BC 58
2.36 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' forth.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
d 88906
use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd,201
d, Suite
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, 349te
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvrinht,o 2ela A-1 Ronf T.c--- Renrorhirfinn of Ihix tlncumnnf in anv forth. is nrohihiteA without fhn writtt+.n nnmficvinn of A-1 Ronf True,
JOO
WRMSBM1674B2
1 russ
VM02
I russ I ype
VAL
cary fly
2 1
ub/L!WLULU
2530
0
Loading Criteria (pst)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: B Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 23 0.00 1.88
Apply puffins to any chords above or below fillers
at 24" OC unless shown otherwise above.
n
15
— 1 r3n9
12
6
1- 1' 10"8 I
%i
00
t-
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or *=PLF
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.005 B 999 360
Loc R+ / R- / Rh / Rw / U / RL
D' 76 /- /- /40 /11 /9
Rep Factors Used: Yes
VERT(CL): 0.009 B 999 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.002 B - -
Wind reactions based on MWFRS
Plate Type(s):
HORZ(TL): 0.004 B -
D Brg Width = 22.5 Min Req = -
WAVE
Creep Factor: 2.0
Bearing A is a rigid surface.
Max TC CSI: 0.059
Maximum Top Chord Forces Per Ply (Ibs)
Max BC CSI: 0.113
Chords Tens.Comp.
Max Web CSI: 0.000
A - B ' 0 -21
Wgt: 5.6 lbs
Maximum Bot Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.15
Chords Tens.Comp.
A-C 73 -4
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for valley details.
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
te
4451 St, Lucie B201
d, Suite
Blvd,
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Fort Pierce,
34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPIA,
Convnnht (2016 A-1 Roof This-- Ranrodnrtion of this doonmsntin anv form. is nmhihiod mthnnt thn. written nP Ission of AA Roof Tmsaas
WRMSBM1674B2 ( VM04
VAL
2531
T
2X4(D8R)
1i 111-1 GVA
31411
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Sid: 2014
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
EXP: B Kzt: NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 15.00 ft
WAVE
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: OA8
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use puriins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 40 0.00 3.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Additional Notes
See STD DETAILS for valley details.
1113X6
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.002 C
HORZ(TL): 0.004 C
Creep Factor: 2.0
Max TC CSI: 0.227
Max BC CSI: 0.141
Max Web CSI: 0.075
Wgt: 14.0 Ibs
VIEW Ver: 19.01.00A.0618.15
T
♦ Maximum Reactions (Ibs), or `=PLF
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
C* 76 /- /- /50 117 /14
Wind reactions based on MWFRS
C Brg Width = 40.0 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-B 36 -102
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-C 187 -10
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
B-C 193 -86
-WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TOO to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvdnht n 2016 A-1 Roof Tnix - Rannufuotinn of thN dm f io anv form. is nrnhihitad without tha wn"on narnisxion of A-1 Roof Tn.
JOu
WRMSBM1674B2
I I UJJ I t UAJ I yF1C
VM05 VAS
,tty r-Iy
1 I1
2532
T
M
1
i- 3'4" -�
�-- 1' -- {
t
1
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (lbs), or'=PLF
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10A0
Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.000 C
999 360
Loc R+ / R- / Rh / Rw / U / RL
D* 94 /- /- /66 /12 /13
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.000 C
999 240
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): -0.027 C
- -
Wind reactions based on MWFRS
Des Ld: 37.00
EXP: B Kzt: NA
Plate Type(s):
HORZ(TL): 0.035 C
D Erg Width = 40.0 Min Req = -
Mean Height: 15.00 ft
WAVE
Creep Factor: 2.0
Bearing E is a rigid surface.
9 9
NCBCLL: 10.00
TCDL: 4.2 psf
Max TC CSI: 0.218
Maximum Top Chord Forces Per Ply (Ibs)
Load Duration: 1.25
BCDL: 4.2 psf
Max BC CSI: 0.137
Chords Tens.Comp. Chords Tens. Comp.
Spacing: 24.0"
MWFRS Parallel Dist: h to 2h
A - B , 26 0 B - C 38 -75
C&C Dist a: 3.00 ft
Max Web CSI: 0.307
Loc. from endwall: not in 9.00
Wgt: 18.2 Ibs
GCpi: 0.18
Maximum Bot Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.15
Wind Duration: 1.60
Chords Tens.Comp.
Lumber
E - D 135 -23
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
Bracing
B - E 172 -171 C - D 159 -95
Fasten rated sheathing to one face of this frame.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 40 0.00 3.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member
design.
Right end vertical not exposed to wind pressure.
Additional Notes
See STD DETAILS for valley details.
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI.1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I.
Cnnvnnht (E) 2016 A-1 Roof Thlases - R—rodnntion of this domimentin anv fnnn. is nmhihited Athn,,t tha wditen nannissinn of A-1 Rnnf Tmsces.
WRMSBM 1674B2 ( VM06 VAL yNc ( 1 y 1y
2533
i — T4"
�— 1' --
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Code: FBC 2017 RES
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
EXP: B Kzt: NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 15.00 ft
WAVE
NCBCLL: 10.00
TCDL: 4.2 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #3
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 40 0.00 3.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C member design.
Left end vertical exposed to wind pressure. Deflection
meets L/360.
Right end vertical not exposed to wind pressure.
Additional Notes
See STD DETAILS for valley details.
c
01
i
1
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or'=PLF
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): 0.000 C
999 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(CL): 0.001 C
999 240
D` 94 /- /- /66 124 /30
HORZ(LL): -0.001 C
- -
Wind reactions based on MWFRS
HORZ(TL): 0.001 C
D Brg Width = 40.0 Min Req = -
Creep Factor: 2.0
Bearing E is a rigid surface.
Max TC CSI: 0.181
Maximum Top Chord Forces Per Ply (Ibs)
Max BC CSI: 0.106
Chords Tens.Comp. Chords Tens. Comp.
Max Web CSI: 0.114
A - B 26 0 B - C 40 -94
Wgt: 26.6 Ibs
Maximum Bot Chord Forces Per Ply (Ibs)
VIEW Ver: 19.01.00A.0618.15 Chords Tens.Comp.
E-D 41 -43
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B - E 127 -170 C - D 142 - 95
B - D 240 - 57
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI.1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unfess otherv,4se defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Fort Pierce, FL 34946
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I.
r:onvdnht n 207E A-1 Rnnf Tniscaa — Renmdn Ainn of this dmiment. in anv form. is nmhihited wiihrnil the written nnnniatinn of A-1 Rnnf Tnicvee
JUNE,20,2019
TYPICAL HIP / KING JACK CONNECTION I STDTL01
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
CORNERSET GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 175 mph, ASCE
7-10, Exp. B, C up to 60' Mean Roof Height
and Exposure D up to 30' Mean Roof Height.
Attach King Jack w/ (3) 16d Toe
,Nails @ TIC & BC
Attach End Jack's Attach Corner Jack's
w/ (4) 16d Toe Nails @ TIC w/ (2) 16d Toe Nails @ TIC &
& (3) 16d Toe Nails @ BC BC (Typ)
0
-1
rl_ %M
ttach Corner Jack's
(/ (2) 16d Toe Nails
@ TIC & BC (Typ)
Rama Pranav Kristam, P.E.
# BB906
4451 St, Lucie Blvd, Suite 201
Fort Pierce, Fl. 34946
FEBRUARY 17, 2017 ( ALTERNATE GABLE END BRACING DETAIL
STDTL00
ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD
HORIZONTAL BRACE
(SEE SECTION A -A)
TRUSSSES
24' O.C.
A,1 ROOF TRUSSES
4451 ST. LUCIE SLVD.
-
FORT PIERCE, FL 34946
772 409-1i110 1' - 3' MAX.
0\
DIAL. BRACE
AT 1/3 POINTS
IF NEEDED
\
IT IS THE OF THE BLDG,
DESIGNER OR THENSIBILITY PROJECT ENGINEER/ARCHITECT
TO DESIGN THE CEILING DIAPHRAGM AND ITS
ATTACHMENT TO THE TRUSSES TO RESIST ALL
OUT OF PLANE LOADS THAT MAY RESULT FROM
THE BRACING OF THE GABLE ENDS.
END WALL
2X6 DIAGONAL BRACE SPACED 48'
O.C. ATTACHED TO VERTICAL WITH
(4) - 16d NAILS, AND ATTACHED TO
BLOCKING WITH (5) - 10d COMMONS.
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO 16d NAILS.
2X4 PURLIN FASTENED TO FOUR
TRUSSES WITH (2) - 16d NAILS
EACH. FASTEN PURLIN TO BLOCKING
W/ (2) - 16d NAILS (MIN.).
PROVIDE 2X4 BLOCKING BETWEEN
THE TRUSSES SUPPORTING THE
BRACE AND THE TWO TRUSSES ON
EITHER SIDE AS NOTED. TOENAIL
BLOCKING TO TRUSSES WITH (2) -
10d NAILS AT EACH END. ATTACH
DIAGONAL BRACE TO BLOCKING WITH
(5) - 10d COMMON WIRE NAILS.
CEILING SHEATHING
BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE
OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAIL SCHEDULE.
METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL
MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG
SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL
NAILING SCHEDULE:
- FOR WIND SPEEDS 12D MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE
7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131'
X 3') NAILS SPACED 6' O.C.
- FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150
MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d
(.131'X3') NAILS SPACED 6' D.C. (2X4 STUDS MINIMUM).
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI
BRACING METHODS SHOWN ON PAGE 1 ARE VALID
AND ARE TO BE FASTENED TO THE SCABS OR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
--- I "TURAL
TRUSS
'b+nni
/ STRUCTURAL AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING
GABLE TRUSS / MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF
THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS.
THE BRACING SHOWN IN THIS DETAIL IS FOR
VERTICAL/STUDS ONLY.
NOTE: THIS DETAIL IS TO BE USED ONLY FOR
STRUCTURAL GABLES WITH INLAYED /
STUDS. TRUSSES WITHOUT INLAYED
STUDS ARE NOT ADDRESSED HERE. /
STANDARD GABLE /
\S /
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 2011
12/23/19, PIGGY -BACK TRUSS STDTL04.1
A-1 ROOF TRUSSES
4451 ST, LUCIE BLVD.
FORT PIERCE, FL 34946
772.409.1010
PIGGY-B�
TO ACT
DRAWING
OPTION Nt
3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED
AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO
PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM
EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH
6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE
MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8"
TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2
PLATES) .
OPTION NO. 2 - APA RATED GUSSET:
8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS
EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d
COMMON (0.1 13" x 2") NAILS PER GUSSET: 4 (EACH) AT
CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP
CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C.
FRONT TO BACK FACES. MINIMUM TWO (2 EA.)
CONNECTIONS AT EACH TRUSS,
OPTION NO.3 - 2X4 VERTICAL WOOD SCAB:
2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE.
ATTACH AT 8'-0" O.C. w/6 (EACH) 1 Od BOX NAILS (0.128"
x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND
3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE
STAGGERED 4'-0" O.C. FRONT TO BACK FACES.
MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS.
PIGGY -BACK DETAIL (TYPICAL)
180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
OR...
160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT 1.00.
IMPORTANT NOTE:
TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY
BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL
PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY
RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS.
MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C.
DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA,
STEEPLE, CHIMNEY OR DRAG STRUT LOADS.
"REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE
TRUSS SPECIFICATIONS."
OPTION #1: TEE-LOK MULTI -USE
CONNECTION PLATE.
OPTION #2: APA RATED GUSSET.
OPTION #3: 2X4 VERT. SCAB.
ATTACH EACH PURLIN TO TOP
CHORD OF BASE TRUSS. PURLIN
& CONNECTIONS BY OTHERS.
BASE TRUSS. (REFER TO TRUSS
DESIGN DRAWINGS FOR
ADDITIONAL INFORMATION.)
PURLINS SPACED ACCORDING
TO MAX. SPACING OF TOP
CHORD OF BASE TRUSS.
SPACING IS NOT TO EXCEED 24"
O.C. & PURLINS TO BE LOCATED
AT JOINT OF EACH BASE TRUSS.
** IMPORTANT NOTE **
THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES
SPACED AT 24" O.C. OR LESS.
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
JULY 17, 2017 ( TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD,
FORT PIERCE, FL 34946
772409-1010
VALLEY TRUSS
(TYPICAL)
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6" O.C.
DETAIL A
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 4.5" SDS25412 SIMPSON OR
EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL "A".
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NOS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
BASE TRUSSES
-C CIVU, I.VIvIIVIVIV
3S, OR GIRDER TRUSS
TRUSS CRITERIA:
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY 11 BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
ATTACH 2X4 CONTINUOUS 42 MAX SPACING = 24" O.C. (BASE AND VALLEY)
SYP TO THE ROOF W/ TWO MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
SIMPSON SDS25412 (1/4" X 4.5")
OR EQUIVALENT WOOD SCREWS
INTO EACH BASE TRUSS.
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
FEBRUARY 5, 2018 TRUSSED VALLEY SET DETAIL STDTI-06
. 14 1
GENERAL SPECIFICATIONS:
AWMW
1. NAIL SIZE= 3" X 0.131"= 10d
2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT.
3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL
"A".
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
sl DRAWINGS.
4,6411.1 how, 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
To THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
A-1 ROOF TRUSSES 6. NAILING DONE PER NDS - 01.
4461 ST, LUCIE BLVD, GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" D.C.
FORT PIERCE, FL 34946 TRUSS, OR GIRDER
772409-1010 TRUSS 7
SECURE
W/ (
II II II BASE TRUSSES
. .... . . ........ . I! Z
VALLEY TRUSS
(TYPICAL)
- - I --
(NO SHEATHING) N.T.S.
GABLE END, COMMON
TRUSS, OR GIRDER
P F 1-2 VALLEY TRUSS TRUSS
(TYPICAL)
SEE DETAIL "A"
BELOW (TYP.)
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05:146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY 11 BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
ATTACH 2X4 CONTINUOUS #2
MAX TOP CHORD TOTAL LOAD = 50 PSF
SYP TO THE ROOF W/ TWO
MAX SPACING = 24" O.C. (BASE AND VALLEY)
SIMPSON SDS25300 (1/4" X 3")
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
OR EQUIVALENT WOOD
SCREWS INTO EACH BASE
TRUSS.
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
JULY 17, 2017 I (CITY)
WIND VELOCITY) I STDTL07
I
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
ATTA(
WIND DESIGN PER ASCE 7-98, ASCE 7-1
WIND DESIGN PER ASCE 7-10: 170 MPt
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY II BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCREASE:
MAX TOP CHORD TOTAL LOAD = 50 PSI
MAX SPACING = 24" O.C. (BASE AND VA
SUPPORTING TRUSSES DIRECTLY UNDtK VALLtr I KUJAtJ MU51 bt
DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 10" ON AFFECTED
TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER.
NON -BEVELED
BOTTOM CHORD
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
CLIP MAY BE APPLIED
TO THIS FACE UP TO A
MAXIMUM 6112 PITCH
C
CLIP MUST BE APPLI1
THIS FACE WHEN I
EXCEEDS 6/12 (MAx
12/12 P
Rama Pranav Mstam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
FEBRUARY 17, 2017 STANDARD GABLE END DETAIL STDTL08
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
TYPICAL 2X4 L-BRACE
NAILED TO 2X4 VERTICALS
W/10d NAILS, 6' O.C.
V ERT
STUD
SECTION B-B
TRUSS GEOMETRY AND CONDITIONS
SHOWN ARE FOR ILLUSTRATION ONLY.
VERTICAL
2X6 SP OR SPF
STUD
#2 DIAGONAL
BRACE
(4) - 16d
NAILS
16d NAILS
SPACED 6' O.C.
(2) lOd NAILS
INTO 2X6
2X6 SP OR
SPF #2
2X4 SP OR
SPF #2
TYPICAL HORIZONTAL
BRACE NAILED TO
2X4 VERTICALS
SECTION A -A
W/(4) - 10d NAILS
DIAGONAL BRACE 4' - 0' O.C. MAX.
SEE INDIVIDUAL ENGINEERING DRAWINGS
FOR TRUSS DESIGN CRITERIA.
12 PROVIDE 2X4 BLOCKING BETWEEN
Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED.
TOENAIL BLOCKING TO TRUSSES
* WITH (2) - 10d NAILS AT EACH END.
ATTACH DIAGONAL BRACE TO
BLOCKING WITH (5) - 10d NAILS
(4) Bd NAILS MINIMUM, ROOF
B 3X4= PLYWOOD SHEATHING TO SHEATHING
2X4 STD SPF BLOCK
*
DIAGONAL BRACING ** L - BRACING REFER v
V 11
REFER TO SECTION A -A TO SECTION B-B 24' MAX.
/
2.
MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM C ORDS.
HAND
(2) - lOd
CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS WALL TO 12' MAX.
NAILS
BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3.
BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG.
ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF
4.
SYSTEM.
'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR
/
BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C.
TRUSSES @ 24' O.C.
5.
DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM
/
AT 4' - 0, D.C.
6.
CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN
2X6 DIAGONAL BRACE
WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT
SPACED 48' O.C. ATTACHED
THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE
__ TO VERTICAL WITH (4) -
STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A)
*'' 16d NAILS, AND ATTACHED
7.
GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240.
TO BLOCKING WITH (5) -
8.
THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES, DIAL. BRACE
10d NAILS.
9.
DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS
TRUSSES. IF NEEDED
10.
10d AND 16d NAILS ARE 0.131'X3.0' AND 0.131'X3.5' COMMON WIRE NAILS
HORIZONTAL BRACE
RESPECTIVELY.
(SEE SECTION A -A)
11.
SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12
BY SPIB/ALSC.
MINIMUM STUD
SIZE SPECIES
AND GRADE
STUD
SPACING
WITHOUT
BRACE
2X4
L - BRACE
DIAGONAL
BRACE
(2) DIAGONAL
BRACES AT
1/3 POINTS
MAXIMUM STUD LENGTH
2X4 SP #3 / STUD
12" O.C.
3.8-10
5.6-11
6.6.11
11-1-13
2X4 SP #3 / STUD
1 16" O.C.
3-3-10
4.9.12
6.6-11
9.10.15
2X4 SP #3 / STUD
24" O.C.
2-8.6
3.11-3
5.4-12
8-1-2
2X4 SP #2
12" O.C.
3-10-15
5-6.11
6.6-11
11-8-14
2X4 SP #2
16" O.C.
3-6.11
4-9-12
6-6-11
10.8.0
2X4 SP #2
24" O.C.
3-1-4
3-11-3
1 6-2-9
1 9-3.13
DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE
EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO
BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE
WITH 10d NAILS 6' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER
90% OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2.
END WALL
MAX MEAN ROOF HEIGHT = 30 FEET
EXPOSURE B OR C ----
ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
DURATION OF LOAD INCREASE: 1.60 CONNECTION OF BRACING IS BASED ON MWFRS.
Rama Pranav Kristam, P.E.
# 88906
4451 St, Lucie Blvd, Suite 201
Fort Pierce, FL 34946
FEBRUARY 17, 2017 I T WITH 2X'BRACE ONLY IL I STDTL00
NOTES:
T—BRACING / I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING
IS IMPRACTICAL. T—BRACE / I —BRACE MUST COVER 90% OF WEB LENGTH.
THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TO
CONTINUOUS LATERAL BRACED WEBS.
A•1 ROOF TRUSSES
4451 ST, LUCIE BLVD,
FORT PIERCE, FL 34946
772-409-1010
NAILING PATTERN
T-BRACE SIZE
NAIL SIZE
NAIL SPACING
2X4 OR 2X6 OR 2X6
10d
6" O.C.
NOTE: NAIL ALONG ENTIRE LENGTH OF T—BRACE / I —BRACE (ON
TWO—PLY TRUSSES NAIL TO BOTH PLIES)
NAILS
A
BRACE
SIZE FOR ONE -PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T—BRACE
2X4 I —BRACE
2X6
2X6 T—BRACE
2X6 I —BRACE
2X8
2X8 T—BRACE
2X8 I —BRACE
BRACE
SIZE FOR TWO-PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T—BRACE
2X4 I —BRACE
2X6
2X6 T—BRACE
2X6 I —BRACE
2X8
2X8 T—BRACE
2X8 I —BRACE
T—BRACE / I —BRACE MUST BE SAME SPECIES
AND GRADE (OR BETTER) AS WEB MEMBER.
NAILS
WEB
NAILS
0,011014,2144
NAILS
WEB
"mosm
SECTION DETAILS
Rd Pinu —stem, P.E.
488906
4451 St, Lucie Blvd, Suite 201
Fnd Pi.— FI gAQAA
FEBRUAIY 17, 2017
LATERAL BRACING RECOMMENDATIONS I STDTL10
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
7724109-1010
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
2XG 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET
ALONG A FLOOR TRUSS.
NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE
TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY
OF THE METHODS ILLUSTRATED BELOW.
NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE
BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS
FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY
CONNECTED, BY OTHERS, AT THE ENDS.
USE METAL FRAMING
ANCHOR TO ATTACH
TO TOP CHORD
BLOCKING BEHIND THE VERTICAL
WEB IS RECOMMENDED WHILE
NAILING THE STRONGBACK
INSERT WOOD SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS)
WEB WITH (3) — 10d SCAB WITH (3) — 10d
NAILS (0.131' X 3') NAILS (0.131' X 3'). ATTACH TO VERTICAL
WEB WITH (NAILS (0.313)X X)
USE METAL FRAMING J 4 ATTACH TO VERTICAL
ANCHOR TO ATTACH WEB WITH (3) — 10d
TO BOTTOM CHORD NAILS (0.131' X 3')
ATTACH 2X4 VERTICAL
TO FACE OF TRUSS.
FASTEN TO TOP AND
BOTTOM CHORD WITH
(2) — 10d NAILS (0.131'
X 3') IN EACH CHORD
ATTACH TO VERTICAL
SCAB WITH (3) — 10d
NAILS (0.131' X 3')
TRUSS 2X6 4' — 0' WALL
STRONGBACK (TYPICAL SPLICE) (BY OTHERS)
ATTACH TO CHORD
WITH (2) #12 X 3'
WOOD SCREWS
(0.216' DIA.)
INSERT SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
USE DRYWALL TYPE SCREWS)
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT,
DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' — 0' LONG SCAB
CENTERED ON THE SPLICE AND JOINED WITH (12) — 10d NAILS (0.131' X 3')
EQUALLY SPACED.
ALTERNATE METHOD OF SPLICING:
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' — 0' AND FASTEN WITH (12) —
10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY
WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL).
BLOCKING
(BY OTHERS)
Rama Pranav Kdstam, P.E.
# 88906
4451 St, Lucie Blvd, Suite 201
FEBRUARY 17, 2017 1 LATERAL TOE -NAIL DETAIL I STDTL1 4
A-1 ROOF TRUSSES
4451 ST, LUCIE BLVD,
FORT PIERCE, FL 34946
772409-1010
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN
THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS
SHOWN).
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL
BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO
SPECIES FOR MEMBERS OF DIFFERENT SPECIES.
TOE -NAIL SINGLE SHEAR VALUES
PER NOS 2001 (LB/NAIL)
DIA
SP
OF
HF
SPF
SPF-S
.131
88.0
80.6
69.9
68.4
59.7
o
.135
93.5
85.6
74.2
72.6
63.4
J
.162
108.8
99.6
86.4
84.5
73.8
ri
.128
74.2
67.9
58.9
57.6
50.3
c�
.131
75.9
69.5
60.3
59.0
51.1
Z
0
.148
81.4
74.5
64.6
63.2
52.5
N
ri
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
THIS DETAIL IS ONLY APPLICABLE TO
THE THREE END DETAILS SHOWN BELOW.
VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY.
SIDE VIEW
(2X3) 2 NAILS
-i NEAR SIDE
NEAR SIDE
SIDE VIEW
(2X4) 3 NAILS
EXAMPLE: NEAR SIDE
(3) - 16d NAILS (0.162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD
I NEAR SIDE
FOR LOAD DURATION INCREASE OF 1.15:
3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY NEAR SIDE
ANGLE MAY
VARY FROM
30' TO 60°
45.00'
ANGLE MAY
VARY FROM
30° TO 60°
45.00'
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
NEAR SIDE
ANGLE MAY
VARY FROM
30° TO 60°
45.00°
Rama Pranav Kristam, P.E.
488906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
FEBRUAY 17, 2017 1 UPLIFT TOE -NAIL DETAIL ( STDTL12
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
THIS DETAIL SHALL BE USED FOR A CONNECTION
RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER
IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS.
NOTES:
TOE -NAIL WITHDRAWAL VALUES
PER NOS 2005 (LB/NAIL)
DIA.
SP
OF
HF
SPF
SPF-S
L7
Z
O
J
.131
59
46
32
30
20
.135
60
48
33
30
20
LQ
()
.162
72
58
1 39
1 37
25
J
_
F_
LO
LU
-U
J_
0
Z
Lo
N
.128
54
42
28
27
19
.131
55
43
29
28
19
.148
62
48
34
31
21
Q
Z
14)
.120
51
39
27
26
17
0
Z
O
.128
49
38
26
25
17
131
51
39
27
26
17
O
to
.148
I
57
I
44
I
31
I
28
I
20
r
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30° WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE
MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION.
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0.162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE
FOR WIND DOL OF 1.33:
3 (NAILS) X 37 (LB/NAIL) X 1.33 (DOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
FOR WIND DOL OF 1.60:
3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LEIS (177 LBS) BUILDING
DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION.
ros USE (3) TOE -NAILS ON 2X4 BEARING WALL
ree USE (4) TOE -NAILS ON 2X6 BEARING WALL
NEAR SIDE
FAR S]
110
TOP PLATE
OF WALL
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
1
NAIL
NAIL
SIDE VIEW
Rama Pranav Kristam, P.E.
END VIEW 4451 St. Luce Blvd, Suite 201
Fort Pierce, FL 34946
FEBRUARY 5,2016 1 TYP W NAILER ATTACHMENT I STDTL13 0,
A-1 ROOF TRUSSES
4451 ST . LUCIE SLVD.
FORT PIERCE, FL 34946
772-409-1010
1.0 x z+
A
2x2 NAILER ATTACHMENT
•
MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
Rama Pranav Kristam, P.E.
4451 St. L=, Suite 201
Fort Pierce, FL 34946
April 1 ', 2016 TYPICAL ALTERNATE BRACING DETAIL STDTL14
I FO EXTERIOR FLAT GIRDER TRUSS I
A-1 ROOF TRUSSES
BLVD.
4451 ST. LUCIE
FORT PIERCE, FL 34946
772-409-1010
(4) 12d
TRUSS 2411 O.C.
UPLIFT CONNECTION
(SEE ROOF TRUSS)
12
VARIES
(4) 12d
MAX 3011(21-611)
2x6 #2 SP (Both Faces)
24 It O.C.
SIMPSON H5
Rama Pranav Kristen P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND
FEBRUARY 17, 2017 1 DAMAGED OR MISSING CHORD SPLICE PLATES I STDTL15
A'1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-109-1010
TOTAL NUMBER
OF NAILS EACH
SIDE OF BREAK *
X
(INCHES)
MAXIMUM FORCE (LBS) 15% LOAD DURATION
SP
OF
SPF
HF
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
20
30
24"
1706
2559
1561
2342
1320
1980
1352
2028
26
39
30"
2194
3291
2007
3011
1697
2546
1738
2608
32
48
36"
2681
4022
2454
3681
2074
3111
2125
3187
38
57
42"
3169
4754
2900
4350
2451
3677
2511
3767
44
66
48"
3657
5485
3346
5019
2829
4243
2898
4347
* DIVIDE EQUALLY FRONT AND BACK
ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF
THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE
ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (.131' DIA. X 3').
STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN
THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE.
THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS)
THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X +
TRUSS CONFIGURATION
AND BREAK LOCATIONS
FOR ILLUSTRATIONS ONLY
THE LOCATION OF THE BREAK MUST BE GREATER
THAN OR EQUAL TO
THE REQUIRED X DIMENSION FROM ANY PERIMETER
BREAK DR HEEL JOINT
AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT
(SEE SKETCH ABOVE).
DO NOT USE REPAIR FOR JOINT SPLICES
NOTES:
1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR
DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE
TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN
THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF
SUPPORTING THE LOADS INDICATED.
2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR
AND HELD IN PLACE DURING APPLICATION OF REPAIR.
3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID
UNUSUAL SPLITTING OF THE WOOD.
4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID
LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY.
Rama Pranav Kristam, P.E.
6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS.
488906
4451 St. Lucie Blvd, Suite 201
FEBRUARY 17, 2017 SCAB APPLIED OVERHANGS STDTL16
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-4109.1010
TRUSS CRITERIA:
LOADING: 40-10-0-10
DURATION FACTOR: 1.15
SPACING: 24' D.C.
TOP CHORD: 2X4 OR 2X6
PITCH: 4/12 - 12/12
HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL
END BEARING CONDITION
►�'
1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS
WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148' DIA. X 3') SPACED 6' O.C.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO
AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
2X SC
NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED
WHEN OVERHANG HAS BEEN BROKEN OFF.
Gi'o:_ 1
THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 409 SPACED 24'
O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD
LOADS NOT EXCEEDING 50 PSF.
TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.
REFER TO INDIVIDUAL TRUSS DESIGN
FOR PLATE SIZES AND LUMBER GRADES
Rama Pranav Mstam, P.E.
488906
4451 St. Lucie Blvd, Suite 201