Loading...
HomeMy WebLinkAboutProduct Approval - entry door Business & Professional Regulation �4 SCIS Mame Log In i User Registration j Mot Topics ! Submit Surcharge Stats&Facts Publications Cored Us =S Site Map E units Search �W i Product Approval r (A USER:Public User 13 Product Approval Menu>Product or Application Search>Application List>AppNcation Daull `'1 FL# FL22378-R6 Application Type Revision fi{a Code Version 2017 Y Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago,IL 60185 (800) 663-3667 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 01/25/2019 Date Validated 01/28/2019 Date Pending FBC Approval Date Approved 02/04/2019 ' Summary of Products FL# Model,Number or Name Description 22378.1 Stormguard Fiberglass Side-Hinged 6'-8"Opaque I/S Single Door Door Unit Umlts of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22378 R6 C CAC NI007077.07-R2.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2020 Design Pressure: +60/-6S Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL0170.pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation&Management Institute I where pressure requirements do not exceed the design I Created by Independent Third Party: pressures listed. 3'-0"x 6'-8"max nominal size. Hurricane Evaluation Reports protective system is NOT required. See DWG-MA-FLO170 for ( FL22378 R6 AE 514010A.pdf anchor details and water performance where required. 1 FL22378 R6 AE 514014A.p f Created by Independent Third Party: Yes 22378.2 Stormguard Fiberglass Side-Hinged 6'-8"Opaque O/S Single Door Door Unit Umits of Use Certification Agency Certificate Approved for use in HVHZ:Yes f FL22378 R6 C CAC NI007077.07-R2.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2020 Design Pressure: +60/-60 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL0170.pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 3'-0"x 6'-8" max nominal size. Hurricane Evaluation Reports protective system is NOT required.See DWG-MA-FLO170 for FL22378 R6 AE 514010A.pdf anchor details and water performance where required. FL22378 R6 AE 514014A.pdf Created by Independent Third Party: Yes 22378.3 Stormguard Fiberglass Side-Hinged 6'-8"Opaque I/S Single or Double Door w/or w/o Sidelites Door Unit Umits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22378 R6 C CAC NI007077.07-R2.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2020 Design Pressure. +50.5/-S0.5 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL0170.pdf `I Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation & Management Institute where pressure requirements do not exceed the design 1 Created by Independent Third Party: 1 pressures listed. 12'-0" x 6'-8"max nominal size. Hurricane Evaluation Reports protective system is NOT required. See DWG-MA-FLO170 for FL22378 R6 AE 514008A.pdf anchor details and water performance where required. FL22378 R6 AE 514012A.pdf Created by Independent Third Party: Yes 22378.4 dStormguard Fiberglass Side-Hinged 6'-8"Opaque O/S Single or Double Door w/or w/o Sidelites Door Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22378 R6 C CAC N1007077.07-R2.pdf Approved for use outside HVHZ: Yes I Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2020 Design Pressure: +55.0/-S0.5 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL0170.pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute where pressure requirements do not exceed the design j Created by Independent Third Party: pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane Evaluation Reports protective system is NOT required. See DWG-MA-FLO170 for FL22378 R6 AE 514008A.pdf anchor details and water performance where required. FL22378 R6 AE 514012A.pd Created by Independent Third Party: Yes _— _ - 22378.5 Stormguard Fiberglass Side-Hinged 6'-8"Impact Glazed I/S or O/S Single Door w/or w/o Sidelites Door Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22378 R6 C CAC NI007077.09-R3.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2020 Design Pressure: +55/-SS Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL 0172.pdf Building Code,including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 9'-0"x 6'-8" max nominal size. Hurricane Evaluation Reports protective system is NOT required. See DWG-MA-FLO172 for FL22378 R6 AE 514008A.pdf 1 anchor details and water performance where required. I i FL22378 R6 AE 514012A.pdf Created by Independent Third Party: Yes 22378.6 Stormguard Fiberglass Side-Hinged 6'-8"Impact Glazed I/S Double Door w/or w/o Sidelites Door Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22378 R6 C CAC NI007077.09-R3.pdf 1 Approved for use outside HVHZ: Yes j Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +50/-55 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL 0172.pdf j Building Code,including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size. Hurricane Evaluation Reports protective system is NOT required.See DWG-MA-FLO172 for FL22378 R6 AE 514008A.pdf f anchor details and water performance where required. FL22378 R6 AE 514012A.pdf Created by Independent Third Party:Yes 22378.7 Stormguard Fiberglass Side-Hinged 6'-8"Impact Glazed O/S Double Door w/or w/o Sidelites Door Unit Approved for use to HVHZ:` - ------- --- — _ - - - - - -- ------ - ------------ LimiIts- of Use �Certification Agency Certificate Yes FL22378 R6 C CAC NI007077.09-R3.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +55/-55 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL 0172.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0" x 6'-8"max nominal size. Hurricane Evaluation Reports protective system is NOT required.See DWG-MA-FLO172 for FL22378 R6 AE 514008A.pdf anchor details and water performance where required. FL22378 R6 AE 514012A.pdf Created by Independent Third Party: Yes 22378.8 Stormguard Fiberglass Side-Hinged 8'-0"Opaque I/S Single Door Door Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22378 R6 C CAC NI007077.08 .pdf Approved for use outside HVHZ:Yes !Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +60/-65 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL0171.pdf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design j Created by Independent Third Party: pressures listed. 3'-0"x 8'-0"max nominal size. Hurricane Evaluation Reports protective system is NOT required.See DWG-MA-FLO171 for FL22378 R6 AE 514009A.pdf anchor details and water performance where required. FL22378 R6 AE 514013A.pdf Created by Independent Third Party: Yes - ---- -- - ------- - -- ----.-.---- ------------- 22378.9 --------22378.9 Stormguard Fiberglass Side-Hinged 8'-0"Opaque O/S Single Door Door Unit Limits of Use 'Certification Agency Certificate Approved for use in HVHZ:Yes FL22378 R6 C CAC NI007077.08 .pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +60/-60 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL0171.p�f Building Code,including the High Velocity Hurricane Zone,and i Verified By: National Accreditation &Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 3'-0"x 8'-0"max nominal size. Hurricane Evaluation Reports protective system is NOT required.See DWG-MA-FLO171 for FL22378 R6 AE 514009A.pdf anchor details and water performance where required. FL22378 R6 AE 514013A.pdf Created by Independent Third Party:Yes 22378.10 Stormguard Fiberglass Side-Hinged 8'-0"Opaque I/S Single or Double Door w/or w/o Sidelites Door Unit I Limits of Use I Certiflcatlon Agency Certificate I Approved for use in HVHZ:Yes FL22378 R6 C CAC NI007077.08 .pd Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +50.0/-50.5 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL0171.12df Building Code,including the High Velocity Hurricane Zone,and Verified By: National Accreditation &Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size. Hurricane Evaluation Reports protective system is NOT required.See DWG-MA-FLO171 for FL22378 R6 AE 514007A.pdf anchor details and water performance where required. FL22378 R6 AE 514011A.pdf Created by Independent Third Party: Yes f 22378.11 Stormguard Fiberglass Side-Hinged 8--'--0-"Opaque O/S Single or Double Door w/or w/o Sidelit-s Door Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22378 R6 C CAC NI007077.08 .Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2020 Design Pressure: +55.0/-50.5 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL0171.Ddf Building Code, including the High Velocity Hurricane Zone,and Verified By: National Accreditation&Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane Evaluation Reports protective system is NOT required. See DWG-MA-FLO171 for FL22378 R6 AE 514007A.Ddf anchor details and water performance where required. FL22378 R6 AE 514011A.Ddf Created by Independent Third Party:Yes 22378.12 Stormguard Fiberglass Side-Hinged 8'-0"Impact Glazed I/S Single or Double Door w/or w/o Door Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22378 R6 C CAC NI007077.04-R6.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2020 Design Pressure: +43/-47 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL 0173.pdf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane Evaluation Reports protective system is NOT required. See DWG-MA-FLO173 for FL22378 R6 AE 514007A.pdf anchor details and water performance where required. FL22378 R6 AE 514011A.pdf Created by Independent Third Party: Yes 22378.13 Stormguard Fiberglass Side-Hinged 8'-0"Impact Glazed O/S Single or Double Door w/or w/o Door Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22378 R6 C CAC NI007077.04-R6.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +47/-45 Installation Instructions Other: Evaluated for use in locations adhering to the Florida FL22378 R6 II FL 0173.Ddf Building Code, including the High Velocity Hurricane Zone, and Verified By: National Accreditation &Management Institute where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane Evaluation Reports protective system is NOT required. See DWG-MA-FLO173 for FL22378 R6 AE 514007A.Idf anchor details and water performance where required. FL22378 R6 AE 514011A.p&f Created by Independent Third Party: Yes Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.CoPyyht 2007-2013 State of Florida.::Privacy.Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 4SS,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click herr-, Product Approval Accepts: ME ONE] in F-51;101 E Credit Card Safe ul n1 MASONITE 149'VAX. OVERALL FRAME WIDTH D0 MAX. 00 STORMGUARD FIBERGLASS DOOR UNIT 2 o.L.o PANEL WIDTH 37.5' MAX. O UJ F6'-8"DOUBLE DOOR WITH/WITHOUT SIDEtITES W/ASTRAGAL FRAME WIDTH Q�_I 0 GENERAL NOTE$ 3 U I. EVALUATED FOR USE IN LOCATIONS ADHERING SS ® ® ® ® a Li THE FLORIDA BUILDING CODE AND WHERE PRESSURE _ REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, U DOES NOT EXCEED THE DESIGN PRESSURES LISTED. ._ 2. THIS PRODUCT DOES NOT REQUIRE THE USE OF �o: 0�I. A HURRICANE PROTECTIVE SYSTEM (SHUTTERS). m C .-3 3. PO 3. E CDEVELROPEFLAME SPREAED INDEX OFF 601NDEX ER OF E84. 4. PLASTICS TESTING: TEST DESCRIPTION DESIGNATION FACING LTTE FRAME � SELF IGNITION TEMP ASTM D1929 752 'F > 650 'F 1 842 'F > 650'F RATE OF BURNING ASTM D635 0.56 IN MIN 1.28 IN MIN SMOKE DENSITY ASTM D2843 I 53.4% 70.2% r TENSILE STRENGTH• ASTM 0636 3.2% DIFF 11.8% DIFF 5. PLASTICS TESTING OF WORLDWIDE COMPOSITE FRAME (WHERE USED): TEST DESCRIPTION DESIGNATION RESULT SELF IGNITION TEMP ASTM D1929 779 -F > 650 -F tl RATE OF BURNING ASTM D635 0.0 IN MM SMOKE DENST/Y ASTM D2843 39.0% TENSILE STRENGTH* ASTM D638 3.6% DIFF AObdm bMAY 0 • COMPARATIVE TENSILE STRENGTH AFTER WEATHERING k DOUBLE DOOR UNIT W/SID£LITES fL � 4500 HOURS XENON ARC METHOD 1 40 3 3 3 m V1 to LA(n V1 130 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1313 ❑ ❑ N .00 00 00 00. .00 00. 00 -00o . UnIx 00 00 00 00 0 00a00a 0x OOOUV to gg>« SINGLE DOOR UNIT DOUBLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT WISlDEL1T DOUBLE DOOR UNIT W/SIDELITE$ WfTH SIDELITE WITH 04 N fV p O STRUCTURAL WHERE WATERINFILTRATION PERFORMANCE DESIGN PRESSURE RATING REQUIRED TO BE 15X OF DESIGN PRESSURE C0NnC MAX WIDTH INNING ALL OUTSWING INSWING BUM I 0 M S 4 HIGH DAM X + - + - A +25 -25.0 + - +50. - + - + - woc>m<0 XX 4 + - + - N A + .0 +4 . A + + .0 XorX 171 + - +024--- 5.0 - NA + . -25.0 +40. NA + . + . OX 11 + - t - NA + 5.0 --B-.T- +40. -40. N A + - + - uuE j9/07 XX 1 + - + -50.5 + - + -40. A + - + i - ✓ s AE-. N.T.S. TABLE OF CONTENTS i•� DIQ er. SWS SHEEP DESCRIPTION cWL BY: KURT BALTHAZOR ORIYMNO NO.: T TYPICAL ELEVATIONS & GENERAL NOTES FLORIDA P.E. 2 ANCHORING LOCATIONS & DETAILS /56533 OWG-MA-F10170-07 3 ANCHORIN L NS & AILSr Q: oo s" SEE DETNL s' 3" Q 3- 3' 3• 3 J _1 3' 3' � rk6. �._ I 11 1II I � cnp OU io m . . Q. n _ 3' _ � r; u U n p n— L0 a SEE DETAIL — — 3 1ai1 "D' SEE DETAIL.C. — A _ SEE DETNL _ B W c.e H 6• — v ~ G)— _ 6 3' 3'-4 _ 3 _ I 3" 3' 3' 3' 3' 6'— �- 6" QpL g• a Ii SEE DETAIL6' #8 x 2" N 3 N ASTRAGAL RETAINER BOLT HOLE rn )X )rn #8 x 2" #10 x 5/8" MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE v� STRUCTURE DEEP ENOUGH Q #8 x 2" #10 x 5/8" FOR A 1.375" THROW #10 x I" DETAIL "E" ASTRAGAL a a to (L oI z L = p #10 x 2-1/2" ATTACH ASTRAGAL RETAINER BOLT DETAIL "F" ASTRAGAo 0 oz, 0 #10 x I" STRIKE PLATE TO FRAME r� nM1N o N #10 x 5/8" AS SHOWN. 0 DETAIL "C" D DETAIL "D" 1 W 1C-4 C4 www m1w Nwu1m auo r Nmutm au. ofa 1.375 T r••�"�',, 1.437' n,tr ew snoimom '1—�r�'7 xca.mt Nott mwonm m va.ter (or o.ao"wtn/1ta.,a,m1.1,) >tarK) o.a.o•swlot pa,s-17x1.11) (arit7rN) TQiw,w stttolNw m i .NM•me. 0.1w mm sawmaaOm lmw 1w. NmL IaK pt WW W*= 1/Y NR N111L.far.m VM DART 1/f NR O U m Q Z INSWING THRESHOLD BUMPER 0/S THRESHOLD HP 0/S THRESHOLD 1 1 wr Na ?; `? oor ON .a m 41;{"? ow m DATE 4 9 07 41 scmf-: N.T.S. 1.482' 1.75' 1.047' 1.437' �� �� y�� �� owe.x, SWS T TYPICAL GWING DETAIL ALTERNATE GLAZING DETAIL T TIMPACT RATED Cr.sc au.er: 177P�7 RATED CLASS - - DIOo71tq N0.: -SERIES 0/S THRESHOLD HIGH DAM OjS THRESHOLD T4 0/S THRESHOLD 1» -U#-"lM-o7 s7lFfr -a SEE DETAIL 3' 6' 6' Q 'E" SHT. 2 3' 3' 3_ r 3rk O(O I 6" 6"�7 �—6• 6'� 1 I I I J �n O . M o a U W B 'c DL DETAIL F- U7 U 'D' SHT. 2 �V) LLJ SEE DETAIL w •C" SHT. 2 A � B n 0 vi 6' ' 6' 612° t0 I I I I I I 1 1 I I I 3' 3' I 4t ""1 g• 3' IIY�in1DMIN SEE DETAIL 3^ 6 3 3.6. ' o p 'F' SHT. 2 6. fl•YMdA I R iL HARDWARE SCHEDULE ATTACHMENT DETAIL 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND N v)v) � SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, AT 5-1/2" CENTERLINE. SIGNED AND SEALED BY ROBERTO LOMAS, PEw 1.25' 2. 4" X 4" FULL MORTISE BUTT HINGES. (FLORIDA #62514) WITH THE LOWEST (LEAST) MINI • 1 FASTENER RATING FROM THE DIFFERENT FASTENERS ` inz" 1•X1/2" CORRUGATED /toX2• WOOD SCREW aarw BEING CONSIDERED FOR USE. JAMB, HEAD, AND HIM 3' FROM EACH END 6• FROM EACH END a a o En 1.25" :'� AND 7' OC AND 12. OC x r N�a z THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE CL--IF;t MIN #10 WOOD SCREWS, 1/4" TAPCONS, AND #10 TEK SCREWS. 0.25" w w och A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH SHIM CfW �S QID Lo ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". CAULK WOOD SCREW EDGE DISTANCE MIN 3/4". TEK SCREW EDGE TYPICAL MASONRY CL �` ACRYLIC + o DISTANCE MIN 1/2". ANCHOR INSTALLATION '.tRi LAT CL ^m CN CA Cq N 2. ANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TO 1X BUCK MASONRY COMBINATION WOOD COMBINATION WOOD o� ACHIEVE 3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE. '•' * ANCHOR INSTALLATION MULLION (BOXED) MULLION (BOXED) 1.50'T-- ) 3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM MIN L— '-iM (34gl S2- 2' (4) 110X21 2' w�c�m<Z ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT EACH END EACH END OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE cL—� wre 4 9 07 MINIMUM EMBEDMENT OF 1-1/4". • srxe N.T.S. 4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO DW.9f. SWS TRANSFER LOADS TO STRUCTURE. TYPICAL WOOD BUCK • • •• f1°` f: DPAWM NOF ANCHOR INSTALLATION 5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. INTEGRAL WOOD INTEGRAL WW DM-M-MA-Fi.o17a07 MULLION (CHS) MULLION (CHS)