Loading...
HomeMy WebLinkAboutDesign Certification for Wind Load ComplianceSt. Lucie County Building and Zoning Department 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-1553 Design Certification for Wind Load Compliance This Certification is to be completed by the project desigfi�Fchitect or engineer. This Certification must be submitted with all applications for building permits involving the codsiruction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior denovations (provided that no structural walls, columns or other similar component is being effected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at 462-1553 or 462-2172. Project Name Seu F ler i a- Office Use Onl Street Address ft« dts rernrn.'Mwa Permit Number 9 e a t Lj a Rck Occu ane Type o-eS4.latel iRL 11912 Construction Ty2e Certification Statement: I certify that, to the best of my knowledge and belief, these pl an ciflca ns have been designed to comply with the applicable structural portion of the Buil s c tly adopted and enforced by St. Lucie County. I also certify that structural elements depicted o provide adequate resistance to the wind loads and forces specified by current code provisions. ©©©©©© Design Parameters and Assumptions Used: (Please check or complete the appropriate box.) 1. Florida Building Code 2004 Edition _ ASCE 7-98 Y 2. Building Design is (check one) Enclosed Partially Enclosed Open Building^ 3. Building Height: 115 FT 4. Wind Speed Used in Building Design: 130 3 second gust 5. Wind Exposure Classification (refer to exposure tables in Building Code identified in Line #1): G 6. Average Wind Velocity Pressure on Exterior Faces of Structure Al jA ,PSF 7. Peak Wind Velocity Pressure on Exterior Faces of Structure 0/A PSF 8. Importance/Use Factor (obtain from Building Code): 1,0 GAT84olR-f M 9. Loads: Floor N A PSF Roof/dead ! A PSF Roof/live tJ A PSF 10. Were Shear Walls Considered for Structure (check one): Yes u/A No if No, attach explanation) 11. Is a Continuous Load Path Provided (check one): Yes _) No (if No, attach explanation) 12. Are Component and Cladding Detail Provided (check one): Yes M A No _(if No, attach explanation) 13. Minimum Soil Bearing Pressure: l3 4 b PSF As witnessed by my seal, I hereby certify that the information included with this certification is true and, correct, to the best of my knowledge and belief. Name: S.M. t4AE SM AK i- r eiiz Certification #: 3 S 8 67 ISeai e]L Design Firm: S.M. "AeeM AkliveK Date: -1- Z 1- 0 8 SLCCDV Form # 020-60 rev. 1015105 ding _. -