HomeMy WebLinkAboutCompaction testHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
July 20, 2020 KSM JOB # :203291-1d/DJ/ct
CONTRACTOR:Lucas Construction
455 3rd Lane SW
Vero Beach, Florida 32962
JOB LOCATION:9473 Meadowood Drive
Ft. Pierce, Florida
PERMIT #:2005-0662
To Whom it may concern,
Should you have any question, please feel free to contact our office.
Respectfully,
Bryan E. Dahlke, P.E.
V.P. of Engineering
PE # 81439 07/20/20
Email to: lucascompanies@aol.com
Proudly Serving Florida since 1990
Enclosed, please find the nuclear density test results performed on the compacted foundation fill at the above
referenced project.
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
DATE TESTED:KSM JOB # :203291-1d/DJ/ct
PERMIT #:2005-0662 NUC #404
CONTRACTOR:Lucas Construction Nuc Model:MC-1 Elite
JOB LOCATION:9473 Meadowood Drive Nuc Serial #:31404
Ft. Pierce, Florida
ITEM TESTED:Compacted Foundation Fill
TEST LOCATION
OF SAMPLE DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F.)
PERCENT
COMPACTION
1. N.E.0" - 12"40+108.7 110.1 98.7%
2. S.E.""109.4 "99.4%
3. Center ""107.2 "97.4%
4. S.W.""106.4 "96.6%
5. N.W.""108.2 "98.3%
Soil Description:
Brown Sand with
Traces of Shell Fragments
In Place Moisture:
15.3%
Proctor Optimum Moisture:
12.0%
Proctor Max. Dry Density: P.C.F.
110.1
@ Test Locations the Density &
Penetrometer reading indicate the
Degree of Compaction Meets
Minimum Requirement
for Unstaked Foundation
Bryan E. Dahlke, P.E.
V.P. of Engineering
PE # 81439 7/20/2020
Proudly Serving Florida since 1990
Disclaimer:Contractor is responsible to maintain
the tested area in the condition that KSM
completed the indicated passed compaction test.
KSM is not responsible if the tested area has been
altered from the approved inspected condition.
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
July 17, 2020
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
DATE TESTED:KSM JOB # :203291-1d/DJ/ct
PERMIT #:2005-0662
CONTRACTOR:Lucas Construction
JOB LOCATION:9473 Meadowood Drive
Ft. Pierce, Florida
Soil Description:
Brown Sand with
Traces of Shell Fragments
Proctor Optimum Moisture:
12.0%
Proctor Max. Dry Density: P.C.F.
110.1
Bryan E. Dahlke, P.E.
V.P. of Engineering
PE # 81439 7/20/2020
SOIL COMPACTION REPORT
ASTM D 1557
July 17, 2020
Proudly Serving Florida since 1990
105.0
106.0
107.0
108.0
109.0
110.0
111.0
7 8 9 10 11 12 13 14 15
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y
Moisture -% of Dry Weight