HomeMy WebLinkAboutStructural Analysis ReportPAUL J. FORD AND COMPANY
STR UCT URAL ENGI NEERS
250 East Broad Street • Suite 1500 • Columbus, Ohio 43215
STRUCTURAL ANALYSIS REPORT
PJF Project No.: 68412-0073
Structure:
Existing 195-ft Self -Supporting Tower
Manufacturer:
World Tower
Year of Mfr:
2008
Location:
Port St. Lucie, Florida
Site Name:
South Florida Recycles
Site Number:
68828
Prepared For:
Verizon Wireless
14055 Riveredge Drive, Suite 600
Tampa, FL 33637
c/o Foresite Group
Attn: Hugh Reilly
November 9, 2012
Analyzed by:
Charles J. Weir, E.I.
Structural Engineer
cweir@pjfweb.com
AN IRFZ
No. 57077 \t
ATE �\
.O'. f
COLUMBUS, OHIO ORLANDO, FLORIDA ATLANTA, GEORGIA
(614) 221-6679 (407) 898-9039 (404) 266-2407
Founded in 1965 www.pifweb.com ' Employee owned since 1994
PAUL J. FORD AND COMPANY
STR UCTURAL ENGINEERS
250 East Broad Street ; Suite 1500 • Columbus, Ohio 43215
Executive Summary
Page 2 of 5
November 9, 2012
PJF# 68412-0073
Port St. Lucie, Florida
Verizon Wireless
South Florida Recycles
68828
Design Standard:
The structural analysis was performed for this tower in accordance with the 2010 Florida Building
Code based upon an ultimate 3-second wind gust speed of 154 mph converted to a nominal 3-second
gust wind speed of 121 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per
Exception #5 of Section 1609.1.1. Exposure Category C and Risk Category II, and a topographic
category of 1 with a crest height of 0 feet were used in this analysis.
Antenna Loads:
The existing 195-ft self-supporting tower was analyzed for the following antenna and coax loading:
zSYatus„ r ,
t%Elev ,
AAntennakx x ,gin ..,�,,. , r., ate, ,u.gr . r..
Coaic�'
Existing
183
1 (6) BSA-185090/12
(6) 1-5/8
Proposed
183
1 (3) X7-665-4
(6) 1-5/8
Stresses:
When the existing tower is analyzed in accordance with the above mentioned code requirements to
support the proposed antenna load it is stressed to 58.1 % of its safe capacity. The tower meets the
minimum code requirements as it now stands.
Existing Foundations:
We were not able to calculate the capacity of the existing foundations without a site -specific
geotechnical report. However, the foundation loads indicated in our structural analysis are less than
the design reactions noted on the original drawings. If the existing foundations were properly
designed and constructed when the tower was originally constructed then they should be adequate to
support the revised foundation loads indicated in our structural analysis.
PAUL J. FORD AND COMPANY
S T R U C T U R A L E N G I N E E R S
250 East Broad Street • Suite 1500 • Columbus, Ohio 43215
Page 3 of 5
November 9, 2012
PJF# 68412-0073
Port St. Lucie, Florida
Verizon Wireless
South Florida Recycles
68828
Tower History:
The South Florida Recycles tower was originally designed and manufactured by World Tower in
2008. This model WSST self-supporting tower is World Tower job number Q07858. Paul J. Ford and
Company was supplied with the original tower and foundation design drawings.
The 195-ft self-supporting tower was originally designed in accordance with Telecommunications
Industry Association Standard ANSI/TIA-222-G for 130 mph 3-second gust of wind without ice.
Project Description:
Verizon Wireless has asked Paul J. Ford and Company to provide a structural analysis of the existing
195-ft self-supporting tower located in Port St. Lucie, Florida. In this analysis, we considered the
addition of (3) new X7-665-4 antenna at an elevation of 183-ft. The new antenna are fed with (6) new
1-5/8" coax.
Proposed Antenna and Feedline Loading:
Our structural analysis was completed considering the following antenna and feedline loading:
y
���atus � „z
' Elev�
'' 11
t Aiitenna�:,
Existing
183
1 (6) BSA-185090/12
(6) 1-5/8"
Proposed
183
1 (3) X7-665-4
(6) 1-5/8"
Note: The antenna feedlines are assumed to be placed as indicated on page 1 of the attached tower sketches.
Structural Analysis:
Our structural analysis of this tower was completed according to the recommendations of the
"Structural Standards for Steel Antenna Towers and Antenna Supporting Structures", ANSI/TIA-222-G.
This standard recommends that the tower be designed for a minimum 121 mph 3-second gust of wind
(at 33 ft above grade) for St. Lucie County. The self-supporting tower was analyzed as a three-
dimensional space truss using finite element software.
PAUL J. FORD AND COMPANY
S T R U C T U R A L E N G I N E E R S
250 East Broad Street • Suite 1500 • Columbus, Ohio 43215
Page 4 of 5
November 9, 2012
PJF# 68412-0073
Port St. Lucie, Florida
Verizon Wireless
South Florida Recycles
68828
Results:
Our structural analysis of the existing South Florida Recycles tower indicates that the diagonal
connection bolts from elevations 0-ft to 20-ft are stressed to 58.1 % of their safe capacity. These are
the structural components that control the capacity of the tower.
We were not able to calculate the capacity of the existing foundations without a site -specific
geotechnical report, however, the original foundation loads are indicated on the existing drawings. A
comparison of these loads follows:
Re, h `t
i3R.. e`,Reons;Py
Uplift (k)
609
277.1
45.50%
Compression (k)
697
334.7
48.02%
Base Shear (k)
120
65.3
54.42%
Overturning Moment (k-ft)
12689
6035.3
47.56%
Conclusion:
Paul J. Ford and Company performed a structural analysis of the existing South FLorida Recycles tower
in accordance with the Telecommunications Industry Association Standard ANSI/TIA-222-G. Our
analysis indicates that the tower is adequate as it now stands to safely support the proposed antenna
loading without the need for any modifications.
We were not able to calculate the capacity of the existing foundations without a site -specific
geotechnical report. However, the foundation loads indicated in our structural analysis are less than
the design reactions noted on the original drawings. If the existing foundations were properly
designed and constructed when the tower was originally constructed then they should be adequate to
support the revised foundation loads indicated in our structural analysis.
We hope that this analysis satisfies your current needs. If you have any questions concerning our
analysis, or if we can be of further service to you, please feel free to contact us at (614) 221-6679.
Sincerely,
PAUL J. FORD AND COMPANY
C rles eir, .I.
ruct al Engineer
Page 5 of 5
PAUL J. FORD AND COMPANY November9, 2012
STR UCT URAL ENGI NEERS PJF# 68412-0073
250 East Broad Street • Suite 1500 • Columbus, Ohio 43215 Port St. Lucie, Florida
Verizon Wireless
South Florida Recycles
68828
STANDARD CONDITIONS FOR FURNISHING OF PROFESSIONAL ENGINEERING SERVICES ON
EXISTING STRUCTURES BY PAUL J. FORD AND COMPANY
1) Paul J. Ford and Company has not performed a site visit to verify the tower member sizes or
the antenna/coax loading. We were provided with the original tower manufacturers drawings.
If the existing conditions are not as represented on these drawings, we should be contacted
immediately to evaluate the significance of the deviation.
2) No allowance was made for any damaged, missing, or rusted members. The analysis of this
tower assumes that no physical deterioration has occurred in any of the structural components
of the tower and that all the tower members have the same load carrying capacity as the day
the tower was erected.
3) It is not possible to have all the very detailed information to perform a very thorough analysis
of every structural sub -component of an existing tower. The structural analysis by Paul J. Ford
and Company verifies the adequacy of the main structural members of the tower. Paul J. Ford
and Company provides a limited scope of service, in that we cannot verify the adequacy of
every weld, plate connection detail, etc.
4) The structural integrity of the existing tower foundation can only be verified if exact soil
conditions are known. Paul J. Ford and Company will not accept any responsibility for the
adequacy of the existing foundations unless a soils report is provided.
5) This tower has been analyzed according to the minimum design wind loads recommended by
the Telecommunications Industry Association Standard ANSI/TIA-222-G. If the owner or local
or state agencies require a higher design wind load, Paul J. Ford and Company should be
made aware of this requirement.
6) The attached sketches are a schematic representation of the tower that we have analyzed. If
any material is fabricated from these sketches, the contractor shall be responsible for field
verifying the existing conditions and for the proper fit and clearance in the field.
7) Miscellaneous items such as antenna mounts etc. have not been designed or detailed as a part
of our work. We recommend that material of adequate size and strength be purchased from a
reputable tower manufacturer.
NII
IyI�
Im
a
olo
o
i
ml
I
ml
e
e
N
I
N�
iE
iX
m
C
N
S
®2
to
N
I
R
I®
a
A
ry
Fn
m
d
z
1
C
F
M
r
x
e
n
L
e
m
I e
of
I.m
W
m
0
0
�jx°
a3
195.0 A
1810 ft
160.0 It
120.0 n
100.01t
Go0ft
40.0 fi
We
FAI
DESIGNED APPURTENANCE LOADING
TYPE
I ELEVATION
I TYPE
ELEVATION
1(2)BM-1850SW12-2w/Mount Pipe
183
1(2)BS U5090n2R wl Mount Pipe
1183
1 X1665 w/Mount Pipe
18]
%1685�w/Mount Pipe
183
_
IO2 BSA-18509V12-2 wl Mount Pipe
1183
Sent. Freme(3)
___
183
1X]66SIw/MomM1Pipa
I 18]
MATERIAL STRENGTH
GRADE Fy Fu GRADE Fy Fu
A572-50 50 w 165 MI IA36 36 MI sakul
TOWER DESIGN NOTES
1. Tower is located in Saint Lucie County, Florida.
2. Tower designed for Exposure C to the TIA-222-G Standard.
3. Tower designed for a 121 mph basic wind in accordance with the TIA-222-G Standard.
4. Deflections are based upon a 60 mph wind.
S. Tower Structure Class II.
6. Topographic Category 1 with Crest Height of 0.00 If
7. TOWER RATING: 58.1%
ALL REACTIONS
AREFACTORED
MAX CORNER REACTIONS ATBASE:
DOWN: 334712/b
SHEAR: 39149/b
UPLIFT:-2771241b
SHEAR: 33114 lb
AXIAL
638281b
SHEAR � \ MOMENT
65324 /b ` 60352681bft
TORQUE 14720lb-ft
REACTIONS -121 mph WIND
Paul J Ford and Company
250 E. Broad Street Suite 1500
Columbus, OH 43215
Phone: 614.221.6679
FAX: 614.448.4105
o0' Exis6n 195-ft SST, Port St Lucie, FL
Project 68412-0073
L°ebb Foresite roup
Weir
Apptli
Coee' TIA-222-G
,0m"nbYChades
ele:l l/09/12
$C81B' NTS
PatM1.
ew'0 No. E-1
Feedline Plan
20'
Routs Flel APPIn Few App OW Face
Paul J Ford and Company
250 E. Broad Street Suite 1500
COlumbus, OH 43215
Phone: 614.221.6679
FAX: 614.448.4105
ob'E dq 195-ft SST; Port St Lucie, FL
PmjeQ 66412-0073
cl"rn Foresile Group
0!!nhades Weir
APp'd;
code' TIA-222-G
D81p 11/0f-s
9/12
5-T1 : NTS
Pe :
D g No. E-7
-
tnxTower
Job
Page
Existing 195-ft SST; Port St. Lucie, FL
1 of 17
Paul J Ford and Company
Project
Date
250 E. Broad Street Suite 1500
69412-0073
15:21:55 11 /09/12
Columbus, OH43215
Client
Designed by
Phone: 614.221.6679
Foresite Group
Charles Weir
FAX 614.448.4105
Tower Input Data
The main tower is a 3x free standing tower with an overall height of 195.00 ft above the ground line.
The base of the tower is set at an elevation of 0.00 ft above the ground line.
The face width of the tower is 4.00 ft at the top and 22.00 ft at the base.
This tower is designed using the TIA-222-G standard.
The following design criteria apply:
Tower is located in Saint Lucie County, Florida.
Basic wind speed of 121 mph.
Structure Class II.
Exposure Category C.
Topographic Category 1.
Crest Height 0.00 ft.
Deflections calculated using a wind speed of 60 mph.
A non -linear (P-delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in tower member design is 1.
Consider Moments - Legs
Consider Moments - Horizontals
Consider Moments - Diagonals
Use Moment Magnification
Use Code Stress Ratios
Use Code Safety Factors - Guys
Escalate Ice
Always Use Max Kz
Use Special Wind Profile
Include Bolts In Member Capacity
Leg Bolts Are At Top Of Section
Secondary Horizontal Braces Leg
Use Diamond Inner Bracing (4 Sided)
Add IBC .6D+W Combination
. Options
Distribute Leg Loads As Uniform
Assume Legs Pinned
Assume Rigid Index Plate
Use Clear Spans For Wind Area
Use Clear Spans For KL/r
Retension Guys To Initial Tension
Bypass Mast Stability Checks
Use Azimuth Dish Coefficients
Project Wind Area ofAppurt.
Autocalc Torque Arm Areas
SR Members Have Curt Ends
Sort Capacity Reports By Component
Triangulate Diamond Inner Bracing
Treat Feedline Bundles As Cylinder
Use ASCE 10 X-Brace Ly Rules
4
Calculate Redundant Bracing Forces
Ignore Redundant Members in FEA
SR Leg Bolts Resist Compression
All Leg Panels Have Same Allowable
Offset Girt At Foundation
Consider Feedline Torque
Include Angle Block Shear Check
f
Include Shear -Torsion Interaction
Always Use Sub -Critical Flow
Use Top Mourned Sockets
Wnd 180
e eaA
Wed 90
B
Lem Z �9
Face e
Wind Normal
Triangular Tower
tnxTower
Job
Page
Existing 195-ft SST; Port St. Lucie, FL
2 of 17
Project
Date
Paul J Ford and Company
250 E. Broad Streel Suite 1500
68412-0073
15:21:55 11/09/12
Columbus, OH43215
Client
Designed by
Phone: 614.221.6679
Foresite Group
Charles Weir
FAX: 614.448.4105
Tower Section Geometry
Tower Tower Assembly Description Section Number Section
Section Elevation Database Width of Length
Sections
TI
195.00-180.00
4.00
1
15.00
T2
180.00-160.00
4.00
`1
20.00
T3
160.00-140.00
6.00
1
20.00
T4
140.00-120.00
8.00
1
20.00
T5
120.00-100.00
10.00
1
20.00
T6
100.00-80.00
12.00
1
20.00
T7
80,00-60.00
14.00
1
20.00
T8
60.00-40.00
16.00
1
20.00
T9
40.00-20.00
18.00
1
20.00
T10
20.00-0.00
20.00
1
20.00
Tower Section Geometry (cont'd)
Tower
Tower
Diagonal
Bracing
Has
Has
Top Girt
Bottom Girt
Section
Elevation
Spacing
Type
KBrace
Horizontals
Offset
Offset
End
ft
ft
Panels
in
in
Tl
195.00-180.00
3.00
KBrace Left
No
Yes
0.000
0.000
T2
180.00-160.00
5.00
XBrace
No
No
0.000
0.000
T3
160.00-140.00
5.00
XBrace
No
No
0.000
0.000
T4
140.00.120.00
5.00
XBrace
No
No
0.000
0.000
TS
120.00-100.00
10.00
XBrace
No
Yes
0.000
0.000
T6
100.00-80.00
10.00
X Brace
No
Yes
0.000
0.000
T7
80.00-60.00
10.00
X Brace
No
Yes
0.000
0.000
T8
60.00-40.00
10.00
X Brace
No
Yes
0.000
0.000
T9
40.00-20.00
10.00
XBrace
No
Yes
0.000
0.000
T10
20.00-0.00
10.00
XBrace
No
Yes
0.000
0.000
Tower'Section Geometry (cont'd)
Tower
Leg
Leg
Leg
Diagonal
Diagonal
Diagonal
Elevation
Type
Size
Grade
Type
Size
Grade
n
Tl 195.00-180.00
Solid Round
1 1/2" solid
A572-50
Solid Round
1 1/4" solid
A572-50
(50 ksi)
(50 ksi)
T2 180.00-160.00
Solid Round
2 1/4" solid
A572-50
Equal Angle
L 2.5 x 2.5 x 3/16
A36
(50 ksi)
(36 ksi)
T3 160.00-140.00
Solid Round
3" solid
A572.50
Equal Angle
L 2.5 x 2.5 x 3/16
A36
(50 ksi)
(36 ksi)
T4 140.00-120.00
Solid Round
3 1/4" solid
A572-50
Equal Angle
L 2.5 x 2.5 x 1/4
A36
(50 ksi)
(36 ksi)
T5 120.00-100.00
Solid Round
3 3/4" solid
A572-50
Equal Angle
L 3.5 x 3.5 x 1/4
A36
(50 ksi)
(36 ksi)
T6 100.00-80.00
Solid Round
4" solid
A572-50
Equal Angle
L 3.5 x 3.5 x 1/4
A36
(50 ksi)
(36 ksi)
T7 80.00-60.00
Solid Round
4 1/2" solid
A572-50
Equal Angle
L 4 x 4 x 1/4
A36
(50 ksi)
(36 ksi)
T8 60.00-40.00
Solid Round
4 1/2" solid
A572-50
Equal Angle
L 4 x 4 x 5116
A36
(50 ksi)
(36 ksi)
T9 40.00-20.00
Solid Round
4 3/4" solid
A572-50
Equal Angle
L 4 x 4 x 3/8
A36
(50 ksi)
(36 ksi)
T1020.00-0.00
Solid Round
5" solid
A572-50
Equal Angle
L 5 x 5 x 5/16
A36
(50 ksi)
(36 ksi)
Mx owes
Job
Existing 195-ft SST; Port St. Lucie, FL
Page
3 of 17
Project
68412-0073
Date
15:21:5511109/12
Paul J Ford and Company
250E.Broad Street Suite1500
Columbus, OH43275
Client
Designed by
Phone: 614.221.6679
FAX.., 614.448.4105
Foresite Group
Charles Weir
Tower Section Geometry (cont'd)
Tower
Top Girt
Top Girt
Top Girt
Bottom Girt Bottom Girt
Bottom Girt
Elevation
Type
Size
Grade
Type Size
Grade
R
Tl 195.00-180.00
Solid Round
1" solid
A572-50
Solid Round
A572-50
(50 ksi)
(50 ksi)
T2 180.00-160.00
Equal Angle
L 2.5 x 2.5 x 3/16
A36
Solid Round
A36
(36 ksi)
(36 ksi)
Tower Section Geometry (cont'd)
Tower No.
Mid Girt
Mid Girt Mid Girt
Horizontal
Horizontal Horizontal
Elevation of
Type
Size Grade
Type
Size Grade
Mid
ft Girls
T1195.00-180.00 None
Flat Bar
A36
Solid Round
1" solid A572-50
(36 ksi)
(50 ksi)
Tower Section. Geometry cont'd
Tower
Secondary
Secondary Horizontal
Secondary
Inner Bracing
Inner Bracing Size Inner Bracing
Elevation
Horizontal Type
Size
Horizontal
Type
Grade
Grade
ft
T5 120.00-100.00
Equal Angle
L 2.5 x 2.5 x 3/16
A36
Solid Round
A572-50
(36 ksi)
(50 ksi)
T6 100.00-80.00
Equal Angle
L 2.5 x 2.5 x 3/16
A36
Solid Round
A572-50
(36 ksi)
(50 ksi)
T7 80.00-60.00
Equal Angle
L 3 x 3 x 1/4
A36
Solid Round
A572-50
(36 ksi)
(50 ksi)
T8 60.00-40.00
Equal Angle
L 3 x 3 x 1/4
A36
Solid Round
A572-50
(36 ksi)
(50 ksi)
T9 40.00-20.00
Equal Angle
L 3.5 x 3.5 x 1/4
A36
Solid Round
A572-50
(36 ksi)
(50 ksi)
T1020.00-0.00
Equal Angle
L 3.5 x 3.5 x 1/4
A36
Solid Round
A572-50
(36 ksi)
(50 ksi)
Tower Section Geometry (cont'd)
Tower
Gusset
Gusset
Gusset Grade Adjust. Factor
Adjust.
Weight Mult.
Double Angle
Double Angle
Elevation
Area
Thickness
Af
Factor
Stitch Bolt
Stitch Bolt
(perface)
A,
Spacing
Spacing
Diagonals
Horizontals
ft
ft'
in
in
in
Tl
0.00
0.000
A36
1
1
1
36.000
36.000
195.00-180.00
(36 ksi)
T2
0.00
0.380
A36
1
1
1
36.000
36.000
180.00-160.00
(36 ksi)
T3
0.00
0.380
A36
1
1
1
36.000
36.000
160.00-140.00
(36 ksi)
T4
0.00
0.380
A36
1
1
1
36.000
36.000
140.00-120.00
(36 ksi)
T5
0.00
0.500
A36
I
1
1
36.000
36.000
120.00-100.00
(36 ksi)
T6
0.00
0.500
A36
1
1
1
36.000
36.000
100.00-80.00
(36 ksi)
MAP
Job
PageOwer
Existing 195-ft SST; Port St. Lucie, FL
4 of 17
Paul J Ford and Company
Project
Date
250 E. Broad Street Suite 1500
68412-0073
15:21:55 11/09/12
Columbus, OH43215
Client
Designed by
Phone: 614.221.6679
Foresite Group -
Charles Weir
FAX 614.448.4105
Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weighi Mult. Double Angle Double Angle
Elevation Area Thickness Alf Factor Stitch Bolt Stitch Bolt
(perface) A, Spacing Spacing
Diagonals Hortzontals
it it, in in in
T7 80.00-60.00
0.00
0.500
A36 1 1 1 36.000
36.000
(36 ksi)
T8 60.0040.00
0.00
0.500
A36 1 1 1 36.000
36.000
(36 ksi)
T9 40.00-20.00
0.00
0.500
A36 1 1 1 36.000
36.000
(36 ksi)
T1020.00-0.00
0.00
0.500
A36 1 1 1 36.000
36.000
(36 ksi)
Tower Section Geometry (cont'd)
KFactors
Tower
Calc
Calc
Legs X K Single Girts Hartz.
Sec. Inner
Elevation
K
K
Brace Brace Diags
Horiz. Brace
Single
Solid
Diags Diags
Angles
Rounds
X X X X X
X X
Tl
No
Yes
1
1
I
1
1
1
1
1
195.00-180.00
1
I
1
I
1
1
1
T2
Yes
No
1
1
I
1
1
1
1
1
180.00-160.00
1
1
1
1
1
1
1
T3
Yes
No
1
I
I
1
I
1
1
1
160.00-140.00
1
1
1
I
1
1
1
T4
Yes
No
1
1
1
1
1
1
1
1
140.00-120.00
1
1
1
1
1
1
1
TS
No
No
I
1
1
1
1
1
0.5
1
120.00-100.00
1
1
1
1
1
0.5
1
T6
No
No
1
1
1
1
1
1
0.5
1
100.00-80.00
1
I
1
1
1
0.5
1
T7
No
No
1
1
l
1
1
1
0.5
1
80.00-60.00
I
1
1
1
1
0.5
1
T8
No
No
1
1
1
1
1
1
0.5
I
60.00-40.00
1
1
1
1
1
0.5
1
T9
No
No
1
1
1
1
1
I
0.5
1
40.00-20.00
1
I
1
1
1
0.5
1
T10
No
No
I
1
1
1
1
1
0.5
1
20.00-0.00
1
1
1
1
1
0.5
1
to
the
Tower Section G
the Kfactor in the out -of -plane direction applied to
Tower
Elevation
ft
Leg
Diagonal
Top Girt
Bottom Girt
Mid Girl
Long Horizontal
Short Horizontal
Net Width
U
Net Width
U
Net Width
U
Net
U
Net
U
Net
U
Net
U
Deduct
Deduct
Deduct
Width
Width
Width
Width
in
in
in
Deduct
Deduct
Deduct
Deduct
in
in
in
in
T1
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
195.00-180.00
T2
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
I80.00-160.00
T3
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
160.00-140.00
T4
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
140.00-120.00
W xTower
Job Existing 195-ft SST; Port St. Lucie, FL
Page5 of 17
Project
68412-0073
Date
15:21:5511/09/12
Paul JFord and Company
250 E. Broad Street Suite1500
Columbus, OH43215
Client
Designed by
Phone: 614.221.6679
FA614.448.4105
FOreslte Group
Charles Weir
Tower
Elevation
ft
Leg
Diagonal
Top Girt
Bottom Girt
Mid Girt
Long Horizontal
Short Horizontal
Net Width
U
Net Width
U
Net Width
U
Net
U
Net
U
Net
U
Net
U
Deduct
Deduct
Deduct
Width
Width
Width
Width
in
in
in
Deduct
Deduct
Deduct
Deduct
in
in
in
in
TS
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
120.00-100.00
T6
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
100.00-80.00
T7 80.00-60.00
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T8 60.0040.00
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T9 40.00-20.00
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
T10 20.00-0.00
0.000
1
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
0.000
0.75
Tower Section Geometry (cont'd)
Tower
Elevation
ft
Leg
Connection
Type
Leg
Bolt Size
No.
Diagonal
Top Girt
Bottom Girt
Mid Girt
Long Horizontal
Short Horizontal
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Size No.
Bolt Sire No.
Bolt Size
No.
in
in
in
in
in
in
in
T1
Flange
0.750
4
0.625
0
0.625
0
0.625
0
0.625
0
0.625
0
0.625
0
195.00-180.00
A325X
A325X
A325N
A325N
A325N
A325N
A325N
T2
Flange
0.750
4
0.750
1
0.750
1
0.625
0
0.625
0
0.625'
0
0.750
0
180.00-160.00
A325X
A325X
A325X
A325N
A325N
A325N
A325N
T3
Flange
1.000
4
0.750
1
0.625
0
0.625
0
0.625
0
0.625
0
0.750
0
160.00-140.00
A325X
A325X
A325N
A325N
A325N
A325N
A325N
T4
Flange
1.000
6
0.750
1
0.625
0
0.625
0
0.625
0
0.625
0
0.750
0
140.00-120.00
A325X
A325X
A325N
A325N
A325N
A325N
A325N
T5
Flange
1.250
6
1.000
1
0.625
0
0.625
0
0.625
0
0.625
0
0.750
1
120.00-100.00
A325X
A325X
A325N
A325N
A325N
A325N
A325X
T6
Flange
1.250
6
1.000
1
0.625
0
0.625
0
0.625
0
0.625
0
0.750
1
100.00-80.00
A325X
A325X
A325N
A325N
A325N
A325N
A325X
T7 80.00-60.00
Flange
L250
6
1.000
1
-0.625
0
0.625
0
0.625
0
0.625
0
0.750
1
A325X
A325X
A325N
A325N
A325N
A325N
A325X
T8 60.0040.00
Flange
1.500
6
1.000
1
0.625
0
0.625
0
0.625
0
0.625
0
0.750
1
A325X
A325X
A325N
A325N
A325N
A325N
A325X
T9 40.00-20.00
Flange
1.500
6
1.000
1
0.625
0
0.625
0
0.625
0
0.625
0
0.750
1
A325X
A325X
A325N
A325N
A325N
A325N
A325X
T10 20.00-0.00
Flange
1.750
6
1.000
1
0.625
0
0.625
0
0.625
0
0.625
0
0.750
1
A354-BC
A325X
A325N
A325N
A325N
A325N
A325X
Feed Line/Linear Appurtenances -'Entered As Round Or Flat
Description
Face
Allow
Component
Placement
Total
Number
Clear
Width or Perimeter
Weight
or
Shield
Type
Number
Per Row
Spacing
Diameter
Leg
ft
in
in in
p!f
LDF7-50A (1 5/8"
C
No
Ar (CaAa)
183.00 - 0.00
12
6
0.520
1.980
0.92
feam)
0.500
1.5" flat Cable Ladder
A
No
Af (CaAa)
195.00 - 0.00
2
2
18.000
1.500
1.80
Rail
1.500
1.5" flat Cable Ladder
B
No
Af (CaAa)
195.00 - 0.00
2
2
18.000
1.500
1.80
Rail
1.500
1.5' flat Cable Ladder
C
No
Af (CaAa)
195.00-0.00
2
2
18.000
1.500
1.80
Rail
1.500
WxTower
Job
Existing 195-ft SST; Port St. Lucie, FL
Page
6 of 17
Project
68412-0073
Date
15:21:5511109/12
Paul JFord and Company
250E.BroadStreet Suitel500
Columbus, OH43215
Client
Designed. by
Phone: 614.221.6679
FAX.- 614.448.4105
Foresite Group
Charles Weir
Feed Line/Linear Appurtenances Section Areas
Tower Tower Face AR AF CAAA CgAq Weight
Section Elevation In Face Out Face
B
0.000
0.000
7.500
0.000
54
C
0.000
0.000
14.628
0.000
87
T2
180.00-160.00
A
0.000
0.000
10.000
0.000
72
B
0.000
0.000
10.000
0.000
72
C
0.000
0.000
57.520
0.000
293
T3
160.00-140.00
A
0.000
0.000
10.000
0.000
72
B
0.000
0.000
10.000
0.000
72
C
0.000
0.000
57.520
0.000
293
T4
140.00-120.00
A
0.000
0.000
10.000
0.000
72
B
0.000
0.000
10.000
0.000
72
C
0.000
0.000
57.520
0.000
293
T5
120.00-100.00
A
0.000
0.000
10.000
0.000
72
B
0.000
0.000
10.000
0.000
72
C
0.000
0.000
57.520
0.000
293
T6
100.00-80.00
A
0.000
0.000
10.000
0.000
72
B
0.000
0.000
10.000
0.000
72
C
0.000
0.000
57.520
0.000
293
T7
80.00-60.00
A
0.000
0.000
10.000
0.000
72
B
0.000
0.000
10.060
0.000
72
C
0.000
0.000
57.520
0.000
293
T8
60.0040.00
A
0.000
0.000
10.000
0.000
72
B
0.000
0.000
10.000
0.000
72
-
C
0.000
0.000
57.520
0.000
293
T9
40.00-20.00
A
0.000
0.000
10.000
0.000
72
B
0.000
0.000
10.000
0.000
72
C
0.000
0.000
57.520
0.000
293
T10
20.00-0.00
A
0.000
0.000
10.000
0.000
72
B
0.000
0.000
10.000
0.000
72
C
0.000
0.000
57.520
0.000
293
Feed Line Center of Pressure
Section
Elevation
CPx
CPz
CPx
CPz
Ice
Ice
ft
in
in
in
in
TI
195.00-180.00
0.000
0.584
0.000
0.584
T2
180.00-160.00
0.000
1.956
0.000
1.956
T3
160.00-140.00
0.000
2.505
0.000
2.505
T4
140.00-120.00
0.000
3.019
0.000
3.019
T5
120.00-100.00
0.000
3.378
0.000
3.378
T6
100.00-80.00
0.000
3.809
0.000
3.809
T7
80.00-60.00
0.000
3.989
0.000
3.989
T8
60.0040.00
0.000
4.357
0.000
4.357
T9
40.00-20.00
0.000
4.595
0.000
4.595
T10
20.00-0.00
0.000
4.556"
0.000
4.556
NxTower
Job
Existing 195-ft SST; Port St. Lucie, FL
Page
7 of 17
Project
68412-0073
Date
15:21:5511/09/12
Paul J Ford and Company
250E.BroadSireet Suite1500
Columbus, OH43215
Client
Designed by
Phone: 614.221.6679
FAX: 614.448.4105
Foresite Group
Charles Weir
Discrete Tower Loads
Description
Face
Offset
Offsets:
Azimuth
Placement
CAAA
Cyln
Weight
or
Type
Hors
Adjustment
Front
Side
Leg
Lateral
Pert
ft
jl
fF
f?
1b
ft
ft
(2) BSA-185090/12-2 w/
A
From Leg
4.00
0.000
183.00
No Ice
3.64
3.61
34
Mount Pipe
0
0
X7-665-4 w/ Mount Pipe
A
From Leg
4.00
0.000
183.00
No Ice
8.99
7.00
56
0
0
(2) BSA-185090/12-2 w/
B
From Leg
4.00
0.000
183.00
No Ice
3.64
3.61
34
Mount Pipe
0
0
X7-665A w/ Mount Pipe
B
From Leg
4.00
0.000
183.00
No Ice
8.99
7.00
56
0
0
(2) BSA-185090/12-2 w/
C
From Leg
4.00
0.000
183.00
No Ice
3.64
3.61
34
Mount Pipe
0
0
X7-6654 w/ Mount Pipe
C
From Leg
4.00
0.000
183.00
No Ice
8.99
7.00
56
0
0
Sector Frame (3)
C
None
0.000
183.00
No Ice
19.73
19.73
825
Load Combinations
Comb. Description
2
1.2 Dead+1.6 Wind 0 deg - No Ice
3
0.9 Dead+1.6 Wind 0 deg -No Ice
4
1.2 Dead+1.6 Wind 30 deg - No Ice
5
0.9 Dead+1.6 Wind 30 deg -No Ice
6
1.2 Dead+1.6 Wind 60 deg - No Ice
7
0.9 Dead+1.6 Wind 60 deg -No Ice
8
1.2 Dead+1.6 Wind 90 deg - No Ice
9
0.9 Dead+1.6 Wind 90 deg - No Ice
10
1.2 Dead+1.6 Wind 120 deg - No Ice
11
0.9 Dead+1.6 Wind 120 deg - No Ice
12
1.2 Dead+1.6 Wind 150 deg -No Ice
13
0.9 Dead+1.6 Wind 150 deg -No Ice
14
1.2 Dead+1.6 Wind 180 deg -No Ice
15
0.9 Dead+1.6 Wind 180 deg - No Ice
16
1.2 Dead+1.6 Wind 210 deg - No Ice
17
0.9 Dead+1.6 Wind 210 deg - No Ice
18
1.2 Dead+1.6 Wind 240 deg - No Ice
19
0.9 Dead+1.6 Wind 240 deg - No Ice
20
1.2 Dead+1.6 Wind 270 deg - No Ice
21
0.9 Dead+1.6 Wind 270 deg - No Ice
22
1.2 Dead+1.6 Wind 300 deg -No Ice
23
0.9 Dead+1.6 Wind 300 deg -No Ice
24
1.2 Dead+1.6 Wind 330 deg -No Ice
25
0.9 Dead+1.6 Wind 330 deg - No Ice
26
Dead+Wind 0 deg - Service
27
Dead+Wind 30 deg - Service
28
Dead+Wind 60 deg -Service
WxTower
Job Existing 195-ft SST; Port St. Lucie, FL
Pa g e8 of 17
Project
68412-0073
Date
15:21:5511109/12
Paul J Ford and Company
250B.BroadStreet Suitel500
Columbus, OH43215
Client
Designed by
Phone: 614.221.6679
FAX. 614.448.4105
Foresite Group
Charles Weir
Comb. Description
29 .
Dead+Wind 90 deg - Service
30
Dead+Wind 120 deg -Service
31
Dead+Wind 150 deg -Service
32
Dead+Wind 180 deg - Service
33
Dead+Wind 210 deg - Service
34
Dead+Wind 240 deg - Service
35
Dead+Wind 270 deg- Service
36
Dead+Wind 300 deg -Service
37
Dead+Wind 330 dee - Service
Maximum Reactions
Location
Condition
Gov.
Vertical
Horizontal, X
Horizontal, Z
Load
lb
A
1b
Comb.
Leg C
Max. Vert
18
334712
34095
-19239
Max. H,
18
334712
34095
-19239
Max. H,
7
-276566
-28839
16259
Min. Vert
7
-276566
-28839
16259
Min. H.
7
-276566
-28839
16259
Min. H,
18
334712
34095
-19239
Leg
Max. Vert
10
334712
-34095
-19239
Max. H,
23
-276566
28839
16259
Max. H.
23
-276566
28839
16259
Min. Vert
23
-276566
28839
16259
Min. H.
10
334712
-34095
-19239
Min. H,
10
334712
-34095
-19239
Leg
Max. Vert
2
333967
0
39135
Max. H,
19
-145103
4593
-17911
Max. H.
2
333967
0
39135
Min. Vert
15
-277124
0
-33114
Min. H,
11
-145103
4593
-17911
Min. H.
15
-277124
0
-33114
- Tower Mast ReactionSummary '.
Load
Vertical
Shear,
Shear,
Overturning
Overturning
Torque
Combination
Moment, M.
Moment, M,
lb
lb
lb
Jbjt
lb-/t
lb-/1
Dead Only
44856
0
0
7871
0
0
1.2 Dead+1.6
Wind 0 deg - No
53828
0
-65323
-6021067
1
0
Ice
0.9 Dead+1.6
Wind 0 deg - No
40372
0
-65324
-6020654
1
0
Ice
1.2 Dead+1.6
Wind 30 deg - No
53828
28323
49057
4558612
-2637383
7936
Ice
0.9 Dead+1.6
Wind 30 deg - No
40371
28323
49057
4558863
-2636158
7944
Ice
1.2 Dead+1.6
Wind 60 deg -No
53828
50837
-29351
-2756415
-4790681
12896
Ice
0.9 Dead+1.6
Wind 60 deg -No
40371
50838
-29351
-2757499
-4788455
12889
Ice
1.2 Dead+1.6
Wind 90 deg - No
53828
56646
-1
9495
-5274751
14412
Ice
0.9 Dead+1.6
Wind 90 deg - No
40371
56646
0
7120
-5272319
14397
Ice
1.2 Dead+1.6
Wind 120 deg-
53828
56571
32661
3024746
-5222583
14720
PaTQWGT
Job Existing 195-ft SST; Port St. Lucie, FL
Page 9 of 17
Paul JFord and Company
250 E. Broad Street Suite 1500
Project
68412-0073
Date
15:21:55 11/09/12
Columbus, OH43215
Phone: 614.221.6679
FAX 614.448.4105
Client
Foresite Group
Designed by
Charles Weir
Load Vertical Shear, Shear, Overturning Overturning Torque
Combination Moment, M. Moment, M
No Ice
0.9 Dead+1.6 Wind 120 deg -
40371
56572
32661
3020974
-5220180
14700
No Ice
1.2 Dead+1.6 Wind 150 deg -
53828
28323
49057
4577539
-2637378
7936
No Ice
0.9 Dead+1.6 Wind 150 deg -
40371
28323
49057
4573048
-2636156
7937
No Ice
1.2 Dead+1.6 Wind 180 deg -
53828
0
58702
5541251
-1
0
No Ice
0.9 Dead+1.6 Wind 180 deg -
40371
0
58702
5536312
-1
0
No Ice
1.2 Dead+1.6 Wind 210 deg-
53828
-28323
49057
4577539
2637377
-7936
No Ice
0.9 Dead+1.6 Wind 210 deg -
40371
-28323
49057
4573048
2636155
-7937
No Ice
1.2 Dead+1.6 Wind 240 deg -
53828
-56571
32661
3024748
5222582
-14720
No Ice
0.9 Dead+1.6 Wind 240 deg -
40371
-56572
32661
3020976
5220179
-14700
No Ice
1.2 Dead+1.6 Wind 270 deg -
53828
-56646
-1
9497
5274751
-14412
No lce
0.9 Dead+1.6 Wind 270 deg -
40371
-56646
0
7121
5272319
-14397
No Ice
1.2 Dead+1.6 Wind 300 deg-
53828
-50837
-29351
-2756414
4790682
-12896
No Ice
0.9 Dead+1.6 Wind 300 deg -
40371
-50838
-29351
-2757498
4788456
-12889
No Ice
1.2 Dead+1.6 Wind 330 deg -
53828
-28323
-49057
-4558611
2637384
-7936
No Ice
0.9 Dead+1.6 Wind 330 deg -
40371
-28323
-49057
-4558863
2636159
-7944
No Ice
Dead+Wind 0deg -Service
44856
0
-10039
-918558
0
0
Dead+Wind 30 deg- Service
44856
4353
-7539
-693990
-405161
1220
Dead+Wind 60 deg- Service
44856
7813
-4511
-417029
-735974
1981
Dead+Wind 90 deg - Service
44856
8705
0
7894
-8I0334
2215
Dead+Wind 120 deg - Service
44856
8694
5019
471106
-802320
2262
Dead+Wind 150 deg -Service
44856
4353
7539
709649
-405173
1219
Dead+Wind 180 deg -Service
44856
0
9021
857711
0
0
Dead+Wind 210 deg -Service
44856
-4353
7539
709649
405173
-1219
Dead+Wind 240 deg - Service
44856
-8694
5019
471106
802320
-2262
Dead+Wind 270 deg -Service
44856
-8705
0
7894
810334
-2215
Dead+Wind 300 deg -Service
44856
-7813
-4511
417029
735974
-1981
Dead+Wind 330 deg -Service
44856
4353
-7539
-693890
405161
-1220
Solution SummarV
Sum oJAppliedForces
Sum ojReactions
Load
PX
PY
PZ
PX
PY
PZ
%Error
Comb.
lb
lb
lb
lb
15
lb
I
0
44856
0
0
44856
0
0.000%
2
0
-53828
-65324
0
53828
65323
0.001%
3
0
40371
-65324
0
40372
65324
0.002%
4
28323
-53828
49058
-28323
53828
49057
0.001%
5
28323
40371
49058
-28323
40371
49057
0.001%
6
50839
-53828
-29352
-50837
53828
29351
0.002%
7
50839
40371
-29352
-50838
40371
29351
0.001%
8
56647
-53828
0
-56646
53828
1
0.002%
9
56647
40371
0
-56646
40371
0
0.001%
10
56572
-53828
32662
-56571
53828
-32661
0.001%
MxTOwer
Job
Existing 195-ft SST; Port St. Lucie, FL
Page
10 of 17
Project
68412-0073
Date
15:21:5511/09/12
Paul J Ford and Company
250 E. Broad Street Suite1500
Columbus, OH43215
Phone: 614.221.6679
FAX..- 614.448.4105
Client
Foresite Group
Designed by
Charles Weir
Sum of Applied Forces
Sum of Reactions
Load
PX
PY
PZ
PX
PY
PZ
%Error
Comb.
lb
lb
lb
lb
lb
lb
11
56572
40371
32662
-56572
40371
-32661
0.002%
12
28323
-53828
49058
-28323
53828
49057
0.001%
13
28323
40371
49058
-28323
40371
49057
0.001%
14
0
-53828
58703
0
53828
-58702
0.002%
15
0
40371
58703
0
40371
-58702
0.001%
16
-28323
-53828
49058
28323
53828
-49057
0.001%
17
-28323
-40371
49058
28323
40371
-49057
0.001%
18
-56572
-53828
32662
56571
53828
-32661
0.001%
19
-56572
-40371
32662
56572
40371
-32661
0.002%
20
-56647
-53828
0
56646
53828
1
0.002%
21
-56647
-40371
0
56646
40371
0
0.001%
22
-50839
-53828
-29352
50837
53828
29351
0.002%
23
-50839
40371
-29352
50838
40371
29351
0.001%
24
-28323
-53828
-49058
28323
53828
49057
0.001%
25
-28323
-40371
-49058
28323
40371
49057
0.001%
26
0
-44856
-10039
0
44856
10039
0.000%
27
4353
-44856
-7539
-4353
44856
7539
0.000%
28
7813
44856
-4511
-7813
44856
4511
0.000%
29
8705
-44856
0
-8705
44856
0
0.000%
30
8694
-44856
5019
-8694
'44856
-5019
0.000%
31
4353
-44856
7539
-4353
44856
-7539
0.000%
32
0
-44856
9021
0
44856
-9021
0.000%
33
-4353
-44856
7539
4353
44856
-7539
0.000%
34
-8694
-44856
5019
8694
44856
-5019
0.000%
35
-8705
-44856
0
8705
44856
0
0.000%
36
-7813
-44856
-4511
7813
44856
4511
0.000%
37
-4353
-44856
-7539
4353
44856
7539
0.000%
Non -Linear Convergence Results,
Load
cbination
Converged?
Number
of Cycles
Displacement
Tolerance
Force
Tolerance
1
Yes
6
0.00000001
0.00000001
2
Yes
8
0.00000001
0.00010337
3
Yes
8
0.00000001
0.00007564
4
Yes
8
0.00000001
0.00011132
5
Yes
8
0.00000001
0.00008351
6
Yes
8
0.00000001
0.00011813
7
Yes
8
0.00000001
0.00009016
8
Yes
8
0.00000001
0.00011130
9
Yes
8
0.00000001
0.00008348
10
Yes
8
0.00000001
0.00010340
11
Yes
8
0.00000001
0.00007567
12
Yes
8
0.00000001
0.00011134
13
Yes
8
0.00000001
0.00008352
14
Yes
8
0.00000001
0.00011812
15
Yes
8
0.00000001
0.00009015
16
Yes
8
0.00000001
0.00011133
17
Yes
8
0.00000001
0.00008351
18
Yes
8
0.00000001
0.00010340
19
Yes
8
0.00000001
0.00007567
20
Yes
8
0.00000001
0.00011131
21
Yes
8
0.00000001
0.00008349
22
Yes
8
0.00000001
0.00011813
23
Yes
8
0.00000001
0.00009016
24
Yes
8
0.00000001
0.00011131
25
Yes
8
0.00000001
0.00008350
26
Yes
8
0.00000001
0.00008485
27
Yes
8
0.00000001
0.00008476
tnx'l v-wer
Job
Existing 195-ft SST; Port St. Lucie, FL
Page
11 of 17
Project
68412-0073
Date
15:21:5511/09/12
Paul J Ford and Company
250E.BroadStreet Suife1500
Columbus, OH43215
Client
Designed by
Phone: 614.221.6679
FAX• 614.448.4105
Foresite Group
Charles Weir
28
Yes
8
0.00OOD001
0.00008673
29
Yes
8
0.00000001
0.00008489
30
Yes
8
0.00000001
0.00008508
31
Yes
8
0.00000001
0.00008507
32
Yes
8
0.00000001
0.00008694
33
Yes
8
0.00000001
0.00008506
34
Yes
8
0.00000001
0.00008508
35
Yes
8
0.00000001
0.00008489
36
Yes
8
0.00000001
0.00008673
37
Yes
8
0.00000001
0.00008475
Maximum Tower Deflections -Service Wind
Section
No.
Elevation
A
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
Twist
°
Tl
195 - 180
1.78
30
0.082
0.006
T2
180 - 160
1.52
30
0.080
0.005
T3
160 - 140
1.19
30
0.070
0.004
T4
140 -120
0.91
30
0.060
0.003
T5
120 - 100
0.67
30
0.049
0.003
T6
100- 80
0.47
30
0.040
0.002
T7
80-60
0.31
30
0.031
0.002
T8
60 - 40
0.18
30
0.023
0.001
T9
40 - 20
0.09
30
0.015
0.001
T10
20 - 0
0.03
30
0.007
0.000
Critical Deflections and Radius of Curvature.' Service Wind
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in ft
183.00 (2)BSA-185090/12-2w/Mount 30 1.57 0.081 0.005 312191
Pipe
Maximum Tower Deflections - Design Wind
Section
Elevation
Harz.
Gov.
Tilt
Twist
No.
Deflection
Load
ft
in
Comb.
°
TI
195 - 180
11.54
10
0.532
0.033
T2
180 - 160
9.86
10
0.520
0.031
T3
160 - 140
7.75
10
0.454
0.028
T4
140. 120
5.90
10
0.390
0.023
TS
120 - 100
4.33
10
0.320
0.018
T6
100 - 80
3.05
10
0.259
0.014
T7
80 - 60
2.01
10
0.201
0.011
T8
60 -40
1.18
10
0.151
0.007
T9
40 - 20
0.58
10
0.098
0.005
TI O
20 - 0
0.19
10
0.047
0.002
OIXI wer
Job
Existing 195-ft SST; Port St. Lucie, FL
Page
12 of 17
Pau/ J Ford and Company
250 E. Broad Street Suite 1500
Project
68412-0073
Date
15:21:55 11/09/12
Columbus, OH43215
Phone: 614.221.6679
FAX..- 614.448.4105
Client
Foresite Group
Designed by
Charles Weir
Critical Deflections and Radius of Curvature - Design Wind
Elevation
f!
Appurtenance
Gov. Deflection Tilt
Load
Comb. in '
Twist Radius of
Curvature
ft
183.00
(2) BSA-185090/12-2 w/Mount
Pipe
10 10.19 0.525
0.032 49034
Bolt Design Data
Section
No.
Elevation Component Bolt
Type Grade
ft
Bolt Size Number Maximum Allowable
Of Loadper Load
in Bolts Bolt lb
Ratio Allowable Criteria
Load Ratio
Alowable
Tl
195
Leg
A325X
0.750
4
1060
29821
0.036
✓
1
Bolt Tension
12
180
Leg
A325X
0.750
4
7512
29821
0252
1
Bolt Tension
Diagonal
A325X
0.750
1
2984
8972
'10'
1
Member Block
0.333
Y
Shear
Top Girt
A325X
0.750
1
1557
8972
J
1
Member Block
0.174
Y
Shear
T3
160
Leg
A325X
1.000
4
14352
53014
1
Bolt Tension
0271
Diagonal
A325X
0.750
1
3677
8972
0.410
1
Member Block
Shear
T4
140
Leg
A325X
1.000
6
14264
53014
1
Bolt Tension
0.269
Diagonal
A325X
0.750
1
4543
11963
V'r
1
Member Block
0.380
Shear
T5
120
Leg
A325X
1.250
6
18432
82835
1
Bolt Tension
0223
Diagonal
A325X
1.000
1
6666
16270
0410
��
Y
1
Member Block
Shear
Secondary
A325X
0.750
1
2358
8972
1
Member Block
Horizontal
0263
.
Shear
T6
100
Leg
A325X
1.250
6
23447
82835
1
Bolt Tension
0283
i°f°
Diagonal
A325X
1.000
1
7654
16270
1
Member Block
OA70
:'
Shear
Secondary
A325X
0.750
1
2888
8972
1
Member Block
Horizontal
0322
Shear
T7
80
Leg
A325X
1.250
6
28613
82835
�!
1
Bolt Tension
0.345
Y�
Diagonal
A325X
1.000
1
8823
16270
0542
Y
1
Member Block
Shear
Secondary
A325X
0.750
1
3472
12615
1
Member Bearing
Horizontal
'
0275
T8
60
Leg
A325X
1.500
6
33953
119282
1
Bolt Tension
02854.,r+y'
Diagonal
A325X
1.000
1
10023
20338
1
Member Block
0.493
Y'
Shear
Secondary
A325X
0.750
1
4166
12615
Y
1
Member Bearing
Horizontal
0.330
T9
40
Leg
A325X
1.500
6
39368
119282
0.330
' J
1',
1
Bolt Tension
Diagonal
A325X
1.000
1
11175
24406
I
Member Block
0458
'Y
Shear
Secondary
A325X
0.750
1
4886
12615
y+r
1
Member Bearing
Horizontal
0387
TIO
20
Leg
A354-BC
1.750
6
44809
169121
1
Bolt Tension
0.265
Diagonal
A325X
1.000
1
12317
21206
0.581
_�
V'
1
Member Bearing
Secondary
A325X
0.750
1
5624
12615
0.446
'
1
Member Bearing
Horizontal
MxTower
Job
Existing 195-ft SST; Port St. Lucie, FL
Page
13 of 17
Project
68412-0073
Date
15:21:5511/09/12
Paul JFord and Company
250E.BroadStmei Suite1S00
Columbus, OH 43215
Client
Designed by
Phone: 614.221.6679
FAX 614.448.4105
Foresite Group
Charles Weir
Section Elevation Component Bolt BOBSize Number Maximum Allowable Ratio Allowable Criteria
No. Type Grade Of Loadper Load Load Ratio
ft in Bolts Bolt lb Allowable
Compression Checks
Leg,Design Data (Compression)
Section Elevation
No.
ft
Size L L. Kl/r A P.
ft fi in' lb
QP"
lb
Ratio
P.
gyp"
Tl 195 - 180
1 VT'solid 15.00 3.00 96.0 1.767 -5668
40536
0.140
K=1.00
V
T2
180 - 160
2 1/4" solid
20.03
5.01
106.8
3.976
-33245
77655
0.428
K=1.00
V
T3
160 - 140
3" solid
20.03
5.01
80.1
7.069
-63860
198902
0.321 t
K=1.00
v
T4
140 - 120
3 1/4" solid
20.03
5.01
74.0
8.296
-96295
250223
0.385 1
K=1.00
f/
T5
120 - 100
3 3/4" solid
20.03
5.25
67.2
11.045
-125990
357389
0.353
K=1.00
v
T6
100 - 80
4" solid
20.03
5.21
62.5
12.566
-162048
424978
0.381 t
K=1.00
`/
T7
80 - 60
4 12" solid
20.03
5.18
55.3
15.904
-200199
572460
0.350 t
K=1.00
I/
T8
60-40
412"solid
20.03
5.16
55.0
15.904
-240228
573492
0.419'
K=1.00
v
T9
40-20
43/4"solid
20.03
5.14
52.0
17.721
-281755
654481
0.431
K=1.00
S/
T10
20 - 0
5" solid
20.03
5.13
49.3
19.635
-324300
739966
0.438 t
K=1.00
v
' P " / �P" controls
Diagonal Design Data (Compression)
Section Elevation
Size L L" KI1r A P.
¢P"
Ratio
No.
P"
ft
ft ft in' !b
lb
gyp"
Tl 195. 1Rn
11/4"snlid 5.00 4.84 130.2 1.227 -4180
16354
0.256�
T2
180-160
L2.5 x25 x 3/16
T3
160-140
L2.5 x25 x 3/16
T4
140-120
L2.5 x25x 1/4
T5
120-100
L3.5 x3.5x 1/4
T6
100-80
L3.5 x3.5 x 1/4
T7
80-60
L4x4x 1/4
. K=0.70
v
7.62
3.72
97.6
0.902
-3007
17704
0.170
K=1.08
y/
9.22
4.48
111.4
0.902
-3746
15207
0.246 t
K=1.03
v
10.96
5.33
130.3
1.190
4571
15770
0.290 t
K=1.00
3/
15.24
7.75
133.9
1.690
-7035
21285
0.331 t
K=1.00
v
16.80
8.51
147.1
1.690
-8121
17653
0.460 t
K=1.00
3/
18.45
9.30
140.4
1.940
-9367
22248
0.421 t
K=1.00
v
MxTower
Job
Page
Existing 195-ft SST; Port St. Lucie, FL
14 of 17
Paul J Ford and Company
Project
Date
250E.BroadStreet Suite1500
68412-0073
15:21:5511109/12
Cohonhtts, OH43215
Client
Designed by
Phone: 614.221.6679
Foresite Group
Charles Weir
FAX 614.448.4105
Section
Elevation
Size
L
L„
KUr
A
P.
Qp"
Ratio
No.
P.
ft
f7
ft
in2
lb -
lb
�P"
T8
60 - 40
L 4 x 4 x 5/16
20.16
10.15
154.0
2.400
-10608
22863
0.464
K=1.00
V
T9
40 - 20
L 4 x 4 x 3t8
21.92
11.02
167.8
2.860
-11851
22955
0.516'
K=1.00
V
T10
20 - 0
L 5 x 5 x 5116
23.71
11.90
143.7
3.030
-13224
33151
0.399'
K=1.00
1/
P. / AP controls
ntal Desian Data
Section Elevation
Size L
L„
KI1r A
P"
Ratio
No.
P
ft
ft
ft
in2
lb
lb
gyp"
Tl 195 -180
1" solid 4.00
3.89
1302 0.785
-1478
16467
0.141
K=0.70
V
P" / $P" controls
Secondary Horizontal Desian Data (Compression) I
Section
Elevation
Size
L
L.
KUr
A
P.
�P.
Ratio
No.
P"
ft
ft
ft
-
in2
lb
I¢ .
�P
T5
120 - 100
L 2.5 x 25 x 3/16
11.48
11.17
135.3
0.902
-2358
11124
0.212'
K=0.50
`/
T6
100 - 80
L 2.5 x 25 x 3/16
13.48
13.15
159A
0.902
-2888
8023
-0.360'
K=0.50
V/
T7
80 - 60
L 3 x 3 x 1/4
15.48
15.11
153.1
1.440
-3472
13873
0.250'
K=0.50
V
T8
60 - 40
L 3 x 3 x 1/4
17.49
17.11
173.4
1.440
-4166
10817
0.385 '
K-0.50
V
T9
40 - 20
L 3.5 x 3.5 x 1/4
19.49
19.09
165.1
1.690
4886
14014
0.349'
K=0.50
V
T10
20 - 0
L 3.5 x 3.5 x 1/4
21.49
21.07
182.2
1.690
-5624
11504
0.489'
K=0.50
V
P. / 6P" controls
Top. Girt Desian Data (Compression) I
Section
Elevation
Size
L
L"
KUr
A
P.
�P"
Ratio
No.
P"
ft
ft
ft
in2
/b
lb
6P"
Tl
195 - 180
1"solid
4.00
3.88
130.2
0.785
-70
10467
0.007
K=0.70
V
T2
180 - 160
L 2.5 x 2.5 x 3/16
4.00
3.60
103.7
0.902
-1599
16594
0.096'
K=1.19
V
P„ /OP. controls
ftiffower
Job Existing 195-ft SST; Port St. Lucie, FL
Page
15 of 17
Project
68412-0073
Date
16:21:5511/09/12
Paul J Ford and Company
250E.BroadStreet Suite 1500
Columbus, OH43215
Phone: 614.221.6679
FAY.-614.448.4105
Client
Foresite Group
Designed by
Charles Weir
Tension Checks
Leg Design Data (Tension)
Section
Elevation
Sim
L L. KI/r A
P.
OP„
Ratio
No.
P.
ft
ft ft in'
/b
lb
gyp"
Tl
195 - 180
1 12" solid
15.00 3.00 96.0 1.767
4240
79522
0%5-;
T2
180-160
21/4"solid
20.03 5.01 106.8 3.976
30049
178924
0.168'
T3
160 - 140
3" solid
20.03 5.01 80.1 7.069
57408
318086
0.180'
T4
140 - 120
3 1/4" solid
20.03 5.01 74.0 8.296
85583
373310
0.229'
TS
120 -100
3 3/4" solid
20.03 5.25 67.2 I1.045
110775
497010
0.273 '
T6
100 - 80
4" solid
20.03 521 62.5 12.566
140900
565487
0.249'
T7
80-60
412"solid
20.03 5.18 55.3 15.904
171982
715694
0.240'
T8
60-40
412"solid
20.03 5.16 55.0 15.904
204033
715694
0.285'
T9
40-20
43/4"solid
20.03 5.14 52.0 17.721
236573
797425
0.J2997'
Y
T10
20-0
5" solid
20.03 5.13 49.3 19.635
269260
883573
0.305'
' P, / lP" controls
Diagonal Design Data (Tension)
Section Elevation Sire L L„ KI1r A P. QP" Ratio
No. P.
jt jt ft in lb lb 6p"
12
180 - 160
L 2.5 x 2.5 x 3/16
7.62
3.72
59.4
0.553
2984
24075
0.124 '
T3
160 - 140
L 2.5 x 2.5 x 3/16
9.22
4A8
71.1
0.553
3677
24075
0.153 '
T4
140 - 120
L 2.5 x 2.5 x 1/4
10.96
5.33
85.3
0.728
4543
31687
0.143 '
T5
120 - 100
L 3.5 x 3.5 x 1/4
15.24
7.75
85.3
1.057
6666
45961
0.145 '
T6
100 - 80
L 3.5 x 3.5 x 1/4
16.80
8.51
93.6
1.057
7654
45961
0.167'
V
T7
80 - 60
L 4 x 4 x 1/4
18.45
9.30
89.3
1.244
8823
54117
0.163
T8
60 - 40
L 4 x 4 x 5116
20.16
10.15
98.2
1.536
10023
66830
0.150'
T9
40 - 20
L 4 x 4 x 3/8
21.92
11.02
107.5
1.829
11175
79544
0.J1440
Y
T10
20 - 0
L 5 x 5 x 5116
23.71
11.90
91.0
2.009
12317
87384
0.141 '
++ f
MxToweY
Job
Page
Existing 195-ft SST; Port St. Lucie, FL
16 of 17
Paul J Ford and Company
Project
Date
250 E. Broad Street Suite 1500
68412-0073
15:21:55 11/09/12
Columbus, OH43215
Client
Designed by
Phone: 614.221.6679
Foresite Group
Charles Weir
X
FA614.448.4105
Section Elevation Size L L. KUr A P. rpP„ Ratio
No. P.
ft ft ft in2 lb !b bp"
P„ / OP" controls
Horizontal Design Data (Tension)
Section Elevation Size L L+ KUr A P. �P„ Ratio
No. P.
ft ft ft in2 lb lb gyp"
TI 195 - 180 I"solid 4.00 3.88 186.0 0.785 1483 35343 0.042
Secondary Horizontal Design Data (Tension)
Section
Elevation
Size
L
L.
KUr
A
P"
Ratio
No.
P.
ft
ft
ft
in2
lb
lb
gyp"
T5
120 -100
L 2.5 x 25 x 3/16
11.48
11.17
172.2
0.553
2358
24075
0.098
T6
100 - 80
L 2.5 x 25 x 3/16
13.48
13.15
202.8
0.553
2888
24075
0.120
T7
80 - 60
L 3 x 3 x 1/4
15.48
15.11
195.0
0.916
3472
39843
0.087 t
T8
60 - 40
L 3 x 3 x 1/4
17.49
17.11
220.8
0.916
4166
39843
0.105 t
T9
40 - 20
L 3.5 x 3.5 x 114
19.49
19.09
210.2
1.103
4886
48000
0.102 t
T10
20 - 0
L 3.5 x 3.5 x 1/4
21.49
21.07
232.0
1.103
5624
48000
0.-1117 t
Y
' P, / r P. controls
Top Girt Design Data
(Tension)
Section
Elevation
Size L L. KUr
A P.
¢P"
Ratio
No.
P.
ft
ft ft
in2 lb
16
gyp"
TI
195 -180
1"solid 4.00 3.88 186.0
0.785 70
35343
0.0•012
Y
T2
180 - 160
L 2.5 x 2.5 x 3/16 4.00 3.60 59.8
0.553 1557
24075
0.065
V
P. / 4P" controls
Section Capacitv.Table I
Section
Elevation
Component
Size
Critical
P
opelm
%
Pass
No.
ft
Type
Element
lb
lb
Capacity
Fail
TI
195 - 180
Leg
1 1/2" solid
2
-5668
40536
14.0
Pass
T2
180 - 160
Leg
2 1/4" solid
35
-33245
77655
42.8
Pass
T3
160 - 140
Leg
3" solid
65
-63860
198902
32.1
Pass
T4
140- 120
Leg
3 1/4" solid
92
-96295
250223
38.5
Pass
MxTower
Job
Existing 195-ft SST; Port St. Lucie, FL
Page
17 of 17
Paul JFord and Company
250EBroadStreet Suitel500
Project
68412-0073
Date
15:21:5511/09/12
Columbus, OH43215
Client
Designed by
Phone: 614.221.6679
FAX.- 614.448.4105
Foresite Group
Charles Weir
Section
Elevation
Component
Size
Critical
P
oP,n„
%
Pass
No.
.lt
Type
Element
lb
lb
Capacity
Fail
T5.
120 -100
Leg
3 3/4" solid
119
-125990
357389
35.3
Pass
T6
100-80
Leg
4" solid
140
-162048
424978
38.1
Pass
T7
80-60
Leg
412"solid
161
-200199
572460
35.0
Pass
T8
60 - 40
Leg
4 12" solid
182
-240228
573492
41.9
Pass
T9
40-20
Leg
43/4"solid
203
-281755
654481
43.1
Pass
T1O
20 - 0
Leg
5" solid
223
-324300
739966
43.8
Pass
TI
195 - 180
Diagonal
1 1/4" solid
7
-4180
16354
25.6
Pass
72
180 - 160
Diagonal
L 2.5 x 2.5 x 3/16
40
-3007
17704
17.0
Pass
T3
160 - 140
Diagonal
L 2.5 x 2.5 x 3/16
67
-3746
15207
24.6
Pass
T4
140 - 120
Diagonal
L 2.5 x 2.5 x 1/4
94
4571
15770
29.0
Pass
TS
120 - 100
Diagonal
L 3.5 x 3.5 x 1/4
121
-7035
21285
33.1
Pass
T6
100 - 80
Diagonal
L 3.5 x 3.5 x 1/4
142
-8121
17653
46.0
Pass
T7
80 - 60
Diagonal
L 4 x 4 x 1/4
163
-9367
22248
42.1
Pass
T8
60 - 40
Diagonal
L 4 x 4 x 5/16
194
-10608
22863
46.4
Pass
T9
40 - 20
Diagonal
L 4 x 4 x 3/8
205
41851
22955
51.6
Pass
T10
20 - 0
Diagonal
L 5 x 5 x 5116
226
-13224
33151
39.9
Pass
Tl
195 - 180
Horizontal
1" solid
10
-1478
10467
14.1
Pass
T5
120 - 100
Secondary Horizontal
L 2.5 x 2.5 x 3/16
127
-2358
11124
21.2
Pass
T6
100 - 80
Secondary Horizontal
L 2.5 x 2.5 x 3/16
148
-2888
8023
36.0
Pass
T7
80 - 60
Secondary Horizontal
L 3 x 3 x 114
169
-3472
13873
25.0
Pass
T8
60 - 40
Secondary Horizontal
L 3 x 3 x 1/4
190
4166
10817
38.5
Pass
T9
40 - 20
Secondary Horizontal
L 3.5 x 3.5 x 1/4
211
4886
14014
34.9
Pass
TIO
20 - 0
Secondary Horizontal
L 3.5 x 3.5 x 1/4
233
-5624
11504
48.9
Pass
Tl
195 -180
Top Girt
I" solid
4
-70
I0467
0.7
Pass
T2
180 -160
Top Girt
L 2.5 x 2.5 x 3/16
37
-1599
16594
9.6
Pass
Summary
Leg (T10)
43.8
Pass
Diagonal
51.6
Pass
(T9)
•
Horizontal
14.1
Pass
(Tl)
Secondary
48.9
Pass
Horizontal
(T10)
Top Girt
9.6
Pass
(T2)
Bolt Checks
58.1
Pass
RATING =
58.1
Pass
Program Version 6.03.0 - 12/72011 File:G:/rOWER/684 Foresite Group2012/68412-0073 S. Florida Recycles/68412.0073.eri