Loading...
HomeMy WebLinkAboutOco nner gen specsGENERAL' 16/20/22 kW INCLUDES: • True Power- Electrical Technology M Two Line LCD Multilingual Digital Evolution' Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 5 for Details. • Electronic Governor • Standard WI-Fi'" Remote Monitoring • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation ■ 5 Year Limited Warranty • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18" (457 mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. https:llassets.swri.org//i6ratyIDirectotyOfListedProducts/ Constructionlndustry/973_DoC_204_13204-01-01 _Rev9. pdf FEATURES�� GUARDIAN SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-1, G007037-1 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-1 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-1, G007038-1 (Aluminum - Bisque) - 20 kW 60 Hz Models GO07043-2, G007042-2 (Aluminum - Bisque) - 22 kW 60 Hz GENERAC �- `.s &S - /% CLISTED QV lFf u111111 ^b ■ Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible. Generac's G-Force engine This state-of-the-art power maximizing regulation system is standard on lineup offers added peace of mind and reliability for when you need it the most. The all Generac models. It provides optimized FAST RESPONSE to changing G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by extended run times in high temperatures and extreme operating conditions. electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. O TRUE POWER' ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer form produce less than 5%Total Harmonic Distortion for utility quality power. This allows network provides parts and service know-how for the entire unit, from the confident operation of sensitive electronic equipment and micro -chip based appliances, engine to the smallest electronic component. such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. O MOBILE LINK— REMOTE MONITORING: FREE with every Guardian Series Home standby generator. Allows you to monitor the status of your generator from anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current w GENERAC' aMs ' P R 0 M I S E operating status and maintenance alerts. Connect your account to your authorized service dealer for fast, friendly and proactive service. With Mobile Link, you are taken care of before the next power outage. GENERAC® 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life, • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. Displaced phase excitation Maximizes motor starting capability. Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution*" Controls ■ Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition, • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of five (5) seconds by a qualified dealer. ■ Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit-.. _ ..._ ........ .._...--- --- • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. 0 Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" (457 mm) away from a building, 16/20/22 kW ............ Installation System 0 1 ft (305 mm) flexible fuel line connector ■ Direct -to -dirt composite mounting pad r Integral sediment trap Remote Monitoring ■ Ability to view generator status ■ Ability to view generator Exercise/Run and Total Hours ■ Ability to view generator maintenance information s Monthly report with previous month's activity. i Ability to view generator battery information * Weather information GENERAC6 features and benefits Absorbs any generator vibration when connected to rigid pipe. Complex lattice design prevents settling or sinking of the generator system. Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. Monitor your generator via your smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind Review the generators complete protection profile for exercise hours and total hours Provides maintenance information for your specific model generator when scheduled maintenance is due Detailed monthly reports provide historical generator information Built in battery diagnostics displaying current state of the battery Provides detailed local ambient weather conditions for generator location 16/20/22 kW Generator GENERAC° specifications Model G0070354, G007036-1, 111007038-1, G007039-1 111007042-2, G007043-2 LRated Maximurh Continuous Power Capaciiy (LP) G0070374 (16 kW) 16r1100 Gllw (20 kW) AMC watts* (22 kW) 22 00011Gatfs* Rated Maximum Continuous Power Capacity (NG) 16,000 Watts' 18,060 Watts* 19,500 Watts' Rated Voltage 240 240 240 Rated Maximum Continuous Load Current - 240 Volts (LP/NG) 66.7 / 66.7 83.3 / 75.0 91.7 / 81.3 Total Harmantc Distort ion Less than A — — L_e_ss than A - - - Cass ihaA Main Line Circuit Breaker 70 Amp 90 Amp _n 100 Amp rph e - 1 I 1 Number of Rotor Pales 2 2 2 [,Rated AC Frequenc' 60 9i 60 Hz bOHz Power Factor 1 0 1.0 1.0 BatterAequirement (nnt lnciuded) ��j,,:....„. - - i2 Volts, $roue 26R 54_0 CCA Mlmmum or Group 3_6_A_GM 650 CCA M_rnimum Unit Weight (lb/kg) Dimensions (L x W x f —irVmm �"°" 409 / 18fi� 448 / 203 - t.. 466l211 48x75x29 J121$x638x732 Sound out ut In dB(Aat 23 ft 7 m with generator at normal load** p O ( ) goperating- al 67 67 _ 67 � — -T_ ,)sound output m dB;A) at 23 tt (7'm) with generator" in quiet Test low speed exercise mode'' � _ 55 55 57 _ Exercise duration _. 5 min 5 min 5 min Engine Type of Engine tNomber of Lylindeis Displacement rCyl(ndet Bock Valve Arrangement Plgnition 5ysfem Governor System Itompression Ratio Starter Oil Capacity including fitter Operating rpm Fuel Consumption Natural Gas 2 999 cc Overhead Valve Solid-shete w/ ]Magneto Electronic 9.5:1 12 VDC Approx 1.9`gt/i.9L_ 3,600 228 (6.46) 327 (9.26) It Liquid Propane fh1/hr (gaVhr) [Uhr] 1/2 Load 74 (2.03) [7.70] 87 (2.37) [8.991 92 (2.53)19.57] Full Load 107 (2.94) [11.11] 130 (3.56) [13.481 142 (3.90) [14.77] Note: Fuel pipe must be shed for full load. Required fuel ressure to generator fuel inlet at all load ranges - 3.5-7" water column (7-13 mm mercury) for natural gas,10-12" water column (19-22 mm mercury) for LP gas. For BTU content, multiply fts/hr x 2500 (LP)_ or ftl/hr x 1000 (NG). For Megajoule content, multiply rift x 93.15 (LP) or m3/hr x 37.26 LNG__ - Two -Line Plain Text Multilingual LCD Display {;Mode Btid6ns:Auto_ Manual ft3/hr (rri 1/2 Load Full Load 'Off Ready to Run/Maintenance Messages [Egir Run Hou—m jridicat'ion Programmable _stan delay between 2-1500 seconds Utility Voltage Loss/Return-to Utility Adjustable (Brownout Setting) Future Set Capable Exerciser/Exercise Set Error Warning Rtln/Alami/Malntenance Logs_ Engine Start Sequence Starter Lack -out Smart Battery Charger Charger Faull/Missinp AC W;& g Low Biery/Battery Problem Protection and Battery Condition Indication Automatic Voltage Regulation with Over and Under Voltage Protection Under-Frequency/Overload/Stepper Overcurrent Protection Safely Fused/Fuse Problem Protection Automatic Low Oil Pressure/High Oil Temperature Shutdown Overcrank/Overspeed (@ 72 Hi)/rpm Sense Loss Shutdown High Engine Temperature Shutdown ' Internal FaultMcorrect Wiring Protec_ti_on Common External Fault Capability Feld Upgradabte Firmware 995 cc Overhead Valve 5611d-state w/LBlagneto Electronic 9.5:1 12 VDC Approx 1.9 qt / 1.8 L 3,600 218 (6.17) 309 (8 75) GENERAC G-force 1000 Series 2 999 cc Muminurn w/Cast Iron Slewve Overhead Valve Solid-state w/Magneto Electronic 9.1 12 VDC Apj r 1.9 qt / 1.8 L �3,600 204 (5.78) 301 (8 52) Simple user interface for ease of operation. Automatic Start on Utility failure 7 day exerciser. Start with starter control, unit stays on. If utility fails, transfer to load takes place. Stops unit. Power is -reo-ved. Control and charger stilt opetate, Standard - - _ — Standard Standard (programmable by dealer only) From 140-171 V / 190-216 V Standard 56Nints Each Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). Starter cannot re-engage until 5 sec after engine has stopped. Standard Standard Standard Standard Standard Standard Standard Standard Standard standard Standard Standard "'Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available far this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). - Ma>amum kilovolt amps and current are subject to and limited by such factors as fuel Winegajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percentfor each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F) above 16 °C (60 `F . GENERACO 16/20/22 kw switch options Limited Circuits Switch Features Model 0007036-1 (16kW) ■ 16 space, 24 circuit, breakers not included. No. or Potes 2 ■ Electrically operated, mechanically -held contacts for fast, positive Current Rating (Amps) Voltage Rating (VAC) 100 120 / 240,16 connections 6 Rated for all classes of load,100% equipment rated, both inductive and Utility Voltage Monitor (Fixed)* -Pica-up 80% resistive. -Dropout 65% ■ 2-pole, 250 VAC contactors. Return to utility' approx 15 sec 30 millisecond transfer time. Exercises bi-weekly for 5 minutes* Standard Dual coil design. rut. Listed Standard ■ Rated for both copper and aluminum conductors. Total circuits Available 24 • Main contacts are silver plated or silver alloy to resist welding and sticking. rt�dem Breaker capantities 8 tandems ■ NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor Circuit Breaker Protected mounting flexibility. Available RMS Symmetrical Fault Current @ 250 Volts 10.000 ■ Multi listed for use with 1"standard, tandem, GFCI and AFCI breakers from *Function of Evolution Controller Siemens, Murray, Eaton and Square D for the most flexible and cost effective Exercise can be set to weekly or monthly install. Dimensions_ ...... w1 Height Width Depth Hi H2 W1 W2 in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 210-#14 Service Rated Smart Switch Features ■ Includes Digital Power Management Technology standard (DPM). Intelligently manages up to four air conditioner loads with no additional hardware. Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). # Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resis- tive. • 2-pole, 250 VAC contactors. # Service equipment rated, dual coil design. ■ Rated for both aluminum and copper conductors. * Main contacts are silver plated or silver alloy to resist welding and sticking. 6t NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions T200 Amps 120/240,19 Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 2.75 30.1 10.5 13.5 6.91 min 679.4 764.3 266.7 1 343.0 175.4 H2 H1 Model 0007037.1(16 kW)/0007039.1(20 kW)/ G007043.2 (22 kW) No. of Poles 2 Current Rating (Amps) 200 "Voltage Rating (4AC) 120/240,10 Utility Voltage Monitor (Fixed)* -Pick-up 80% -Dropout 65% Return is Utility* approx. 13_see Exercises bi-weekly for 5 minutes* Standard �UL Listed Standard Enclosure Type NEMAIUL 311 Circuit Breiker Protected 22,000 Lug Range 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly 16/20/22 W Model # Product I !G007005-0 Wi-Fi LP Fuel Level Monitor G005819-0 26R Wet Cell Battery i G007101-0 Battery Pad Warmer I_ G007102-0 f. Oil Warmer G007103-1 j Breather Warmer G005621-0 Auxiliary Transfer Switch Contact Kit G007027-0 - Bisque Fascia Base Wrap Kit (Standard on 22 kW) G005703-0 - Bisque i G006485-0 G006873-0 Paint Kit GENERAC available accessories Description The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon- itoring the LP tank's fuel level is an important step in making sure your generator is ready to run during ani unexpected powerfailure. Status alerts are available through a free application to notify when your LP tank' is in need of a refill. C Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). The pad warmerrests underthe battery. Recommended for use if the temperature regularly falls below 0 °F (-18 °C). (Not necessary for use with AGM -style batteries). Oil warmer slips directly over the oil fitter. Recommended for used the temperature regularly falls below 0 °F (-18 °C). The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch up a generator enclosure. Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its (50 Amps) power management capabilities. It provides additional power management flexibility not found in any other, power management system. dimensions & UPCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. (zs.s in] LEFT SIDE VIEW [48.5 ee FRONT VIEW Model UPC G007035-1 696471074161 G007036-1 696471074154 G007037-1 696471074178 G007038-1 696471074185 G007039-1 696471074192 G007042-2 696471074208 G007043-2 696471074215 GENE RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 10000000194-H (8/01/18)