Loading...
HomeMy WebLinkAboutREG SPECS - 7-20-20Bulletin LP-T R122H March 2010 Type R122H First -Stage Regulator Introduction The Type R122H is an Underwriters Laboratories listed regulator designed for Two -Stage LP -Gas systems. The unit is designed to reduce the tank pressure to an outlet pressure of 10 psig. The compact size makes it ideal for small domestic applications and underground tanks. The outlet pressure setting is nonadjustable and is factory set at a nominal 10 psig. Screened drip - lip vents are oriented over the outlet as standard. Features • 20 Year Recommended Replacement Life - The R122H is designed using rugged time proven design concepts and constructed of corrosion resistant materials. both intemally and externally. With proper installation and periodic inspection and maintenance the R122H regulator will meet a 20 Year Recommended Replacement Life. • Dual Gauge Taps - Built-in 116 inch NPT gauge taps orificed to a number 54 drill size on both the inlet and outlet side of the regulator allow for easy testing. • Durability - A fluorocarbon valve disc is utilized to improve lockup performance in systems with contaminated gas. • Improved Regulation - A large fabric -reinforced diaphragm and stabilizer clip deliver accurate and stable regulation. • Easy Installation - The units compact size and easily accessible inlet and outlet wrench Oats make installation easy even in the tightest installations. FISHER Figurer. Type R122H Forst -Stage Regulator Superior Overpressure Protection - The combination of a high capacity relief valve and large vent provide overpressure protection that exceeds UL standards When used in conjunrtion with a R622 or R652. the two -stage system will limit the downstream pressure from the second -stage to 2 psig even in a double failure situation. Corrosion -Resistant - Added corrosion resistance from an internal and external coating process for all castings prior to painting, stainless steel relief valve spring and retainer and a corrosion resistant relief valve seat. Positive Draining Spring Case - When installed properly with the spring case vent pointed down, the design allows moisture formed in the spring case to drain out limiting the problems with corrosion and freezing water in the spring case. °Y EMERSON. Process Management Bulletin LP-7: R122H TWO 1. 4rdenng Information TYPE NUMBER CAPACITY STUIHR CONNECTIONS NOMINAL OUTLET SETTING PROPANEI11 INLET x OUTLET R122H-AAJ 1.100.000 1t44nch x 1124nM NPT 10 pstg (0.69 bar) 1 C=Ct1► is WSW on 30 K* RA7 Dart ode! oresrnae am M% p aoo 1ra.1a 0 a 11. Figure 2. Type R 122H Dimensions WCHEs (MMI LP -Gas Equipment Emerson Process Management RegufatorTechnologles. Inc. USA - Plus PrtdCarM. Texas 75089-1872 USA Telephwte:1(800) 558-5853 Te"hone: l (972) 648.3574 For [urtlter ativrltlatiw visit www.fisheYregutators.com4p The Eeon bpo b a aaftrnM ano sent-, acorn of Emu= Etetbtt Ca IW mw nutks are um popery Clow proapeCsve owners Ffs:sBt m a nrrtk owereo W Father CoelLr n. me . a business or r- - M tee Pass Merrtw RIe FM It po l arm pt[OOCbOn are peeseAtod a7r IRfORil8rlOnZ1 Ohs �N and wvhfle every arlbrl nos Deesc nta68 b BSIstlie tttetr eauT.lcy, they sno nor b Oe eonstrue0 as ractanaas of . express a t+s O> a prOducb er aerstaes dasCmea f:cresn ar their use a appO�bGtly. YVe relBfYe Cie aatst oo nmdalr or aapronrs tAe CBalpels er speebtrztlm ar atm pMOM at ary tttrce tiIRENOtx ra te. Eamm ftem AtraCO M does not sss m respora&4y fbr tha seredw. use or nlamteoa = as any pro*cm Rnsportm ty fbr prWv selea00% use and awanwim of any Eerarson P1008>ti 1carlaporrAft pro" n sol* rlM ate purcrgw EMERSON.. ocWn P== &UVWrWft ftV=Wr ft UX.. M. 2010: M ftM Rwemd Process Management Bulletin 71.1-R622 Type R622 Pressure Reducing Regulator • Protet Scree {4inh r:nnar;jtN/ • Inlet and Outlet Pressure Gauge Taps Figure I. 76,% ..,.,, .. . _.,.. Relief Jeight Introduction Type R622 direct -operated. spring -loaded regulators applications These regulators can be used r:ith provide economical pressure reducing control in natural. manufactured. or propane gases and have the a variety of residential. commercial. and industrial same inlet and outlet pressure capabilities. FISHER ti EMERSON. Bulletin 71.1: R622 Specifications Body Size and End Connection StyleM 112 NPT inlet and outlet Maximum Allowable Inlet Pressure(1) Operating: 125 psig (8,6 bar) Emergency: 125 psig (8,6 bar) Except 1.8 to 2.2-inches w.c. (4 to 5 mbar) spring range which has operating and emergency pressures of 60 psig (4,1 bar) Maximum Allowable Outlet (Casing) Pressure() Operating to Avoid Internal Part Damage: 3 psid (0.21 bar d) above outlet pressure setting Emergency: 20 psi (1 A bar) Outlet Pressure Ranges See Table 1 Orifice Size 1/8-inch (3,2 mm) Orifice Flow Coefficients Wide -Open C. for Relief Sizing: 12.5 Wide -Open Cv for Relief Sizing: 0.36 Cl: 35 IEC Sizing Coefficients xT 0.78 FD: 0.82 FL: 0.89 Flow Capacities See Table 2 Pressure Registration Internal Relief Performance i See Figure 4 Internal Relief Performance Start -to -Discharge is 8 to 22-inches w.c. (20 to 55 mbar) for setpoints from 1.8 to 20-inches w.c. (4 to 50 mbar) Start -to -Discharge is 140 to 200% over setpoint from 20-inches w.c. to 2.2 psig (50 to 152 mbar) Spring Case Vent Connections 3/4 NPT with removable screen Temperature Capabilities(') -200 to 160'F (-29° to 71 °C) Approximate Weight 2.35 pounds (1 kg) Construction Materials Body, Spring Case, Diaphragm Plate, and Orifice: Aluminum Diaphragm, Disk, and O-ring: Nitrile (NBR) Adjusting Screw and Pushpost: Delrin® Closing Cap: ASA Thermoplastic (UV -Ray Resistant) Control Spring: Zinc -plated steel Machine Screw, Spring Seat, and Lever. Zinc -plated steel Valve Stem: Zinc Relief Valve Spring, Relief Spring Retainer, Lever Pin, and Vent Screen: Stainless steel 1 Thep WM% in go &am or any sppecaw stUMM weaum ehaw no be exceww, OeMO m a n irk owneo by E 1. ou Pont 0 Nurma w4 Co. In addition, Type R622 regulators have internal relief across the diaphragm to help minimize overpressure. Any outlet pressure above the start -to -discharge point of the non-adjustable relief valve spring moves the diaphragm off of the relief valve seat, allowing excess pressure to bleed out through the screened spring case vent. Table 1. Outlet Pressure Ranges Specifications The Specifwtions section lists specifications forType R622 Pressure Reducing Regulators. As it originally comes from the factory. specifications for a given regulator are stamped on the spring case nameplate. OUTLET PRESSURE RANGE CONTROL SPRING PART NUMBER CONTROL SPRING COLOR CODE SPRING WIRE DIAMETER. INCHES (mm) SPRING FREE LENGTH. INCHES (mm) 18 W 2.2-Oches w.c. (4 to 5 mbar) T 14453TOO 12 Purple 0051(l.30) 3.40 (864) 5 to 74ncrm w.c. (12 to 17 mbar) T 14398MO 12 t?r8w 0.062 (1.58) 3.40 (86.4) 6.5 to 94 tOM W.C. (16 to 22 mbar) T14399T0012 yew* 0.067 (1.70) 3.61(91.7) 9 to 134HIM W.C. (22 to 32 Mbu) T 144COT0012 Staler 0.072 (1.83) 4.10 (104) 13 to 204nd1es W.C. (32 to 50 mbar) T 14401 TOO 12 Gray 0.080 (2.03) 3.60 (91.4) 16 to 35•Utches w.c. (40 to 87 Mbar) T 14402TOO 12 pmk 0093(2.36) 3.52 (89.4) 1 to 2.2 psig (69 to 152 mbar) T14403TOO12 LV9 Blue 0105(2.67) 3.66 (93.0)