Loading...
HomeMy WebLinkAboutTANK SPECS - 7-20-20Quality Steel Corporation AG/UG Propane Tanks -hEE� 1450 wg. AND UP APPROXIMATE ABOVEGROUND/UNDEGROUNO (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS WATER CAPACITY DIAMETER (OD) HEAD TYPE OVERALL LENGTH OVERALL HEIGHT LEG* WIDTH LEG** SPACING WEIGHT (ft.) **QUANTITY FULL LOAD PER STACK *120 wg. 24" Ellip. 5'-8" 3' 1'-11/2" -101/2" 2'or 01/2 260 1081 96 161 12 *250 wg. 30" HemL 7'40" 30-8" 1'-5" 4'-1V 480 54 9 *320 wg. 30" Heml. 9'-7" 3'-8" i'-5" S' 620 45 9 SW wg. 371/2" Hemi. 20' 4'-2" 18-8" 5' 950 37130 816 1000 wg. 41" HemL 16' 4'-5" 11-82 10'-i" 1,800 17115 615 1450 wg. 461/2" Ellip. 17'-4" 4'-11" 11'-70 2,650 12 4 1990 wg. 461/2" Ellip. 23'-11" 4'-11" HE 16' 3,520 8 4 gmenstons and specifications shown are appradnMe. Individual vessels may nary. • Leg spacing +/- 2•. Leg widths and spat ft may vary based on mfg. location. Check with your salesperson for details. 120, 250, 320 wg. standard tanks - no holes In legs (one center hole an request!. 500 and 1= wg. standard tanks - 2 holes W an center. 1450 wg. and up as shown above. •, Full load and st ut quantities vary by shipping location. Check with your salesperson for details. General Saedfications - Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section Vlll, Division 1. Complies with NFPA 58. - Rated at 250 psig from -20" F to 1250 F. All vessels registered with National Board. - Two service options available: Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/UG dome. Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with steel AG/UG dome. - All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. Updated June 30, 2015 PROPANE CONSTRUCTION NOTES 1. AN pipe and fittings above round and Inside building 9 e building shall be SCH..40 Galvanized- ASTlti/l Al 20 or AGA approved corru aced stainless steel •(C.S.S.T. pipe. g D. 2. All polypipe and fftUhgs shalt be ASTM D25f 3 or ASTM D2517 and shaft be but. %I.. - ufside underground at a depth of 18" ' warning tape and trace p nth . P r wire. . 3. All Pipe and meter locations are approximate and subject to change.- ' 4. Alt polypipe shall be joined by heat fusion or a roved couplings, pp mechanical. • 5. All galvanized pipe shall be threaded. • s- Ali Pipa shall be pressure Nested to 2b # PSI fora period of 24 hours. - r 3HYi 301AU32 U NlY1No0 SYo-! 0!lAOtlOU30HA o• • a, cp cl D� tom• • O •• •� • O • r•' .•• •• • s •� • •I r • p • • i • • •• I •P P•a► ,•. I O 0 • •• •• • • • r•I. 0 O • • • , ice•• p •1c,•0�•.• • t •' ! ' • O so pt • • = 3�3a�s • a�g � • �xo�/3mrafl . . • 3dv b aft NUVA • O _ _ - y� ly 330 WD •I ails +� ilo._bvwsau • • as -•. f t• • s • lobe wnls3NOdwj SIRIV3 300NVoil l -- -- -- MOO worts 06 . AVMV Q3QVNDNM00 • ..9 oa "Z 40. NOIIVI IVISN1 UNVI QNnOWOUBONn ! •. • Ary .