Loading...
HomeMy WebLinkAboutField Density TestWINGERTER LABORATORIES, INC. �` C� Engineering Testing -Inspection Services 1820 NE 144th Street, North Miami, FL 33181 - TELEPHONE: 305-944-3401 FIELD DENSITY TEST FACSIMILE: 305-949-8698 CLIENT: Keys Wi-Fi, Inc. REPORT NO: 1 PROJECT: South Fla Recycle Communication Tower ORDER NO.: 08-1497 CONTRACTOR: TEST DATE: 10/22/2008 PROJECT LOCATION:9901 Range Line Rd., Port St. Lucie, FL TIME IN: 10:00 AM INSPECTOR: Orrane Rhoden PAGE NO.: I of 1 P.O. #: PERMIT #: TIME OUT:10:45 AM Description of 16609- Black Sand with Rock and Wood PROCTOR SUMMARY OF Material: DENSITY TEST INFORMATION RESULTS Retest Dry Probe Optimum Max. Dry Percent Percent Field Fill Field Test Location: of Moisture Density Depth Proctor Moisture Density Field Compaction Test _�o No. Test # Lift Lab No % PCF in. Lab No. % PCF Com action Requirement Status Footer Slab 3744 I F East Comer 15.6 104.0 6 16609 8.5 109.5 95.0 95.0 PASSED 3745 2 F West Comer 19.8 106.0 6 16609 8.5 109.5 96.8 95.0 PASSED 3746 3 F North Comer 16.3 108.0 6 16609 8.5 109.5 98.6 95.0 PASSED 3747 4 F Tank Slab 15.9 106.9 6 16609 8.5 109.5 97.6 95.0 PASSED 3748 5 F Shelter Slab 15.3 107.0 6 16609 8.5 109.5 97.7 95.0 PASSED Remarks: Y 'O 7 N 4 Q O a J �i t7 Field density lest was performed in accordance with ASTM D 2922. This report is submitted as the confidential property of the client. The original of this report was signed and scaled by the herein referenced Registered Engineer in accordance with Rule 61G15 - 18.011 of Florida Administrative Code. Respec b WIN ES, INC. Robert H. Schuler, P.E., P.G Florida License No. 34715