HomeMy WebLinkAboutField Density TestWINGERTER LABORATORIES, INC.
�` C� Engineering Testing -Inspection Services
1820 NE 144th Street, North Miami, FL 33181 - TELEPHONE: 305-944-3401
FIELD DENSITY TEST
FACSIMILE: 305-949-8698
CLIENT: Keys Wi-Fi, Inc.
REPORT NO:
1
PROJECT: South Fla Recycle Communication Tower
ORDER NO.:
08-1497
CONTRACTOR:
TEST DATE:
10/22/2008
PROJECT LOCATION:9901 Range Line Rd., Port St. Lucie, FL
TIME IN:
10:00 AM
INSPECTOR:
Orrane Rhoden
PAGE NO.: I of 1
P.O. #:
PERMIT #:
TIME OUT:10:45 AM
Description of 16609- Black Sand with Rock and Wood
PROCTOR
SUMMARY OF
Material:
DENSITY TEST
INFORMATION
RESULTS
Retest
Dry
Probe
Optimum
Max. Dry
Percent
Percent
Field
Fill
Field Test Location:
of
Moisture
Density
Depth
Proctor
Moisture
Density
Field
Compaction
Test
_�o
No.
Test #
Lift
Lab No
%
PCF
in.
Lab No.
%
PCF
Com action
Requirement
Status
Footer Slab
3744
I
F
East Comer
15.6
104.0
6
16609
8.5
109.5
95.0
95.0
PASSED
3745
2
F
West Comer
19.8
106.0
6
16609
8.5
109.5
96.8
95.0
PASSED
3746
3
F
North Comer
16.3
108.0
6
16609
8.5
109.5
98.6
95.0
PASSED
3747
4
F
Tank Slab
15.9
106.9
6
16609
8.5
109.5
97.6
95.0
PASSED
3748
5
F
Shelter Slab
15.3
107.0
6
16609
8.5
109.5
97.7
95.0
PASSED
Remarks:
Y
'O 7
N 4 Q
O a J
�i
t7
Field density lest was performed in accordance with ASTM D 2922.
This report is submitted as the confidential property of the client.
The original of this report was signed and scaled by the herein referenced Registered
Engineer in accordance with Rule 61G15 - 18.011 of Florida Administrative Code.
Respec b
WIN ES, INC.
Robert H. Schuler, P.E., P.G
Florida License No. 34715