Loading...
HomeMy WebLinkAboutCertificate for Design Load ComplianceRECEIVED COUNTY F L O R I D .A... 1 Project Name: Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Address: w �� AnY WV-E, Permit #: t CM - 02-41 Occupancy Type. SFV— Construction Type: INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. SEP 19 1019 Permitting Department St. Lucie CluON • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Sixth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. RiskCategory:_I X II III IV ExposureCategory:_B X( C _D 4. Design Wind Velocity 160 mph X ASDLRFD End Zone Width: 6 ft S. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +20.0, a1.a Zone 2: +20.0, -55.3 Zone 3: +20.0, -81.7 Zone 4: +34.7, -37.6 Zone 5: +34.7, -46.5 Garage: +28.5, 32.1 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure7_Yes x Not Applicable Explain Why Not: Aspect Ratio <4:1 9. Is A Continuous Load Path Provided?_ YesNot Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie :ments depicted on these plans provide adequate resistance to the design REVIEWED FOR Donald J. NuelleOMPLOANCE Print Name ST. LUCiWe�r�gr�pthNuelle Engineering Ilao a 11634 SW Rowena Street, Port St. Lucie, FL 34987 Company Name & Address Revised 12/07/2018