Loading...
HomeMy WebLinkAboutConstruction DrawingsSUBMITTALS DRAWN BY: APPV'D BY: CONSTRUCTION 0 ISSUED BY SHEET NUMBER SHEET TITLE THE INFORMATION CONTAINED IN THESE DOCUMENTS IS PROPRIETARY BY NATURE. REPRODUCTION OR CAUSING TO BE REPRODUCED THE WHOLE OR ANY PART OF THESE DRAWINGS WITHOUT THE PERMISSION OF MASTEC NETWORK SOLUTIONS IS PROHIBITED. CHECKED BY: MNS PROJECT NO: DATE DESCRIPTION REV CLS JFS 22518-AEC PREPARED FOR: PREPARED BY: 507 AIRPORT BLVD, SUITE 111 MORRISVILLE, NC 27560 SITE NAME: SITE ADDRESS: FA LOCATION: 4/27/2020 6080 PETERSON ROAD FORT PIERCE, FL 34947 PETERSON (FP50) 10152803 RM FLORIDA NO. 82846 RAPHAEL MOHAMED, P.E. 3200 LAKE EMMA ROAD LAKE MARY, FL 32746 PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND ALL SIGNATURES MUST BE VERIFIED ON ANY ELECTRONIC COPIES. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY RAPHAEL MOHAMED, P.E. USING A DIGITAL SIGNATURE. 7/6/2020 RM 5/5/2020 RM 5/22/2020 RM 7/6/2020 RM T-1 TITLE SHEET VICINITY MAP LOCAL MAP PROJECT DIRECTORY APPLICANT: AT&T MOBILITY CORP. 3200 LAKE EMMA ROAD LAKE MARY, FL 32746 TOWER OWNER: SITE DESIGN: SITE SITE 7/6/2020 SHEET DESCRIPTION SHEET INDEX REV. 0 0 0 0 0 TITLE SHEET SITE PLAN TOWER ELEVATION & ANTENNA LAYOUTS EQUIPMENT DETAILS T-1 C-1 C-2 C-3 REV. DATE LTE 4TX4RX/3C/4C/5C(FIRSTNET) /5G NR 1DR-1 CONSTRUCTION DRAWINGS MASTEC NETWORK SOLUTIONS 507 AIRPORT BLVD, SUITE 111 MORRISVILLE, NC 27560 CONTACT: RAPHAEL MOHAMED PHONE: (919) 674-5895 7/6/2020 7/6/2020 7/6/2020 7/6/2020 AMERICAN TOWER CORPORATION 10 PRESIDENTIAL WAY WOBURN, MA 01801 0 7/6/2020 ANTENNA R.C. HEIGHT:125'± STRUCTURE TYPE:SELF SUPPORT STRUCTURE HEIGHT:220'± OCCUPANCY TYPE:TELECOMMUNICATIONS STRUCTURE LAT:N 27.4408194° STRUCTURE LONG:W -80.3867444° JURISDICTION:SAINT LUCIE COUNTY COUNTY:SAINT LUCIE PARCEL ID:231241200000009DATECONTRACTOR DATEOPERATIONS DATENETWORK DATEZONING DATESITE ACQUISITION DATECONSTRUCTION DATERF ENGINEER DATEPROPERTY OWNER APPROVALS 1.THESE PLANS WERE COMPLETED PER PRELIMINARY/APPROVED LTE 4TX4RX/3C/4C/5C(FIRSTNET)/5G NR 1DR-1 RFDS ID#: 3531450 V:1.00 DATED 04/09/2020. CONTRACTOR SHALL REQUEST CURRENT RFDS & WORKBOOK FROM CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION. 2.THESE PLANS WERE COMPLETED PER MASTEC NETWORK SOLUTIONS MOUNT STRUCTURAL ANALYSIS, COMPLETED ON 05/14/2020. PROJECT REFERENCES 1.CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. 2.CONTRACTOR SHALL NOTIFY OWNER FOR ACCESS TO SITE. 3.THIS PROJECT CONSISTS OF: REMOVING (9) 80010765 ANTENNAS, (3) RRUS-11 B12, (3) RRUS-32 B2, (3) RRUS-11 B2, (3) DC6, (3) FIBER TRUNKS. ADDING (9) 800372965 ANTENNAS, (3) RRUS 4415 B30, (3) RRUS 4449 B5/B12, (3) RRUS 4478 B14, (3) RRUS 8843 B2/B66A, (3) RAYCAP DC9, (3) DC POWER CABLE, (3) FIBER CABLE, AND ALL ASSOCIATED WORK. CONSTRUCTION NOTES CARRIER ADDSCOPE TYPE: SITE SUMMARY 1.THIS IS AN UNMANNED FACILITY AND WILL BE USED FOR THE TRANSMISSION OF THE RADIO SIGNALS FOR THE PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE, 2.AT&T CERTIFIES THAT THIS EQUIPMENT FACILITY WILL BE SERVICED ONLY BY AT&T EMPLOYEES AND SUBCONTRACTORS AND THE WORK ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY HANDICAPPED PERSONS. THIS FACILITY WILL BE FREQUENTED ONLY BY SERVICE PERSONNEL FOR REPAIR PURPOSES ONLY. 3.NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION. 4.NO WASTE WATER WILL BE GENERATED AT THIS LOCATION. 5.NO SOLID WASTE WILL BE GENERATED AT THIS LOCATION. PROJECT INFORMATION ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING: CODE COMPLIANCE RF-1 RF EQUIPMENT SCHEDULE GN-1 GENERAL NOTES THIS PROJECT HAS BEEN PERFORMED IN ACCORDANCE WITH THE 2017 FLORIDA BUILDING CODE, 6TH EDITION BASED UPON AN ULTIMATE 3-SECOND GUST WIND SPEED OF 157 MPH. EXPOSURE CATEGORY C WITH A MAXIMUM TOPOGRAPHIC FACTOR, KTZ, OF 1 AND RISK CATEGORY II HAVE BEEN USED FOR THIS PROJECT. ·2017 FLORIDA BUILDING CODE 6TH EDITION ·ANSI/EIA/TIA-222--G (ALLOWED PER EXEMPTION #5 OF 1609.1.1) ASCE 7-10 ·2014 NATIONAL ELECTRICAL CODE ·FLORIDA FIRE PREVENTION CODE 5TH EDITION ·CONTRACTOR TO CONFIRM THAT THE SITE IS COMPLIANT WITH RF WARNING SIGNAGE & EMERGENCY SIGNAGE AS REQUIRED BY THE FEDERAL GUIDELINES CONTAINED WITH OET 65 BULLETIN & AS PER AT&T GUIDELINES07/6/2020G-1 GROUNDING DETAILS 0EQUIPMENT DETAILSC-4 7/6/2020 MOUNT SHEETS ATTACHED SITE NAME: FA #: SITE ADDRESS: 6080 PETERSON ROAD FORT PIERCE, FL 34947 (SAINT LUCIE COUNTY) 10152803 PETERSON PACE #: MRTFL002355 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X XDCDCDCFFFSUBMITTALS DRAWN BY: APPV'D BY: CONSTRUCTION 0 ISSUED BY SHEET NUMBER SHEET TITLE THE INFORMATION CONTAINED IN THESE DOCUMENTS IS PROPRIETARY BY NATURE. REPRODUCTION OR CAUSING TO BE REPRODUCED THE WHOLE OR ANY PART OF THESE DRAWINGS WITHOUT THE PERMISSION OF MASTEC NETWORK SOLUTIONS IS PROHIBITED. CHECKED BY: MNS PROJECT NO: DATE DESCRIPTION REV CLS JFS 22518-AEC PREPARED FOR: PREPARED BY: 507 AIRPORT BLVD, SUITE 111 MORRISVILLE, NC 27560 SITE NAME: SITE ADDRESS: FA LOCATION: 4/27/2020 6080 PETERSON ROAD FORT PIERCE, FL 34947 PETERSON (FP50) 10152803 RM FLORIDA NO. 82846 RAPHAEL MOHAMED, P.E. 3200 LAKE EMMA ROAD LAKE MARY, FL 32746 PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND ALL SIGNATURES MUST BE VERIFIED ON ANY ELECTRONIC COPIES. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY RAPHAEL MOHAMED, P.E. USING A DIGITAL SIGNATURE. 7/6/2020 RM 5/5/2020 RM 5/22/2020 RM 7/6/2020 RM C-1 SITE PLAN THE CONTRACTOR MUST FIELD VERIFY ALL MEASUREMENTS AND FIELD CONDITIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. NOTES: ·CONTRACTOR TO FILL ANY EXISTING GRAVEL AREAS THAT ARE DISTURBED DURING THE COURSE OF CONSTRUCTION, GRAVEL TO MATCH EXISTING. ·THE CONTRACTOR TO ENSURE THAT NO DAMAGE OR DEBRIS OCCURS ON THE ADJACENT PROPERTIES. ·THE CONTRACTOR SHALL SEED ALL DISTURBED AREAS WITH LOW MAINTENANCE NATIVE GRASS AND COVER WITH APPROVED STRAW. ·CONTRACTOR SHALL PROVIDE ALL REQUIRED EROSION CONTROL TECHNIQUES AND BEST MANAGEMENT PRACTICES PER LOCAL AND AND STATE REQUIREMENTS AS APPLICABLE. ·NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL VERIFY NORTH AND INFORM ARCHITECT/ENGINEER OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR MODIFYING THE RAYCAP INSTALLED ON THE TOWER TO ACCOMMODATE THE QUANTITY OF RRU'S. 24"x36" SCALE: 1"=4'-0" 11"x17" SCALE: 1/8" = 1'-0" EXISTING SITE PLAN R CALL FLORIDA 811 ONE CALL - DIAL 811 CALL 3 WORKING DAYS BEFORE YOU DIG 1-800-638-4097 0 3/32" = 1'-0" 4'8'16' EXISTING EQUIPMENT SHELTER (OTHER CARRIER) EXISTING EQUIPMENT PAD (OTHER CARRIER) EXISTING AT&T (11'-5"X20'-0") EQUIPMENT SHELTER EXISTING SELF SUPPORT TOWER EXISTING CHAIN LINK FENCE EXISTING ICE BRIDGE (TYP.) EXISTING UTILITY POLE W/METEREXISTING GENERATOR PAD EXISTING PROPANE TANK PROPOSED (3) DC POWER TRUNKS FROM THE RAYCAP ON GROUND TO RAYCAP ON TOWER - ~ 170'-0" PROPOSED (3) FIBER TRUNK FROM LTE CABINET TO RAYCAP ON TOWER - ~ 170'-0" EXISTING TELCO PEDESTAL 69'-1"±59'-9"±69'-1"±45'-11"±10'-0"±DOUBLE SWINGGATE3'-10"±12'-5"± TOP OF TOWER 250'-0"± AT&T ANTENNAS 125'-0"± OTHER CARRIER 140'-0"± D C B A D AA SUBMITTALS DRAWN BY: APPV'D BY: CONSTRUCTION 0 ISSUED BY SHEET NUMBER SHEET TITLE THE INFORMATION CONTAINED IN THESE DOCUMENTS IS PROPRIETARY BY NATURE. REPRODUCTION OR CAUSING TO BE REPRODUCED THE WHOLE OR ANY PART OF THESE DRAWINGS WITHOUT THE PERMISSION OF MASTEC NETWORK SOLUTIONS IS PROHIBITED. CHECKED BY: MNS PROJECT NO: DATE DESCRIPTION REV CLS JFS 22518-AEC PREPARED FOR: PREPARED BY: 507 AIRPORT BLVD, SUITE 111 MORRISVILLE, NC 27560 SITE NAME: SITE ADDRESS: FA LOCATION: 4/27/2020 6080 PETERSON ROAD FORT PIERCE, FL 34947 PETERSON (FP50) 10152803 RM FLORIDA NO. 82846 RAPHAEL MOHAMED, P.E. 3200 LAKE EMMA ROAD LAKE MARY, FL 32746 PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND ALL SIGNATURES MUST BE VERIFIED ON ANY ELECTRONIC COPIES. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY RAPHAEL MOHAMED, P.E. USING A DIGITAL SIGNATURE. 7/6/2020 RM 5/5/2020 RM 5/22/2020 RM 7/6/2020 RM C-2 TOWER ELEVATION & ANTENNA LAYOUTS THE CONTRACTOR MUST FIELD VERIFY ALL MEASUREMENTS AND FIELD CONDITIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR MODIFYING THE RAYCAP INSTALLED ON THE TOWER TO ACCOMMODATE THE QUANTITY OF RRU'S. NOTES: 1.A STRUCTURAL ANALYSIS SHALL BE PERFORMED BY THE OWNER'S AGENT TO CERTIFY THAT THE EXISTING/PROPOSED COMMUNICATION STRUCTURE AND COMPONENTS ARE STRUCTURALLY ADEQUATE TO SUPPORT ALL EXISTING AND PROPOSED ANTENNAS, COAXIAL CABLES, AND OTHER APPURTENANCES. THE OWNER'S AGENT SHALL FURNISH A CERTIFICATION LETTER SEALED BY A REGISTERED PROFESSIONAL ENGINEER STATING THAT THIS STRUCTURAL ANALYSIS WAS PREPARED IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. 2.ALL ANTENNAS, CABLES, AND MOUNTS SHALL BE INSTALLED IN ACCORDANCE WITH THE STRUCTURAL ANALYSIS REPORT. 3.IF ANY WORK IS PERFORMED AT THIS SITE THAT REQUIRES THE SITE TO BE OFF AIR OR TURNED DOWN, THE SWITCH IS TO BE NOTIFIED 48 HOURS PRIOR TO CONSTRUCTION VIA NCR/CTS. 4.INSTALLATION SHALL BE CONDUCTED BY FIELD CREWS EXPERIENCED IN THE ASSEMBLY AND ERECTION OF RADIO ANTENNAS, TRANSMISSION LINES, AND SUPPORT STRUCTURES. ANTENNA WORK TO BE INSTALLED PER THE REQUIREMENTS OF THE TOWER MANUFACTURER'S SPECIFICATION. 5.ANTENNA AND MOUNT DESIGN MUST COMPLY WITH TIA-EIA-222-G AND ALL LOCAL CODES. 6.CONTRACTOR TO PROVIDE THE PROPER COAX AND JUMPER SUPPORT ATTACHMENTS TO THE TOWER AND ANTENNA MOUNT. 7.REFER TO CURRENT RFDS FOR ADDITIONAL INFO 8.ADJUST ANTENNA MOUNTS AS REQUIRED TO ACHIEVE THE AZIMUTH SPECIFIED AND LIMIT RF SHADOWING 9.UNLESS NOTED OTHERWISE THE CONTRACTOR MUST PROVIDE ALL MATERIAL NECESSARY. 10.CONTRACTOR TO RETURN ALL EXISTING ANTENNAS BEING REMOVED TO AT&T. ·ALL RRU MOUNTING BRACKETS TO BE SUPPLIED BY AT&T ·SEE SHEET C-3 FOR RRU MOUNTING BRACKET DETAILS ·MAINTAIN 3'-0" MIN. SEPARATION BETWEEN FIRSTNET AND LTE 700 ANTENNAS ·INSTALLER TO FIELD VERIFY ANTENNA SEPARATION. ·INSTALLER MAY NEED TO SHIFT ANTENNA MOUNTS AS NEEDED TO OBTAIN REQUIRED MINIMUM SEPARATION BETWEEN ANTENNAS. EXISTING/PROPOSED AT&T ANTENNAS (TYP. 3 SECTORS) EXISTING ANTENNA (OTHER CARRIER-TYP.) EXISTING AT&T EQUIPMENT 24"x36" SCALE: 1"=15'-0" 11"x17" SCALE: 1" = 30'-0" TOWER ELEVATION 24"x36" SCALE: 1"=2'-8" 11"x17" SCALE: 3/16" = 1'-0" FINAL ANTENNA LAYOUT 24"x36" SCALE: 1"=2'-8" 11"x17" SCALE: 3/16" = 1'-0" EXISTING ANTENNA LAYOUT 0 3/16" = 1'-0" 2'4'8' 0 3/16" = 1'-0" 2'4'8' PROPOSED AT&T CABLES ROUTED UP TOWER PER STRUCTURAL ANALYSIS. EXISTING ANTENNA - REMOVE POSITION 1 (1 PER SECTOR, 3 TOTAL) PROPOSED RAYCAP DC9-48-60-24-8C EXISTING SECTOR FRAME MOUNT - REMAIN (1 PER SECTOR, 3 TOTAL) EXISTING RRUS-11 B12 - REMOVE EXSITING RRUS-32 B2 - REMOVE POSITION 3 (1 PER SECTOR, 3 TOTAL) EXISTING (2) RAYCAPS DC9-48-60-24-8C - REMOVE @ 350'-0" EXISTING ANTENNA - REMOVE POSITION 4 (1 PER SECTOR, 3 TOTAL) EXISTING ANTENNA - REMOVE POSITION 3 (1 PER SECTOR, 3 TOTAL) EXISTING RRUS-11 B5 EXISTING RRUS-11 B2 - REMOVE POSITION 4 (1 PER SECTOR, 3 TOTAL) PROPOSED ANTENNA LTE 700/AWS / UMTS 850 POSITION 4 (1 PER SECTOR, 3 TOTAL) PROPOSED RRUS 4449 B5/B12 PROPOSED RRUS 8843 B2/B66A POSITION 3 (1 PER SECTOR, 3 TOTAL) EXISTING SECTOR FRAME MOUNT (1 PER SECTOR, 3 TOTAL) @ 350'-0" EXISTING RRUS-11 B5 PROPOSED RRUS 4478 B14 POSITION 4 (1 PER SECTOR, 3 TOTAL) PROPOSED ANTENNA LTE 700/850/1900 POSITION 3 (1 PER SECTOR, 3 TOTAL) PROPOSED ANTENNA LTE WCS POSITION 1 (1 PER SECTOR, 3 TOTAL) PROPOSED RRUS 4415 B30 POSITION 1 (1 PER SECTOR, 3 TOTAL) 3'-10"±6'-6 "±3'-4"±6'-0"± 3' - 4 " ±7'-6"±PROPOSED MOUNT MODIFICATIONS SEE M.A. REFERENCED ON T-1 SHEET AND ATTACHED MOUNT SHEETS (1 PER SECTOR, 3 TOTAL) NOTE REFER TO CURRENT RFDS FOR EQUIPMENT INFORMATION PROPOSED (2) RAYCAP DC9-48-60-24-8C 12 0 ° B E T A 215°GAMMA350°ALPHA12 0 ° B E T A 215°GAMMA350°ALPHA AB C NEW ANTENNA SPECIFICATIONS ANTENNA MODEL LENGTH (A)WIDTH (B)DEPTH (C)WEIGHT KATHREIN 800372965 78.7"14.8"6.9"66.1 LBS MOUNTING PIPE DOWNTILT BRACKET TOP & BOTTOM 5"R MIN ON COAX JUMPER TAPE AND BRASS TAG MARKINGS SCALE: N.T.S. NEW ANTENNA SPECIFICATIONS NOTES: DETAIL IS DIAGRAMMATIC. CONTRACTOR TO INSTALL RRU'S ON RRU MOUNT BEST SUITED FOR ANTENNA CONFIGURATION. NOTES: DETAIL IS DIAGRAMMATIC. CONTRACTOR TO INSTALL RRU'S ON RRU MOUNT BEST SUITED FOR ANTENNA CONFIGURATION. RRU ERICSSON RRU SUPPORT KIT PART # SXK1250461 1/SXK1091946 2 (OR APPROVED EQUAL) RRU EXISTING ANTENNA MAST PIPE ANTENNA ERICSSON RRU SUPPORT KIT PART # SXK1250461 1/SXK1091946 2 (OR APPROVED EQUAL) EXISTING ANTENNA MAST PIPE ANTENNA RRURRU SCALE: N.T.S RRU MOUNTING DETAIL ELEVATION VIEW SCALE: N.T.S RRU MOUNTING DETAIL PLAN VIEW 1.57"±12.38"30.82"NOTES: RAYCAP VIA AT&T SUPPLIES THE DC9 OVER VOLTAGE PROTECTOR AND PIPE MOUNTING BRACKETS. SUBCONTRACTOR SHALL SUPPLY THE PIPE. ℄ RAYCAP DC9 OVER VOLTAGE PROTECTOR WITH DOME COVER MIN. 2" TO MAX. 4" GALVANIZED PIPE RAYCAP SUPPLIED POLE MOUNTING BRACKETS DOME SECURING BAND CLIP FOR ATTACHING DC9 (OVP) TO BASE ASSEMBLY (TYP) RAYCAP SUPPLIED BASE ASSEMBLY POWER CABLE INGRESS PORTS SCALE: N.T.S. RAYCAP DC9-48-60-24-8C-EV ASSEMBLY SUBMITTALS DRAWN BY: APPV'D BY: CONSTRUCTION 0 ISSUED BY SHEET NUMBER SHEET TITLE THE INFORMATION CONTAINED IN THESE DOCUMENTS IS PROPRIETARY BY NATURE. REPRODUCTION OR CAUSING TO BE REPRODUCED THE WHOLE OR ANY PART OF THESE DRAWINGS WITHOUT THE PERMISSION OF MASTEC NETWORK SOLUTIONS IS PROHIBITED. CHECKED BY: MNS PROJECT NO: DATE DESCRIPTION REV CLS JFS 22518-AEC PREPARED FOR: PREPARED BY: 507 AIRPORT BLVD, SUITE 111 MORRISVILLE, NC 27560 SITE NAME: SITE ADDRESS: FA LOCATION: 4/27/2020 6080 PETERSON ROAD FORT PIERCE, FL 34947 PETERSON (FP50) 10152803 RM FLORIDA NO. 82846 RAPHAEL MOHAMED, P.E. 3200 LAKE EMMA ROAD LAKE MARY, FL 32746 PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND ALL SIGNATURES MUST BE VERIFIED ON ANY ELECTRONIC COPIES. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY RAPHAEL MOHAMED, P.E. USING A DIGITAL SIGNATURE. 7/6/2020 RM 5/5/2020 RM 5/22/2020 RM 7/6/2020 RM C-3 EQUIPMENT DETAILS SUBMITTALS DRAWN BY: APPV'D BY: CONSTRUCTION 0 ISSUED BY SHEET NUMBER SHEET TITLE THE INFORMATION CONTAINED IN THESE DOCUMENTS IS PROPRIETARY BY NATURE. REPRODUCTION OR CAUSING TO BE REPRODUCED THE WHOLE OR ANY PART OF THESE DRAWINGS WITHOUT THE PERMISSION OF MASTEC NETWORK SOLUTIONS IS PROHIBITED. CHECKED BY: MNS PROJECT NO: DATE DESCRIPTION REV CLS JFS 22518-AEC PREPARED FOR: PREPARED BY: 507 AIRPORT BLVD, SUITE 111 MORRISVILLE, NC 27560 SITE NAME: SITE ADDRESS: FA LOCATION: 4/27/2020 6080 PETERSON ROAD FORT PIERCE, FL 34947 PETERSON (FP50) 10152803 RM FLORIDA NO. 82846 RAPHAEL MOHAMED, P.E. 3200 LAKE EMMA ROAD LAKE MARY, FL 32746 PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND ALL SIGNATURES MUST BE VERIFIED ON ANY ELECTRONIC COPIES. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY RAPHAEL MOHAMED, P.E. USING A DIGITAL SIGNATURE. 7/6/2020 RM 5/5/2020 RM 5/22/2020 RM 7/6/2020 RM RF-1 RF EQUIPMENT SCHEDULE *FIBER JUMPER - ROSENBERGER FIBER JUMPER *DC JUMPER - ROSENBERGER SINGLE PAIR DC CABLE ANTENNA AND COAX INFORMATION PROVIDED FROM THE LTE 4TX4RX/3C/4C/5C(FIRSTNET)/5G NR 1DR-1 RFDS ID#: 3531450 V:1.00 DATED 04/09/2020. CONTRACTOR TO VERIFY RF INFO WITH CLIENT PRIOR TO CONSTRUCTION. COAX LENGTHS ARE APPROXIMATE AND MUST BE VERIFIED PRIOR TO CONSTRUCTION. ALL COAX SHALL BE COLOR CODED AT TOP AN BOTTOM JUMPER AND AT TOP OF TOWER BOTTOM OF TOWER, AND INSIDE SHELTER ON MAIN COAX. EACH MAIN COAX SHALL HAVE CORROSION PROOF "ID TAGS" INSTALLED INSIDE THE SHELTER AT THE PORT AND AT THE ANTENNA. QUANTITIES GIVEN ARE TOTAL EXISTING AND PROPOSED. DC / FIBER DEMARCATION BOX RAYCAP DC FIBER DEMARCATION BOX CABLES NOTESMOUNTING HEIGHT MODEL QTY.MODEL SIZE QTY.CABLE LENGTH 125'-0"DC9-48-60-24-8C 3 (6) - #8 AWG TINNED COPPER CONDUCTOR TRUNK 3/8"8 170'-0"± ---ROSENBERGER (24) PAIR FIBER TRUNK 3/8"3 170'-0"± ---(6) - #8 AWG TINNED COPPER CONDUCTOR TRUNK 3/4"3 170'-0"± ------- TOTAL 15 -TOTAL 6 -TOTAL - ANTENNA AND COAX SCHEDULE ANTENNAS CABLES RRU A2 MOD DIPLEXER/TRIPLEXER/FILTER TMA SECTOR AZ RAD CENTER MAKE - MODEL QTY APPROX. ANTENNA SPECS IN INCHES (HXWXD) DOWNTILT MODEL SIZE QTY CABLE LENGTH COLOR CODE MODEL QTY QTY MODEL TWR QTY GRND QTY MODEL QTY ELEC MECH A1 350°215'-0"KATHREIN - 800372965 1 78.7X14.8X6.9 8°0° *FIBER JUMPER - DC6 TO RRU *DC JUMPER - DC6 TO RRU COAX JUMPER - RRU TO ANTENNA 3/8" 7/16" 1/2" 2 1 4 15' 15' 10' 1 RED RRUS 4415 B30 1 ------ A2 -----------2 RED -------- A3 350°215'-0"KATHREIN - 800372965 1 78.7X14.8X6.9 8°0° *FIBER JUMPER - DC6 TO RRU *DC JUMPER - DC6 TO RRU COAX JUMPER - RRU TO ANTENNA 3/8" 7/16" 1/2" 4 4 8 15' 15' 10' 3 RED RRUS 4449 B5/B12 RRUS 8843 B2/B66A 1 1 ------ A4 350°215'-0"KATHREIN - 800372965 1 78.7X14.8X6.9 8°0° *FIBER JUMPER - DC6 TO RRU *DC JUMPER - DC6 TO RRU COAX JUMPER - RRU TO ANTENNA 3/8" 7/16" 1/2" 3 2 8 15' 15' 10' 4 RED RRUS-11 B5 RRUS 4478 B14 1 1 -DBC0108F1V92-1 2 --- B1 120°215'-0"KATHREIN - 800372965 1 78.7X14.8X6.9 8°0° *FIBER JUMPER - DC6 TO RRU *DC JUMPER - DC6 TO RRU COAX JUMPER - RRU TO ANTENNA 3/8" 7/16" 1/2" 2 1 4 15' 15' 10' 1 BLUE RRUS 4415 B30 1 ------ B2 -----------2 BLUE -------- B3 120°215'-0"KATHREIN - 800372965 1 78.7X14.8X6.9 8°0° *FIBER JUMPER - DC6 TO RRU *DC JUMPER - DC6 TO RRU COAX JUMPER - RRU TO ANTENNA 3/8" 7/16" 1/2" 4 4 8 15' 15' 10' 3 BLUE RRUS 4449 B5/B12 RRUS 8843 B2/B66A 1 1 ------ B4 120°215'-0"KATHREIN - 800372965 1 78.7X14.8X6.9 8°0° *FIBER JUMPER - DC6 TO RRU *DC JUMPER - DC6 TO RRU COAX JUMPER - RRU TO ANTENNA 3/8" 7/16" 1/2" 3 2 8 15' 15' 10' 4 BLUE RRUS-11 B5 RRUS 4478 B14 1 1 -DBC0108F1V92-1 2 --- C1 215°215'-0"KATHREIN - 800372965 1 78.7X14.8X6.9 6°0° *FIBER JUMPER - DC6 TO RRU *DC JUMPER - DC6 TO RRU COAX JUMPER - RRU TO ANTENNA 3/8" 7/16" 1/2" 2 1 4 15' 15' 10' 1 GREEN RRUS 4415 B30 1 ------ C2 -----------2 GREEN -------- C3 215°215'-0"KATHREIN - 800372965 1 78.7X14.8X6.9 6°0° *FIBER JUMPER - DC6 TO RRU *DC JUMPER - DC6 TO RRU COAX JUMPER - RRU TO ANTENNA 3/8" 7/16" 1/2" 4 4 8 15' 15' 10' 3 GREEN RRUS 4449 B5/B12 RRUS 8843 B2/B66A 1 1 ------ C4 215°215'-0"KATHREIN - 800372965 1 78.7X14.8X6.9 6°0° *FIBER JUMPER - DC6 TO RRU *DC JUMPER - DC6 TO RRU COAX JUMPER - RRU TO ANTENNA 3/8" 7/16" 1/2" 3 2 8 15' 15' 10' 4 GREEN RRUS-11 B5 RRUS 4478 B14 1 1 -DBC0108F1V92-1 2 --- TOTAL 7/8" COAX -- TOTAL FIBER JUMPER 27 405' TOTAL DC JUMPER 21 315' TOTAL COAX JUMPER 60 600' TOTAL 5/16" RET CABLES 3 510' SCALE: N.T.S GROUNDING DETAIL NOTES: 1.CONTRACTOR SHALL REFER TO AT&T GROUNDING AND BONDING PRACTICE TP-76416. 2.PROVIDE WEATHER PROOFING AND GROUNDING KIT TO BOND DC POWER CABLE SHIELD TO EXTERNAL HATCH PLATE GROUND BAR. 3.PROVIDE GROUND CONNECTION FOR DC POWER CABLE SHIELD TO "P" SECTION OF CRGB WITHIN SHELTER. KEYNOTE LEGEND: 1.SECTOR GROUND BAR (TYP). 2.COLLECTOR GROUND BAR. 3.NEW ANTENNA. 4.SINGLE PAIR FIBER & DC POWER. 5.JUMPER CABLE, 1/2" (TYP). 6.PIPE MOUNT. 7.DC POWER & FIBER TO RAYCAP UNIT. 8.REMOTE RADIO HEAD (RRH) (IF APPLICABLE). 9.DC6 RAYCAP SURGE SUPPRESSOR (IF APPLICABLE). 10.FILTER (IF APPLICABLE) 1.UTILIZE EXISTING AT&T GROUND BARS AND GROUNDING. 2.ADD GROUND BARS IF THERE ARE INSUFFICIENT LUG POSITIONS. 3.REFERENCE AT&T BONDING & GROUNDING PRACTICE TP76416. PROPOSED AT&T RRH PROPOSED RAYCAP FIBER AND DC DISTRIBUTION UNIT PROPOSED LTE PANEL ANTENNA PROPOSED COAX BRIDGE POST #2 SOLID COPPER TINNED IN NMLT PROPOSED GROUND BAR (TYP.PER SECTOR) #2 SOLID COPPER TINNED IN NMLT #2 SOLID COPPER TINNED IN NMLT #2 SOLID COPPER TINNED IN NMLT PROPOSED GROUND BAR @ COAX ENTRY PORT #2 SOLID COPPER TINNED BARE TO GROUND RING #2 SOLID COPPER TINNED IN NMLT (NON-METALLIC LIQUID-TIGHT) (TYP) #2 SOLID COPPER TINNED IN NMLT (NON-METALLIC LIQUID-TIGHT) (TYP) #2 SOLID COPPER TINNED IN NMLT (NON-METALLIC LIQUID-TIGHT) (TYP) 10 9 8 2 7 1 4 3 5 6 SCALE: N.T.S ANTENNA GROUNDING SCHEMATIC PROPOSED GPS ANTENNA SUBMITTALS DRAWN BY: APPV'D BY: CONSTRUCTION 0 ISSUED BY SHEET NUMBER SHEET TITLE THE INFORMATION CONTAINED IN THESE DOCUMENTS IS PROPRIETARY BY NATURE. REPRODUCTION OR CAUSING TO BE REPRODUCED THE WHOLE OR ANY PART OF THESE DRAWINGS WITHOUT THE PERMISSION OF MASTEC NETWORK SOLUTIONS IS PROHIBITED. CHECKED BY: MNS PROJECT NO: DATE DESCRIPTION REV CLS JFS 22518-AEC PREPARED FOR: PREPARED BY: 507 AIRPORT BLVD, SUITE 111 MORRISVILLE, NC 27560 SITE NAME: SITE ADDRESS: FA LOCATION: 4/27/2020 6080 PETERSON ROAD FORT PIERCE, FL 34947 PETERSON (FP50) 10152803 RM FLORIDA NO. 82846 RAPHAEL MOHAMED, P.E. 3200 LAKE EMMA ROAD LAKE MARY, FL 32746 PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND ALL SIGNATURES MUST BE VERIFIED ON ANY ELECTRONIC COPIES. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY RAPHAEL MOHAMED, P.E. USING A DIGITAL SIGNATURE. 7/6/2020 RM 5/5/2020 RM 5/22/2020 RM 7/6/2020 RM G-1 GROUNDING DETAILS SUBMITTALS DRAWN BY: APPV'D BY: CONSTRUCTION 0 ISSUED BY SHEET NUMBER SHEET TITLE THE INFORMATION CONTAINED IN THESE DOCUMENTS IS PROPRIETARY BY NATURE. REPRODUCTION OR CAUSING TO BE REPRODUCED THE WHOLE OR ANY PART OF THESE DRAWINGS WITHOUT THE PERMISSION OF MASTEC NETWORK SOLUTIONS IS PROHIBITED. CHECKED BY: MNS PROJECT NO: DATE DESCRIPTION REV CLS JFS 22518-AEC PREPARED FOR: PREPARED BY: 507 AIRPORT BLVD, SUITE 111 MORRISVILLE, NC 27560 SITE NAME: SITE ADDRESS: FA LOCATION: 4/27/2020 6080 PETERSON ROAD FORT PIERCE, FL 34947 PETERSON (FP50) 10152803 RM FLORIDA NO. 82846 RAPHAEL MOHAMED, P.E. 3200 LAKE EMMA ROAD LAKE MARY, FL 32746 PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND ALL SIGNATURES MUST BE VERIFIED ON ANY ELECTRONIC COPIES. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY RAPHAEL MOHAMED, P.E. USING A DIGITAL SIGNATURE. 7/6/2020 RM 5/5/2020 RM 5/22/2020 RM 7/6/2020 RM GN-1 GENERAL NOTES ABBREVIATIONS: AC ALTERNATING CURRENT AGP ABOVE GROUND POWER AGT ABOVE GROUND TELCO AIC AMPERAGE INTERRUPTION CAPACITY ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BTC BARE TINNED COPPER CONDUCTOR BATT BATTERY CHG CHARGING COMM COMMON DC DIRECT CURRENT DIA DIAMETER DWG DRAWING EC ELECTRICAL CONDUCTOR EMT ELECTRICAL METALLIC TUBING FIF FACILITY INTERFACE FRAME GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM HVAC HEAT/VENTILATION/AIR CONDITIONING IGR INTERIOR GROUNDING RING (HALO) MGB MASTER GROUNDING BAR MIN MINIMUM M/W MICROWAVE MTS MANUAL TRANSFER SWITCH NEC NATIONAL ELECTRICAL CODE OC ON CENTER OHP OVERHEAD POWER OHU OVERHEAD UTILITIES PP POLARIZING PRESERVING PCU PRIMARY CONTROL UNIT PDU PROTOCOL DATA UNIT RECT RECTIFIER RMC RIGID METALLIC CONDUIT RRU REMOTE RADIO UNIT RWY RACEWAY SIAD SMART INTEGRATED ACCESS DEVICE TVSS TRANSIENT VOLTAGE SUPPRESSION SYSTEM TYP TYPICAL UGD UNDERGROUND DUCT UGP UNDERGROUND POWER UGT UNDERGROUND TELCO UPS UNINTERRUPTIBLE POWER SOURCE (DC POWER PLANT) GENERAL NOTES: 1.ALL REFERENCES TO OWNER HEREIN SHALL BE CONSTRUED TO MEAN AT&T OR IT'S DESIGNATED REPRESENTATIVE. 2.ALL WORK PRESENTED ON THESE DRAWINGS MUST BE COMPLETED BY THE CONTRACTOR UNLESS NOTED OTHERWISE. THE CONTRACTOR MUST HAVE CONSIDERABLE EXPERIENCE IN PERFORMANCE OF WORK SIMILAR TO THAT DESCRIBED HEREIN. BY ACCEPTANCE OF THIS ASSIGNMENT, THE CONTRACTOR IS ATTESTING THAT HE DOES HAVE SUFFICIENT EXPERIENCE AND ABILITY, THAT HE IS KNOWLEDGEABLE OF THE WORK TO BE PERFORMED AND THAT HE IS PROPERLY LICENSED AND PROPERLY REGISTERED TO DO THIS WORK IN THE STATE AND/OR COUNTY IN WHICH IT IS TO BE PERFORMED. 3.UNLESS SHOWN OR NOTED OTHERWISE ON THE CONTRACT DRAWINGS, OR IN THE SPECIFICATIONS, THE FOLLOWING NOTES SHALL APPLY TO THE MATERIALS LISTED HEREIN, AND TO THE PROCEDURES TO BE USED ON THIS PROJECT. 4.ALL HARDWARE ASSEMBLY MANUFACTURER'S INSTRUCTIONS SHALL BE FOLLOWED EXACTLY AND SHALL SUPERCEDE ANY CONFLICTING NOTES ENCLOSED HEREIN. 5.IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE TO ENSURE THE SAFETY OF THE STRUCTURE AND ITS COMPONENT PARTS DURING ERECTION AND/OR FIELD MODIFICATIONS. THIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION OF WHATEVER TEMPORARY BRACING, GUYS, OR TIE DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER THE COMPLETION OF THE PROJECT. 6.ALL DIMENSIONS, ELEVATIONS, AND EXISTING CONDITIONS SHOWN ON THE DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR AND THE TESTING AGENCY PRIOR TO BEGINNING ANY MATERIALS ORDERING, FABRICATION, OR CONSTRUCTION WORK ON THIS PROJECT. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER AND THE OWNER'S ENGINEER. THE DISCREPANCIES MUST BE RESOLVED BEFORE THE CONTRACTOR IS TO PROCEED WITH THE WORK. THE CONTRACT DOCUMENTS DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. OBSERVATION VISITS TO THE SITE BY THE OWNER AND/OR THE ENGINEER SHALL NOT INCLUDE INSPECTION OF THE PROTECTIVE MEASURES OR THE CONSTRUCTION PROCEDURES. 7.ALL MATERIALS AND EQUIPMENT FURNISHED SHALL BE NEW AND OF GOOD QUALITY. FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE WITH THE CONTRACT DOCUMENTS ANY AND ALL SUBSTITUTIONS MUST BE PROPERLY APPROVED AND AUTHORIZED IN WRITING BY THE OWNER AND ENGINEER PRIOR TO INSTALLATION. THE CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND QUALITY OF THE MATERIALS AND EQUIPMENT BEING SUBSTITUTED. 8.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT THIS PROJECT AND RELATED WORK COMPLIES WITH ALL APPLICABLE LOCAL STATE, AND FEDERAL SAFETY CODES AND REGULATIONS GOVERNING THIS WORK. 9.ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST EDITION OF THE LOCAL BUILDING CODE. 10.ALL PROPOSED CELLULAR EQUIPMENT AND FIXTURES SHALL BE FURNISHED BY OWNER FOR INSTALLATION BY THE CONTRACTOR, UNLESS SPECIFICALLY NOTED OTHERWISE HEREIN. 11.ACCESS TO THE PROPOSED WORK SITE MAY BE RESTRICTED. THE CONTRACTOR SHALL COORDINATE INTENDED CONSTRUCTION ACTIVITY, INCLUDING WORK SCHEDULE AND MATERIALS ACCESS WITH THE RESIDENT LEASING AGENT FOR APPROVAL. 12.PREFABRICATED BUILDING INSTALLATION SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. STRUCTURAL STEEL NOTES: 1.STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF THE A.I.S.C. SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS- ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN INCLUDING THE COMMENTARY AND THE A.I.S.C. CODE OF STANDARD PRACTICE. 2.STRUCTURAL STEEL PLATES AND SHAPES SHALL CONFORM TO ASTM A26. ALL STRUCTURAL STEEL PIPES SHALL CONFORM TO ASTM A53 GRADE B. ALL STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500 GRADE B. ALL STRUCTURAL STEEL COMPONENTS AND FABRICATED ASSEMBLES SHALL BE HOT DIP GALVANIZED AFTER FABRICATION. 3.WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS) D.1.1/D1.1M:2010. STRUCTURAL WELDING CODE-STEEL WELD ELECTRODES SHALL BE E70XX. 4.ALL COAXIAL CABLE CONNECTORS AND TRANSMITTER EQUIPMENT SHALL BE AS SPECIFIED BY THE OWNER AND IS NOT INCLUDED IN THESE CONSTRUCTION DOCUMENTS THE CONTRACTOR SHALL FURNISH ALL CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. CONNECTION HARDWARE SHALL BE STAINLESS STEEL. 5.ALL REINFORCING STEEL SHALL CONFORM TO ASTM 615 GRADE 60, DEFORMED BILLET STEEL BARS. WELDED WIRE FABRIC REINFORCING SHALL CONFORM TO ASTM A185. 6.THE FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE LATEST A.I.S.C. SPECIFICATIONS. 7.ALL CONNECTIONS NOT FULLY DETAILED ON THESE PLANS SHALL BE DETAILED BY THE STEEL FABRICATOR IN ACCORDANCE WITH SPECIFICATIONS. 8.HOT-DIP GALVANIZE ITEMS SPECIFIED TO BE ZINC-COATED, AFTER FABRICATION WHERE PRACTICAL. GALVANIZING: ASTM A 123, ASTM. A 153/A 153M OR ASTM A 653/A 653M, G90, AS APPLICABLE. 9.REPAIR DAMAGED SURFACES WITH GALVANIZING REPAIR METHOD AND PAINT CONFORMING TO ASTM A 780 OR BY APPLICATION OF STICK OR THICK PASTE MATERIAL SPECIFICALLY DESIGNED FOR REPAIR OF GALVANIZING. CLEAN AREAS TO BE REPAIRED, AND REMOVE SLAG FROM WELDS. HEAT SURFACES TO WHICH STICK OR PASTE MATERIAL IS APPLIED WITH A TORCH TO A TEMPERATURE SUFFICIENT TO MELT THE METALLICS. IN STICK OR PASTE, SPREAD MOLTEN MATERIAL UNIFORMLY OVER SURFACES TO BE COATED AND WIPE OFF EXCESS MATERIAL. 10.CONTRACTOR SHALL FOLLOW THE MANUFACTURER'S INSTRUCTIONS/SPECIFICATIONS IF NO INFORMATION IS CONTAINED IN THESE PLANS OR IF THE MANUFACTURER'S SPECIFICATIONS ARE STRICTER. NOTE: REFER TO AT&T SPECIFICATIONS AS THE CONTROLLING STANDARD FOR PROPOSED CONSTRUCTION. PERMITS: 1.CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS FOR THIS PROJECT FROM ALL APPLICABLE GOVERNMENTAL AGENCIES. 2.ANY PERMITS WHICH MUST BE OBTAINED SHALL BE THE CONTRACTOR'S RESPONSIBILITY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ABIDING BY ALL CONDITIONS AND REQUIREMENTS OF THE PERMITS. 3.ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES AND THE ACI 318-08. "BUILDING REQUIREMENTS FOR STRUCTURAL CONCRETE". 4.THE CONTRACTOR SHALL NOTIFY THE APPLICABLE JURISDICTIONAL (STATE, COUNTY, OR CITY) ENGINEER 24 HOURS PRIOR TO THE BEGINNING OF CONSTRUCTION. 5.ALL DIMENSIONS SHALL BE VERIFIED WITH THE PLANS (LATEST REVISION) PRIOR TO COMMENCING CONSTRUCTION. NOTIFY THE OWNER IMMEDIATELY IF DISCREPANCIES ARE DISCOVERED. THE CONTRACTOR SHALL HAVE A SET OF APPROVED PLANS AVAILABLE AT THE SITE AT ALL TIME WHEN WORK IS BEING PERFORMED. A DESIGNATED RESPONSIBLE EMPLOYEE SHALL BE AVAILABLE FOR CONTACT BY GOVERNING AGENCY INSPECTORS. MISCELLANEOUS: 1.ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA SUPPORT ASSEMBLES SHALL CONFORM TO ASTM A307 OR ASTM 36. ALL STRUCTURAL FASTENERS FOR STRUCTURAL STEEL FRAMING SHALL CONFORM TO ASTM A325. FASTENERS SHALL BE 5/8" MIN. DIA. BEARING TYPE CONNECTIONS WITH THREADS EXCLUDED FROM THE PLANE. ALL EXPOSED FASTENERS, NUTS, AND WASHERS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. ALL ANCHORS INTO CONCRETE SHALL BE STAINLESS STEEL. 2.THE CONTRACTOR SHALL FURNISH ALL CONNECTOR HARDWARE REQUIRED TO SECURE THE CABLES. CONNECTION HARDWARE SHALL BE STAINLESS STEEL. 3.NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL VERIFY NORTH AND NOTIFY CONSULTANT OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. 4.PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTORS FOR GROUND CONDUCTORS. USE STAINLESS STEEL HARDWARE THROUGHOUT. 5.THOROUGHLY REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES REQUIRING GROUND CONNECTIONS. 6.MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. ALL BENDS TO BE A MIN. OF 8" RADIUS. 7.FOR GROUNDING TO BUILDING FRAME AND HATCH PLATE GROUND BARS, USE A TWO-BOLT HOLE NEPA DRILLED CONNECTOR SUCH AS T&B 32007 OR APPROVED EQUAL. 8.FOR ALL EXTERNAL GROUND CONNECTORS, CLAMPS, AND CADWELDS, APPLY A LIBERAL PROTECTIVE COATING OR AN ANTI-OXIDE COMPOUND SUCH AS "NO-OXIDE A" BY DEARBORN CHEMICAL COMPANY. 9.REPAIR ALL METAL SURFACES THAT HAVE BEEN CUT OR DAMAGED BY REMOVING ANY EXISTING RUST AND APPLYING COLD GALVANIZATION. 10.ANTENNA CABLE LENGTHS HAVE BEEN DETERMINED BASED ON THESE PLANS. CABLE LENGTHS LISTED ARE APPROXIMATED AND ARE NOT INTENDED TO BE USED FOR FABRICATION. DUE TO FIELD CONDITIONS, ACTUAL CABLE LENGTHS VARY. CONTRACTOR MUST FIELD VERIFY ANTENNA CABLE LENGTHS PRIOR TO ORDER. SYMBOLS LIST: (SYMBOLS SHOWN MAY NOT BE USED ON THIS PROJECT) CONDUIT RISER UP CONDUIT RISER DOWN GROUNDING CONDUCTOR INDICATES CIRCUIT CONTINUATION ENCLOSED CIRCUIT BREAKER (SIZE AS SHOWN) FUSED DISCONNECT SWITCH (SIZE AS SHOWN) RECEPTACLE PANELBOARD, 120/240 VOLT NOTES: REFERENCE SYMBOLS; DENOTED "SEE NOTE NO.1" INDICATES MOUNTING HEIGHT AFF EXISTING ELEC EQUIPMENT TO REMAIN (S) +18" 1 GENERAL NOTES TO APPLY IN APPLICABLE SITUATIONS ONLY