Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 F,LORPDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-264 It Builder Name: GHO HOMES Street: 3000 SENT PINE DR Permit Office: SAINT LUCIE OU RECEIVED City, Slate, Zip: FORT PIERCE, FL, 34951 Permit Number. Owner: Jurisdiction: Design Location: FL, Fort Pierce County. St. Lucie (Floc a CfmatAW 41n i 1. New construction or existing New (From Plans) 9. Wall Types(3225.6 sqft.) ST. la ion Area I,UCIe �• 2. Single family or multiple family Single-family a. Concrete Block - Ext Ins p MY o b. Frame -Wood, Adjacent R=11.0 248.89 ft' 3. Number of units, if multiple family 1 c. NIA R= ft' 4. Number of Bedrooms 3 d. NIA R= fF 5. Is this a worst case? No 10. Ceiling Types (3097.0 sqft.) Insulation Area a. Under Attic (Vented) R=40.0 3097.00 ft' 6. Conditioned floor area above grade (it') 3097 b. NIA R= ft' Conditioned floor area below grade (ft') 0 . R 11. uctsNIA R ft' 7. Windows(513.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 211 a. U-Factor: Dhl, U=0.62 497.01 It' SHGC: SHGC=0.26 b. U-Factor: Gbl, default 16.00 it' 12. Cooling systems kBtu/hr Efficiency SHGC: Clear, default a. Central Unit 65.5 SEER:16.00 c. U-Factor: NIA ft. SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A W a. Electric Strip Heat 43.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 0.000 R Area Weighted Average SHGC: 0.270 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (3097.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 3097.00 ft' b. Conservation features b. N/A R= ft' None c. NIA R= ft' 15. Credits Pstat Glass/Floor Area: 0.166 Total Proposed Modified Loads: 96.22 PASS Total Baseline Loads: 100.75 I hereby certify that the pl s and ecifications covered by 'ance Review of the plans and o�K$E Srq?E. this calculation are i co th the Florida Energy Code. specifications covered by this calculation indicates compliance r e M ,; p y rr„`_: PREPARED BY: %r with the Florida Energy Code. Before construction is mn,?f•'�, d"':°'..�• �,.0 cwmpleted DATE: 06/28/19 this building will be inspected for compliance with Section 553.908 ,a I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy ode. COD'S�J OWNERIAGENT: % BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/27/2019 4:53 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNT, EOCC FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-264 Bedrooms: 3 User Conditioned Area: 3097 Total Stories: 1 1 Worst Case: No GHO HOMES Rotate Angle: 0 SAINT LUCIE COUNTY Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 3000 BENT PINE DR St. Lucie FORT PIERCE. FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockt 3097 30970 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 3097 30970 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 283.7 ff 0 3097 W _- 0 0 1 ROOF V # Type Roof Gable Roof Materials Area Area Color Solar SA Emitt Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Barrel file 3464 fP 0 ft' Medium 0.4 N 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 3097 W N N CEILING # Ceiling Type Space R-Value Ins Type Area -Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 3097 ft' 0.1 Wood 6/27/2019 4:53 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Concrete Block- Ext Insul Main 4 91 1 10 0 910.8 ft2 0 0 0.3 0 _ 2 NE Exterior Concrete Block - Ed Insul Main 4 9 3 10 0 92.5 ft2 0 0 0.3 0 -3 E Exterior Concrete Block - Ext Insul Main 4 56 9 10 0 567.5 ft2 0 0 0.3 0 -4 SE Exterior Concrete Block- Ext Insul Main 4 4 3 10 0 42.5 ft2 0 0 0.3 0 -5 S Exterior Concrete Block- Ext Insul Main 4 94 9 10 0 947.5 W 0 0 0.3 0 -6 W Exterior Concrete Block - Ext Insul Main 4 41 7 10 0 415.8 ft2 0 0 0.3 0 7 - Garage Frame - Wood Main 11 26 8 9 4 248.9 ft2 0 0.25 0.3 0 WINDOWS Orientation shown is the entered. Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 8.0 ft2 0 ft 0 in 0 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 9.0 ft2 0 ft 0 in 0 It 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft2 0 fl 0 in 0 ft 0 in None None _ 4 n 1 Metal Double (Clear) Yes 0.62 0.26 N 42.7 ft2 0 It 0 in 0 ft 0 in None None _ 5 n 1 Metal Double (Clear) Yes 0.62 0.26 N 24.0 ft2 0 ft 0 in 0 ft 0 in None None _ 6 ne 2 Metal Double (Clear) Yes 0.62 0.26 N 24.7 fl2 0 ft 0 in 0 ft 0 in None None _ 7 e 3 Metal Double (Clear) Yes 0.62 0.26 N 36.0 ft2 0 ft 0 in 0 ft 0 in None None _ 8 e 3 Metal Double (Clear) Yes 0.62 0.26 N 48.0 ft2 0 ft 0 in 0 ft 0 in None None 9 e 3 Metal Double (Clear) Yes 0.62 0.26 N 18.0 ft2 0 ft 0 in 0 ft 0 in None None 10 e 3 Metal Double (Clear) Yes 0.62 0.26 N 120.0 ft' 0 ft 0 in 0 ft 0 in None None 11 e 3 Metal Double (Clear) Yes 0.62 0.26 N 9.0 ft2 0 ft 0 in 0 ft 0 in None None 12 se 4 Metal Double (Clear) Yes 0.62 0.26 N 18.7 ft2 0 ft 0 in 0 R 0 in None None _ 13 s 5 Metal Double (Clear) Yes 0.62 0.26 N 8.0 ft2 0 ft 0 in 0 ft 0 in None None _ 14 s 5 .Metal Double (Clear) Yes 0.62 0.26 N 30.0 ft2 0 ft 0 in 0 ft 0 in None None 15 s 5 Metal Double (Clear) Yes 0.62 0.26 N 9.0 ft2 0 ft 0 in 0 ft 0 in None None 16 s 5 Metal Double (Clear) Yes 0.62 0.26 N 24.0 ft' 0 It 0 in 0 ft 0 in None None 17 w 6 Metal Double (Clear) Yes 0.62 0.26 N 18.0 ff 0 ft 0 in 0 ft 0 in None None 18 w 6 Metal Double (Clear) Yes 0.62 0.26 N 12.0 W 0 ft 0 in 0 ft 0 in None None _ 19 w 6 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft2 0 ft 0 in 0 ft 0 in None None 20 W 6 None Glazed Block No 0.6 0.57 N 16.0 fl2 0 ft 0 in 0 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 700 ft2 700 ft2 64 ft 9.3 ft 1 6/27/2019 4:53 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 3613.2 198.36 373.04 .3446 7 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Can If Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS _ / —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 A Attic 6 426 ft' Attic 305 ft2 Default Leakage Main (Default) (Default) 1 1 1 B Attic 6 211 ft' Attic 96 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablie Cffeiilling Fans: 1Thermosta[it:j1Y an He IXI Jan ji ii [X] Feb fXl Mar LJ j i 1 �Xj Jun rl Jul ! 1 rl Aug i 1 1x1 Sep J� ffXil fiXi] Dee Venting I 1 Jan [ 1 Feb [Xl Mar lnl Apr I ] MaMayy Jun I 1 Jul [ 1 Aug I 1 Sep l OctOct IX] Nov [ ] DDec ec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main Name: Signature: Rating Compant: Date: 6/27/2019 4:53 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 65.5 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 3097 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.619 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.270 14. Heating system: Capacity 43.0 c) Area 7c. 513.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.0 f) Heat recovery unit HealRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 40.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied wi the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed ( r exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based o installed code compliant features. Builder Signature: Date: Address of New Home: 3000 T PI R City/FL Zip: FORT PIERCE, FL 34951 6/27/2019 4:53:24 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1