Loading...
HomeMy WebLinkAboutHealth DepartmenttPa re. APPLICATION #.AP1433591 STATE OF FLORIDA PERMIT #:56-SF-1990379 DEPARTMENT OF HEALTH DOCUMENT #:FI1425997 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:09/16/2019 FEE PAID;660.00 RECEIPT #:56-PID-4134021 APPLICANT: CJ & Amber Frade C a4 AGENT: Upstate Bidrs PROPERTY ADDRESS: 3000 Brocksmith Rd Fort Pierce, FL 34945 MAY 2 7 ZOZ LOT: 8 BLOCK: ST. Lucie County, Permitting SUBDIVISION: Drawdy/Brocksmith Rd I 2329-502-0008-000-3 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND'MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ 1 [O11 TANK SIZE ill 1050.00 [21 [ 1 [271 SURFACE WATER FT [ 1 [021 TANK MATERIAL Concrete [ 1 [281 DITCHES FT [ 1 ,[031 OUTLET DEVICE [ 1 [291 PRIVATE WELLS 100 FT [ 1 [041 MULTI -CHAMBERED ELZj N 1 [ 1 [301 PUBLIC WELLS FT [ 1 (051 OUTLET FILTER ' Polylok PL-122. [ 1 1311 IRRIGATION WELLS FT [ 1 [061 LEGEND 1. 01-011-09DC3 2. [ 1 [321 POTABLE WATER 27 FT [ 1 [071 WATERTIGHT [ 1 [331 BUILDING FOUNDATIONS 6 FT [ 1 [081 LEVEL [ 1 [341 PROPERTY LINES 16 FT [ 1 (091. DEPTH TO LID [ 1 [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ 1 [101 AREA [1] 528 [21 SQFT [ 1 [361 DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER x [ 1 [371 SHOULDERS [ 1 1121 NUMBER OF DRAINLINES 1. 4.00 2. [ 1 [3B1 SLOPES [ 1 [131 DRAINLINE SEPARATION [ 1 [391 STABILIZATION 05/19/2020 [ 1 [141 DRAINLINE SLOPE [ 1 1151 DEPTH OF COVER ADDITIONAL INFORMATION { 1 [161 ELEVATION [ ABOVE / BELOW ]BM 1.00 [ 1 [401 UNOBSTRUCTED AREA [ 1 [171 SYSTEM LOCATION [ 1 [411 STORt1WATER RUNOFF ' [ 1 [18] DOSING PUMPS [ 1 [421 ALARMS [ 1 [191 AGGREGATE SIZE [ 1 [431 MAINTENANCE: AGREEMENT [ 1 [201 AGGREGATE EXCESSIVE _FINES [ 1 [441 BUILDING AREA [ 1 [211 AGGREGATE DEPTH [ 1 [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ 1 [461 FINAL SITE GRADING [ 1 [221 FILL AMOUNT [ I [471 CONTRACTOR DAVID WHITESIDE(ACCUR [ 1 [231 FILL TEXTURE [ 1 [481 OTHER [ 1 [241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ 1 [491 TANK PUMPED [ 1 [26] REPLACEMENT MATERIAL [ 1 [501 TANK CRUSHED 6 FILLED Continents: Comments are on page 2. CONSTRUCTION [ APPROVED / St. Lucie CHO DISAPPROVED 1: Ensvlro9{nental Specl;l ��anJ Ingram(ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED 1: w> St. Lucie CHD Environmental Speclalj t II Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on Following page) /// DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, PAC .. EH Database v 1.0.1 AP1433591 E101990379 DATE: 03/10/2020 DATE: 05/19/2020 Page 2 of 3 APPLICATION #:AP1433591 STATE OF FLORIDA PERtaT #:56-SF-1990379 DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:F11425997 CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:09/16/2019 FEE PAID:660.00 RECEIPT #:56-PID4134021 Violation Number Comment Comments The system is sized for 4 bedrooms with a maximum occupancy of S persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, filter, and 4x11 long TRENCH DF installed. No violations, system ok to cover. Contractor nofified by phone. Needs final inspection for mound system and final site grading. Well inspected at construction inspection. Final system approved. Contractor and building department emailed final approval. DR 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1433591 EID1990379