Loading...
HomeMy WebLinkAboutengineer letter 5989 s. us 1PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 July 01, 2020 Re: Permit# 1504-0412 Re -Roof 5989 S. US 1 Ft. Pierce, Florida To Whom It May Concern: Our office has personally inspected the Re -Roof w/ self -adhered cap sheet and self - adhered base sheet (Polyglass USA FL# 1654.2) over existing 1.9/32" cdx plywood sheathing w/ 8d ring shank nails @ 4" o.c. perimeter and 6" o.c. in the field and the metal drip edge w/ 8d ringshank nails @ 4" o.c. at the above referenced address and find that all work meets the FBC and FRC 2017, 6th Edition and our engineering requirements, and we recommend approval of same. Thank you for your attention to this matter. 4 Sincerely: PAU FLCH INC. Paul W Ich, P.E. Fla. Re . No. 29945 PW:ns