HomeMy WebLinkAboutREVISION - Permit Set REV1 - DigiSign MSAREA CALCULATIONS AIR CONDITIONED AREAS A/C LIVING NON CONDITIONED AREAS GARAGE, STORAGE, MECH. 3,108 SF 662 SF GROSS AREA GROSS AREA 4,213 SF FRONT ENTRY 75 SF REAR PORCH 368 SF DRYWALL SHALL CONFORM WITH SECTION R702.3.1 OF THE FLORIDA BUILDING CODE (RESIDENTIAL). CERAMIC TILE IN TUB/ SHOWER COMPARTMENTS SHALL CONFORM WITH SECTION R702.4 OF THE FLORIDA BUILDING CODE (RESIDENTIAL). WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF NOT GREATER THAN 200 AND A SMOKE-DEVELOPED INDEX OF NOT GREATER THAN 450. ATTIC INSULATION SHALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER WITH A FLAME SPREAD NOT EXCEEDING 25 WITH AN ACCOMPANYING SMOKE-DEVELOPED INDEX NOT EXCEEDING 450. FOAM BLOCK INSULATION SHALL HAVE A FLAME SPREAD OF NOT MORE THAN 75 AND SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450. DRYWALL NOTES 1. ALL CONSTRUCTION SHALL CONFORM TO THE FLORIDA BUILDING CODE, 2017 EDITION. 2. CONTRACTOR TO VERIFY ALL CABINTRY AND FURNITURE SIZES WITH OWNER PRIOR TO ROUGH IN OF PLUMBING & ELECTRIC. 3. PROVIDE FIREBLOCKING AT OPENIGNS AROUND VENTS, DUCTS, CABLES AND WIRES BOTH HORIZONTALLY IN WALL STUDS AND VERTICALLY AT FLOORS & CEILINGS. REFER TO FLORIDA BUILDING CODE, SECTION R302.1 FOR ADDITIONAL REQUIREMENTS. GENERAL NOTES 1. STRUCTURAL LUMBER TO BE HEM-FIR #2 GRADE OR BETTER W/ 1000 PSI MIN. FIBER STRESS VALUE 2. CONCRETE SLABS AND FOOTINGS TO BE 2500 PSI MIN 3. REINFORCING STEEL SHALL BE GRADE 60 OR BETTER W/ 30" MIN. LAP 4. CONCRETE COVER OVER REINFORCING STEEL: A. FOOTINGS: 3" B. BEAMS: 1 1/2" C. COLUMNS: 1 1/2" 5. FILL (SOIL) SHALL BE PLACED IN LIFTS NOT TO EXCEED 12" AND COMPACTED TO A MINIMUM OF 95% MODIFIED PROCTOR DENSITY 6. ALL COMPONENTS OF THIS STRUCTURE HAVE BEEN DESIGNED AND SELECTED TO WITHSTAND FORCES PER THE FLORIDA BUILDING CODE 2017 EDITION 7. DOOR & WINDOW ASSEMBLY COMPONENTS TO BE CERTIFIED BY MANUFACTURER FOR WIND FORCES PER THE FLORIDA BUILDING CODE 2017 EDITION PER WIND LOAD COMPLIANCE DESIGN PRESSURES 8. PRECAST/ PRESTRESSED CONCRETE LINTELS TO HAVE 6" MINIMUM BEARING. REFER TO LINTEL SCHEDULE FOR ADDITIONAL INFORMATION. 9. FOR METHOD OF ATTACHMENT OF DOORS & WINDOWS, REFER TO ATTACHED PRODUCT REVIEW AFFIDAVIT NOTE: ALL SIMPSON STRONG-TIE PRODUCTS IN CONTACT W ITH TREATED LUMBER SHALL HAVE A MINIMUM Z-MAX COATING OR BETTER STRUCTURAL NOTES STUCCO ON RIBLATH OR PAPER BACK SHALL BE ATTACHED TO HORIZONTAL FRAMING PER ASTM C-1063/ ASTM C-926. LATH SHALL BE ATTACHED TO FRAMING MEMBERS WITH CORROSION RESISTANT MATERIALS. ATTACHMENTS SHALL BE SPACED NOT MORE THAN 6" O.C. ALONG SUPPORTS. FASTENERS TO BE USED CAN BE 6d COMMON OR ROOFING NAILS HAVING A MIN. 1 3/4" PENETRATION INTO HORIZONTAL FRAMING MEMBERS OR STAPLES W/ A MIN. 3/4" CROWN ENGAGED NOT LESS THAN (3) STRANDS OF LATH AND MUST PENETRATE THE WOOD FRAMING MEMBERS 1 3/4" MIN. STUCCO NOTES GROUND SNOW LOAD WIND DESIGN Speed4 (mph) Topographic effects SEISMIC DESIGN CATEGORY1 SUBJECT TO DAMAGE FROM Weatheringa Frost line depthb Termitec WINTER DESIGN TEMPe ICE BARRIER UNDERLAYMENT REQUIREDh FLOOD HAZARDSg AIR FREEZING INDEXi MEAN ANNUAL TEMPj TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA NA See Fig. r301.2(4) NA Negligible NA Very Heavy NA NA NA 1. DESIGN CODE: FLORIDA RESIDENTIAL CODE 2017 EDITION USING ASCE 7-10 2. STRUCTURAL DESIGN: ENCLOSED 3. RISK CATEGORY: II EXPOSURE: B 4. DESIGN WIND VELOCITY: 160 MPH 5. MEAN ROOF HEIGHT: 19'-8" ROOF PITCH: 5:12 6. COMPONENTS & CLADDING DESIGN PRESSURE: PSF, BASED ON ACTUAL SQ. FT. @ 30' MPH (WORST CASE) ZONE 1: -22.0 ZONE 2: -32.0 ZONE 3: -60.0 ZONE 4: -28.0 ZONE 5: -34.0 GARAGE: -26.0 7. DESIGN LOADS: FLOOR 40 PSF ROOF/ DEAD: 15 PSF ROOF/ LIVE: 30 PSF 8. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE? YES 9. IS A CONTINUOUS LOAD PATH PROVIDED? YES 10. DESIGN SOIL BEARING PRESSURE: 2000 PSF 11. SOIL BORING TEST REQUIRED? YES CERTIFICATION FOR DESIGN LOAD COMPLIANCE PROJECT NUMBER DATE PROJECT CLIENT ARCHITECT Architectonic Inc CONSULTANTS REGISTRATION REVISIONS 806 DELAWARE AVENUE FORT PIERCE, FLORIDA 34950 T: 772 460 7751 F: 772 460 4244 WWW.ARCHITECTONICINC.COM STATE REG # AA26003348 COPYRIGHT 2017 SHEET TITLE / SHEET NUMBER KEY PLAN A0.00 CONTE RESIDENCE St. Lucie County, Florida GENERAL & CODE INFO GIANCARLO CONTE R18107 07/20/2020 NO. DATE REVISION 1 07/15/20 COORDINATION CONTE RESIDENCE FRONT PERSPECTIVE CONNECTOR SCHEDULE PRODUCT APPROVALS 1 IMPACT IMPACT N/A 1 1 120461.9 1 GARAGE MAN-DOOR 1