Loading...
HomeMy WebLinkAboutREVISION- ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 77/10/2020 4:58 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY GIANCARLO CONTE CONTE RESIDENCE Street: City, State, Zip: PORT ST LUCIE , FL , SE BREVARD AVENUE Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 3108 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.65 250.00 ft² SHGC=0.21 Sgl, U=0.28 96.00 ft² SHGC=0.22 N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 3108.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Polystyrene Bead AggreR=9.0 2430.20 ft² b. Frame - Wood, Adjacent R=11.0 466.00 ft² c. N/A R=f t ² 10. Ceiling Types a. Roof Deck (Unvented)R=20.0 3107.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage 12. Cooling systems 13. Heating systems 14. Hot water systems a. Natural Gas Cap: 1 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:5.543 ft. Area Weighted Average SHGC:0.213 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 3 (346.0 sqft.) (2896.2 sqft.) (3107.0 sqft.) (3108.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 46.5 SEER:16.00 Efficiency k B t u / h r Efficiency 34.0 COP:1.00 f t ² R 6 200 Tankless EF: 0.800 Glass/Floor Area: 0.111 Total Proposed Modified Loads: Total Baseline Loads: 76.68 94.64 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 7-10-2020 07/20/20 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY 1 GIANCARLO CONTE CONTE RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 3108 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , PORT ST LUCIE , St. Lucie SE BREVARD AVENUE Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 3108 30774.2 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 CABANA 64 595.2 No 0 Yes Yes1 Yes 2 BEDROOM 3 156 1450.8 No 0 1 Yes Yes1 Yes 3 CLST 3 20 186 No 0 Yes Yes1 Yes 4 BATH 2 50 465 No 0 Yes Yes1 Yes 5 WIC 2 50 465 No 0 Yes Yes1 Yes 6 BEDROOM 2 195 1813.5 No 0 1 Yes Yes1 Yes 7 HALL 36 334.8 No 0 Yes Yes1 No 8 POWDER 25 250 No 0 Yes Yes1 No 9 DEN CLST 28 260.4 No 0 Yes Yes1 Yes 10 DEN 182 1820 No 0 Yes Yes1 Yes 11 FOYER 91 910 No 0 Yes Yes1 Yes 12 DINING 238 2380 No 0 Yes Yes1 Yes 13 PANTRY 30 279 No 0 Yes Yes1 No 14 GREAT ROOM 481 5291 No 0 Yes Yes1 Yes 15 NOOK 140 1400 No 0 Yes Yes1 Yes 16 KITCHEN 456 4560 Yes 0 Yes Yes1 No 17 MASTER BEDROO 371 3710 No 0 1 Yes Yes1 Yes 18 M WIC 171 1590.3 No 0 Yes Yes1 Yes 19 M BATH 156 1450.8 No 0 Yes Yes1 Yes 20 LAUNDRY 100 930 No 0 Yes Yes1 No 21 MUDROOM 68 632.4 No 0 Yes Yes1 No 7/10/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 64 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -023 ft CABANA 2 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -019 ft BEDROOM 3 3 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3 4 50 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2 5 50 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft WIC 2 6 195 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -028 ft BEDROOM 2 7 36 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 8 25 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft POWDER 9 28 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft DEN CLST 10 182 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -017 ft DEN 11 91 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -09 ft FOYER 12 238 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -021 ft DINING 13 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft PANTRY 14 481 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -023 ft GREAT ROOM 15 140 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -023.2 ft NOOK 16 456 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft KITCHEN 17 371 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -028 ft MASTER BEDRO 18 171 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -028 ft M WIC 19 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -012 ft M BATH 20 100 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LAUNDRY 21 68 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft MUDROOM # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Metal 3367 ft² Light 0.6 20 22.6______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 3108 ft² N N0 7/10/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)20 64 ft² 0.1 Wood______CABANA Blown 2 Under Attic (Unvented)20 156 ft² 0.1 Wood______BEDROOM 3 Blown 3 Under Attic (Unvented)20 20 ft² 0.1 Wood______CLST 3 Blown 4 Under Attic (Unvented)20 50 ft² 0.1 Wood______BATH 2 Blown 5 Under Attic (Unvented)20 50 ft² 0.1 Wood______WIC 2 Blown 6 Under Attic (Unvented)20 195 ft² 0.1 Wood______BEDROOM 2 Blown 7 Under Attic (Unvented)20 36 ft² 0.1 Wood______HALL Blown 8 Under Attic (Unvented)20 25 ft² 0.1 Wood______POWDER Blown 9 Under Attic (Unvented)20 28 ft² 0.1 Wood______DEN CLST Blown 10 Under Attic (Unvented)20 182 ft² 0.1 Wood______DEN Blown 11 Under Attic (Unvented)20 90 ft² 0.1 Wood______FOYER Blown 12 Under Attic (Unvented)20 238 ft² 0.1 Wood______DINING Blown 13 Under Attic (Unvented)20 30 ft² 0.1 Wood______PANTRY Blown 14 Under Attic (Unvented)20 481 ft² 0.1 Wood______GREAT ROOM Blown 15 Under Attic (Unvented)20 140 ft² 0.1 Wood______NOOK Blown 16 Under Attic (Unvented)20 456 ft² 0.1 Wood______KITCHEN Blown 17 Under Attic (Unvented)20 371 ft² 0.1 Wood______MASTER BEDRO Blown 18 Under Attic (Unvented)20 171 ft² 0.1 Wood______M WIC Blown 19 Under Attic (Unvented)20 156 ft² 0.1 Wood______M BATH Blown 20 Under Attic (Unvented)20 100 ft² 0.1 Wood______LAUNDRY Blown 21 Under Attic (Unvented)20 68 ft² 0.1 Wood______MUDROOM Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 9 0CABANA04013 9N Concrete Block - Polystyrene 0.60Exterior121.3 ft² ____ 2 9 0CABANA0405 9E Concrete Block - Polystyrene 0.60Exterior46.7 ft² ____ 3 9 0CABANA0405 9W Concrete Block - Polystyrene 0.60Exterior46.7 ft² ____ 4 9 0BEDROOM 3 0407 9E Concrete Block - Polystyrene 0.60Exterior65.3 ft² ____ 5 9 0BEDROOM 3 04012 9W Concrete Block - Polystyrene 0.60Exterior112.0 ft² ____ 6 9 0CLST 3 0402 9W Concrete Block - Polystyrene 0.60Exterior18.7 ft² ____ 7 9 0BATH 2 0405 9W Concrete Block - Polystyrene 0.60Exterior46.7 ft² ____ 8 9 0WIC 2 0405 9W Concrete Block - Polystyrene 0.60Exterior46.7 ft² ____ 9 9 0BEDROOM 2 04013 9S Concrete Block - Polystyrene 0.60Exterior121.3 ft² ____ 10 9 0BEDROOM 2 04015 9W Concrete Block - Polystyrene 0.60Exterior140.0 ft² ____ 11 9 0DEN CLST 0402 9S Concrete Block - Polystyrene 0.60Exterior18.7 ft² ____ 12 9 0DEN CLST 0404 9W Concrete Block - Polystyrene 0.60Exterior37.3 ft² ____ 13 9 0DEN0004 10E Concrete Block - Polystyrene 0.60Exterior40.0 ft² ____ 14 9 0DEN00013 10S Concrete Block - Polystyrene 0.60Exterior130.0 ft² ____ 15 9 0FOYER0009 10S Concrete Block - Polystyrene 0.60Exterior90.0 ft² ____ 16 9 0DINING00017 10S Concrete Block - Polystyrene 0.60Exterior170.0 ft² ____ 17 9 0DINING0004 10W Concrete Block - Polystyrene 0.60Exterior40.0 ft² ____ 18 11 0DINING00013 10E Frame - Wood 0.60.25Garage130.0 ft² ____ 19 11 0PANTRY0406 9S Frame - Wood 0.60.25Garage56.0 ft² ____ 7/10/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 20 11 0PANTRY0404 9E Frame - Wood 0.60.25Garage37.3 ft² ____ 21 9 0GREAT ROO 00023 11N Concrete Block - Polystyrene 0.60Exterior253.0 ft² ____ 22 9 0NOOK00013 10N Concrete Block - Polystyrene 0.60Exterior130.0 ft² ____ 23 9 0NOOK0006 10W Concrete Block - Polystyrene 0.60Exterior60.0 ft² ____ 24 9 0NOOK0034 10NW Concrete Block - Polystyrene 0.60Exterior42.5 ft² ____ 25 9 0MASTER BE 00020 10N Concrete Block - Polystyrene 0.60Exterior200.0 ft² ____ 26 9 0MASTER BE 0008 10W Concrete Block - Polystyrene 0.60Exterior80.0 ft² ____ 27 9 0M WIC 0409 9N Concrete Block - Polystyrene 0.60Exterior84.0 ft² ____ 28 9 0M WIC 04019 9E Concrete Block - Polystyrene 0.60Exterior177.3 ft² ____ 29 9 0M BATH 04012 9E Concrete Block - Polystyrene 0.60Exterior112.0 ft² ____ 30 11 0M BATH 04013 9S Frame - Wood 0.60.25Garage121.3 ft² ____ 31 11 0MUDROOM0408 9S Frame - Wood 0.60.25Garage74.7 ft² ____ 32 11 0MUDROOM0405 9E Frame - Wood 0.60.25Garage46.7 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .39 24 ft² None______S FOYER 83 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 E Low-E Single 0.65 0.21 16.0 ft² 4 ft 0 in 1 ft 4 in NoneMetal None______Yes2 N 2 W Low-E Single 0.65 0.21 9.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes3 N 3 W Low-E Single 0.65 0.21 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes5 N 4 W Low-E Single 0.65 0.21 9.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes7 N 5 S Low-E Single 0.65 0.21 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes9 N 6 W Low-E Single 0.65 0.21 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes10 N 7 S Low-E Single 0.65 0.21 36.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes14 N 8 S Low-E Single 0.65 0.21 3.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes15 N 9 S Low-E Single 0.65 0.21 36.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes16 N 10 N Low-E Single 0.28 0.22 96.0 ft² 12 ft 0 in 1 f t 4 in NoneVinyl None______Yes21 N 11 N Low-E Single 0.65 0.21 36.0 ft² 5 ft 0 in 1 ft 4 in NoneMetal None______Yes22 N 12 NW Low-E Single 0.65 0.21 18.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes24 N 13 N Low-E Single 0.65 0.21 30.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes25 N 14 E Low-E Single 0.65 0.21 12.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes29 N 7/10/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 660 ft² 660 ft² 49 ft 9 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 3590.3 7197.1.00044Wholehouse .1662370.68Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 34 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 46.5 kBtu/hr 1395 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Natural Gas 0.8 1 gal 55.1 gal 120 deg None______Tankless Exterior FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 200 ft² Attic 20 ft² Default Leakage Garage (Default) c______1 1 (Default) c 7/10/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 CABANA Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 POWDER Default(8 lbs/sq.ft.f t ² f t 0.3 DEN CLST Default(8 lbs/sq.ft.f t ² f t 0.3 DEN Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER Default(8 lbs/sq.ft.f t ² f t 0.3 DINING Default(8 lbs/sq.ft.f t ² f t 0.3 PANTRY Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT ROOM Default(8 lbs/sq.ft.f t ² f t 0.3 NOOK Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY Default(8 lbs/sq.ft.f t ² f t 0.3 MUDROOM 7/10/2020 4:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������