Loading...
HomeMy WebLinkAboutREVISION letter and plans OFFICE USE ONLY: DATE FILED: _____________________________ PERMIT # _______________________________ REVISION FEE: ___________________________ RECEIPT # ______________________________ ______________________________________________________________________________________________ PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: ___________________________________________________________________________________ ___________________________________________________________________________________ DETAILED DESCRIPTION OF PROJECT REVISIONS: ___________________________________________________________________________________ ___________________________________________________________________________________ CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ______________________ ST. LUCIE CO CERT. #: ____________ BUSINESS NAME: _________________________________________________________________ QUALIFIERS NAME: ________________________________________________________________ ADDRESS: _______________________________________________________________________ CITY: _______________________ STATE: _______________ ZIP: _______________________ PHONE (DAYTIME): ________________________ FAX: _____________________________ OWNER/BUILDER INFORMATION: NAME: ____________________________________________________________________________ ADDRESS:__________________________________________________________________________ CITY: _____________________________ STATE: __________ ZIP: __________________ PHONE (DAYTIME: ___________________________ FAX: _____________________________ ARCHITECT/ENGINEER INFORMATION: NAME: ____________________________________________________________________________ ADDRESS: _________________________________________________________________________ CITY: _____________________________ STATE: ____________ ZIP: ___________________ PHONE (DAYTIME): ___________________________ FAX: ____________________________ SLCCC: 9/23/09 Revised 06/30/17 CIVIL, STRUCTURAL & WATER RESOURCE ENGINEERING 3370 Capital Circle NE Suite J, Tallahassee, FL 32308 │ 850-894-4521 │ fax 850-224-0505 Ebbstone.com July 22, 2020 Andrew Manero St. Lucie County Planning & Developmental Services RE: Revision Request to Change Compliance Method Level from 3 to 1 4006 Avenue P Fort Pierce, Florida House Repair Plans Dear Mr. Manero, For your review Jacques Registe has provided the following documentation for the repair of the referenced property. • Revised Signed and Sealed Repair Plans Please review the attached documentation and give me call if you have any questions at (850) 544-1402. Reason for revised plans: The original plans were based on complete or more than 50% of floor plan replacement. However, during the repair, I discovered that only 10 to 14% of the floor plan was modified due a toilet leak. 4 - 2x8 joists and 4 sheets of plywood were replaced as can testify by Ms. Wanda Gahn during her first inspection of the work. Please review and let me know. Sincerely, Ebbstone, Inc. Jacques Registe, P.E. Chief Engineer 10 SF ULTIMATE DESIGN WIND PRESSURES (PSF) ZONE 2 (ROOF 2) 3 (ROOF 3) 40.0/-55.21 (ROOF 1)32.3/-51.4 100 SF 4 (WALL 4)52.3/-56.1 5 (WALL 5)59.0/-74.2 52.3/-60.8 40.0/-85.6 32.3/-66.6 32.3/-97.0 EFFECTIVE WIND AREA EDGE ZONE (a) = 3.0’ 59.0/-62..8 40.0/-119.9 5 5 55 44 3 3 3 32 2 2 2 2 2 2 2 2 2 1 1 1 1 a a a a a a a a a 1) ALL WINDOWS SHALL MEET THE WIND PRESSURE SHOWN ON THIS SHEET P.E. LICENSE NUMBER 43397 EBBSTONE, INC. 3370 CAPITAL CIRCLE NE, SUITE J TALLAHASSEE, FL 32308 CERTIFICATE OF AUTHORIZATION 9292 JACQUES REGISTE, P.E. (5X5 AND LARGER) POSTS AND TIMBERS-----------Fb (BENDING) 850 PSI BEAMS AND STRINGERS----------Fb (BENDING) 975 PSI (2X2 THROUGH 4X4) E, 1,600,000 PSI LIGHT FRAMING---------------Fb (BENDING) 1500 PSI ALLOWABLE STRESS MATERIAL SHALL BE SOUTHERN PINE, COMPLYING WITH THE FOLLOWING MIN.2. ALL LUMBER SHALL CONFORM TO AMERICAN SOFTWOOD LUMBER STANDARD PS-20.1. DIMENSIONAL LUMBER (NEW) CONTRACTOR SHALL INSTALL ALL CONNECTORS IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS.3. UNLESS OTHERWISE NOTED. CONTRACTOR SHALL USE ALL FASTENERS REQUIRED TO OBTAIN MAXIMUM PUBLISHED CONNECTOR LOADS2. ALL CONNECTORS AND FASTENERS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. 1. CONNECTORS FOR WINDOWS SPECIFICATIONS. COVERSION FACTOR OF 0.6 USING ASD CAN BE USED ULTIMATE WIND PRESSURE FROM ASCE 7-10 WAS USED. NOTE: SHALL BE RESOLVED BY THE ENGINEER. WEATHER OR NOT THEY ARE KEYED IN AT EACH LOCATION. QUESTION REGARDING THE APPLICABILITY OF TYPICAL DETAILS 6. DETAILS LABELED "TYP." APPLY TO ALL SITUATIONS THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY REFERENCED, NOTIFIED OF ANY PROPOSED MODIFICATIONS. SHALL ADJUST DIMENSIONS AND DETAILS AS REQUIRED TO FIT EXISTING CONDITIONS. THE ARCHITECT/ENGINEER SHALL BE PROVIDE OVERALL DIMENSIONAL PARAMETERS AND DESCRIBE ELEMENTS TO BE CONSTRUCTED. THE CONTRACTOR WITHOUT THE SPECIFIC WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER. DESIGN INFORMATION SHOWN ON THE DRAWINGS ANY DISCREPANCIES OR INCONSISTENCIES. NO CHANGES OF INFORMATION SHOWN ON THE DRAWINGS SHALL BE MADE 5. VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY THE ARCHITECT/ENGINEER OF TOPOGRAPHY FACTOR-------1.0 WIND DIRECTIONAL FACTOR---Kd= 0.85 MEAN ROOF HIGH---------19.5 FEET INTERNAL PRESSURE COEFFICIENT--GCP+/-0.55 (ENCLOSED) CLADDING AND COMPONENT--B EXPOSURE -MWFRS-------B IMPORTANCE FACTOR ------------------ I=1.0 RISK CATEGORY ------------------- III NORMAL WIND SPEED ------------------- V=123 MPH ULTIMATE DESIGN WIND SPEED ------------- 158 MPH GOVERNING CODE -------------------- ASCE 7-10 DESIGN WIND LOADS4. DECK LOAD --------------100 PSF ROOF LIVE LOAD --------- 20 PSF BUILDING LIVE LOAD--------- 40 PSF 3. DESIGN SUPERIMPOSED LOADS AND TEMPORARY BRACING OR SUPPORT. PRIOR TO COMPLETION, THE CONTRACTOR IS RESPONSIBLE FOR STABILITY 2. THE STRUCTURE IS DESIGNED TO BE STRUCTURALLY SOUND WHEN COMPLETED. FLORIDA BUILDING CODE 2017 (EXISTING BUILDING). FEDERAL, STATE, LOCAL CODES, STANDARDS, REGULATIONS AND LAW. THE GOVERNING CODE FOR THIS PROJECT IS THE 1. CONSTRUCTION IS TO COMPLY WITH THE REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ALL OTHER APPLICABLE GENERAL S-7 INTERIOR REPAIR PLANS S-6 CONNECTION DETAILS S-5 STAIRS AND DECK DETAILS S-4 FOUNDATION LAYOUT S-3 EXISTING HOUSE ELEVATION S-2 FLOOR LAYOUT S-1 GENERAL NOTES INDEX OF DRAWINGS STATE OFPR OFE S SI ONAL ENGINERJACQUES R E GI STE No 43397 ENOTICE: THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.WINDOW SCHEDULE PLUMBING SYSTEM. NO ALTERATION TO TEH EXISTING ELETRICAL OR COMPLIANCE METHOD LEVEL 1 SHOWN IN THIS SET OF PLANS. ALL REPAIRS SHALL BE DONE PER THE DETAILS 5) REPAIR STAIRWAY AND DECK 4) REPAIR SIDING 3) INSTALL KITCHEN SINK AND COUNTER TOP 2) REPAIR BATHROOMS 1) REPLACE 1 - WINDOW SCOPE OF WORK: ASCE 7-10 COMPONENT AND CLADDING DESIGN PRESSURES J.R. 01-20 K.G. 01-20 REF. DWG. NO. SHEET NO. SHEET TITLE: PROJECT NAME: DRAWN BY: CHECKED BY: DESIGNED BY: CHECKED BY: REVISIONS DATE BY DESCRIPTION DATE BY DESCRIPTION $USER$$DATE$$TIME$$FILE$ J.R. 01-20 J.R. 01-20 S-1 RENOVATION PLANS GENERAL NOTES 7/21/2020 JR COMPLIANCE LEVEL AND DECK DETAILS1 7/21/2020 JR 1 EXISTING FLOOR LAYOUT AND STAIRS DETAILS ON ANY ELECTRONIC COPIES. AND THE SIGNATURE MUST BE VERIFIED NOT CONSIDERED SIGNED AND SEALED PRINTED COPIES OF THIS DOCUMENT ARE ON THE DATE ADJACENT TO THE SEAL SIGNED AND SEALED BY THIS ITEM HAS BEEN DIGITALLY 4006 Avenue P, Fort Pierce Florida (Typ) 6"X6" Columns (Typ) 6"X6" Columns 2-2X10 2 - 2X10 (TYP) 4-NEW 2X8 @ 12" o.c. P.E. LICENSE NUMBER 43397 EBBSTONE, INC. 3370 CAPITAL CIRCLE NE, SUITE J TALLAHASSEE, FL 32308 CERTIFICATE OF AUTHORIZATION 9292 JACQUES REGISTE, P.E. (TYP) Ex. 2X8 JOIST @ 16" O.C. (TYP) @ 16" O.C. Ex. 2X8 JOIST (Typ) 10"X10" Columns (Typ) 10"X10" Columns INTERSECTION (TYP.) H2.5A @ JOIST/BEAM SIMPSON STRONG TIE @ 16" O.C. (TYP.) 4 NEW 2X8 JOISTS NOTICE: THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.(TYP) Existing blocking NEW 2X10 BEAM " X 5" LAG BOLTS (TYP)2 13 BOLTS (TYP) " X 5" LAG 2 13 4’-0"11’-8"11’-6"6’-0"8’-0"7’-6"7’-4"7’-6"7’-1"10’-0"11’-6"3- 6"X6" PT columns10’-0"11’-6"3- 6"X6" PT columns 4’-0"11’-8"11’-6" EXISTING BEAM LAYOUT EXISTING FLOOR JOIST LAYOUT J.R. 01-20 K.G. 01-20 REF. DWG. NO. SHEET NO. SHEET TITLE: PROJECT NAME: DRAWN BY: CHECKED BY: DESIGNED BY: CHECKED BY: REVISIONS DATE BY DESCRIPTION DATE BY DESCRIPTION $USER$$DATE$$TIME$$FILE$ J.R. 01-20 J.R. 01-20 S-2 RENOVATION PLANS FLOOR LAYOUT 7/21/2020 JR COMPLIANCE LEVEL AND DECK DETAILS1 7/21/2020 JR 1 EXISTING FLOOR LAYOUT AND STAIRS DETAILS 1 1 4006 Avenue P, Fort Pierce Florida 2X4 PT TRIM LAPPED SIDING HARDI-PLANK 2X4 PT TRIM WOOD POST 4X4 P.T 6"X6" Post8"X8" Post Ground SHINGLE ROOF LAPPED SIDING PLANK P.E. LICENSE NUMBER 43397 EBBSTONE, INC. 3370 CAPITAL CIRCLE NE, SUITE J TALLAHASSEE, FL 32308 CERTIFICATE OF AUTHORIZATION 9292 JACQUES REGISTE, P.E.NOTICE: THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.BE REPLACED WINDOW TO FRONT VIEW SIDE VIEW N.T.S. N.T.S. J.R. 01-20 K.G. 01-20 REF. DWG. NO. SHEET NO. SHEET TITLE: PROJECT NAME: DRAWN BY: CHECKED BY: DESIGNED BY: CHECKED BY: REVISIONS DATE BY DESCRIPTION DATE BY DESCRIPTION $USER$$DATE$$TIME$$FILE$ J.R. 01-20 J.R. 01-20 S-3 EXISTING HOUSE ELEVATION RENOVATION PLANS EXISTING HOUSE ELEVATION 4006 Avenue P, Fort Pierce Florida (Typ) 6"X6" Columns STAIRS TO BE REPAIRED DECK TO BE REPAIRED P.E. LICENSE NUMBER 43397 EBBSTONE, INC. 3370 CAPITAL CIRCLE NE, SUITE J TALLAHASSEE, FL 32308 CERTIFICATE OF AUTHORIZATION 9292 JACQUES REGISTE, P.E.NOTICE: THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.4’-0"11’-8"11’-6"6’-0"8’-0"7’-6"7’-4"7’-6"7’-1"10’-0"11’-6"3- 6"X6" PT columns4’-0"11’-8"11’-6"6’-0"8’-0"7’-6"7’-4"7’-6"7’-1"10’-0"11’-6"3- 6"X6" PT columns(Typ) 8"X8" Columns BE REPAIRED KITCHEN TO REPAIRED BATH TO BE REPAIRED BATH TO BE BE REPLACED WINDOW TO 2 SLIDIND GLASS DOORS BE REPAIRED KITCHEN TO REPAIRED BATH TO BE (Typ) 10"X10" Columns (EXIST.) TO BE REPAIRED HATCHED AREA (16’X8’) EXISTING FOUNDATION LAYOUT EXISTING HOUSE PLANHATCHED AREA TO BE REPAIRED NOTE: A B J.R. 01-20 K.G. 01-20 REF. DWG. NO. SHEET NO. SHEET TITLE: PROJECT NAME: DRAWN BY: CHECKED BY: DESIGNED BY: CHECKED BY: REVISIONS DATE BY DESCRIPTION DATE BY DESCRIPTION $USER$$DATE$$TIME$$FILE$ J.R. 01-20 J.R. 01-20 S-4 S-5 S-5 B S-5 A S-5 ENTRY DOOR EXIST. RENOVATION PLANS FOUNDATION LAYOUT C C 4006 Avenue P, Fort Pierce Florida TOP AND THE BOTTOM WITH A 30 CUT AT THE 2"X2" PICKETS 5-1/2"O.C. EXISTING GROUND TOP AND THE BOTTOM WITH A 30 CUT AT THE 2"X2" PICKETS 5-1/2"O.C. BEVELED EDGES 2"X4" RAIL WITH SCREWS TYP.(H.D.G.)2" #8 4"X4" P.T. STANTION 6’-0" (TYP)6’-0" (TYP) PILING) SCREWS PER (H.D.G.)(2)- PILING, (SECURED WITH OUTSIDE EDGE OF THE A 1/4" OVER HANG THE 2"X6" TOP PLATE, WITH 8"X8" POSTS 8"X8" POSTS CONNECTIONS. TOP AND BOTTOM OF THE POST WITH NUTS AND WASHERS AT THE PILING CONNECTIONS AT ALL JOIST & WASHERS BOLTS WITH NUTS AND THRU INTERSECTION (TYP.) H2.5A @ JOIST/BEAM SIMPSON STRONG TIE (ACQ OF 2.5 LBS./IN.) (TYP.) OF 6’ BELOW NATURAL GRADES 6"X6" POSTS WITH A MIN. DEPTH CROSS BEAM 2x8 P.T. JOIST (TYP.) (5) 2x8 P.T.(TYP.)2"EXISTING GROUND 1’-0"1’-0"1’-0" 4’-0" 2"x6" DECKINGAND WASHERS TYP. MACH. BOLTS W/ NUT WITH 2-1/2"X8" HDG 2X8 BEAMS SECURED 2-2X6 TREADS (3 TOTAL) STRINGER 2X12 P.T. 36"11""4171’-0" EXISTING POST EXISTING POST 4"X4" P.T. STANTION AT ALL JOIST WASHERS BOLTS WITH NUTS AND THRU 3’-6"AT TOP & BOTTOM OF POST (TYP.) BOLTS WITH NUTS AND WASHERS 2X4 RAIL WITH 2X6 P.T. P.E. LICENSE NUMBER 43397 EBBSTONE, INC. 3370 CAPITAL CIRCLE NE, SUITE J TALLAHASSEE, FL 32308 CERTIFICATE OF AUTHORIZATION 9292 JACQUES REGISTE, P.E. JOIST & POST CONNECTIONS NUTS AND WASHERS TO AT ALL BOLTS WITH THRU2 1(2)- INSTALL 42" MinBEAM TO POST CONNECTIONS (TYP.) WITH NUTS AND WASHERS AT ALL BOLTS THRU2 1(2)- BASE (ABA44) SIMPSON COLUMN 1’-0" TO PERIMETER BEAM (TYP.) AND 3" SCREWS AT 6" C/C 2 1 2"x6" DECKING3’-6"2’-0" (+/-)2’-6"CROSS BEAM 3 - 2x6 P.T. EXISTING AT 6" C/C 3" SCREWS 4X4 KNEE BRACE TO EXISTING 2X6 NEW 2X6 SCREWSGAP ABOVE DECKING 2"X4" RAIL WITH 2" 8"X8" POSTS 2"X8" P.T. JOIST 2X8 HANGERS TOPERIMETER BEAM (TYP.) 4" CONCRETE SLAB WITH WELDED WIRE 6" MINNOTICE: THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.(+/-)(+/-) (+/-) 2"X8" OR 2"X6" P.T. JOIST 2X10 8X8 COLUMN 2 - 2X10 BEAMS 2 - 2X10 BEAMS 2X8 JOIST Exist. BOLTS SEE DETAIL"A" ADD 1 3/4" BOLT N.T.S. N.T.S. DETAIL "A" (BEAM TO COLUMN CONNECTION) (EXISTING BEAM TO COLUMN CONNECTION) PROPOSED DECK ELEVATION WITH RAILINGS J.R. 01-20 K.G. 01-20 REF. DWG. NO. SHEET NO. SHEET TITLE: PROJECT NAME: DRAWN BY: CHECKED BY: DESIGNED BY: CHECKED BY: REVISIONS DATE BY DESCRIPTION DATE BY DESCRIPTION $USER$$DATE$$TIME$$FILE$ J.R. 01-20 J.R. 01-20 S-5 VIEW A-A N.T.S.(TO BE REPAIRED) EXISTING STAIR DETAIL N.T.S. PROPOSED STANTION DETAIL SECTION B-B RENOVATION PLANS STAIRS AND DECK DETAILS SECTION C-C 7/21/2020 JR COMPLIANCE LEVEL AND DECK DETAILS1 7/21/2020 JR 1 EXISTING FLOOR LAYOUT AND STAIRS DETAILS 1 EXISTING FLOOR LAYOUT AND STAIRS DETAILS 1 ADD DECK DETAILS 1 1 4006 Avenue P, Fort Pierce Florida HT2.5 JOIST INTERSECTIONS BLOCKING 2" X 8’ NUT AND WASHERS TYP. Ga. MACH. BOLTS WITH 2- 2 X 10 BEAM’S SECURED TO 16" O.C. 2" X 8" METAL DRIP 12 4 2’-0" RAFTERS @2’-0" O.C. ROOF SHINGLE ROOF 2X8 0R 2X6 BEAMS TYP THROUGH OUT SIMPSON STRAP H2.5 INSTALL TIE DOWN INSULATION EXISTING R-19 TO BE INSTALLED INSULATION EXISTING PROPOSED 3/8" CDX PLYWOOD 1 SCALE :N.T.S. PANEL EDGE NAILING 10D @ 4" O.C. DIRECTION OF FACE GRAIN SUPPORTED PANEL EDGE NAILING FIELD NAILING AT INTERMEDIATE SUPPORTS NOTES: P.E. LICENSE NUMBER 43397 EBBSTONE, INC. 3370 CAPITAL CIRCLE NE, SUITE J TALLAHASSEE, FL 32308 CERTIFICATE OF AUTHORIZATION 9292 JACQUES REGISTE, P.E. HURRICANE CLIPS EXISTING EXISTING TIE DOWNUNDER FLOOR SHEATHING DETAILS (BOTTOM) BRIGHT COMMON NAIL AS TEMPORARY SPACER. " USING 16D 8 1SPACE PLYWOOD BUTT JOINTS OF THE PANEL. EDGES AND ENDS, AND 6" O.C. IN THE FIELD RINGSHANK NAILS SPACED 4" O.C. AT PANEL FASTENERS SHALL BE GALVANIZED 10D WOOD STRUCTURAL PANEL DIAPHRAGMS. RECEIVE DECKING SHALL BE FRAMED AS A ALL HORIZONTAL AND INCLINED MEMBERS THAT NOTICE: THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.J.R. 01-20 K.G. 01-20 REF. DWG. NO. SHEET NO. SHEET TITLE: PROJECT NAME: CHECKED BY: DESIGNED BY: CHECKED BY: REVISIONS DATE BY DESCRIPTION DATE BY DESCRIPTION $USER$$DATE$$TIME$$FILE$ J.R. 01-20 J.R. 01-20 S-6 RENOVATION PLANS CONNECTION DETAILS FLOOR CONNECTION WHERE NECESSARY REINFORCEMENT AT ROOF/WALL AND 1 4006 Avenue P, Fort Pierce Florida P.E. LICENSE NUMBER 43397 REGISTE, SLIGER ENGINEERING, INC. 3370 CAPITAL CIRCLE NE, SUITE J TALLAHASSEE, FL 32308 CERTIFICATE OF AUTHORIZATION 9292 JACQUES REGISTE, P.E.NOTICE: THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.4’-0"11’-8"11’-6"6’-0"8’-0"7’-6"7’-4"7’-6"7’-1"10’-0"11’-6"3- 6"X6" PT columns(Typ) 8"X8" Columns BE REPLACED WINDOW TO BEDROOM BEDROOM BEDROOM LIVING AREA CONST. SHOWER TOILET INSTALL VANITY & TOILET INSTALL VANITY & SINK INSTALL CABINET & REPAIR DRYWALL J.R. 01-20 K.G. 01-20 REF. DWG. NO. SHEET NO. SHEET TITLE: PROJECT NAME: DRAWN BY: CHECKED BY: DESIGNED BY: CHECKED BY: REVISIONS DATE BY DESCRIPTION DATE BY DESCRIPTION $USER$$DATE$$TIME$$FILE$ J.R. 01-20 J.R. 01-20 S-7 INSIDE RENOVATION PLAN RENOVATION PLANS INTERIOR REPAIR PLANS 4006 Avenue P, Fort Pierce Florida