Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method RIX-MEo Project Name: LOWERY REMODEL Builder Name: JUN 0 4 Street: 4901 GROVERS RD. Permit Office: ST. LUCIE COUNTY 2020 City, State, Zip: FT. PIERCE, FL, Permit Number: Permitting Department Owner: ZANE & CHRISTY LOWERY Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1968.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame -Wood, Exterior R=13.0 1968.00 ft' b. N/A R= ft' 3. Number of units, if multiple family 1 c. NIA R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 10. Ceiling Types (1140.0 sqft.) Insulation Area S. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1140.00 ft 6. Conditioned floor area above grade (ft') 1624 b. N/A R= ft' c. NIA R= ft' Conditioned floor area below grade (ft-) 0 11. Ducts R ft' 7. Windows(196.8 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: CLOSET 6 205 a. U-Factor: Sgl, U=0.30 130.75 ft' SHGC: SHGC=0.21 b. U-Factor: Sgl, U=0.65 66.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 28.0 SEER:15.00 c. U-Factor: N/A ft' - SHGC: 13. Heating systems kBtufhr Efficiency d. U-Factor: NIA ft' a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.240 14. Hot water systems a. Electric Cap: SO.g 8. Floor Types (1318.0 sqft.) Insulation Area EF: .950 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1120.00 ft' b. Conservation features b. Floor Over Other Space R=0.0 198.00 ft' None c. NIA R= ft' 15. Credits None Glass/Floor Area: 0.121 Total Proposed Modified Loads: 53.35 PASS Total Baseline Loads: 55.38 1 hereby certify that the plans and specifications covered by Review of the plans and F•tJ4E STgT this calculation are in compliance with the Florida Energy specifications covered by this indicates �0� Code. calculation compliance with the Florida Energy Code.73 F rua,`z°•, +s:'='°. PREPAFZDJ Before construction is completed nU DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. CDD {yE TRJ OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R46®ntfibject requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). Copy L9oD3 ,6g7a 5/29/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: LOWERY REMODEL Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1624 Lot # Owner Name: ZANE 8 CHRISTY LOWERY Total Stories: 2 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4901 GROVERS RD. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design DailyTemp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1624 12992 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 M BATH 108 864 No 0 1 Yes Yes Yes 2 WIC 2 20 160 No 0 1 No Yes Yes 3 MASTER BEDROO 431 3448 No 2 1 1 Yes Yes Yes 4 LAUNDRY 55 440 No 0 1 Yes Yes Yes 5 KITCHEN 143 1144 Yes 0 1 Yes Yes Yes 6 FAMILY ROOM 363 2904 No 3 1 Yes Yes Yes 7 BEDROOM 3 202 1616 No 1 1 1 Yes Yes Yes 8 BATH 40 320 No 0 1 Yes Yes Yes 9 BEDROOM 2 140 1120 No 1 1 1 Yes Yes Yes 10 LANDING 60 480 No 0 1 Yes Yes Yes 11 CLOSET 42 336 No 0 1 Yes Yes Yes 12 WIC 20 160 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation M BATH 30 it 0 108 ft' ---- 0 1 0 2 Slab -On -Grade Edge Insulation WIC 2 1 ft 0 20 ft' ---- 0 1 0 3 Slab -On -Grade Edge Insulation MASTER BEDRO 44 ft 0 431 ft' ---- 0 1 0 4SIab-On-Grade Edge Insulation LAUNDRY lift 0 55 ft' ---- 0 1 0 5 Slab -On -Grade Edge Insulation KITCHEN 13 ft 0 143 ft' ---- 0 1 0 5/29/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 Fl1RM PAnS_9n17 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulation FAMILY ROOM 55 ft 0 363 R2 ____ 0 1 0 7 Floor Over Other Space BEDROOM 3 __-- __-- 198 ft2 0 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1201 ft2 Oft' Unfinishe N 0.5 No 0.7 No 20 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1140 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MBATH 0 Blown 108ft' 0.1 Wood 2 Under Attic (Unvented) WIC2 0 Blown 20 ft2 0.1 Wood 3 Under Attic (Unvented) MASTER BEDRO 0 Blown 431 ft2 0.1 Wood _ 4 Under Attic (Unvented) LAUNDRY 0 Blown 55 ft2 0.1 Wood _ 5 Under Attic (Unvented) FAMILY ROOM 0 Blown 22 ft2 0A Wood 6 Under Attic (Unvented) BEDROOM 3 0 Blown 202 ft2 0.1 Wood 7 Under Attic (Unvented) BATH 0 Blown 40 ft2 0.1 Wood 8 Under Attic (Unvented) BEDROOM 2 0 Blown 140 ft2 0.1 Wood 9 Under Attic (Unvented) LANDING 0 Blown 60 ft' 0.1 Wood 10 Under Attic (Unvented) CLOSET 0 Blown 42 ft2 0.1 Wood 11 Under Attic (Unvented) WIC 0 Blown 20 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Frame - Wood M BATH 13 9 0 8 0 72.0 ftz 0 0.25 0.5 0 _ 2 E Exterior Frame - Wood M BATH 13 12 0 8 0 96.0 ft2 0 0.25 0.5 0 _ 3 S Exterior Frame - Wood M BATH 13 9 0 8 0 72.0 ft2 0 0.25 0.5 0 _ 4 N Exterior Frame - Wood MASTER BE 13 19 0 8 0 152.0 ft2 0 0.25 0.5 0 _ 5 S Exterior Frame - Wood MASTER BE 13 2 0 8 0 16.0 W 0 0.25 0.5 0 _ 6 W Exterior Frame -Wood MASTER BE 13 23 0 8 0 184.0 ft2 0 0.25 0.5 0 _ 7 E Exterior Frame -Wood LAUNDRY 13 11 0 8 0 88.0 ft2 0 0.25 0.5 0 _ 8 E Exterior Frame - Wood KITCHEN 13 13 0 8 0 104.0 ft2 0 0.25 0.5 0 _ 9 E Exterior Frame - Wood FAMILY ROO 13 10 0 8 0 80.0 ft2 0 0.25 0.5 0 _ 10 S Exterior Frame - Wood FAMILY ROO 13 22 0 8 0 176.0 ft2 0 0.25 0.5 0 -it W Exterior Frame - Wood FAMILY ROO 13 23 0 8 0 184.0 ft' 0 0.25 0.5 0 _ 12 N Exterior Frame - Wood BEDROOM 3 13 7 0 8 0 56.0 ft' 0 0.25 0.5 0 13 S Exterior Frame -Wood BEDROOM 13 9 0 8 0 72.0R2 0 0.25 0.5 0 5129t2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Omt Tn Wall Type Space _ 14 W Exterior Frame -Wood BEDROOM 3 13 22 0 8 0 176.0 ft' 0 0.25 0.5 0 _ 15 N Exterior Frame - Wood BATH 13 5 0 8 0 40.0 ft' 0 0.25 0.5 0 _ 16 E Exterior Frame - Wood BATH 13 8 0 8 0 64.0 ft' 0 0.25 0.5 0 _ 17 E Exterior Frame - Wood BEDROOM 2 13 14 0 8 0 112.0 ft' 0 0.25 0.5 0 _ 18 S Exterior Frame - Wood BEDROOM 2 13 10 0 8 0 80.0 ft' 0 0.25 0.5 0 _ 19 N Exterior Frame -Wood LANDING 13 10 0 8 0 80.0 ft' 0 0.25 0.5 0 20 S Exterior Frame -Wood CLOSET 13 3 0 8 0 24.0 ft' 0 0.25 0.5 0 21 N Exterior Frame - Wood WIC 13 5 0 8 0 40.0 ft' 0 0.25 0.5 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated FAMILY ROO None .39 3 6 8 20 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Vinyl Low-E Single Yes 0.3 0.21 Y 12.8 ft' 2 ft 0 in 1 ft 4 in None None 2 N 4 Vinyl Low-E Single Yes 0.3 0.21 Y 30.0 ft' 2 It 0 in 1 ft 4 in None None _ 3 W 6 Vinyl Low-E Single Yes 0.3 0.21 Y 45.0 ft' 2 It 0 in 1 ft 4 in None None _ 4 E 8 Vinyl Low-E Single Yes 0.3 0.21 Y 13.0 ft' 2 It 0 in 1 ft 4 in None None 5 W 11 Vinyl Low-E Single Yes 0.3 0.21 Y 30.0 ft' 2 It 0 in 1 ft 4 in None None _ 6 N 12 Vinyl Low-E Single Yes 0.65 0.3 N 6.0 ft' 2 ft 0 in 1 ft 4 in None None 7 S 13 Vinyl Low-E Single Yes 0.65 0.3 N 9.0 ft' 2 It 0In 1 ft 4 in None None 8 W 14 Vinyl Low-E Single Yes 0.65 0.3 N 18.0 ft' 2 ft 0 in 1 ft 4 in None None _ 9 E 16 Vinyl Low-E Single Yes 0.65 0.3 N 9.0 ft' 2 ft 0 in 1 ft 4 in None None 10 E 17 Vinyl Low-E Single Yes 0.65 0.3 N 9.0 ft' 2 ft 0 in 1 ft 4 in None None 11 S 18 Vinyl Low-E Single Yes 0.65 0.3 N 9.0 ft' 2 It 0 in 1 ft 4 in None None 12 N 19 Vinyl Low-E Single Yes 0.65 0.3 N 6.0 ft' 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1082.7 59.44 111.78 .1162 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 5/29/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FnRnn PAn5-91117 INPIIT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 15 28 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None LAUNDRY 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 205 ft2 Attic 65 112 Default Leakage CLOSET (Default) c(Default) c 1 1 TEMPERATURES Programablet[ T'Jhermostat::[ Ceiling Fans: ]]N Heating Jan IX) Feb H Mar jXj Jun [ ] Jul [ ] Aug [X� ` ] Sep Nov r[X,j Oct Nov Dec H Dec Venting [ ]Jan [O] Feb l J X Mar Apar r May Jun ! 1 Jul EX] )Aug l ]Sep [X] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 M BATH Default(8 lbs/sq.ft. ft2 ft 0.3 WIC2 Default(8 lbstsq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.R. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 FAMILY ROOM Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 LANDING Default(8 lbs/sq.ft. ft2 ft 0.3 CLOSET Default(8 lbs/s.ft. ft2 ft 0.3 WIC 5/29/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: LOWERY REMODEL Builder Name: Street: 4901 GROVERS RD. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y V Owner: ZANE 8 CHRISTY LOWERY Jurisdiction: w x Design Location: FL, Fort Pierce o COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable Insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The Insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact wfth the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind olping and wring. Showeritub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. Insulated. Electricalfphone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be Installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover rilates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-4UU. 5/29/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location CLOSET 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.0 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1624 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.417 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.240 14. Heating system: Capacity 27.0 c) Area 7c. 196.8 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: 4901 GROVERS RD. City/FL Zip: FT. PIERCE. FL 5/29/2020 9:28:16 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1