HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
RIX-MEo
Project Name: LOWERY REMODEL
Builder Name:
JUN 0 4
Street: 4901 GROVERS RD.
Permit Office: ST. LUCIE COUNTY
2020
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Permitting Department
Owner: ZANE & CHRISTY LOWERY
Jurisdiction:
St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (1968.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Frame -Wood, Exterior
R=13.0 1968.00 ft'
b. N/A
R= ft'
3. Number of units, if multiple family
1
c. NIA
R= ft'
4. Number of Bedrooms
3
d. N/A
R= ft'
10. Ceiling Types (1140.0 sqft.)
Insulation Area
S. Is this a worst case?
No
a. Roof Deck (Unvented)
R=20.0 1140.00 ft
6. Conditioned floor area above grade (ft')
1624
b. N/A
R= ft'
c. NIA
R= ft'
Conditioned floor area below grade (ft-)
0
11. Ducts
R ft'
7. Windows(196.8 sgft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: CLOSET
6 205
a. U-Factor: Sgl, U=0.30
130.75 ft'
SHGC: SHGC=0.21
b. U-Factor: Sgl, U=0.65
66.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
28.0 SEER:15.00
c. U-Factor: N/A
ft'
-
SHGC:
13. Heating systems
kBtufhr Efficiency
d. U-Factor: NIA
ft'
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.240
14. Hot water systems
a. Electric
Cap: SO.g
8. Floor Types (1318.0 sqft.)
Insulation Area
EF: .950
0.950
a. Slab -On -Grade Edge Insulation
R=0.0 1120.00 ft'
b. Conservation features
b. Floor Over Other Space
R=0.0 198.00 ft'
None
c. NIA
R= ft'
15. Credits
None
Glass/Floor Area: 0.121
Total Proposed Modified Loads: 53.35
PASS
Total Baseline
Loads: 55.38
1 hereby certify that the plans and specifications covered by
Review of the plans and
F•tJ4E STgT
this calculation are in compliance with
the Florida Energy
specifications covered by this
indicates
�0�
Code.
calculation compliance
with the Florida Energy Code.73
F rua,`z°•, +s:'='°.
PREPAFZDJ
Before construction is completed
nU
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
CDD {yE TRJ
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R46®ntfibject requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
Copy
L9oD3 ,6g7a
5/29/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: LOWERY REMODEL
Bedrooms:
3
Address Type:
Street Address
Building Type: User
Conditioned Area:
1624
Lot #
Owner Name: ZANE 8 CHRISTY LOWERY
Total Stories:
2
Block/Subdivision:
# of Units: 1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
4901 GROVERS
RD.
Permit Office: ST. LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design DailyTemp
Design Location TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1624
12992
SPACES
Number Name Area
Volume Kitchen
Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 M BATH 108
864 No
0
1
Yes
Yes
Yes
2 WIC 2 20
160 No
0
1
No
Yes
Yes
3 MASTER BEDROO 431
3448 No
2
1
1
Yes
Yes
Yes
4 LAUNDRY 55
440 No
0
1
Yes
Yes
Yes
5 KITCHEN 143
1144 Yes
0
1
Yes
Yes
Yes
6 FAMILY ROOM 363
2904 No
3
1
Yes
Yes
Yes
7 BEDROOM 3 202
1616 No
1
1
1
Yes
Yes
Yes
8 BATH 40
320 No
0
1
Yes
Yes
Yes
9 BEDROOM 2 140
1120 No
1
1
1
Yes
Yes
Yes
10 LANDING 60
480 No
0
1
Yes
Yes
Yes
11 CLOSET 42
336 No
0
1
Yes
Yes
Yes
12 WIC 20
160 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter
Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation M BATH 30 it
0
108 ft'
----
0 1
0
2 Slab -On -Grade Edge Insulation WIC
2 1 ft
0
20 ft'
----
0 1
0
3 Slab -On -Grade Edge Insulation MASTER BEDRO 44 ft
0
431 ft'
----
0 1
0
4SIab-On-Grade Edge Insulation LAUNDRY lift
0
55 ft'
----
0 1
0
5 Slab -On -Grade Edge Insulation KITCHEN 13 ft
0
143 ft'
----
0 1
0
5/29/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
Fl1RM PAnS_9n17 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulation
FAMILY ROOM 55 ft
0
363 R2
____
0
1
0
7 Floor Over Other Space
BEDROOM 3 __--
__--
198
ft2
0
0
1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1201 ft2
Oft' Unfinishe
N
0.5
No 0.7
No 20
18.4
ATTIC
/
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Unvented
0
1140 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
MBATH
0
Blown
108ft'
0.1
Wood
2
Under Attic (Unvented)
WIC2
0
Blown
20 ft2
0.1
Wood
3
Under Attic (Unvented)
MASTER BEDRO 0
Blown
431 ft2
0.1
Wood
_
4
Under Attic (Unvented)
LAUNDRY
0
Blown
55 ft2
0.1
Wood
_
5
Under Attic (Unvented)
FAMILY ROOM
0
Blown
22 ft2
0A
Wood
6
Under Attic (Unvented)
BEDROOM 3
0
Blown
202 ft2
0.1
Wood
7
Under Attic (Unvented)
BATH
0
Blown
40 ft2
0.1
Wood
8
Under Attic (Unvented)
BEDROOM 2
0
Blown
140 ft2
0.1
Wood
9
Under Attic (Unvented)
LANDING
0
Blown
60 ft'
0.1
Wood
10
Under Attic (Unvented)
CLOSET
0
Blown
42 ft2
0.1
Wood
11
Under Attic (Unvented)
WIC
0
Blown
20 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
Space
_ 1
N
Exterior Frame - Wood
M BATH
13 9
0 8
0
72.0 ftz
0
0.25
0.5
0
_ 2
E
Exterior Frame - Wood
M BATH
13 12
0 8
0
96.0 ft2
0
0.25
0.5
0
_ 3
S
Exterior Frame - Wood
M BATH
13 9
0 8
0
72.0 ft2
0
0.25
0.5
0
_ 4
N
Exterior Frame - Wood
MASTER BE
13 19
0 8
0
152.0 ft2
0
0.25
0.5
0
_ 5
S
Exterior Frame - Wood
MASTER BE
13 2
0 8
0
16.0 W
0
0.25
0.5
0
_ 6
W
Exterior Frame -Wood
MASTER BE
13 23
0 8
0
184.0 ft2
0
0.25
0.5
0
_ 7
E
Exterior Frame -Wood
LAUNDRY
13 11
0 8
0
88.0 ft2
0
0.25
0.5
0
_ 8
E
Exterior Frame - Wood
KITCHEN
13 13
0 8
0
104.0 ft2
0
0.25
0.5
0
_ 9
E
Exterior Frame - Wood
FAMILY ROO
13 10
0 8
0
80.0 ft2
0
0.25
0.5
0
_ 10
S
Exterior Frame - Wood
FAMILY ROO
13 22
0 8
0
176.0 ft2
0
0.25
0.5
0
-it
W
Exterior Frame - Wood
FAMILY ROO
13 23
0 8
0
184.0 ft'
0
0.25
0.5
0
_ 12
N
Exterior Frame - Wood
BEDROOM 3
13 7
0 8
0
56.0 ft'
0
0.25
0.5
0
13
S
Exterior Frame -Wood
BEDROOM
13 9
0 8
0
72.0R2
0
0.25
0.5
0
5129t2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing Solar
Below
#
Omt
Tn
Wall Type
Space
_ 14
W
Exterior
Frame -Wood
BEDROOM 3
13
22
0 8
0
176.0 ft'
0
0.25
0.5
0
_ 15
N
Exterior
Frame - Wood
BATH
13
5
0 8
0
40.0 ft'
0
0.25
0.5
0
_ 16
E
Exterior
Frame - Wood
BATH
13
8
0 8
0
64.0 ft'
0
0.25
0.5
0
_ 17
E
Exterior
Frame - Wood
BEDROOM 2
13
14
0 8
0
112.0 ft'
0
0.25
0.5
0
_ 18
S
Exterior
Frame - Wood
BEDROOM 2
13
10
0 8
0
80.0 ft'
0
0.25
0.5
0
_ 19
N
Exterior
Frame -Wood
LANDING
13
10
0 8
0
80.0 ft'
0
0.25
0.5
0
20
S
Exterior
Frame -Wood
CLOSET
13
3
0 8
0
24.0 ft'
0
0.25
0.5
0
21
N
Exterior
Frame - Wood
WIC
13
5
0 8
0
40.0 ft'
0
0.25
0.5
0
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated
FAMILY ROO
None
.39
3
6 8
20 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame Panes
NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E 2
Vinyl Low-E Single
Yes
0.3
0.21
Y
12.8 ft'
2 ft 0 in
1 ft 4 in
None
None
2
N 4
Vinyl Low-E Single
Yes
0.3
0.21
Y
30.0 ft'
2 It 0 in
1 ft 4 in
None
None
_
3
W 6
Vinyl Low-E Single
Yes
0.3
0.21
Y
45.0 ft'
2 It 0 in
1 ft 4 in
None
None
_
4
E 8
Vinyl Low-E Single
Yes
0.3
0.21
Y
13.0 ft'
2 It 0 in
1 ft 4 in
None
None
5
W 11
Vinyl Low-E Single
Yes
0.3
0.21
Y
30.0 ft'
2 It 0 in
1 ft 4 in
None
None
_
6
N 12
Vinyl Low-E Single
Yes
0.65
0.3
N
6.0 ft'
2 ft 0 in
1 ft 4 in
None
None
7
S 13
Vinyl Low-E Single
Yes
0.65
0.3
N
9.0 ft'
2 It 0In
1 ft 4 in
None
None
8
W 14
Vinyl Low-E Single
Yes
0.65
0.3
N
18.0 ft'
2 ft 0 in
1 ft 4 in
None
None
_
9
E 16
Vinyl Low-E Single
Yes
0.65
0.3
N
9.0 ft'
2 ft 0 in
1 ft 4 in
None
None
10
E 17
Vinyl Low-E Single
Yes
0.65
0.3
N
9.0 ft'
2 ft 0 in
1 ft 4 in
None
None
11
S 18
Vinyl Low-E Single
Yes
0.65
0.3
N
9.0 ft'
2 It 0 in
1 ft 4 in
None
None
12
N 19
Vinyl Low-E Single
Yes
0.65
0.3
N
6.0 ft'
2 ft 0 in
1 ft 4 in
None
None
INFILTRATION
#
Scope
Method
SLA CFM 50
ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000254 1082.7
59.44
111.78
.1162
5
HEATING SYSTEM
#
System Type
Subtype
Speed
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA
27 kBtu/hr
1
sys#1
5/29/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FnRnn PAn5-91117 INPIIT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 15
28 kBtu/hr
cfm 0.7 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
LAUNDRY
0.95 50 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
— Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 205 ft2
Attic
65 112 Default Leakage
CLOSET
(Default) c(Default) c
1 1
TEMPERATURES
Programablet[ T'Jhermostat::[
Ceiling Fans:
]]N
Heating Jan IX) Feb
H Mar
jXj
Jun [ ] Jul
[ ]
Aug
[X�
` ] Sep
Nov
r[X,j
Oct Nov
Dec
H Dec
Venting [ ]Jan [O] Feb
l J
X Mar
Apar r
May Jun ! 1 Jul
EX]
)Aug
l ]Sep
[X]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9 10 11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80 80 80
80
PM
80
80 80
80 78 78
78
78
78 78 78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
80 80 80
80
PM
80
80 80
80 78 78
78
78
78 78 78
78
Heating (WD) AM
65
65 65
65 65 65
65
68
68 68 68
68
PM
68
68 68
68 68 68
68
68
68 68 68
68
Heating (WEH) AM
65
65 65
65 65 65
65
68
68 68 68
68
PM
68
68 68
68 68 68
68
68
68 68 68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
M BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC2
Default(8 lbstsq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/sq.R.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
FAMILY ROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
LANDING
Default(8 lbs/sq.ft.
ft2
ft
0.3
CLOSET
Default(8 lbs/s.ft.
ft2
ft
0.3
WIC
5/29/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: LOWERY REMODEL Builder Name:
Street: 4901 GROVERS RD. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
V
Owner: ZANE 8 CHRISTY LOWERY Jurisdiction:
w
x
Design Location: FL, Fort Pierce
o
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable Insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The Insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be Installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact wfth the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind olping and wring.
Showeritub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
Insulated.
Electricalfphone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be Installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover rilates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-4UU.
5/29/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location CLOSET
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
28.0
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1624
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.417
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.240
14. Heating system: Capacity
27.0
c) Area
7c. 196.8
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor.(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1. 13.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
No
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code,
Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder
Address of New Home: 4901 GROVERS RD. City/FL Zip: FT. PIERCE. FL
5/29/2020 9:28:16 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1