Loading...
HomeMy WebLinkAboutRevisionOFFICE USE ONLY: DATE FILED: � REVISION FEE: r^l S' 0 0 LOCATION/SITE ADDRESS: 8735 S OCEAN DR SLIP # 10, PERMIT 1909-0352 PERMIT # RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT REVISIONS: CHANGE BOATLIFT MANUFACTURER OEM (ORIGINAL EQUIPMENT MANUFACTURER DRAWINGS TO A MODEL MANUFACTURED BY HI TIDE BOATLIFTS CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: MCMAR 02985 ST. LUCIE CO CERT. #: BUSINESS NAME: HARBOR BAY MARINE INDUSTRIES QUALIFIERS NAME: SCOTT SAFRANSKY ADDRESS: 1525 SE CAMBRIDGE CITY: PORT ST LUCIE STATE: FL ZIP: 34952 PHONE (DAYTIME): 772-485-2298 FAN: soott@harborbaymarine.com NAME: _ ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: ROGER BABER ADDRESS: 3770 NW ROYAL OAK DR CITY: JENSEN BEACH STATE: FL ZIP: 34957 PHONE (DAYTIME): 772-214-4800 FAX: rbaber@mcrengineers.com Rr.vISION qL� C "I ILI It Uri PLANNING & DEVELOPMENT SERVICES BUIULDING & ZONING DIVISION 2300 VIRGINIA AVE FORT PIERCE, FL 34982 (772) 462-1553 FAX 462-1578 CHANGE OF CONTRACTOR. SUBCONTRACTOR OR CANCELLATION OF PERMT PLEASE SELECT ONE OF THE FOLLOWING: x CHANGE OF CONTRACTOR — Change of Contractor is to be signed and notarized by the property owner, and the new contractor of record for the current permit. A new permit application must also be completed with new contractor information and signature. A new Notice of Commencement must be filed in the new contractor's name for job values greater than $2,500 ($7,500 if A/C Change -out). A recorded copy must be submitted prior to commencing any work. There is a $50.00 fee for the Change of Contractor. CHANGE OF SUBCONTRACTOR — Subcontractor changes are to be completed by the general contractor. The new subcontractor must fill out a Subcontractor Agreement Form. There is a $50.00 fee for the Change of Sub - Contractor. 8735 : CANCELLATION OF PERMIT — The cancellation of a permit is acceptable only if no work has been done. Cancellation of permit is to be signed and notarized by both the owner and qualifier of record. There is no fee for cancellation of the permit. Date: Permit Number: 1909-0352 Site Address: 8735 S OCEAN DRIVE, JENSEN BEACH, FL 34957 MARINA, SLIP 10 JOHN RUHS State License CGC 1511185 SLC License Original GC, subcontractor or owner/builder HARBOR BAY MARINE INDUSTRIES State License MCMAR 02986 SLC License New GC, subcontractor Reason for Cancellation NOT CANCELLED - CHANGE OF CONTRACTOR The undersigned does hereby agree to indemnify and hold harmless St Lucie County, its officers, agents and employees from all cost"es or damages arising from any and all claims of action for any reason, which may a �s a result o 's change of - con ct r/ n ctor or cancellation o permit A permit cannot be cancelled if w as en rmed. SIGN[k.TURE OF t or owner SIGNAYdnG E O C/T�OR (or Ow w GC, as applicable) RRT NAMF. bOd I/)_Gf/1 PRINT itN �QY1CY'\ State of Florida, County of St Lucie County The following instrument was acknowledged before me it day of . 20. by is personally known to me or who has produced as ID. Signature of Notary Date Revised 04/15/16 State of Florida, County of St Lucie County e following' nume�t-�was acknowledged before me this Ca day of f�• 20d0 by S1DY SZO Ct who is personally known to rr�pr who itas prodp �a$ 1 ` IIVI (NL, I al�oao Signat eofNota Date _ �p1PR &Virginia C. Jayne NOTARY PUBLIC � S STATE OF FLORIDA Comm# GG367473 '43Ec ie Expires 9/2312023 State of Florida Acknowledgement Notary Certificate STATE OF FLORIDA COUNTY OF l ,/�A O' I(�n 0410 before me, a notary public, personally appeared by physical presence, who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the attached [name of document] instrument and acknowledged to me that that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s) or entity upon behalf of which the person(s) acted executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State listed above that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Personally known OR ^ Produced identification Ir Type of identification produced: Q�tl L'tAAk48M (Sig re of not ry u61icJ �( ' `eC ` My commission expires: oT cN (�3 �Pyq„� JENNIFER�R.WHITESELL i °� Notary Public. State of Florida CommissionN GG 319968 My Comm. expires Apr. 4, 2023 Official Seal 05-74-0433NSB 02-2020 ENGINEERING REVIEW.• BOAT LIFT TOP CARRIER BEAMS AND MOUNTING BRACKETS COMPLY WITH WIND LOAD REQUIREMENTS OF THE BIN EDITION (2017) FLORIDA BUILDING CODE, PER ASCE 7, AND PER DESIGN LOAD REQUIREMENTS OF THE 2015 EDITION ALUMINUM ASSOCIATIONSS ALUMINUM DESIGN MANUAL. BEAMS AND MOUNTING BRACKETS INSTALLED PER HI —TIDE INSTRUCTIONS WILL EXCEED ULTIMATE DESIGN WIND SPEED OF 180 MPH (EXPOSURE CATEGORY C OR D) BOATS ARE TO BE REMOVED FROM BOAT LIFTS PRIOR TO A MAJOR WIND EVENT. PILINGS: PILING PENETRATION TO BE 10' INTO THE SAND BOTTOM OR 5' INTO ROCK STRATA, SUB —SURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES TO COMPLY WITH FBC 2017. ALL PILINGS TO BE 10" MINIMUM DIAMETER 2.5 C.C.A PRESSURE TREATED WOOD, PRE —STRESSED CONCRETE OR COMPARABLE EQUIVALENT. ELECTRICAL RFN W.• 3/4 HP ELECTRIC MOTOR — AMPS ® 115V EACH 5.4 AMPS ® 230V EACH QUANTITY.• 4 TOTAL WATTS: 4968 X2 ELECTRICAL REVIEW. 1-1/2 HP ELECTRIC MOTOR — AMPS ® 115V EACH 9.6 AMPS ® 230V EACH QUANTITY.* 4 TOTAL WATTS 8632 N07E TO EXAMINER: THIS CERTIFIED ENGINEERED DRAWING HAS BEEN PREPARED SPECIFICALLY FOR USE ONLY BY: jQ1Dof -035Z — °0ppp0o°ooa000nncoocooe ®p ®p y-y s° (G M B 4 000Oo REVIEWED FOR e° O � G E N S a °e CODE COMPLIANCE e O v F m 41 NO.43M P ST, LUCIE COUNTY ►tit EOCCRFEB 17 Z 0 "' `e -p STATE OF d4 �� j_.'it •• \:: u u 00000 —, A,4 O R 1 0000s B epON Ao ROGER SABER P.E. NO. 43855 MCR PROFESSIONAL ENGINEERING C.A. NO. 26967 1014 NE PINELAKE DR. STUART,, FL J4994 PILING MOUNTING TABS MIN/MUM (2) 3/8- DIA. SS LAG BOLTS FOR WOOD PILING OR SS CONCRETE ANCHORS FOR CONCRETE PILINGS PER PILING REQUIRED. MINIMUM (2B- ' D A. SS CARRIAGE BOLT3FOR 1�..7� yyqq �.1 ATTACHING MOUNTING TAB TO. F.1` / tN [l�j t..t1 LIFT REQUIRED PER PILING. �y1]] SI ! �•' MOUNTING TAB CONSTRUCTED FROM 1/4" X 2- ALUMINUM „j,,,i� t,y;.l�� (,{ •.�� 6 0 6 1 — T 6 FLAT BAR. 24,000 LB. 8 PILE GEAR DRIVE & BOATUFTS AND MARINE PRODUCTS GEAR DRIVE X2 BOAT LIFT (2017 FBC) UU�O1 4050 SELV77Z ROAD FORT PIERCE, FL 34981 RTDE SCALE.N75 DATE.1/2/18 REV 1 1-800-544-0735 www.hi-tlde.com