HomeMy WebLinkAboutSet-Up Manual; THERMEAU Pool Heat Pump•� t_i � _ i' ► iF�� :�I�Ii7�:1�\r111JiIG
�C�iVED
rmilting
naa
PRIMED IN CANADA
t,
3
5
tions 6
Installation Instructions
Location
Water piping
Multiple Heat Pump Connections
Electrical
Bonding
Bonding and plumbing step-by-step instructions
Electrical Connections
Electrical Diagrams
Service -Analyzer Control
Electronic Temp. Controls
Initial Startup
Meaning of Display Codes
Troubleshooting
Requesting Assistance or Service
Maintenance
-- - ----------.._.... -
Winterizing
Pool Heat Pump Warranty
2 THER' OWNER'S MANUAL
HLy]E!A.t441 V)VlEk.4L MDLN TPIMP
7
--7 0
11
- -12
12
12.
13
14
15
15
18
19
20
22
22
22
23
an THERMEAU ' pool heat pump.
The THERMEAU pool heat pump is a self-contained unit designed specifically
for pool heating. Each component has been selected with care to achieve a
high -quality product in an effort to exceed all industry standards.
All THERMEAU pool heat pumps have a Scroll compressor, an electronic board
with service analyzer, a titanium heat exchanger tube warranted for 10 years
against corrosion. All components are of superior quality, which presents you
with an effective, state-of-the-art technology heat pump.
In general, compared to other types of pool heaters, such as gas or oil-
fired, the THERMEAU pool heat pump has a lower heating capacity on a
BTU/hr basis. Therefore, it needs to operate for a longer time to accomplish
the desired results. Occasionally, it may be necessary to run the heat pump for
up to 24 hours per day. However, this should not be of concern to the owner
because the heater is designed to operate continuously. What's more, despite
continuous operation, it will still heat the pool far more economically than other
types of heaters.
OWNER'S MANUAL THEE EA ' 3
l • `
%a a
at
P �
Please f'ead carefully
t WhensveryoU call fo regUesfsernce for"your heater, myou must know your,
Cz�mplete rliodel`ar d ser al fiumbefs. You can find° this information on the
nameplate located on the right side:of your heater.
_ Please also record the purchase date of your device and your dealer's name,
address, and telephone number.
Model Number
Serial Number
Purchase Date
Dealer Name
Dealer Address
Dealer Phone
Keep this book and the sales slip together in a safe place for future reference.
4 THERM L`-€U* OWNER'S MANUAL
v.L^�.Mua•'�CCv1fx;W PWLxGfpVNP
O
. a f 4 r
General.56f& instructions
We care for our customers
We have provided important safety messages in this manual and on your
heater. Always read and obey all safety messages.
....... � ...-7 - ...
IMPORTANT
TheIMPORTANT sign calls attention to a note that provides, impartant`
:-information odriformation essential to the completion of a task "
-CAUTION `•
Q} Proper pool chemistryis'vital'to the life of your heater., Pay particular.
often by an iodependent.pdol store.
OWNER'S MANUAL THERi V MU 5
P_T..fV R`! 18C C4:ee!£FCI4PLOL MGi PYNP
quatIt : standards that�wst be tntCty bserved -
" De rip "Noiinat Range . `T' Verification
- 721o,T:8
Once/Week
` i . 't
rv=
GhEonne concentration
• 1.0 to 3.O:ppm ' _
Once/2-3 days
_
' Total alkalinity
80 to 100 ppm
Once/2-3 weeks
'
Total dissolved solids (TDS)
Below 1600 ppm (fresh water)
Once/month
Below 3000 ppm (salt water)
Onceftonth
Calcium hardness
200 to 300 ppm
Once/month
A robust and reliable product line
Residential
Volts 230 230 230
230
230
230
Hertz 60 60 +. 60 60
60 60
Phase
Cpmpressoramps, 1105A _ _ 124A.- 143A 212A
t24.3 AM 273A 1
Fan motor max. 2,4A 2.4A 2,4A
load amps
2,4A
2.4A
2.4A
:Fan motor HP 1/3 1/3 1/3"• ti3 1/3
.anm _ _w _..
ry
1/3
_..w
Fan motor speed 825RPM 825RPM 825RPM
825RPM
825RPM
825RPM
Optimal water Cow
rate (GPM)
30
30 35
40
55
60
:Max. waterflow
�.:
rate GP
100
"100 too
160
100
100's
Max. water
104F
104F 104F
104F
104F
104F
6 iNE ' OWNER'S MANUAL
XESUENM1N ��up✓nuEu:,yt 0.ULxGi PYMP
Commercial
�CampTassar(HP) -
2x5' `
'
..,. ..... .. .,.
..F
.,.aw.s�__._
_10. _
n..,..,. t ,..>s.,
Compressor type
scroll
scroll
scrollM
( Heat a changer ..
-Titanium/PVCeTitanium/PVC
Tftanlum/PVC "_VY)
Heating range
Up to
Up to
Up to
(°F/°C)
104°F/40°0
104°F/40°C
104°F/40°C
VoltageNzlPh
20824060/1
.- 20824060/3
67560060/3_g
Required breaker
60
60
30
Mirnmum c,roud tunpaekty
..
47-.
44
168 "..
_
M F2- _
r.
Plumbing connectionsm"
2-
2
Water Row (GPtvii
,. .,....,. �,..,....
.60 to 125
;,.. �.,a.rye
60 to 125 "
.., ..........
':6010125
............. .zM.n„...
1-1:48
1-1:48
1-1:48
Dimensions in inches
W: 33
W: 33
W: 33
D:39
D:39
D:39
Hot GasDefrost "
•s.........�.....n ..
Yes :..
....0 —.wx,. .a..ne.,.,
Yes
.... tA....�.u�:,_.r.mm.n.
.•.w.J. w.n... •..,.w...v..�x...
Weight gb)
445
375
375
Installation Instructions
Location
The placement of the pool heater is very important in keeping installation
costs to a minimum while providing for maximum efficiency of operation, as
well as allowing adequate access for service and maintenance.
The THERMEAU pool heat pump is designed for outdoor installation and
should not be installed in a fully enclosed area, such as a shed, garage, etc.,
unless ventilation is provided to ensure adequate air exchange for proper
operation. Recirculation of cold discharged air back into the evaporator coil
will greatly reduce unit heating capacity and efficiency.
The unit should be located as close as practical to the existing pool pump and
filter to minimize water piping.
Mount the unit on a sturdy base, preferably a concrete slab or a set of blocks.
The size of the base should not be less than 40" x 40" (100 cm x 100 cm).
OWNER'S MANUAL :[! ER 7
W1.
AUr ispullecfthrough the evaporator coil and discharged through the top grille.
Atminimurri clearance of 48 inches should be allowed above the unit for unre-
'stricted air discharge: The unit must not be installed under a porch. Any side
of the unit should be located at least 12 inches from a wall or from any other
obstruction for unrestricted air intake and service access. The back side of the
unit or one of the two sides (left or right) could be installed at 6 inches from
any obstruction as long as the two other sides are at a minimum of 12 inches
distance of any obstruction.
Twvkw
8 THERMY D* OWNER'S MANUAL
k�SGE.^I.ul.> N'YFv:V.l lgpl NFAi PYNa
In compliance with the Florida Building Code 301 13, pool;
must be anchored to a structure for hurricane resists
Anchor are required on each installation.
Installation:
1. Place the THERMEAU°Heat Pump
at its permanent location
on the equipment pad.
Installer to proilde anchors bolts
and the suitable concrete anchor
to attach the angle steel bracket
to the equipment pad.
2. Place the angle steel bracket at the
bottom of the THERMEAU°Neat Pump
as indicated (Hg. 11
3. Bolt on the angle steel bracket
to the base as indicated (Ng. 2).
4. Mark the position of the hole
in each angle steel bracket
on the backing material.
S. Drill a hole at each mark
into the equipment pad.
6. Insert a bolt anchor in each hole
completely.
7. Line up anchor the angle steel bracket
holes and bolt anchors (fig. 2).
B. Put an anchor bolt in each angle
steel bracket.
Figure 1. Anchor Positions
Attach anchor brackets to base of heat pump
where indicated by the arrows.
Figure 2 Angle Steel Bracket
HEAT PUMP
PLASTIC
BASE
OWNER'S MANUAL THERM.AAU' 9
PuaP
-' The ppthg sequence is as follows: pool pump > filter > heater> pool. Auto-
inated'chlorine distribution systems, if used, must be placed downstream of
the heater to minimize harm to the pool equipment. Use rigid PVC piping if
possible (SGH40 or SCH80). All joints should be glued with PVC glue. If rigid
PVC is not available, you can use soft or flexible piping with stainless steel
clamps. When the piping installation is complete, operate the pool pump and
check the system for leaks. Then, check the filter pressure gauge to verify
that there isn't any indication of excessive pump head pressure.
You can also make the connections using high-pressure flexible hose, but
make sure the hose can withstand high pressure. The installation of a bypass
is not necessary unless the water flow exceeds 125 GPM,
Fig. 2
10 THE ,%' OWNER'S MANUAL
weu�ri.0 �•� cn nxcx:i: rao: xu. roar
All plumbing on multiple heat pump installations must be done in parallel`A6
equal flow of water to each heat pump is important for optimum operation.
NOTE: It may be necessary to adjust water pressure switch if a unit is installed
below the water level.
Each heat pump allows a maximum flow rate of.125 gpm (473 Umin) and
requires a minimum of 60 gpm (227 Umin).
Fig. 3
Fig. 4
OWNER'S MANUAL THE 11
w=�ioun.. rx� r. oet_>cux rwi xur roar
x ..n' ry
vt.'w k.rt'}""'`? a
r 3 v�+er X s-`s
k -_i`t
.�y�
kr"x
(
w4Y }3
Efectr;ca"t
Electrical Connections. -
i„
CA111'10
}
WARN NG
�L
��
vTtje wiring of your THERMEAU .pool heat. pump should be performed by a
The installation of the THERMEAU pool heater should be performed by a cer-
qualified electrician in accordance with local requirements.
tified electrician. To connect the electricity, you must unscrew the four screws
of the front panel, then slide the electric cable in the hole located on the left
e „
®W/RN(N _.
u „ , W,,` '�„;, .,
or the right side of the base, and then insert it in the control box. The electrical
diagram is located on the lid of the control box as well as below.
The unit must always be deactivated before opening the access panel.
Bonding
Because all metals have different electrical potentials, all metal and electrical
components of the pool system must be bonded together. This includes the
metal framework of the pool, the light, the pump, the filter (if made out of metal),
the heater, any automatic chlorine generator, and any other metal or electrical
equipment. On some older pools, this substructure bond wire may not exist.
In these cases, a 6 to 8 foot solid copper rod must be driven into the ground
near the equipment. All electric and metal components must then be bonded
to each other, and then to the copper rod.
Bonding and Plumbing
step-by-step instructions
1. A 1/3 lb check valve must be installed between the heater
and any automatic chlorine distribution system (if used).
2. Any kind of automatic chlorine distribution system must be
installed after or downstream of the heat pump.
3. The filter must be placed before or upstream
from the heat pump.
12 THERM E ' OWNER'S MANUAL
X[a4PY!..i aDtL..,-!Y".L'41 PoOLNFAi PVNP
Ground L3 L2 L1
Ground Lt L2
3 Phase loss and reversal protection
Operating mode:
The THERMEAU unit is equipped with SCROLL
compressor which cannot run in both rotations.
When the heating light on the main board will come
on, If all three phase are relatively equal and in pro-
per sequence, the (ON) green light on the phase
protector will be energize and the compressor will
start normally. If the phase are in wrong sequence,
that'll be the (FAULT) red light that come ON and the
compressor won't start. If this occurred, you have to
switch the L1 wire with L2 wire.
ON
OWNER'SMANUAL THERMMAU- 13
N9,'.iO�h�. flip CGe`�F:::'NLpWLXGiPYw,p
Wiring Diagram
Jef V P
The control
Temperature
and parameter
display
Access
to parameters
is factory„set to display the temperature in Fahrenhi
Fig. 5
Electronic Temp. Controls
All units
Heating mode
Compressor running
Heating mode
To raise the desired
temperature or to
change parameters
To lower the desired
temperature or to
change parameters
Description
The control located on the front of your heat pump has a large three -character
display for the water temperature, set points, and diagnostics (see figure 5
for front panel appearance). The three button keypad includes SET, DOWN
arrow, and UP arrow buttons. LED indicators next to the display show if the
heat pump is in the pool mode or in the spa mode and if the unit is running.
Buttons:
Press the SET button to change between modes and use the UP and DOWN
arrows to change the selected mode's settings.
14 AV OWNER'S MANUAL OWNER'S MANUAL 15
t)FF It7 A you+ Bch it QN prt)FF
DL ll ws yo to change # 1e pool tuatet temperature set point.
t �.�`Allbws yourto'changeahe spa water temperature set point.
Changes between pool and spa settings:LED's on front panel will
indicate current mode selected.
Water Temperature Set Point
Temperature set point range is 51'F to 95'F for POL mode. For SPA mode,
set point range is 51'F to 104'F. Pushing the UP arrow or DOWN arrow but-
tons will prompt the control to display the current set point. Continuing to
press the UP or DOWN arrows will allow the set point values to scroll until the
desired set point is reached. Once the new set point has been reached, stop
pressing the UP or DOWN arrows. Once the unit toggles back to the current
water temperature display, the set point is entered. The controls have a fea-
ture called "Set Point Memory Retention". If the power is removed from the
unit, it retains the last set point displayed.
Heat/Cool Operation (Prestige Series Only)
The heat/cool model is designed to both heat and cool the pool. To select
heat or cool mode, push the set key until H/C is displayed. Press the DOWN
arrow key to select heating (HEA), or the UP arrow key to select cooling (COL).
Set the desired setpoint temperature as described on page 16.
When the heating mode is activated and the unit is running, the letters HEA
will be flashing in alternately with the pool temperature.
When the cool mode is activated and the unit is running, the letters COL will
be flashing in alternately with the pool temperature.
When the automatic mode is activated and the unit is running, the letters ALIT
will be flashing in alternately with the pool temperature.
16 JHER WA• OWNER'S MANUAL
xn.�.r.., um ccn"rx;ra rna�"ur>uua
=_^r ..,;,�...... ---"`^
When the automatic models activated, the unit will HEAT-the'pool when
the temperature drop 0,50F below setpoint and drill automatically switch tc
COOL mode when the temperature raise 2,5'F over set point. -
Unit will not cool:
FOR h/c UNITS: Make sure P-S is set to "POL" mode as unit will not cool in
"SPA" mode.
Connecting to a Remote System
This Pool Heater is compatible with most of all known remote systems in
the industry. The following models' diagrams show how to connect all of the
remote systems to the Electronic Temp. Controller.
For 2 wire remotes
1. Bring up "POL" setting and
arrow temperature down until
pool setting reads "OFF'.
2. Bring up "SPA" setting and
arrow temperature up until spa
setting reads 104.
3. Set unit to the "POL" mode.
4. Connect remote system with 2
wires to the POOUSPA termi-
nal on control board. Figure 6
shows you where to connect
the 2 wire remote systems to
the temperature controller.
Settings for 2-Wire Remote:
* POL; off
* SPA; 104
* P_S. Up arrow to set POL mode
Unit is now set for Remote heating
OWNER'S MANUAL THERI A -AU" 17
��aeni„ iuccs.f.cu�rm, w.rwur
4i
a+nT rin yds sN .'�aetgng e(00use tne`2rrows.,to select the desired spa
eniperature
"Set uhif'to.' POL" mode
2. Qonnect the commun and high (or spa) wires to the "POOUSPA" terminals
on control board (see specific model diagram). Low or pool wire does not
get connected.
Initial Startup
Before starting the pool heater for the first time, it is important to verify that
the breaker is in the ON position.
Also make sure that the water circulates freely and that the pool pump is activited.
Then, you will need to set the water temperature you desire. The fan will
immediately start. The compressor will start after a 3 to 4-minute delay.
When the compressor is running, the HEATING/CHAUFFAGE indicator located
on the right (see "Service Analyzer Control," p.15) should be lit. At initial startup,
it is normal for the unit to run 24 hours a day.
It is also normal to see water dripping from the holes at the base of the unit.
This is simple condensation.
18 THE OWNER'S MANUAL
ucueean�i om e,:...e�:>: roo�xmvuMo
Service Analyzer Cod
5
es -
Most problems will be detected by the service analyzer and a code,will be
displayed on the digital display of your heater.
OWNER'S MANUAL TNERl,. 19
Desired water temperature
is reached.
Main breaker is tripped.
set point above
60"F (15-C).
•aO Unit will automatically restart
when the water temperature goes
below the set point.
•90 Reset it.
The heater is displaying "flo" and it will not start.
Pool pump is not running. .e0 Turn the pool pump on.
...............................................................................................................................................
Filter is dirty, restricting •et► Backwash and clean filter.
the water flow.
The fan is running, but the compressor is not.
..............................................................................................................................................................
The heat pump is in protection •eO In this case, there may be
mode. a 5-minute delay before
restarting.
........................................ __.........................-..........................................................................................
The unit is on defrost •e4 Digital display should indicate FS.
cycle. The compressor will automatically
start again a few minutes after the
display stops indicating FS.
20 THERWAV OWNER'S MANUAL
xw-eimz... me7..� wogxu.xwP
..................................... ......... ........ ......... ..........
•e# Ask your electrician to verify your heat pump's power supply by
checking over the L1 and L2 or L1, L2 and L3 connections in the
unit's service box.
There is water around the unit.
While your THERMEAU pool •ec), To check if the water really is a
heater is in the heating mode, leak, you must stop the heater
a large quantity of warm and
and leave the pool pump running
humid air passes over the
for over 5 hours. If water is still
evaporator and causes con-
coming out of your heater after
densation. It is normal to see
this period, then call your dealer
condensation dripping under
for service.
the heater.
The heater is running but desired water
temperature cannot be reached.
.........................................................................................................................................................
eeA Heat loss is too much for the heater; cover your pool as often as
you can.
.........................................................................................................................................................
Evaporator is dirty. ae� Clean it.
.........................................................................................................................................................
•ecll, Evaporator restricted due to improper location (see section on
locating the unit).
Restricted water flow. •a+ Adjust water flow.
Note: It your pool heater does not opeate for reasons other than three mentioned above, pleasa contact
Consumer Assistance Center (see p.=) to obtain the proper aulhoriz.Yon for the warranty to apply.
OWNER'S MANUAL E 21
ncs�nnu..xn ccvxu:,urooiww. w.w
will be handled by anAuthorizedService Center. Warranty may be
ervice is not done by an Authorized Service Representative. Do not
heater to your dealer as they do not provide service.
Before calling for assistance or service, please check the "Troubleshooting"
(p.20-21) and "Warranty" (p.23-24-25) sections or call your dealer. It may save
you the cost of a service call. If you still need help, follow the instructions below.
Service can be obtained by calling one of these phone numbers.
CANADA: 1855 661-9330
76`7_'IiE'7.'fa/C7:L'!S.'_aE$Il
When asking for help, please provide a detailed description of the problem,
your heater's complete model and serial number, and the purchase date
(see p.4). This information will help us respond properly to your request.
Keep a copy of the sales receipt showing the date of purchase.
Proof of purchase will assure you warranty service.
Maintenance
Dirt can accumulate on the evaporator. You can easily remove it by using
a water spray without damaging the small aluminum fins.
The cleaning of the cabinet can be done with the help of a brush and soap.
Winterizing
First, you must turn the breaker off. The unit must be drained of all its water.
You will need to disconnect the IN and OUT water connections.
The next step is to reconnect your IN and OUT water connections that will
have previously been drained.
It is recommended to cover the heat pump to prevent snow from getting
inside.
22 THE OWNER'S MANUAL
%ESbEMLM1t Y.:C✓.u[%A:t NOLMF/TpNNP
commercial
Thermeau Industries inc. warrants that the pool heat pump will be free of defects
in workmanship and materials. The heat pump will be warranted for a period of
one (1) year. All parts and labor to correct any defect in workmanship or materials
will be the responsibility of Thermeau Industries inc.
The compressor component of the Thermeau Industries inc. pool heat pump has
a five (5) years limited warranty. During the first (1) year, the costs incurred by
the parts and labor needed to repair the compressor will be the responsibility of
Thermeau Industries inc. During years two (2), three (3), four (4) and five (5), only
parts will be covered by the warranty.
The titanium tube portion of the heat exchanger in the Thermeau Industries inc.
pool heat pump has a limited 10-year warranty. The titanium tube portion of the
heat exchanger is warranted to the original owner and at the original address.
All parts and labor are warranted for a period of one (1) year to the original home
owner. After one (1) year, only the titanium tube portion of the heat exchanger part
is warranted.
All Thermeau Industries inc. pool heat pump must be installed according to
manufacturer's specifications or the warranty will be null and void.
All warranty work must be performed by a Thermeau Industries inc. authorized
service center. All warranty work must be approved prior to service center
performing the work.
Any alteration or repair by any person, agency or company not authorized by
Thermeau Industries inc. will void the warranty. Thermeau Industries inc. is not
liable for any damages of any sort whatsoever, including incidental and conse-
quential damages. This warranty does not include damage to any internal piping
or components due to freezing conditions, negligence, abuse, routine maintenance
inspections, electrical wiring outside the heat unit, service calls caused by owner,
external valve position, refrigerant or other expendable materials, installations in
corrosive environments or atmospheres, nor acts of God. There are no particular
warranties of merchantability that apply to this product.
This warranty applies to Canada and the unites States.
Thermeau Industries inc. will replace or repair any parts that are defective providing
such parts are returned to the Thermeau Industries inc. factory, freight collect,
within the warranty period. The above is the exclusive remedy from Thermeau
Industries inc.
OWNER'S MANUAL AU' 23
W U=Artti nX'J [v^ W+ex,[4%py� NHF qMp
�ratiai:_
tFcna: warranis that the heat pump pool heater will be: free of defects
unship and materials. The heat pump will be warranted for a period of
Oars. During this period, all parts and laborto correct any defect in work -
or materials will be the responsibility of Thermeau inc.
All parts of the heat pump pool heater have a five (5) years warranty.
The titanium tube portion of the heat exchanger in the heat pump pool heater
has a limited 10-year warranty. The titanium tube portion of the heat exchanger is
warranted to the original owner and at the original installation address. All parts
and labor are warranted for a period of two (2) years to the original home owner.
After two (2) years, only the titanium tube portion of the heat exchanger part is
warranted.
The manufacturer reserves the right to replace defective parts with new or
refurbished parts at its sole discretion. All warranty work must be performed by
a Thermeau inc. authorized service center. All warranty work must be approved
prior to service center performing the work. This warranty is applicable only if
the heat pump has been installed, operated and maintained expressly and com-
pletely in accordance with the owner's manual and the manufacturer's specifica-
tions. Any alteration or repair by any person, agency or company not authorized
by Thermeau inc. will void the warranty. Thermeau inc. is not liable for any dam-
ages of any sort whatsoever, including incidental and consequential damages.
This warranty does not include damage to any internal piping or components
due to freezing conditions, negligence, abuse, routine maintenance inspections,
electrical wiring outside the heat unit, service calls caused by owner, external
valve position, refrigerant or other expendable materials, installations in corrosive
environments or atmospheres, nor Acts of God. There are no particular warranties
of merchantability that applies to this product.
This warranty applies to the USA and Canada only.
Thermeau inc. will replace or repair any parts that are defective providing such
parts are returned to the Thermeau factory, freight collect, within the warranty
period. The above is the exclusive remedy from Thermeau inc.
24 THERM OWNER'S MANUAL
xe_ _.,-... mn co.•sEk a-� roof urwr ru.�>
Warranty for the State of FlorAda .:
.. ..: ,,
Thermeau inc. warrants that the heat pump pool 'heater will be free of defects in ,
workmanship and materials.
Prestige heat pump
The Prestige heat pump will be warranted for a period of five (5) years. During this
period, all parts and labor to correct any defect in workmanship or materials will
be the responsibility of Thermeau inc. After five (5) years, only the titanium tube
portion of the heat exchanger part is warranted.
Signature heat pump
The Signature heat pump will be warranted for a period of two (2) years. During
this period, all parts and labor to correct any defect in workmanship or materials
will be the responsibility of Thermeau inc. All parts of Signature heat pump pool
heaters have a seven (7) years warranty. After seven (7) years, only the titanium
tube portion of the heat exchanger part is warranted.
The titanium tube portion of the heat exchanger in both heat pump pool heaters
has a limited 10-year warranty. The titanium tube portion of the heat exchanger is
warranted to the original owner and at the original installation address.
The manufacturer reserves the right to replace defective parts with new or
refurbished parts at its sole discretion. All warranty work must be performed by
a Thermeau inc. authorized service center. All warranty work must be approved
prior to service center performing the work. This warranty is applicable only if the
heat pump has been installed, operated and maintained expressly and completely in
accordance with the owner's manual and the manufacturer's specifications. Any
alteration or repair by any person, agency or company not authorized by Thermeau
inc, will void the warranty. Thermeau inc. is not liable for any damages of any
sort whatsoever, including incidental and consequential damages. This warranty
does not include damage to any internal piping or components due to freezing
conditions, negligence, abuse, routine maintenance inspections, electrical wiring
outside the heat unit, service calls caused by owner, external valve position, refri-
gerant or other expendable materials, installations in corrosive environments or
atmospheres, nor Acts of God. There are no particular warranties of merchanta-
bility that applies to this product. This warranty is valid for residential use only.
This warranty applies for the State of Florida only.
Thermeau inc. will replace or repair any parts that are defective providing such
parts are returned to the Thermeau factory, freight collect, within the warranty
period. The above is the exclusive remedy from Thermeau inc.
OWNERS MANUAL THER1�!� 25
x_,.onro.. n�c ceY•�:.u�vooixurww
mill-
44
•M1}
x A
• • COMMERCIAL POOL