Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: PHILIPPE RESIDENCE uilder Name: Street: PALM DRIVE JUN 23 /C?9 ermit Otfice: STLUCIECOUNTY City, State, Zip: FORT PIERCE, FL, LST.Lucie ermit Number: Owner: County, Permitting risdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or ebsting New (From Plans) 9. Wall Types (2420.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2140.70 ft' b. Frame - Wood, Adjacent R=11.0 280.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 4 d. N/A R= ft, 10. Ceiling Types (2357.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2357.00 ft 6. Conditioned floor area above grade (ft') 2357 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. N/A R= fl' 11. Ducts R ft' 7. Windaws(350.8 sqft.) Description Area a. Sup: Attic, Rel: Attic, AH: Garage 6 200 a. U-Factor SgI, U=0.65 186.83 ft' SHGC: SHGC=0.25 b. U-Factor. SgI, U=0.65 164.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 46.5 SEER:16.00 c. U-Factor. N/A fl' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft' a. Electric Strip Heat 34.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 1.167 ft. Area Weighted Average SHGC: 0.273 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2357.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2357.00 ft' b. Conservation features b. N/A R= ft' None c. N/A R= ft' 15. Credits None Glass/Floor Area: 0.149 Total Proposed Modified Loads: 81.09 PASS Total Baseline Loads: 82.42 1 hereby certify that the plans and specifications covered by Review of the plans and FKtiE SrAT this calculation are in compliance with the Florida Energy specifications covered by this �� ' ; Code. calculation indicates compliance ;FO! with the Florida Energy Cade. nun" ; r' ;.`;:•` „ �O PREPARED Y't6ano Before construction Is completed - DATE: tP this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OD WE OWNER/AGENT- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402A.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/1/2020 3:02 PM ' EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: PHILIPPE RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2357 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: PALM DRIVE Peril Office: ST LUCIE COUNTY Cross Ventilation: No County. St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Ewsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp �/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2357 24389 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 289 3179 No 0 1 1 Yes Yes Yes 2 M WIC 1 35 350 No 0 1 Yes Yes Yes 3 M W IC 2 24 240 No 0 1 No Yes Yes 4 M HALL 16 160 No 0 1 No Yes Yes 5 LINEN 8 80 No 0 1 No Yes Yes 6 M TOILET 30 300 No 0 1 Yes Yes Yes 7 M BATH 237 2370 No 0 1 Yes Yes Yes 8 LIVING ROOM 208 2288 No 0 1 Yes Yes Yes 9 OFFICE 130 1300 No 0 1 Yes Yes Yes 10 DINING ROOM 322 3542 No 0 1 Yes Yes Yes 11 KITCHEN/FAMILY 322 3220 Yes 0 1 Yes Yes Yes 12 LAUNDRY 49 490 No 0 1 No Yes Yes 13 BEDROOM 2 138 1380 No 0 1 1 Yes Yes Yes 14 CLST2 18 180 No 0 1 Yes Yes Yes 15 BATH 2 45 450 No 0 1 Yes Yes Yes 16 CLST 3 18 180 No 0 1 Yes Yes Yes 17 BEDROOM 3 156 1560 No 0 1 1 Yes Yes Yes 18 HALL 28 280 No 0 1 No Yes Yes 19 CLST 4 20 200 No 0 1 Yes Yes Yes 20 BEDROOM 4 162 1620 No 0 1 1 Yes Yes Yes 21 BATH 3 60 600 No 0 1 Yes Yes Yes 22 HALLWAY 42 420 No 0 1 Yes Yes Yes 4/1/2020 3:02 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 34 ft 0 289 ft' __ 1 0 0 2 Slab -On -Grade Edge Insulation M W IC 1 7 ft 0 35 W — 1 0 0 3 Slab -On -Grade Edge Insulation M W IC 2 1 ft 0 24 ft' ____ 1 0 0 4 Slab -On -Grade Edge Insulation M HALL 1 ft 0 16 ft' __ 1 0 0 5 Slab -On -Grade Edge Insulation LINEN 1 ft 0 8 ft' _ 1 0 0 6 Slab -On -Grade Edge Insulation M TOILET 6 ft 0 30 ft' ___ 1 0 0 7 Slab -On -Grade Edge Insulation M BATH 31.6 ft 0 237 fN ____ 1 0 0 8 Slab -On -Grade Edge Insulation LIVING ROOM 16 ft 0 208 ft' _ 1 0 0 9 Slab -On -Grade Edge Insulation OFFICE loft 0 130 ft' ___ 1 0 0 10Slab-On-Grade Edge Insulation DINING ROOM 14 ft 0 322 fP ____ 1 0 0 11SIab-On-Grade Edge Insulation KITCHEN/FAMIL 8It 0 322 W 1 0 0 1251ab-On-Grade Edge Insulation LAUNDRY 1 ft 0 49 fN 1 0 0 13SIab-On-Grade Edge Insulation BEDROOM 2 1011 0 138 ft' 1 0 0 14SIab-On-Grade Edge Insulation CLST 2 2ft 0 18 fN ___ 1 0 0 15SIab-On-Grade Edge Insulation BATH 2 5 ft 0 45 fN 1 0 0 16SIab-On-Grade Edge Insulation CLST 3 2ft 0 18 ft' ___ 1 0 0 17SIab-On-Grade Edge Insulation BEDROOM 3 12 ft 0 156 ft' ___ 1 0 0 18SIab-On-Grade Edge Insulation HALL t ft 0 28 ft' ____ 1 0 0 19SIab-On-Grade Edge Insulation CLST 4 2ft 0 20 ft' _ 1 0 0 20SIab-On-Grade Edge Insulation BEDROOM 4 25 ft 0 162 ft' -_ 1 0 0 21SIab-On-Grade Edge Insulation BATH 3 16 ft 0 60 ft' ___ 1 0 0 22SIab-On-Grade Edge Insulation HALLWAY 7ft 0 42 fN 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emltt Emitt Deck Pilch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2553 fN 0 ft' Medium N 0.6 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2357 ft' N N 4/1/2020 3:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405 2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 289 ft' 0.1 Wood 2 Under Attic (Vented) M WIC 1 30 Blown 35 ft' 0.1 Wood 3 Under Attic (Vented) M W IC 2 30 Blown 24 fP 0.1 Wood 4 Under Attic (Vented) M HALL 30 Blown 16 fN 0.1 Wood 5 Under Attic (Vented) LINEN 30 Blown 8ft' 0.1 Wood 6 Under Attic(Vented) MTOILET 30 Blown 30 ft' 0.1 Wood 7 Under Atdc (Vented) M BATH 30 Blown 237 ft' 0.1 Wood 8 Under Attic (Vented) LIVING ROOM 30 Blown 208 ft' 0.1 Wood 9 Under Attic(Vented) OFFICE 30 Blown 130 ft' 0.1 Wood 10 Under Attic (Vented) DINING ROOM 30 Blown 322 ft' 0.1 Wood 11 Under Attic (Vented) KITCHENIFAMIL 30 Blown 322 ft' 0.1 Wood 12 Under Attic (Vented) LAUNDRY 30 Blown 49 ft' 0.1 Wood 13 Under Attic (Vented) BEDROOM 2 30 Blown 138 ft' 0.1 Wood 14 Under Attic (Vented) CLST 2 30 Blown 18 ft' 0.1 Wood 15 Under Attic (Vented) BATH 2 30 Blown 45 ft' 0.1 Wood _ 16 Under Attic (Vented) CLST 3 30 Blown 18 ft' 0.1 Wood 17 Under Attic (Vented) BEDROOM 3 30 Blown 156 ft' 0.1 Wood 18 Under Attic (Vented) HALL 30 Blown 28 ft' 0.1 Wood 19 Under Attic (Vented) CLST 4 30 Blown 20 ft' 0.1 Wood _ 20 Under Attic (Vented) BEDROOM 4 30 Blown 162 ft' 0.1 Wood _ 21 Under Attic (Vented) BATH 3 30 Blown 60 ft' 0.1 Wood 22 Under Attic (Vented) HALLWAY 30 Blown 42 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Concrete Block- Ex: InstMASTER BE 4.1 17 0 11 0 187.0 ft' 0 0 0.6 0 _ 2 E Exterior Concrete Block - Ext InsAASTER BE 4.1 17 0 11 0 187.0 ft' 0 0 0.6 0 _ 3 N Exterior Concrete Block - Ext Insul M W IC 1 4.1 7 0 10 0 70.0 fN 0 0 0.6 0 4 N Exterior Concrete Block - Ext InsulM TOILET 4.1 6 0 10 0 60.0 fP 0 0 0.6 0 _ 5 N Exterior Concrete Block - Ext Insul M BATH 4.1 12 0 10 0 120.0 ft' 0 0 0.6 0 _ 6 S Exterior Concrete Block - Ext Insul M BATH 4.1 6 0 10 0 60.0 fN 0 0 0.6 0 _ 7 SW Exterior Concrete Block - Ext Insul M BATH 4.1 2 10 10 0 28.3 ft' 0 0 0.6 0 _ 8 W Exterior Concrete Block - Ext Insul M BATH 4.1 8 0 10 0 80.0 ft' 0 0 0.6 0 _ 9 NW Exterior Concrete Block - Ext Insul M BATH 4.1 2 10 10 0 28.3 ft' 0 0 0.6 0 _ 10 W Exterior Concrete Block - Ext InsdIIVING ROO 4.1 16 0 11 0 176.0 ft' 0 0 0.6 0 11 W Exterior Concrete Block - Ext Insul OFFICE 4.1 10 0 10 0 100.0 ft' 0 0 0.6 0 -12, S Garage Frame -Wood OFFICE 11 6 0 10 0 60.0 ft' 0 0.1 0.6 0 _ 13 E Exte for Concrete Block - Ext Ins011NING ROO 4.1 14 0 11 0 154.0 ft' 0 0 0.6 0 _ 14 E Exterior Concrete Block - EM InsXITCHEN/FA 4.1 8 0 10 0 80.0 ft' 0 0 0.6 0 15 W Garage Frame -Wood LAUNDRY 11 7 0 10 0 70.0W 0 0.1 0.6 0 16 S Garage Frame -Wood LAUNDRY 11 2 0 10 0 20.0 ft' 0 0.1 0.6 0 _ 17 S Exterior Concrete Block - Ext InsEEDROOM 2 4.1 10 0 10 0 100.0 ft' 0 0 0.6 0 18 W Garage Frame - Wood BEDROOM 11 13 0 10 0 130.0 fN 0 0.1 0.6 0 4/1/2020 3:02 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 19 S Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 10 0 20.0 fN 0 0 0.6 0 20 S Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 10 0 50.0 ft' 0 0 0.6 0 21 S Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 10 0 20.0 ft' 0 0 0.6 0 22 S Exterior Concrete Block - Ext InstBEDROOM 3 4.1 12 0 10 0 120.0 ft' 0 0 0.6 0 _ 23 S Exterior Concrete Block - Ext Insul CLST 4 4.1 2 0 10 0 20.0 ft' 0 0 0.6 0 _ 24 E Exterior Concrete Block - Ext InsMEDROOM 4 4.1 13 0 10 0 130.0 W 0 0 0.6 0 25 S Exterior Concrete Block -Ext lnsSEDROOM4 4.1 12 0 10 0 120.0 ft' or 0 0.6 0 _ 26 N Exterior Concrete Block - Ext Insul BATH 3 4.1 10 0 10 0 100.0 ft' 0 0 0.6 0 _ 27 E Exterior Concrete Block - Ext Insul BATH 3 4.1 6 0 10 0 60.0 fP 0 0 0.6 0 28 N Exterior Concrete Block - ExtlnsulHALLWAY 4.1 7 0 10 0 70.0ft' 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft' 1 It 2 In 2 It 0 In None None _ 2 E 2 Metal Low-E Single Yes 0.65 0.3 N 48.0 ft' 1 It 2 in 2 ft 0 in None None 3 SW 7 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft' 1 ft 2 in 1 ft 0 In None None 4 W 8 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft' 1 ft 2 in 1 ft 0 in None None 5 NW 9 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft' 1 ft 2 in 1 ft 0 in None None _ 6 W 10 Metal Low-E Single Yes 0.65 0.25 N 20.4 ft' 1 ft 2 In 0 ft 6 in None None 7 W 10 Metal Low-E Single Yes 0.65 0.3 N 48.0 ft' 1 ft 2 In 0 It 4 In None None 8 W 11 Metal Low-E Single Yes 0.65 0.25 N 20.4 ft' 1 ft 2 in 0 ft 4 in None None 9 E 13 Metal Law-E Single Yes 0.65 0.3 N 48.0 ft' 1 ft 2 in 2 It 0 in None None _ 10 E 14 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft' 1 ft 2 in 2 It 0 in None None 11 S 17 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft' 1 ft 2 in 2 It 0In None None 12 S 20 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft' 1 ft 2 in 2 ft 0 In None None 13 S 22 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft' 1 ft 2 in 2 ft 0 In None None 14 S 25 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft' 1 ft 2 in 2 ft 0 in None None 15 N 26 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft' 1 ft 2 in 2 ft 0 in None None 16 N 28 Metal Low-E Single Yes 0.65 0.3 N 20.0 fP 1 ft 2 in 3 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 fP 440 W 28 ft 10 it 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgtA ACH ACH 50 1 Wholehouse Proposed ACH(50) .00046 2845A 156.21 293.77 .1768 7 4/1/2020 3:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Duds 1 Electric Strip Heat/ None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Black Ducts 1 Central Unit/ Split Single SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None - SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # Company Name System Model # Collector Model # Area Volume FEF None None fN DUCTS _ / —Supply— —Return--- Air CFM25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heal Cool 1 Attic 6 200 fP Attic 20 ft- Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES ProgramableThermostat: N Ceiling Fans: Coolin [[ ]]Jan [[ ]] Feb [[ ]] Mar Heating [X] Jan [X] Feb [XJ Mar ] Apr E ] Apr f ] M [XJ Jun fX� Jul [ ]May [ ]Jun [ ]Jul [ ]AuE J1 Au Se ] Sep ] Oct [ ] Nov E ] Oct [X] Nov [ ] Dec [XJ Dec Ventin l 1 Jan [ 1 Feb [XI Mar IXI Apr [ 1 May [ 1 Jun I 1 Jul l 1 Aug [ 1 Se [Xl Oct [Rl Nov [ 1 Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(B Ibs/sq.ft. oft. 0 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.fL fP It 0.3 M W IC 1 Default(8 Ibs/sq.ft. fl' ft 0.3 M W IC 2 Default(8 IbslsgJt. fN ft 0.3 M HALL Default(8lbs/sq.ft. fN If 0.3 LINEN Default(8 Ibs/sq.ft. fN ft 0.3 M TOILET Default(8 Ibs/sq.ft. it, it 0.3 M BATH Default(8 Ibslsq.ft. fP ft 0.3 LIVING ROOM 4/1/2020 3:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft, ft 0.3 OFFICE Default(8 lbs/sq.ft. fN ft 0.3 DINING ROOM Default(8 lbs/sq.fl. fP ft 0.3 KITCHEN/FAMILY Defauft(8 lbs/sq.ft. fl' ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. fN ft 0.3 BEDROOM Default(8 Ibs/sq.ft. fP ft 0.3 CLST 2 Defauft(8 lbs/sq.ft. ft, ft 0.3 BATH 2 Default(8 Ibs/sq.ft. fp ft 0.3 CLST 3 Defauft(8 Ibs/sq.ft. fP ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. fl' ft 0.3 HALL Default(8 Ibs/sq.ft. fN It 0.3 CLST 4 Default(8 Ibs/sq.ft. fN It 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft' ft 0.3 BATH 3 Default 816s/s .fl. fN ft 0.3 HALLWAY 4/1/2020 3:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2047 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: PHILIPPE RESIDENCE Builder Name: Street: PALM DRIVE PermitOffice: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: ST LUCIE COUNTY w x Design Location: FL, Fart Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not he used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ce ling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The Insulation In any dropped ceiling/soffit Insulation and any gaps In the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be Insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall Include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be Installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subf lour decking, or floor framing cavity Insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be f lled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed In the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on Installation readily conforms to available space shall extend behind pipincl and wirin . Shower/tub The air barrier Installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilincis, a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/1/2020 3:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location $ insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (If multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 46.5 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2357 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.273 14. Heating system: Capacity 34.0 c) Area 7c. 350.8 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, Insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) In this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Address of New Home: PALM DRIVE City/FL Zip: FORT PIERCE, FL 4/1/2020 3:02:46 PM EnergyGauge@ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1