HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: PHILIPPE RESIDENCE
uilder Name:
Street: PALM DRIVE
JUN 23 /C?9
ermit Otfice: STLUCIECOUNTY
City, State, Zip: FORT PIERCE, FL,
LST.Lucie
ermit Number:
Owner:
County, Permitting risdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County. St. Lucie (Florida Climate Zone 2 )
1. New construction or ebsting
New (From Plans)
9. Wall Types (2420.7 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2140.70 ft'
b. Frame - Wood, Adjacent
R=11.0 280.00 ft'
3. Number of units, if multiple family
1
c. N/A
R= ft'
4. Number of Bedrooms
4
d. N/A
R= ft,
10. Ceiling Types (2357.0 sqft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 2357.00 ft
6. Conditioned floor area above grade (ft')
2357
b. N/A
R= ft'
Conditioned floor area below grade (W)
0
c. N/A
R= fl'
11. Ducts
R ft'
7. Windaws(350.8 sqft.) Description
Area
a. Sup: Attic, Rel: Attic, AH: Garage
6 200
a. U-Factor SgI, U=0.65
186.83 ft'
SHGC: SHGC=0.25
b. U-Factor. SgI, U=0.65
164.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
46.5 SEER:16.00
c. U-Factor. N/A
fl'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A
ft'
a. Electric Strip Heat
34.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth:
1.167 ft.
Area Weighted Average SHGC:
0.273
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2357.0 sqft.)
Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation
R=0.0 2357.00 ft'
b. Conservation features
b. N/A
R= ft'
None
c. N/A
R= ft'
15. Credits
None
Glass/Floor Area: 0.149
Total Proposed Modified Loads: 81.09
PASS
Total Baseline Loads: 82.42
1 hereby certify that the plans and specifications covered by
Review of the plans and
FKtiE SrAT
this calculation are in compliance with
the Florida Energy
specifications covered by this
�� ' ;
Code.
calculation indicates compliance
;FO!
with the Florida Energy Cade.
nun" ; r' ;.`;:•` „ �O
PREPARED Y't6ano
Before construction Is completed
-
DATE: tP
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
OD WE
OWNER/AGENT-
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402A.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/1/2020 3:02 PM ' EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
PHILIPPE RESIDENCE
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2357
Lot #
Owner Name:
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
PALM DRIVE
Peril Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County.
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Ewsting:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design DailyTemp
�/ Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2357
24389
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
MASTER BEDROO
289
3179
No
0
1
1
Yes
Yes
Yes
2
M WIC 1
35
350
No
0
1
Yes
Yes
Yes
3
M W IC 2
24
240
No
0
1
No
Yes
Yes
4
M HALL
16
160
No
0
1
No
Yes
Yes
5
LINEN
8
80
No
0
1
No
Yes
Yes
6
M TOILET
30
300
No
0
1
Yes
Yes
Yes
7
M BATH
237
2370
No
0
1
Yes
Yes
Yes
8
LIVING ROOM
208
2288
No
0
1
Yes
Yes
Yes
9
OFFICE
130
1300
No
0
1
Yes
Yes
Yes
10
DINING ROOM
322
3542
No
0
1
Yes
Yes
Yes
11
KITCHEN/FAMILY
322
3220
Yes
0
1
Yes
Yes
Yes
12
LAUNDRY
49
490
No
0
1
No
Yes
Yes
13
BEDROOM 2
138
1380
No
0
1
1
Yes
Yes
Yes
14
CLST2
18
180
No
0
1
Yes
Yes
Yes
15
BATH 2
45
450
No
0
1
Yes
Yes
Yes
16
CLST 3
18
180
No
0
1
Yes
Yes
Yes
17
BEDROOM 3
156
1560
No
0
1
1
Yes
Yes
Yes
18
HALL
28
280
No
0
1
No
Yes
Yes
19
CLST 4
20
200
No
0
1
Yes
Yes
Yes
20
BEDROOM 4
162
1620
No
0
1
1
Yes
Yes
Yes
21
BATH 3
60
600
No
0
1
Yes
Yes
Yes
22
HALLWAY
42
420
No
0
1
Yes
Yes
Yes
4/1/2020 3:02 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO
34 ft
0
289 ft'
__
1
0
0
2 Slab -On -Grade Edge Insulation
M W IC 1
7 ft
0
35 W
—
1
0
0
3 Slab -On -Grade Edge Insulation
M W IC 2
1 ft
0
24 ft'
____
1
0
0
4 Slab -On -Grade Edge Insulation
M HALL
1 ft
0
16 ft'
__
1
0
0
5 Slab -On -Grade Edge Insulation
LINEN
1 ft
0
8 ft'
_
1
0
0
6 Slab -On -Grade Edge Insulation
M TOILET
6 ft
0
30 ft'
___
1
0
0
7 Slab -On -Grade Edge Insulation
M BATH
31.6 ft
0
237 fN
____
1
0
0
8 Slab -On -Grade Edge Insulation
LIVING ROOM
16 ft
0
208 ft'
_
1
0
0
9 Slab -On -Grade Edge Insulation
OFFICE
loft
0
130 ft'
___
1
0
0
10Slab-On-Grade Edge Insulation
DINING ROOM
14 ft
0
322 fP
____
1
0
0
11SIab-On-Grade Edge Insulation
KITCHEN/FAMIL
8It
0
322 W
1
0
0
1251ab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
49 fN
1
0
0
13SIab-On-Grade Edge Insulation
BEDROOM 2
1011
0
138 ft'
1
0
0
14SIab-On-Grade Edge Insulation
CLST 2
2ft
0
18 fN
___
1
0
0
15SIab-On-Grade Edge Insulation
BATH 2
5 ft
0
45 fN
1
0
0
16SIab-On-Grade Edge Insulation
CLST 3
2ft
0
18 ft'
___
1
0
0
17SIab-On-Grade Edge Insulation
BEDROOM 3
12 ft
0
156 ft'
___
1
0
0
18SIab-On-Grade Edge Insulation
HALL
t ft
0
28 ft'
____
1
0
0
19SIab-On-Grade Edge Insulation
CLST 4
2ft
0
20 ft'
_
1
0
0
20SIab-On-Grade Edge Insulation
BEDROOM 4
25 ft
0
162 ft'
-_
1
0
0
21SIab-On-Grade Edge Insulation
BATH 3
16 ft
0
60 ft'
___
1
0
0
22SIab-On-Grade Edge Insulation
HALLWAY
7ft
0
42 fN
1
0
0
ROOF
Roof
Gable
Roof
Rad
Solar SA Emltt
Emitt
Deck
Pilch
V # Type Materials Area
Area
Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Composition shingles 2553 fN
0 ft'
Medium
N
0.6 No 0.9
No
0
22.6
ATTIC
/
V # Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Vented
150
2357 ft'
N N
4/1/2020 3:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405 2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) MASTER BEDRO 30
Blown
289 ft'
0.1
Wood
2
Under Attic (Vented) M WIC 1
30
Blown
35 ft'
0.1
Wood
3
Under Attic (Vented) M W IC 2
30
Blown
24 fP
0.1
Wood
4
Under Attic (Vented) M HALL
30
Blown
16 fN
0.1
Wood
5
Under Attic (Vented) LINEN
30
Blown
8ft'
0.1
Wood
6
Under Attic(Vented) MTOILET
30
Blown
30 ft'
0.1
Wood
7
Under Atdc (Vented) M BATH
30
Blown
237 ft'
0.1
Wood
8
Under Attic (Vented) LIVING ROOM
30
Blown
208 ft'
0.1
Wood
9
Under Attic(Vented) OFFICE
30
Blown
130 ft'
0.1
Wood
10
Under Attic (Vented) DINING ROOM
30
Blown
322 ft'
0.1
Wood
11
Under Attic (Vented) KITCHENIFAMIL 30
Blown
322 ft'
0.1
Wood
12
Under Attic (Vented) LAUNDRY
30
Blown
49 ft'
0.1
Wood
13
Under Attic (Vented) BEDROOM 2
30
Blown
138 ft'
0.1
Wood
14
Under Attic (Vented) CLST 2
30
Blown
18 ft'
0.1
Wood
15
Under Attic (Vented) BATH 2
30
Blown
45 ft'
0.1
Wood
_
16
Under Attic (Vented) CLST 3
30
Blown
18 ft'
0.1
Wood
17
Under Attic (Vented) BEDROOM 3
30
Blown
156 ft'
0.1
Wood
18
Under Attic (Vented) HALL
30
Blown
28 ft'
0.1
Wood
19
Under Attic (Vented) CLST 4
30
Blown
20 ft'
0.1
Wood
_
20
Under Attic (Vented) BEDROOM 4
30
Blown
162 ft'
0.1
Wood
_
21
Under Attic (Vented) BATH 3
30
Blown
60 ft'
0.1
Wood
22
Under Attic (Vented) HALLWAY
30
Blown
42 ft'
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
1
N
Exterior Concrete Block- Ex: InstMASTER BE
4.1
17
0 11
0
187.0 ft'
0
0
0.6
0
_ 2
E
Exterior Concrete Block - Ext InsAASTER BE
4.1
17
0 11
0
187.0 ft'
0
0
0.6
0
_ 3
N
Exterior Concrete Block - Ext Insul M W IC 1
4.1
7
0 10
0
70.0 fN
0
0
0.6
0
4
N
Exterior Concrete Block - Ext InsulM TOILET
4.1
6
0 10
0
60.0 fP
0
0
0.6
0
_ 5
N
Exterior Concrete Block - Ext Insul M BATH
4.1
12
0 10
0
120.0 ft'
0
0
0.6
0
_ 6
S
Exterior Concrete Block - Ext Insul M BATH
4.1
6
0 10
0
60.0 fN
0
0
0.6
0
_ 7
SW
Exterior Concrete Block - Ext Insul M BATH
4.1
2
10 10
0
28.3 ft'
0
0
0.6
0
_ 8
W
Exterior Concrete Block - Ext Insul M BATH
4.1
8
0 10
0
80.0 ft'
0
0
0.6
0
_ 9
NW
Exterior Concrete Block - Ext Insul M BATH
4.1
2
10 10
0
28.3 ft'
0
0
0.6
0
_ 10
W
Exterior Concrete Block - Ext InsdIIVING ROO
4.1
16
0 11
0
176.0 ft'
0
0
0.6
0
11
W
Exterior Concrete Block - Ext Insul OFFICE
4.1
10
0 10
0
100.0 ft'
0
0
0.6
0
-12,
S
Garage Frame -Wood OFFICE
11
6
0 10
0
60.0 ft'
0
0.1
0.6
0
_ 13
E
Exte for Concrete Block - Ext Ins011NING ROO
4.1
14
0 11
0
154.0 ft'
0
0
0.6
0
_ 14
E
Exterior Concrete Block - EM InsXITCHEN/FA
4.1
8
0 10
0
80.0 ft'
0
0
0.6
0
15
W
Garage Frame -Wood LAUNDRY
11
7
0 10
0
70.0W
0
0.1
0.6
0
16
S
Garage Frame -Wood LAUNDRY
11
2
0 10
0
20.0 ft'
0
0.1
0.6
0
_ 17
S
Exterior Concrete Block - Ext InsEEDROOM 2
4.1
10
0 10
0
100.0 ft'
0
0
0.6
0
18
W
Garage Frame - Wood BEDROOM
11
13
0 10
0
130.0 fN
0
0.1
0.6
0
4/1/2020 3:02 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
19
S
Exterior
Concrete Block - Ext Insul CLST 2
4.1
2
0
10 0
20.0 fN
0
0
0.6
0
20
S
Exterior
Concrete Block - Ext Insul BATH 2
4.1
5
0
10 0
50.0 ft'
0
0
0.6
0
21
S
Exterior
Concrete Block - Ext Insul CLST 3
4.1
2
0
10 0
20.0 ft'
0
0
0.6
0
22
S
Exterior
Concrete Block - Ext InstBEDROOM 3
4.1
12
0
10 0
120.0 ft'
0
0
0.6
0
_ 23
S
Exterior
Concrete Block - Ext Insul CLST 4
4.1
2
0
10 0
20.0 ft'
0
0
0.6
0
_ 24
E
Exterior
Concrete Block - Ext InsMEDROOM 4
4.1
13
0
10 0
130.0 W
0
0
0.6
0
25
S
Exterior
Concrete Block -Ext lnsSEDROOM4
4.1
12
0
10 0
120.0 ft'
or
0
0.6
0
_ 26
N
Exterior
Concrete Block - Ext Insul BATH 3
4.1
10
0
10 0
100.0 ft'
0
0
0.6
0
_ 27
E
Exterior
Concrete Block - Ext Insul BATH 3
4.1
6
0
10 0
60.0 fP
0
0
0.6
0
28
N
Exterior
Concrete Block - ExtlnsulHALLWAY
4.1
7
0
10 0
70.0ft'
0
0
0.6
0
WINDOWS
Orientation shown
is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor SHGC
Imp Area
Depth
Separation
Int Shade
Screening
1
N
1
Metal Low-E Single Yes
0.65
0.25
N
20.0 ft'
1 It 2 In
2 It 0 In
None
None
_
2
E
2
Metal Low-E Single Yes
0.65
0.3
N
48.0 ft'
1 It 2 in
2 ft 0 in
None
None
3
SW 7
Metal Low-E Single Yes
0.65
0.25
N
8.0 ft'
1 ft 2 in
1 ft 0 In
None
None
4
W
8
Metal Low-E Single Yes
0.65
0.25
N
12.0 ft'
1 ft 2 in
1 ft 0 in
None
None
5
NW 9
Metal Low-E Single Yes
0.65
0.25
N
8.0 ft'
1 ft 2 in
1 ft 0 in
None
None
_
6
W
10
Metal Low-E Single Yes
0.65
0.25
N
20.4 ft'
1 ft 2 In
0 ft 6 in
None
None
7
W
10
Metal Low-E Single Yes
0.65
0.3
N
48.0 ft'
1 ft 2 In
0 It 4 In
None
None
8
W
11
Metal Low-E Single Yes
0.65
0.25
N
20.4 ft'
1 ft 2 in
0 ft 4 in
None
None
9
E
13
Metal Law-E Single Yes
0.65
0.3
N
48.0 ft'
1 ft 2 in
2 It 0 in
None
None
_
10
E
14
Metal Low-E Single Yes
0.65
0.25
N
20.0 ft'
1 ft 2 in
2 It 0 in
None
None
11
S
17
Metal Low-E Single Yes
0.65
0.25
N
20.0 ft'
1 ft 2 in
2 It 0In
None
None
12
S
20
Metal Low-E Single Yes
0.65
0.25
N
9.0 ft'
1 ft 2 in
2 ft 0 In
None
None
13
S
22
Metal Low-E Single Yes
0.65
0.25
N
20.0 ft'
1 ft 2 in
2 ft 0 In
None
None
14
S
25
Metal Low-E Single Yes
0.65
0.25
N
20.0 ft'
1 ft 2 in
2 ft 0 in
None
None
15
N
26
Metal Low-E Single Yes
0.65
0.25
N
9.0 ft'
1 ft 2 in
2 ft 0 in
None
None
16
N
28
Metal Low-E Single Yes
0.65
0.3
N
20.0 fP
1 ft 2 in
3 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
440 fP 440 W
28 ft
10 it
11
INFILTRATION
#
Scope
Method SLA CFM 50
ELA
EgtA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .00046 2845A
156.21
293.77
.1768
7
4/1/2020 3:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Duds
1 Electric Strip Heat/
None
COPA
34 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR Black
Ducts
1 Central Unit/
Split
Single SEER: 16
46.5 kBtu/hr 1395 cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.98 50 gal
62.3 gal
120 deg
None
-
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Carl # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
fN
DUCTS
_ / —Supply—
—Return---
Air
CFM25
CFM25
HVAC#
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON RLF
Heal Cool
1 Attic 6 200 fP
Attic
20 ft- Default Leakage
Garage
(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: N
Ceiling Fans:
Coolin [[ ]]Jan [[ ]] Feb [[ ]] Mar
Heating [X] Jan [X] Feb [XJ Mar
] Apr
E ] Apr
f ] M [XJ Jun fX� Jul
[ ]May [ ]Jun [ ]Jul
[ ]AuE
J1 Au
Se
] Sep
] Oct [ ] Nov
E ] Oct [X] Nov
[ ] Dec
[XJ Dec
Ventin l 1 Jan [ 1 Feb [XI Mar
IXI Apr
[ 1 May [ 1 Jun I 1 Jul
l 1 Aug
[ 1 Se
[Xl Oct [Rl Nov
[ 1 Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9
10 11
12
Cooling(WD) AM 78
78 78
78 78 78
78
78
80
80 80
80
PM 80
80 80
80 78 78
78
78
78
78 78
78
Cooling(WEH) AM 78
78 78
78 78 78
78
78
80
80 80
80
PM 80
80 80
80 78 78
78
78
78
78 78
78
Heating (WD) AM 65
65 65
65 65 65
65
68
68
68 68
68
PM 68
68 68
68 68 68
68
68
68
68 68
68
Heating(WEH) AM 65
65 65
65 65 65
65
68
68
68 68
68
PM 68
68 68
68 68 68
68
68
68
68 68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(B Ibs/sq.ft.
oft.
0 ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.fL
fP
It
0.3
M W IC 1
Default(8 Ibs/sq.ft.
fl'
ft
0.3
M W IC 2
Default(8 IbslsgJt.
fN
ft
0.3
M HALL
Default(8lbs/sq.ft.
fN
If
0.3
LINEN
Default(8 Ibs/sq.ft.
fN
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
it,
it
0.3
M BATH
Default(8 Ibslsq.ft.
fP
ft
0.3
LIVING ROOM
4/1/2020 3:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
ft,
ft
0.3
OFFICE
Default(8 lbs/sq.ft.
fN
ft
0.3
DINING ROOM
Default(8 lbs/sq.fl.
fP
ft
0.3
KITCHEN/FAMILY
Defauft(8 lbs/sq.ft.
fl'
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
fN
ft
0.3
BEDROOM
Default(8 Ibs/sq.ft.
fP
ft
0.3
CLST 2
Defauft(8 lbs/sq.ft.
ft,
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
fp
ft
0.3
CLST 3
Defauft(8 Ibs/sq.ft.
fP
ft
0.3
BEDROOM 3
Default(8 lbs/sq.ft.
fl'
ft
0.3
HALL
Default(8 Ibs/sq.ft.
fN
It
0.3
CLST 4
Default(8 Ibs/sq.ft.
fN
It
0.3
BEDROOM 4
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BATH 3
Default 816s/s .fl.
fN
ft
0.3
HALLWAY
4/1/2020 3:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
2047 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: PHILIPPE RESIDENCE Builder Name:
Street: PALM DRIVE PermitOffice: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner: Jurisdiction: ST LUCIE COUNTY
w
x
Design Location: FL, Fart Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not he used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ce ling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The Insulation In any dropped ceiling/soffit
Insulation and any gaps In the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be Insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall Include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be Installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subf lour decking, or floor framing cavity Insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be f lled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed In the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
Installation readily conforms to available space shall
extend behind pipincl and wirin .
Shower/tub
The air barrier Installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilincis,
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/1/2020 3:03 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location $ insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Garage
3. No. of units (If multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
46.5
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2357
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.273
14. Heating system: Capacity
34.0
c) Area
7c.
350.8
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, Insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) In this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:
Address of New Home: PALM DRIVE City/FL Zip: FORT PIERCE, FL
4/1/2020 3:02:46 PM EnergyGauge@ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1