HomeMy WebLinkAboutReview Comments��rsGto �2�tsss� Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Plerce,FL 34982 PROPERTY INFORMATION Address: 5901 Palm Dr City / State / Zip: Fort Pierce, FI 34982 Parcel #: 3402-609-0357-000/9 Zoning: REVIEW COMMENTS 1 Owner(s): Marivic Philippe / Ocles P Philippe Jurisdiction: SAINT LUCIE COUNTY Lot#: 39 Block: 61 APPLICATION INFORMATION Permit Number: 2004-0622 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) Contractor Name: Business Name: Business Addr: City I State / Zip: Automatic Sprinkler System? No Fax Number: Email: REVIEWS AND COMMENTS Review Tvoe Status Reviewed By Date Started Date Completed Data Released ADDRESSING ASSIGNMENT PENDING Comment: DOCUMENTS MISSING PENDING Heather Burford 4/30/2020 Comment: NEEDS NOC 4/30/2020 Comment: NEEDS SUB AGREEMENT FORMS Comment: VEG PERMIT FILED IN DRAWER UNDER "P" FOR PHILLIPPE, FEE LOADED 4/30/2020 VEGGIE PERMIT WAS DROPPED OFF DOWNSTAIRS BY OWNER SEPERATE 5/1/2020 Comment: PLEASE PROVIDE PAID UTILITIES RECEIPT FROM ST LUCIE COUNTY. 5/l/2020 Comment: PLEASE OBTAIN DRIVEWAY PERMIT FROM ROAD AND BRIDGE. ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzel 5/1812020 512012020 Comment: FRONT COUNTER REVIEW COMPLETE Heather Burford Comment: NOTIFIED FOR PICK UP PENDING Comment: 5120/2020 4/3012020 4130/2020 .��F _14�14w'.'5FJ�� Planning & Development Services BuIlding & Code Regulation Division 2300 Virginia Avenue Fort Pierce. FL 34982 REVIEW COMMENTS PLANS EXAMINER REVIEW INCOMPLETE William Durden 512712020 Comment: TRUSS DRAWINGS NOT REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL IN CHARGE. 5127/2020 • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE. Comment: ONLY ONE COPY OF THE TRUSS ENGINEERING WAS SUBMITTED FOR REVIEW. 5/27/2020 • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2017 FLORIDA BUILDING CODE. Comment: TRUSS ENGINEERING HAS THE ENGINEERS SEAL, BUT IS NOT SIGNED. • THE TRUSS ENGINEERING MUST HAVE THE ORIGINAL SIGNATURE OF THE TRUSS MANUFACTURER'S 5/27/2020 ENGINEER. REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL IN CHARGE. PLEASE CORRECT AND SUBMIT IN DUPLICATE. IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE. AND CHAPTER 8 SECTION R802 SUBSECTION R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: • COULD NOT COMPLETE MY REVIEW DUE TO ONLY ONE SET OF PRODUCT APPROVALS WERE 5/27/2020 SUBMITTED FOR THE REVIEW. PLEASE SUBMIT ALL DOCUMENTS IN DUPLICATE. PLEASE SEE CHAPTER 1 SECTION [A] 107.2.1 OF THE 2017 FLORIDA BUILDING CODE. Comment: • NO PRODUCT APPROVAL NUMBER WAS SUBMITTED FOR THE WINDOW MULL BARS. PLEASE SUBMIT 5127/2020 THE CORRECT PRODUCT APPROVAL NUMBER ON PLANS OR SUBMIT THE PRODUCT APPROVAL IN DUPLICATE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: • NO PRODUCT APPROVAL NUMBER WAS SUBMITTED FOR THE ARCHED WINDOWS. PLEASE SUBMIT THE 5/27/2020 CORRECT PRODUCT APPROVAL NUMBER ON PLANS OR SUBMIT THE PRODUCT APPROVAL IN DUPLICATE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: • NO PRODUCT APPROVAL NUMBER WAS SUBMITTED FOR THE ROOF UNDERLAYMENT. PLEASE SUBMIT 5127/2020 THE CORRECT PRODUCT APPROVAL NUMBER ON PLANS OR SUBMIT THE PRODUCT APPROVAL IN DUPLICATE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: GENERAL NOTES ON PAGE A-2 CALLS OUT FOR OPENING PROTECTION, PRODUCT REVIEW AFFIDAVIT 5/2712020 CALLS OUT FOR IMPACT WINDOWS. IF ADDING OPENING PROTECTION PLEASE ADD THE PRODUCT INFORMATION TO THE PRODUCT REVIEW AFFIDAVIT, OR PLEASE REMOVE THE NOTE FROM THE PLANS. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE, Comment: NOT ENOUGH INFORMATION ON THE SURVEY TO COMPLETE MY REVIEW OF THE STORM WATER REQUIREMENTS. 5/27/2020 1. PROVIDE A REVISED ENGINEERED DRAINAGE PLAN THAT MEETS THE REQUIREMENTS OF THE FILLED LANDS AFFIDAVIT AND FLORIDA RESIDENTIAL CODE SECTION R401.3. 2. PROVIDE AN UPDATED SEALED SURVEY THAT IDENTIFIES ALL COMPONENTS OF STORMWATER CONTROL AND VERIFIES FIELD COMPLIANCE WITH APPROVED DRAINAGE PLAN. Comment: SURVEY CALLS OUT 30" ABOVE THE ROAD. PLEASE SEE THE 2017 FLORIDA RESIDENTIAL BUILDING CODE, 5/27/2020 CHAPTER 5, SECTION 506, SUB -SECTION 506.2.1.. (THE FILL DEPTHS SHALL NOT EXCEED 24 INCHES (610 MM) FOR CLEAN SAND OR GRAVEL AND 8 INCHES (203 MM) FOR EARTH.) Comment: UNABLE TO COMPLETE MY REVIEW DUE TO ONLY ONE ENERGY CALC AND MANUAL J SUBMITTED FOR REVIEW. 5127/2020 • PLEASE FURNISH ENERGY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 OF THE 2017 FLORIDA ENERGY CODE. NOTE ONLY, ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER Planning E Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 ZONING REVIEW 5l1/2020 5/12020 REVIEW COMMENTS 3 INCOMPLETE ' Angela Vassar 5/1/2020 Comment: THE SURVEYS ARE INCOMPLETE. PLEASE PROVIDE TWO CORRECTED SEALED SURVEYS WITH THE FOLLOWING INFORMATION: *PLEASE CORRECT THE FLOOD PANEL. OUR RECORDS SHOW THE PROPERTY LIES IN PANEL 281 K. 'PLEASE SHOW THE DIMENSIONS OF THE ENTRY. *PLEASE SHOW THE DIMENSIONS OF THE COVERED PORCH. 'PLEASE PROVIDE THE PROPOSED FINISHED FLOOR ELEVATION. 'FLOOD PANEL IS CORRECTED. 'DIMENSIONS OF ENTRY ARE SHOWN. 'FINISHED FLOOR ELEVATION IS SHOWN; HOWEVER NOT MEETING CENTERLINE OF ROAD. CH 7.01.04 OF THE ST LUCIE COUNTY LAND DEVELOPMENT CODE STATES ALL HABITABLE STRUCTURES MUST BE ELEVATED A MINIMUM OF 18" ABOVE THE CENTERLINE OF ADJACENT ROADWAY. 'THE SURVEY STILL REFLECTS A COVERED PORCH; PLEASE CORRECT. *PLEASE SUBMIT TWO SEALED SURVEYS (I RECEIVED ONE SEALED AND TWO NOT SEALED). Comment: PLEASE PROVIDE THESE ITEMS WITH APPROVAL FROM HEALTH DEPARTMENT: -TWO SURVEYS (NO NEED TO BE SEALED) *TWO FLOOR PLANS 'SEPTIC PERMIT 5/12020 Comment: THE PLAN REVIEWER MAY HAVE ADDITIONAL COMMENTS.