HomeMy WebLinkAboutWILLIAMS RES.-ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 57/16/2020 4:28 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: WILLIAMS RESIDENCE Street: City, State, Zip: FT. PIERCE , FL , 5203 MATANZAS AVENUE Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) Existing (Projected Single-family 1 No 816 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.79 90.08 ft² SHGC=0.50 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 816.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Ext Insul, Exterior R=4.1 940.75 ft² b. N/A R=f t ² c. N/A R=f t ² 10. Ceiling Types a. Under Attic (Vented)R=19.0 816.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: BEDROOM 12. Cooling systems 13. Heating systems 14. Hot water systems a . b. Conservation features d. N/A R=f t ² Area Weighted Average Overhang Depth:2.000 ft. Area Weighted Average SHGC:0.500 Description Area Insulation Area Insulation Area Insulation Area 15. Credits CF, Pstat 2 (90.1 sqft.) (940.8 sqft.) (816.0 sqft.) (816.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 28.2 SEER:14.00 Efficiency k B t u / h r Efficiency 17.0 COP:1.00 f t ² R 6 75 EF: -3.42372E022 Glass/Floor Area: 0.110 Total Proposed Modified Loads: Total Baseline Loads: 34.35 34.60 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 7-16-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: 1 WILLIAMS RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 816 2 Existing (Projected) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FT. PIERCE , St. Lucie 5203 MATANZAS AVEN Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 816 6528 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 MASTER BED 130 1040 No 2 1 Yes Yes1 Yes 2 BEDROOM 81 648 No 0 1 Yes Yes1 Yes 3 BATH 63 504 No 0 Yes Yes1 Yes 4 KITCHEN 90 720 Yes 0 Yes Yes1 Yes 5 PANTRY 72 576 No 0 Yes Yes1 Yes 6 LIVING 380 3040 No 2 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 130 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -023 ft MASTER BED 2 81 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -018 ft BEDROOM 3 63 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -07 ft BATH 4 90 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -010 ft KITCHEN 5 72 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -017 ft PANTRY 6 380 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -041 ft LIVING 7/16/2020 4:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Gable or shed Composition shingles 860 ft² Light 0.5 0 18.4______ No136 ft² 0.6 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 816 ft² N N150 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented) 19 130 ft² 0.1 Wood______ MASTER BED Blown 2 Under Attic (Vented) 19 81 ft² 0.1 Wood______ BEDROOM Blown 3 Under Attic (Vented) 19 63 ft² 0.1 Wood______ BATH Blown 4 Under Attic (Vented) 19 90 ft² 0.1 Wood______ KITCHEN Blown 5 Under Attic (Vented) 19 72 ft² 0.1 Wood______ PANTRY Blown 6 Under Attic (Vented) 19 380 ft² 0.1 Wood______ LIVING Blown WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0MASTER BE 00013 8N Concrete Block - Ext Insul 0.40Exterior 104.0 ft² ____ 2 4.1 0MASTER BE 00010 8E Concrete Block - Ext Insul 0.40Exterior 80.0 ft² ____ 3 4.1 0BEDROOM 0509 9E Concrete Block - Ext Insul 0.40Exterior 84.8 ft² ____ 4 4.1 0BEDROOM 0009 8S Concrete Block - Ext Insul 0.40Exterior 72.0 ft² ____ 5 4.1 0BATH 0007 8S Concrete Block - Ext Insul 0.40Exterior 56.0 ft² ____ 6 4.1 0KITCHEN 00010 8S Concrete Block - Ext Insul 0.40Exterior 80.0 ft² ____ 7 4.1 0PANTRY 0008 8S Concrete Block - Ext Insul 0.40Exterior 64.0 ft² ____ 8 4.1 0PANTRY 0009 8W Concrete Block - Ext Insul 0.40Exterior 72.0 ft² ____ 9 4.1 0LIVING 00021 8N Concrete Block - Ext Insul 0.40Exterior 168.0 ft² ____ 10 4.1 0LIVING 0005 8E Concrete Block - Ext Insul 0.40Exterior 40.0 ft² ____ 11 4.1 0LIVING 00015 8W Concrete Block - Ext Insul 0.40Exterior 120.0 ft² ____ # Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .28 20.4 ft² None______ S PANTRY 7112 2 Insulated .28 21 ft² None______ N LIVING 73 3 Insulated .28 21 ft² None______ E LIVING 73 7/16/2020 4:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 N Single (Clear) 0.79 0.5 17.3 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes1 N 2 S Single (Clear) 0.79 0.5 12.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes4 N 3 S Single (Clear) 0.79 0.5 4.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes5 N 4 S Single (Clear) 0.79 0.5 9.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes6 N 5 N Single (Clear) 0.79 0.5 17.3 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes9 N 6 N Single (Clear) 0.79 0.5 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes9 N 7 W Single (Clear) 0.79 0.5 15.4 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes11 N Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 544 529.86.000254Wholehouse .088156.17Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Strip Heat/ COP:1 17 kBtu/hr ______ sys#1None 1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/ SEER: 14 28.2 kBtu/hr c f m 0.7______ sys#1Split 1 Single FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume f t ² ______ # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 75 ft² Attic 15 ft² Default Leakage BEDROOM (Default) c______ 1 1 (Default) c 7/16/2020 4:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 MASTER BED Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM Default(8 lbs/sq.ft. f t ² f t 0.3 BATH Default(8 lbs/sq.ft. f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft. f t ² f t 0.3 PANTRY Default(8 lbs/sq.ft. f t ² f t 0.3 LIVING 7/16/2020 4:28 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT