Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RIAZZI RESIDENCE Builder Name: JWN BUILDERS, LLC. Street: LOT 12 NETTLES ISLAND Permit Office: ST LUCIE COUNTY City, State, Zip: ST LUCIE COUNTY, FL, Permit Number: Owner. Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2089.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggrER=4.2 2089.50 ft' b. N/A R= ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (1512.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=19.0 1512.00 ft2 6. Conditioned floor area above grade (W) 1512 b. N/A R= ft' Conditioned floor area below grade ff) 0 c. N/A R= ft' 11. Duds R ft' 7. Windows (438.7 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 130 a. U-Factor: Dial, U=0.29 166.00 ft' SHGC: SHGC=0.23 b. U-Factor: Obl, U=0.35 146.67 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.20 a. Central Unit 24.0 SEER:16.00 c. U-Factor: Dbl, U=0.32 102.00 W SHGC: SHGC=0.22 13. Heating systems kBlu/hr Efficiency d. U-Factor: other (see details) 24.00 ft' a. Electric Strip Heat 17.0 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.216 14. Hot water systems a. Electric Tankless Cap:1 gallons 8. Floor Types (1512.0 sgft.) Insulation Area EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 779.00 ft' b. Conservation features b. Raised Floor R=19.0 733.00 ft' None c. N/A R= ft° 15. Credits None Glass/Floor Area: 0.290 Total Proposed Modified Loads: 60.79 PASS Total Baseline Loads: 62.12 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this OQTBE,STgT� Code. calculation indicates compliance with the Florida Energy Code. F' un, - ,; PREPARW Y: Before construction is completed DATE: 0- -2C2 this building will be inspected for compliance with Section 553.908 ;4 • ° I hereby certify that this buil ing, as designed is in compliance Florida Statutes. Jj �C with the Florida Energy C CppJ Wr OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/16/2020 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: RIAZZI RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1512 Lot # Owner Name: Total Stories: 2 Block/Subdidsion: # of Units: 1 Worst Case: No PlatBook: Builder Name: JWN BUILDERS, U.C. Rotate Angle: 0 Street: LOT 12 NETTLES ISLA Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: ST LUCIE COUNTY, Family Type: Single-family FL, New/E>dsting: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1512 13608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 POWDER 36 324 No 0 1 Yes Yes Yes 2 FOYER 77 693 No 0 1 Yes Yes Yes 3 W/D STORAGE 57 513 No 0 1 Yes Yes Yes 4 PANTRY 20 180 No 0 1 No Yes Yes 5 KITCHEN 195 1755 Yes 0 1 Yes Yes Yes 6 LIVING DINING 394 3542 No 0 1 Yes Yes Yes 7 BATH 2 60 540 No 0 1 Yes Yes Yes 8 BEDROOM 2 140 1260 No 0 1 1 Yes Yes Yes 9 CLST 2 20 180 No 0 1 Yes Yes Yes 10 M TOILET 21 189 No 0 1 Yes Yes Yes 11 AHU CLST 9 81 No 0 1 No Yes Yes 12 M BATH 50 450 No 0 1 Yes Yes Yes 13 STAIRS UP 64 576 No 0 1 Yes Yes Yes 14 HALLWAY 58 522 No 0 1 No Yes Yes 15 M WIC 56 504 No 0 1 Yes Yes Yes 16 MASTER BEDROO 255 2295 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpel 1 Slab -On -Grade Edge Insulation POWDER 15 f 0 36 f' -- 1 0 0 2 Slab -On -Grade Edge Insulation FOYER lift 0 77 f' -- 1 0 0 6/16/2020 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab -On -Grade Edge Insulation W/D STORAGE 15 ft 0 57 ft2 ___ 1 0 0 4 Slab -On -Grade Edge Insulation PANTRY 1 ft 0 20 ft' ____ 1 0 0 5 Slab -On -Grade Edge Insulation KITCHEN 13 ft 0 195 ft2 __ 1 0 0 6 Slab -On -Grade Edge Insulation LIVING DINING 58.5 ft 0 394 ft2 __ 1 0 0 7 Raised Floor BATH 2 ____ ____ 60 ft2 19 1 0 0 8 Raised Floor BEDROOM 2 ____ ____ 140 ft' 19 1 0 0 9 Raised Floor CLST 2 ____ ____ 20 ft2 19 1 0 0 1ORaised Floor M TOILET ____ ____ 21 ft2 19 1 0 0 11Raised Floor AHU CLST ____ ____ 9 ft2 19 1 0 0 12Raised Floor M BATH ___ _-__ 50 ft2 19 1 0 0 13Raised Floor STAIRS UP ___ -__- 64 ft2 19 1 0 0 14Raised Floor HALLWAY ____ ____ 58 ft2 19 1 0 0 15Raised Floor M W IC ____ ____ 56 112 19 1 0 0 16Raised Floor MASTER BEDRO ____ ____ 255 ft2 19 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emift Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1691 ft' 0 ft' Light N 0.6 No 0.9 No 19 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1512 ft2 N N 6/16/2020 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Ty _ 1 Under Attic (Unvented) POWDER 0 Blown 36 ft2 0.1 Wood - 2 Under Attic(Urvented) FOYER 0 Blown 77 ft2 0.1 Wood _ 3 Under Attic (Unwnted) W/D STORAGE 0 Blown 57 ft2 0.1 Wood _ 4 Under Attic(Unvented) PANTRY 0 Blown 20 ft2 0.1 Wood 5 Under Attic (Unvented) KITCHEN 0 Blown 195 ft2 0.1 Wood 6 Under Attic (Unvented) LIVING DINING 0 Blown 394 ft2 0.1 Wood _ 7 Under Attic (Unvented) BATH 2 0 Blown 60 ft2 0.1 Wood _ 8 Under Attic (Unvented) BEDROOM 2 0 Blown 140 ft2 0.1 Wood 9 Under Attic (Unvented) CLST 2 0 Blown 20 ft2 0.1 Wood _ 10 Under Attic(Unvented) MTOILET 0 Blown 21 ft2 0.1 Wood _ 11 Under Attic (Unvented) AHU CLST 0 Blown 9 ft2 0.1 Wood _ 12 Under Attic (Unvented) M BATH 0 Blown 50 ft2 0.1 Wood _ 13 Under Attic(Unvented) STAIRS UP 0 Blown 64 ft2 0.1 Wood _ 14 Under Attic(Unvented) HALLWAY 0 Blown 58 ft2 0.1 Wood _ 15 Under Attic (Unvented) MWIC 0 Blown 56 ft2 0.1 Wood 16 Under Attic (Unvented) MASTER BEDRO 0 Blown 255 ft2 0.1 Wood A LTJ•TW $ r)mt Adjacent Tn bVell Typo Space Cavity R_\/nl n Width Fr In R Height In Aron Sheathing Framing P-Vnhia Frnptjnn Solar Ahsnr Below r-rnrlp _ 1 E Exterior Concrete Block- PolystyreROWDER 4.2 9 0 9 0 81.0 ft' 0 0 0.6 0 _2 S Exterior Concrete Block- PolystyreROWDER 4.2 4 0 9 0 36.0 ft2 0 0 0.6 0 _ 3 W Exterior Concrete Block - PolystyreBOWDER 4.2 2 0 9 0 18.0 ft2 0 0 0.6 0 4 S Exterior Concrete Block - Polystyren€DYER 4.2 11 0 9 0 99.0 ft2 0 0 0.6 0 _ 5 S Exterior Concrete Black - PolystyMNO STORA 4.2 8 0 9 0 72.0 ft2 0 0 0.6 0 6 W Exterior Concrete Block - PolyslyMNO STORA 4.2 7 0 9 0 63.0 fl' 0 0 0.6 0 7 E Exterior Concrete Block - PolystyreH@TCHEN 4.2 13 0 9 0 117.0 112 0 0 0.6 0 8 N Exterior Concrete Block - Polystyt&VtNG DININ 4.2 12 0 9 0 108.0 ft2 0 0 0.6 0 9 NE Exterior Concrete Block - PolystytdVtNG DININ 4.2 5 10 9 0 52.6 ft2 0 0 0.6 0 10 E Exterior Concrete Block - PolystylAWNG DININ 4.2 15 0 9 0 135.0 ft2 0 0 0.6 0 11 W Exterior Concrete Block - PolystyWVtNG DININ 4.2 19 0 9 0 171.0 ft2 0 0 0.6 0 _12 NW Exterior Concrete Block- Polystyt@tltNG DININ 4.2 6 8 9 0 60.0 f1' 0 0 0.6 0 13 E Exterior Concrete Block - Polystyren®ATH 2 4.2 6 0 9 0 54.0 ft2 0 0 0.6 0 14 S Exterior Concrete Block - Polyslyren®ATH 2 4.2 9 0 9 0 81.0 ft2 0 0 0.6 0 15 W Exterior Concrete Block - Polystyren®ATH 2 4.2 8 0 9 0 72.0 f12 0 0 0.6 0 16 E Exterior Concrete Block - PolyslyfffiOROOM 2 4.2 10 0 9 0 90.0 ft2 0 0 0.6 0 17 S Exterior Concrete Block - PolyslytffiOROOM 2 4.2 12 0 9 0 108.0 ft2 0 0 0.6 0 18 E Exterior Concrete Block - PolystyrenELST 2 4.2 2 0 9 0 18.0 ft2 0 0 0.6 0 19 E Exterior Concrete Block - PolystyrehbTOILET 4.2 3 0 9 0 27.0 ft2 0 0 0.6 0 20 E Exterior Concrete Block - Polystyrerid BATH 4.2 5 0 9 0 45.0 ft2 0 0 0.6 0 21 W Exterior Concrete Block - PolystyraTEAIRS UP 4.2 14 0 9 0 126.0 ft2 0 0 0.6 0 _22 W Exterior Concrete Block - PolystyrenM WIC 4.2 8 0 9 0 72.0 ft2 0 0 0.6 0 23 N Exterior Concrete Block - PolystyddR6TER BE 4.2 11 0 9 0 99.0 ft2 0 0 0.6 0 24 NE Exterior Concrete Block - Polystylt **TER BE 4.2 5 10 9 0 52.5 ft2 0 0 0.6 0 6/16/2020 3:44 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 iq t-UKM K4Ub-ZU1 / INPU I ,UMIVIAKY UHCGKLI5I KhPUKI WALLS It Or.f Adjacent T, Wall Type- Space Cavity Width Height Sheathing Framing Solar Below _ 25 E Exterior Concrete Block - Polysly TER BE 4.2 12 0 9 0 108.0 ft' 0 0 0.6 0 _ 26 W Exterior Concrete Block - PolystyMAffiTER BE 4.2 8 0 9 0 72.0 ft2 0 0 0.6 0 27 NW Exterior Concrete Block - Polysq*MTER BE 4.2 5 10 9 0 52.5 ft2 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 E 1 Vinyl Low-E Double Yes 0.29 0.23 N 8.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 _ 2 S 4 Vinyl Low-E Double Yes 0.35 0.2 N 40.0 ft2 1 ft 0 in 1 ft 4 in None None 3 E 7 Vinyl Low-E Double Yes 0.32 0.22 N 12.0 ft2 1 It 0 in 1 ft 4 in None None _ 4 N 8 Vinyl Low-E Double Yes 0.35 0.2 N 53.3 ft2 1 it 0 in 1 ft 4 in Drapes/blinds Exterior 5 _ 5 NE 9 Vinyl Law-E Double Yes 0.29 0.23 N 24.0 ft' 1 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 _ 6 E 10 Vinyl Low-E Double Yes 0.29 0.23 N 48.0 ft2 1 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 7 W 11 Vinyl Low-E Double Yes 0.32 0.22 N 36.0 ft2 1 it 0 in 1 ft 4 in Drapes/blinds Exterior 5 8 NW 12 Vinyl Low-E Double Yes 0.29 0.23 N 24.0 ft2 1 it in 1 ft4 in Drapes/blinds Exterior 5 _ 9 S 14 Vinyl Low-E Double Yes 0.32 0.22 N 6.0 ft2 1 ft 0 in 1 ft 4 in None None 10 S 17 Vinyl Low-E Double Yes 0.32 0.22. N 4.0 ft2 1 ft 0 in 1 ft 4 in None None 11 S '17 Vinyl Low-E Double Yes 0.32 0.22 N 40.0 ft2 1 it 0 in 1 ft 4 in None None _ 12 E 19 Vinyl Low-E Double Yes 0.32 0.22 N 4.0 ft2 1 ft 0 in 1 ft 4 in None None 13 W 21 Vinyl Low-E Double Yes 0.29 0.23 N 6.0 ft2 1 ft 0 in 1 ft 4 m Drapes/blinds Exterior 5 _ 14 W 21 Vinyl Low-E Double Yes 0.29 0.23 N 8.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 _ 15 N 23 Vinyl Low-E Double Yes 0.35 0.2 N 53.3 ft2 1 It 0 in 1 ft 4 in None None _ 16 NE 24 Vinyl Low-E Double Yes 0.20 0.23 N 24.0 ft2 1 ft 0 in 1 ft 4 in None None _ 17 W 26 Vinyl Low-E Double Yes 0.29 0.23 N 24.0 ft2 1 ft 0 In 1 ft 4 in None None 18 NW 27 Vinyl Low-E Double Yes 0.29 0.2 N 24.0 ft2 1 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1587.1 87.13 163.86 .1918 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Black Ducts 1 Central Unit' Split Single SEER: 16 24 kBtu/hr 720 cm 0.8 1 sys#1 6116/2020 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless EXledor 0.99 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS _ / —Supply— ---Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heal Cool 1 Attic 6 130 ft2 Attic 13 ft2 Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programablef N CFans: XThermostat:x Heating Jan Feb Mar Aprr[eiling f Jun [X� Jul r [X� Aug (XI [ j Sep ] rj L 1 Dec rjX'j Venting (1 Jan I l l L 1 Feb X Mar Apr [ May Jun I Jul I Aug (1 Sep lXl Oct [X Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. Oft' Oft 0.3 POWDER Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 lbs/sq.ft. ft2 ft 0.3 W/D STORAGE Default(8 lbs/sq.ft. ft2 ft 0.3 PANTRY Default(8 lbs/sqft ft2 ft 0.3 KITCHEN Default(8 lbslsq.ft. ft2 ft 0.3 LIVING DINING Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 CLST2 Default(8 lbs/sq.ft. ft2 ft 0.3 M TOILET Default(8 lbs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 lbs/sq.ft. ft2 ft 0.3 M BATH Default(8 lbs/sq.ft. ft2 ft 0.3 STAIRS UP Default(8 lbs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 lbs/sq.ft. ft2 ft 0.3 M WIC Default 81bs/s .ft. ft2 ft 0.3 MASTER BEDROO 6/16/2020 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU CLST 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 24.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1512 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.317 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.216 14. Heating system: Capacity 17.0 c) Area 7c. 438.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 19.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.99 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.2 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be' stalled (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be comple based on inst ed code compliant features. 61Builder Signature: /'� Date: �'-1A Y-dnam Address of New Horfe: LOT 12 NETTLES ISLAND City/FL Zip: ST LUCIE COUNTY, FL 6/16/2020 3:43:04 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FfaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1