HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: RIAZZI RESIDENCE
Builder Name: JWN BUILDERS, LLC.
Street: LOT 12 NETTLES ISLAND
Permit Office: ST LUCIE COUNTY
City, State, Zip: ST LUCIE COUNTY, FL,
Permit Number:
Owner.
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2089.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Polystyrene Bead AggrER=4.2 2089.50 ft'
b. N/A
R= ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 2
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (1512.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=19.0 1512.00 ft2
6. Conditioned floor area above grade (W) 1512
b. N/A
R= ft'
Conditioned floor area below grade ff) 0
c. N/A
R= ft'
11. Duds
R ft'
7. Windows (438.7 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AHU CLST
6 130
a. U-Factor: Dial, U=0.29 166.00 ft'
SHGC: SHGC=0.23
b. U-Factor: Obl, U=0.35 146.67 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.20
a. Central Unit
24.0 SEER:16.00
c. U-Factor: Dbl, U=0.32 102.00 W
SHGC: SHGC=0.22
13. Heating systems
kBlu/hr Efficiency
d. U-Factor: other (see details) 24.00 ft'
a. Electric Strip Heat
17.0 COP:1.00
SHGC: other (see details)
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.216
14. Hot water systems
a. Electric Tankless
Cap:1 gallons
8. Floor Types (1512.0 sgft.) Insulation Area
EF: 0.990
a. Slab -On -Grade Edge Insulation R=0.0 779.00 ft'
b. Conservation features
b. Raised Floor R=19.0 733.00 ft'
None
c. N/A R= ft°
15. Credits
None
Glass/Floor Area: 0.290 Total Proposed Modified Loads: 60.79
PASS
Total Baseline Loads: 62.12
1 hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
OQTBE,STgT�
Code.
calculation indicates compliance
with the Florida Energy Code.
F' un, - ,;
PREPARW Y:
Before construction is completed
DATE: 0- -2C2
this building will be inspected for
compliance with Section 553.908
;4
• °
I hereby certify that this buil ing, as designed is in compliance
Florida Statutes.
Jj �C
with the Florida Energy C
CppJ
Wr
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/16/2020 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
RIAZZI RESIDENCE
Bedrooms:
2
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1512
Lot #
Owner Name:
Total Stories:
2
Block/Subdidsion:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
JWN BUILDERS, U.C.
Rotate Angle:
0
Street:
LOT 12 NETTLES ISLA
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State,
Zip:
ST LUCIE COUNTY,
Family Type:
Single-family
FL,
New/E>dsting:
New (From Plans)
Comment:
CLIMATE
_ /
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
1512
13608
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
POWDER
36
324
No
0
1
Yes
Yes
Yes
2
FOYER
77
693
No
0
1
Yes
Yes
Yes
3
W/D STORAGE
57
513
No
0
1
Yes
Yes
Yes
4
PANTRY
20
180
No
0
1
No
Yes
Yes
5
KITCHEN
195
1755
Yes
0
1
Yes
Yes
Yes
6
LIVING DINING
394
3542
No
0
1
Yes
Yes
Yes
7
BATH 2
60
540
No
0
1
Yes
Yes
Yes
8
BEDROOM 2
140
1260
No
0
1
1
Yes
Yes
Yes
9
CLST 2
20
180
No
0
1
Yes
Yes
Yes
10
M TOILET
21
189
No
0
1
Yes
Yes
Yes
11
AHU CLST
9
81
No
0
1
No
Yes
Yes
12
M BATH
50
450
No
0
1
Yes
Yes
Yes
13
STAIRS UP
64
576
No
0
1
Yes
Yes
Yes
14
HALLWAY
58
522
No
0
1
No
Yes
Yes
15
M WIC
56
504
No
0
1
Yes
Yes
Yes
16
MASTER BEDROO
255
2295
No
0
1
1
Yes
Yes
Yes
FLOORS
#
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpel
1 Slab -On -Grade Edge Insulation POWDER 15 f
0
36 f'
--
1 0
0
2 Slab -On -Grade Edge Insulation FOYER lift
0
77 f'
--
1 0
0
6/16/2020 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
3 Slab -On -Grade Edge Insulation
W/D STORAGE 15 ft
0
57 ft2
___
1
0
0
4 Slab -On -Grade Edge Insulation
PANTRY 1 ft
0
20 ft'
____
1
0
0
5 Slab -On -Grade Edge Insulation
KITCHEN 13 ft
0
195 ft2
__
1
0
0
6 Slab -On -Grade Edge Insulation
LIVING DINING 58.5 ft
0
394 ft2
__
1
0
0
7 Raised Floor
BATH 2 ____
____
60 ft2
19
1
0
0
8 Raised Floor
BEDROOM 2 ____
____
140 ft'
19
1
0
0
9 Raised Floor
CLST 2 ____
____
20 ft2
19
1
0
0
1ORaised Floor
M TOILET ____
____
21 ft2
19
1
0
0
11Raised Floor
AHU CLST ____
____
9 ft2
19
1
0
0
12Raised Floor
M BATH ___
_-__
50 ft2
19
1
0
0
13Raised Floor
STAIRS UP ___
-__-
64 ft2
19
1
0
0
14Raised Floor
HALLWAY ____
____
58 ft2
19
1
0
0
15Raised Floor
M W IC ____
____
56 112
19
1
0
0
16Raised Floor
MASTER BEDRO ____
____
255 ft2
19
1
0
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emift
Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested
Insul.
(deg)
1 Hip
Metal 1691 ft'
0 ft'
Light
N
0.6
No 0.9
No
19
26.6
ATTIC
/
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Unvented
0
1512 ft2
N
N
6/16/2020 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Ty
_ 1
Under Attic (Unvented)
POWDER
0
Blown
36 ft2
0.1
Wood
-
2
Under Attic(Urvented)
FOYER
0
Blown
77 ft2
0.1
Wood
_ 3
Under Attic (Unwnted)
W/D STORAGE
0
Blown
57 ft2
0.1
Wood
_ 4
Under Attic(Unvented)
PANTRY
0
Blown
20 ft2
0.1
Wood
5
Under Attic (Unvented)
KITCHEN
0
Blown
195 ft2
0.1
Wood
6
Under Attic (Unvented)
LIVING DINING
0
Blown
394 ft2
0.1
Wood
_ 7
Under Attic (Unvented)
BATH 2
0
Blown
60 ft2
0.1
Wood
_ 8
Under Attic (Unvented)
BEDROOM 2
0
Blown
140 ft2
0.1
Wood
9
Under Attic (Unvented)
CLST 2
0
Blown
20 ft2
0.1
Wood
_ 10
Under Attic(Unvented)
MTOILET
0
Blown
21 ft2
0.1
Wood
_ 11
Under Attic (Unvented)
AHU CLST
0
Blown
9 ft2
0.1
Wood
_ 12
Under Attic (Unvented)
M BATH
0
Blown
50 ft2
0.1
Wood
_ 13
Under Attic(Unvented)
STAIRS UP
0
Blown
64 ft2
0.1
Wood
_ 14
Under Attic(Unvented)
HALLWAY
0
Blown
58 ft2
0.1
Wood
_ 15
Under Attic (Unvented)
MWIC
0
Blown
56 ft2
0.1
Wood
16
Under Attic (Unvented)
MASTER BEDRO
0
Blown
255 ft2
0.1
Wood
A
LTJ•TW
$
r)mt
Adjacent
Tn
bVell Typo Space
Cavity
R_\/nl n
Width
Fr In
R
Height
In
Aron
Sheathing Framing
P-Vnhia Frnptjnn
Solar
Ahsnr
Below
r-rnrlp
_ 1
E
Exterior
Concrete Block- PolystyreROWDER
4.2
9
0
9
0
81.0 ft'
0
0
0.6
0
_2
S
Exterior
Concrete Block- PolystyreROWDER
4.2
4
0
9
0
36.0 ft2
0
0
0.6
0
_ 3
W
Exterior
Concrete Block - PolystyreBOWDER
4.2
2
0
9
0
18.0 ft2
0
0
0.6
0
4
S
Exterior
Concrete Block - Polystyren€DYER
4.2
11
0
9
0
99.0 ft2
0
0
0.6
0
_ 5
S
Exterior
Concrete Black - PolystyMNO STORA
4.2
8
0
9
0
72.0 ft2
0
0
0.6
0
6
W
Exterior
Concrete Block - PolyslyMNO STORA
4.2
7
0
9
0
63.0 fl'
0
0
0.6
0
7
E
Exterior
Concrete Block - PolystyreH@TCHEN
4.2
13
0
9
0
117.0 112
0
0
0.6
0
8
N
Exterior
Concrete Block - Polystyt&VtNG DININ
4.2
12
0
9
0
108.0 ft2
0
0
0.6
0
9
NE
Exterior
Concrete Block - PolystytdVtNG DININ
4.2
5
10
9
0
52.6 ft2
0
0
0.6
0
10
E
Exterior
Concrete Block - PolystylAWNG DININ
4.2
15
0
9
0
135.0 ft2
0
0
0.6
0
11
W
Exterior
Concrete Block - PolystyWVtNG DININ
4.2
19
0
9
0
171.0 ft2
0
0
0.6
0
_12
NW
Exterior
Concrete Block- Polystyt@tltNG DININ
4.2
6
8
9
0
60.0 f1'
0
0
0.6
0
13
E
Exterior
Concrete Block - Polystyren®ATH 2
4.2
6
0
9
0
54.0 ft2
0
0
0.6
0
14
S
Exterior
Concrete Block - Polyslyren®ATH 2
4.2
9
0
9
0
81.0 ft2
0
0
0.6
0
15
W
Exterior
Concrete Block - Polystyren®ATH 2
4.2
8
0
9
0
72.0 f12
0
0
0.6
0
16
E
Exterior
Concrete Block - PolyslyfffiOROOM 2
4.2
10
0
9
0
90.0 ft2
0
0
0.6
0
17
S
Exterior
Concrete Block - PolyslytffiOROOM 2
4.2
12
0
9
0
108.0 ft2
0
0
0.6
0
18
E
Exterior
Concrete Block - PolystyrenELST 2
4.2
2
0
9
0
18.0 ft2
0
0
0.6
0
19
E
Exterior
Concrete Block - PolystyrehbTOILET
4.2
3
0
9
0
27.0 ft2
0
0
0.6
0
20
E
Exterior
Concrete Block - Polystyrerid BATH
4.2
5
0
9
0
45.0 ft2
0
0
0.6
0
21
W
Exterior
Concrete Block - PolystyraTEAIRS UP
4.2
14
0
9
0
126.0 ft2
0
0
0.6
0
_22
W
Exterior
Concrete Block - PolystyrenM WIC
4.2
8
0
9
0
72.0 ft2
0
0
0.6
0
23
N
Exterior
Concrete Block - PolystyddR6TER BE
4.2
11
0
9
0
99.0 ft2
0
0
0.6
0
24
NE
Exterior
Concrete Block - Polystylt **TER BE
4.2
5
10
9
0
52.5 ft2
0
0
0.6
0
6/16/2020 3:44 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
iq
t-UKM K4Ub-ZU1 /
INPU I ,UMIVIAKY UHCGKLI5I KhPUKI
WALLS
It Or.f
Adjacent
T, Wall
Type-
Space Cavity
Width
Height
Sheathing Framing Solar
Below
_ 25 E
Exterior
Concrete Block - Polysly TER BE 4.2
12 0 9
0
108.0 ft'
0
0 0.6
0
_ 26 W
Exterior
Concrete Block - PolystyMAffiTER BE 4.2
8 0 9
0
72.0 ft2
0
0 0.6
0
27 NW
Exterior
Concrete Block - Polysq*MTER BE 4.2
5 10 9
0
52.5 ft2
0
0 0.6
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Omt ID
Frame
Panes
NFRC
U-Factor
SHGC Imp
Area
Depth
Separation
Int Shade
Screening
_ 1
E 1
Vinyl
Low-E Double
Yes
0.29
0.23 N
8.0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
_ 2
S 4
Vinyl
Low-E Double
Yes
0.35
0.2 N
40.0 ft2
1 ft 0 in
1 ft 4 in
None
None
3
E 7
Vinyl
Low-E Double
Yes
0.32
0.22 N
12.0 ft2
1 It 0 in
1 ft 4 in
None
None
_ 4
N 8
Vinyl
Low-E Double
Yes
0.35
0.2 N
53.3 ft2
1 it 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
_ 5
NE 9
Vinyl
Law-E Double
Yes
0.29
0.23 N
24.0 ft'
1 It 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
_ 6
E 10
Vinyl
Low-E Double
Yes
0.29
0.23 N
48.0 ft2
1 It 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
7
W 11
Vinyl
Low-E Double
Yes
0.32
0.22 N
36.0 ft2
1 it 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
8
NW 12
Vinyl
Low-E Double
Yes
0.29
0.23 N
24.0 ft2
1 it in
1 ft4 in
Drapes/blinds
Exterior 5
_ 9
S 14
Vinyl
Low-E Double
Yes
0.32
0.22 N
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
10
S 17
Vinyl
Low-E Double
Yes
0.32
0.22. N
4.0 ft2
1 ft 0 in
1 ft 4 in
None
None
11
S '17
Vinyl
Low-E Double
Yes
0.32
0.22 N
40.0 ft2
1 it 0 in
1 ft 4 in
None
None
_ 12
E 19
Vinyl
Low-E Double
Yes
0.32
0.22 N
4.0 ft2
1 ft 0 in
1 ft 4 in
None
None
13
W 21
Vinyl
Low-E Double
Yes
0.29
0.23 N
6.0 ft2
1 ft 0 in
1 ft 4 m
Drapes/blinds
Exterior 5
_ 14
W 21
Vinyl
Low-E Double
Yes
0.29
0.23 N
8.0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
_ 15
N 23
Vinyl
Low-E Double
Yes
0.35
0.2 N
53.3 ft2
1 It 0 in
1 ft 4 in
None
None
_ 16
NE 24
Vinyl
Low-E Double
Yes
0.20
0.23 N
24.0 ft2
1 ft 0 in
1 ft 4 in
None
None
_ 17
W 26
Vinyl
Low-E Double
Yes
0.29
0.23 N
24.0 ft2
1 ft 0 In
1 ft 4 in
None
None
18
NW 27
Vinyl
Low-E Double
Yes
0.29
0.2 N
24.0 ft2
1 ft 0 in
1 ft 4 in
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50
ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.0004
1587.1
87.13 163.86
.1918
7
HEATING SYSTEM
#
System Type
Subtype
Speed
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA
17 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype
Efficiency
Capacity Air Flow
SHR Black
Ducts
1
Central Unit'
Split
Single
SEER: 16
24 kBtu/hr 720 cm
0.8 1
sys#1
6116/2020 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
Tankless
EXledor
0.99
1 gal
55.1 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
_ /
—Supply—
---Return—
Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON
RLF
Heal Cool
1 Attic
6 130 ft2
Attic
13 ft2
Default Leakage
AHU CLST (Default) c(Default) c
1 1
TEMPERATURES
Programablef
N
CFans:
XThermostat:x
Heating Jan
Feb
Mar
Aprr[eiling
f
Jun [X� Jul
r
[X� Aug
(XI
[ j Sep
] rj
L 1
Dec
rjX'j
Venting (1 Jan I
l l L
1 Feb
X Mar
Apr
[ May
Jun I Jul
I Aug
(1 Sep
lXl Oct [X
Nov
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8
9 10
11
12
Cooling (WD)
AM
78
78 78
78
78 78
78
78
80 80
80
80
PM
80
80 80
80
78 78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78 78
78
78 78
78
78
80 80
80
80
PM
80
80 80
80
78 78
78
78
78 78
78
78
Heating (WD)
AM
65
65 65
65
65 65
65
68
68 68
68
68
PM
68
68 68
68
68 68
68
68
68 68
68
68
Heating (WEH)
AM
65
65 65
65
65 65
65
68
68 68
68
68
PM
68
68 68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
Oft'
Oft
0.3
POWDER
Default(8 lbs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 lbs/sq.ft.
ft2
ft
0.3
W/D STORAGE
Default(8 lbs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 lbs/sqft
ft2
ft
0.3
KITCHEN
Default(8 lbslsq.ft.
ft2
ft
0.3
LIVING DINING
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
CLST2
Default(8 lbs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 lbs/sq.ft.
ft2
ft
0.3
AHU CLST
Default(8 lbs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
STAIRS UP
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 lbs/sq.ft.
ft2
ft
0.3
M WIC
Default 81bs/s .ft.
ft2
ft
0.3
MASTER BEDROO
6/16/2020 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location AHU CLST
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
24.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
1512
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.317
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.216
14. Heating system: Capacity
17.0
c) Area
7c.
438.7
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
19.0
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.99
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.2
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061.
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida
Building Code, Energy Conservation, through the above energy
saving features which will be' stalled (or exceeded)
in this home before final inspection. Otherwise, a new EPL
display card will be comple based on inst
ed code compliant features.
61Builder Signature:
/'�
Date: �'-1A Y-dnam
Address of New Horfe: LOT 12 NETTLES ISLAND City/FL Zip: ST LUCIE COUNTY, FL
6/16/2020 3:43:04 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FfaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1