PERMIT DRAWING
PROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
CAD I.D.:
SHEET NUMBER:
SHEET TITLE:
PROJECT:
KNOW WHAT'S BELOW
ALWAYS CALL 811
BEFORE YOU DIG
It's fast. It's free. It's the law.
www.callsunshine.com
SCOTT
BARBER
DESIGNS
P.A.
1"=20'
0 2051020
SCALE:
AS
L-3
LI_7-23-20.DWG
NOTED
7/23/20
CR
SJB
18-010.12
LANDSCAPE ARCHITECTURE & PLANNING
IRRIGATION
PLAN
1551 WYNDCLIFF DRIVE
WELLINGTON, FL 33414
(561) 309-7263
LC-26000593
REVISIONS
REV DATE COMMENT BY
FLO R I D A
STATE
OF
LA-0001660
R
E
G
I S T E R E D L A N D SCAPE A
R
C
H
I
T
E
C
T
S C O T T J . BA
R
B
E
R
FOR
LOCATION OF SITE
POPEYES
4946 S. 25TH ST.
FORT PIERCE, FL 34981
ST. LUCIE COUNTY
WEST MIDWAY RD
& S. 25TH. ST.
(2 S-BU, 1 ISLAND)
MATCH LINE 'A'
MATCH LINE 'A'
WEST BUFFER EXTENSION
PIPE SIZING CHART
SIZE PIPE SO NOT TO EXCEED
A MAXIMUM FLOW OF 5 FEET
PER SECOND (fps)
PIPE SIZE GUIDELINE:
3/4" (0-9 GPM)
1" (10-16 GPM)
1 1/4" (16-25 GPM)
1 1/2" (25-35 GPM)
2" (35-52 GPM)
SYMBOL MANUFACTURER/MODEL ARC PSI GPM RADIUS
Rain Bird 1812-SAM 15 Strip Series SST 25 1.11 4'x30'
Rain Bird 1812-SAM 8 Series MPR 180 25 0.47 7'
Rain Bird 1806-SAM 1404 Flood Bubbler 25 1.0 3'
Rain Bird PEB-PRS-D Plastic Industrial Valves
Globe Configuration, With Pressure Regulating Module
(Mount in pump enclosure)
Rain Bird ESP-ME Controller (Outdoor)
Rain Bird WR2-RC 1 Wireless Rain Sensor Combo.
(Mount on dumpster wall, coordinate with Owner)
Irrigation Lateral Line: PVC Class 200 SDR 21
PVC Class 200 irrigation pipe. Only lateral transition pipe
sizes 1" and above are indicated on the plan, with all others
being 3/4" in size.
Irrigation Mainline: PVC Schedule 40 ( 2" )
Pipe Sleeve: PVC Schedule 40
Typical pipe sleeve for irrigation pipe. Pipe sleeve size shall
allow for irrigation piping and their related couplings to
easily slide through sleeving material. Extend sleeves 36
inches beyond edges of paving or construction.
Valve Number
Valve Flow
Valve Size
Valve Callout
#
#
#"
IRRIGATION SCHEDULE
#"
#"*
Pipe Sleeve
Wire Sleeve
R
C
Rain Bird 1812-SAM 15 Series MPR 180 25 1.65 14'
P Well & Pump Station (See Detail Sheet)
Rain Bird 1812-SAM 12 Series MPR 180 25 1.20 11'
Rain Bird 1812-SAM 12 Series MPR 90 25 0.60 11'
Rain Bird 1812-SAM 8 Series MPR 180 25 0.47 7'
Rain Bird 1812-SAM 15 Series MPR 90 25 .93 14'
Rain Bird 1812-SAM 15 Strip Series LCS 25 0.45 4'x15'
Rain Bird 1812-SAM 15 Strip Series RCS 25 0.45 4'x15'
Rain Bird 1812-SAM 15 Series MPR VAN 25 - -
TESTING:
Upon completion of main line and prior to backfill, pressure test the entire
water-filled main line (with valves and backflow closed) at (150) pounds per
square inch for 30 minutes using a pump and pressure gauge. Repair any
systems which exceed (5) pounds per square inch drop in 30 minutes of
testing, until the standard can be achieved and verified.
SYSTEM MAINTENANCE:
Every month the irrigation system shall be inspected to ensure that the
various components and functions of the irrigation system are functioning
properly. The scope of work includes, but is not limited to, the point of
connection, piping system, electrical system, sprinkler heads, nozzles, drip
components, valves, controller and weather/soil sensors.
TESTING & MAINTENANCE
Before scheduling run times, the site should be “walked” and planted areas
inspected to observe plant stress and health. Soil moisture levels should be
inspected throughout planted areas, and appropriate adjustments made to
the irrigation schedule. Each irrigation session should be scheduled to
encourage deep roots through deep watering and minimal runoff. This can
be achieved through use of multiple short repeat cycles when necessary,
especially on slopes and sites with compacted soils. Watering times should
deliver enough water to soak the ground to a depth of 12 inches. Run times
should be adjusted accordingly to soil type and plant water requirements.
Less water is needed to soak a sandy soil compared to a clay soil. Soils
should be allowed to dry to a 50% moisture depletion level between
irrigations to avoid root rot and allow adequate air to be present in the soil.
Run times shall be adjusted seasonally.
SYSTEM SCHEDULING
GENERAL IRRIGATION NOTES
PROVIDE AN AUTOMATIC UNDERGROUND IRRIGATION SYSTEM PROVIDING
100% COVERAGE WITH 50% OVERLAP. THE SYSTEM WILL BE DESIGNED IN
HYDRO-ZONES BASED ON PLANTING ARRANGEMENT. AND DISTRIBUTION
WILL BE THROUGH A COMBINATION OF CONVENTIONAL POP-UP SPRAY
HEADS AND FLOOD BUBBLERS ON TREES. A RAIN SENSOR WILL BE PROVIDED
TO AID IN WATER CONSERVATION.
THE BASIS IF DESIGN IS A 4" WELL AND CENTRIFUGAL PUMP SOURCE
PROVIDING 50 PSI @ 35 GPM.
1.
3.THE MAIN LINE CONNECTION IS SCHEMATIC ONLY. THE CONTRACTOR SHALL
VERIFY AND ADJUST THE TAP AND BACKFLOW PREVENTER LOCATION, AND
MAIN LINE APPROPRIATELY WITHIN THE LANDSCAPE AREAS.
2.
THE LOCATION OF THE CONTROLLER AND PUMP STATION WILL BE
COORDINATED WITH THE OWNER. THE ELECTRICAL POWER SOURCES WILL BE
PROVIDED BY OTHERS. THE ELECTRICAL CONTRACTOR WILL MAKE THE FINAL
CONNECTION FROM THE ELECTRICAL SOURCE TO THE CONTROLLER.
4.
C
R
7
21
1.5"
LAWN
SPRAY
P
4 EXISTING TREES TO
REMAIN TYP. DO NOT
DISTURB ROOT SYSTEMS
TYPE SIZE GPM PRECIP (IN/HR) RUN TIME (Min.)
NOTE:
DAILY OPERATION FOR 60 DAY ESTABLISHMENT PERIOD, AFTER, TWO DAYS A
WEEK DURING DAYLIGHT SAVINGS TIME, AND ONE DAY A WEEK DURING
EASTERN STANDARD TIME.
SYSTEM SCHEDULE
No.
(3/4 INCH PER DAY)
ZONE 2 TREE BUBBLERS 1.5" 22 .85 15
ZONE 4 SHRUB SPRAY 1.5" 26 .85 26
ZONE 7 LAWN SPRAY 1.5" 21 .85 52
6"
6"
6"
6"1"*
MONUMENT SIGN
Rain Bird 1812-SAM 12 Series MPR 180 25 0.73 9'
8
15
1.5"
SHRUB
SPRAY
1
15
1.5"
SHRUB
SPRAY
EXISTING TREE TO
REMAIN TYP. DO NOT
DISTURB ROOT SYSTEMS.
NO IRRIGATION IN
THE ISLAND
WELL AND PUMP
STATION, COORDINATE
ELECTRICAL CONNECTION
6
29
1.5"
LAWN
SPRAY
5
18
1.5"
TREE
BUBBLER
4
26
1.5"
SHRUB
SPRAY
3
24
1.5"
SHRUB
SPRAY
4"
4"
4"
ZONE 5 TREE BUBBLERS 1.5" 16 1 Gal/Min. 15
ZONE 3 SHRUB SPRAY 1.5" 24 .85 26
ZONE 6 LAWN SPRAY 1.5" 29 .85 52
ZONE 8 SHRUB SPRAY 1.5" 15 .85 26
ZONE 1 SHRUB SPRAY 1.5" 15 .85 26
4"
4"
4"
9
31
1.5"
LAWN
SPRAY
2
22
1.5"
TREE
BUBBLERS
ZONE 9 LAWN SPRAY 1.5" 31 .85 52
4"
CONTROLLER & RAIN
SENSOR. COORDINATE
WITH OWNER AND
ELECTRICAL SERVICE