Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Busines essional Regulation - Residential Performance Method RECEI�/r. Project Name: CIMINO RESIDENCE A� �9 Builder ame: Street: 6702 DONLON ROAD 9 LLUCMle Jf O Permit ffice: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit umber. Owner: VINCENT CIMINO County, PermlttHiii�i lion: ST LUCIE COUTY Design Location: FL, Fort Pierce St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1436.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1260.70 ft- b. Frame - Wood, Adjacent R=11.0 176.00 fF 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. NIA R= ft' 10. Ceiling Types (1439.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1439.00 ftz 6. Conditioned Floor area above grade (ft') 1439 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft= 11. Ducts R fP 7. Windows(151.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 140 a. U-Factor. SgI, U=0.65 91.00 ft' SHGC: SHGC=0.25 b. U-Factor. SgI, U=0.65 60.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 28.0 SEER:16.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft' a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 4.512 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems a. Electric Cap: 50 gallons 8. FloorTypes (1439.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1439.00 ft- b. Conservation features b. NIA R= ft' None c. NIA R= ft' 15. Credits None Glass/Floor Area: 0.105 Total Proposed Modified Loads: 47.66 PASS Total Baseline Loads: 50.61 1 hereby certify that the plans and specifications covered by Review of the plans and 'i1tE STgT this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance y m, °%' ` with the Florida Energy Code. PREPARED BY: DATE: 3- - 0 Before construction is completed this building will be inspected for compliance with Section 553.908 z i I hereby certify that this building, as dese , is in compliance Florida Statutes. !t yS COD with the Florida Ener Co e. WE itt0 OWNER/AGENT BUILDING OFFICIAL: DATE: "::2- -ag=Z11 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. -(Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 327/20201:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: CIMINO RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1439 Lot # Owner Name: VINCENT CIMINO Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook Builder Name: Rotate Angle: 0 Street: 6702 DONLON ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St. Lucie Jurisdiction: ST LUCIE COUTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1439 11843.8 ]Heated SPACES Number Name Area Volume IGtchen Occupants Bedrooms Infil ID Finished Cooled 1 BEDROOM 3 131 1048 No 0 1 1 Yes Yes Yes 2 CLST 3 18 144 No 0 1 Yes Yes Yes 3 BATH 2 54 432 No 0 1 Yes Yes Yes 4 CLST 2 18 144 No 0 1 Yes Yes Yes 5 BEDROOM 2 132 1056 No 0 1 1 Yes Yes Yes 6 HALL 30 240 No 0 1 No Yes Yes 7 DINING 96 768 No 0 1 Yes Yes Yes 8 FOYER 24 192 No 0 1 Yes Yes Yes 9 KITCHEN/NOOK 265 2120 Yes 0 1 Yes Yes Yes 10 GREAT ROOM 266 2314.2 No 0 1 Yes Yes Yes 11 LAUNDRY 36 288 No 0 1 Yes Yes Yes 12 M BATH 98 784 No 0 1 Yes Yes Yes 13 M TOILET 30 240 No 0 1 Yes Yes Yes 14 M WIC 33 264 No 0 1 No Yes Yes 15 MASTER BEDROO 208 1809.6 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 3 23 ft 0 131 ft' __ 1 0 0 2SIab-On-Grade Edge Insulation CLST 3 2 ft 0 18 ft' — 1 0 0 3SIab-On-Grade Edge Insulation BATH 2 6 ft 0 54 ft- — 1 0 0 32720201:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 4Slab-OnGrade Edge Insulation CLST 2 2 It 0 18 ft' _ 1 0 0 5SIab-OnGrade Edge Insulation BEDROOM 2 28 ft 0 132 ft2 — 1 0 0 6SIab-OnGrade Edge Insulation HALL 1 ft 0 30 ft2 — 1 0 0 7SIab-OnGrade Edge Insulation DINING 16 ft 0 96 ft' — 1 0 0 8SlabGrrGrade Edge Insulation FOYER E ft 0 24 ft2 _ 1 0 0 98Iab-OnGrade Edge Insulation KITCHEN/NOOK 13 ft 0 265 ft2 _ 1 0 0 1ISIab-OnGrade Edge Insulation GREAT ROOM 14 ft 0 266 ft2 _- 1 0 0 11SIab-On-Grade Edge Insulation LAUNDRY 4ft 0 36 ft' — 1 0 0 12SIab-OnGrade Edge Insulation M BATH 7 ft 0 98 ft2 — 1 0 0 133Iab-OnGrade Edge Insulation M TOILET 4ft 0 30 ft2 — 1 0 0 14SIab-OnGrade Edge Insulation M WIC 1 ft 0 33 ft2 — 1 0 0 15SIab-On-Grade Edge Insulation MASTER BEDRO 29 ft 0 208 ft2 — 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1559 ft2 Oft' Medium N 0.6 No 0.9 No 0 22.6 ATTIC / v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1439 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) BEDROOM 3 30 Blown 131 ft' 0.1 Wood 2 Under Attic (Vented) CLST 3 30 Blown 18 ft' 0.1 Wood 3 Under Attic (Vented) BATH 2 30 Blown 54 ft' 0.1 Wood 4 Under Attic (Vented) CLST2 30 Blown 18 R2 0.1 Wood _ 5 Under Attic(Vented) BEDROOM 30 Blown 132 ft2 0.1 Wood 6 Under Attic (Vented) HALL 30 Blown 30 ft' 0.1 Wood _ 7 Under Attic (Vented) DINING 30 Blown 96 R' 0.1 Wood 8 Under Attic (Vented) FOYER 30 Blown 24 ft' 0.1 Wood _ 9 Under Attie (Vented) KITCHEN/NOOK 30 Blown 265 fN 0.1 Wood 10 Under Attic (Vented) GREAT ROOM 30 Blown 266 ft2 0.1 Wood • 11 Under Attie (Vented) LAUNDRY 30 Blown 36ft2 0.1 Wood 12 Under Attic (Vented) M BATH 30 Blown 98 ft' 0.1 Wood 13 Under Attic (Vented) MTOILET 30 Blown 30 ft2 0.1 Wood 14 Under Attic (Vented) M WIC 30 Blown 33 ft' 0.1 Wood 15 Under Attic (Vented) MASTER BEDRO 30 Blown 208 ft2 0.1 Wood 327=201:11 PM EnergyGaugeOl USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceArea _ 1 N Exterior Concrete Block- Ext InsLEEDROOM 3 4.1 12 0 8 0 96.0 ft' 0 0 0.6 0 -2 W Exterior Concrete Block - Ext InstSEDROOM 3 4.1 11 0 8 0 88.0 ft' 0 0 0.6 0 3 W Exterior Concrete Block- Ext Insul CLST 3 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 -4 W Exterior Concrete Block- Ext Insul BATH 2 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block- Ext Insul CLST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 6 E Exterior Concrete Block- Ext lnsLBEDROOM 2 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 -7 S Exterior Concrete Block- Ext Insd3EDROOM 2 4.1 12 0 8 0 96.0 f- 0 0 0.6 0 _ 8 W Exterior Concrete Block- Ext InstSEDROOM 2 4.1 11 0 8 0 88.0 ft' 0 0 0.6 0 9 E Exterior Concrete Block-Ext Insul DINING 4.1 4 0 8 0 32.0 ft2 0 0 0.6 0 _ 10 S Exterior Concrete Block- Ext Insul DINING 4.1 12 0 8 0 96.0 ft' 0 0 0.6 0 _ 11 S Exterior Concrete Block- Ext Insul FOYER 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 _ 12 N Exterior Concrete Block- Ext Insl9TCHEN/NO 4.1 13 0 8 0 104.0 ft- 0 0 0.6 0 13 N Exterior Concrete Block- Ext InsGREAT ROO 4.1 14 0 8 8 121.3 112 0 0 0.6 0 _ 14 W Exterior Concrete Block- Ext InsuILAUNDRY 4.1 4 0 8 0 32.0 it' 0 0 0.6 0 15 S Garage Frame - Wood LAUNDRY 11 6 0 8 0 48.0 ft2 0 0.1 0.6 0 _ 16 E Exterior Concrete Block- Ext Insul M BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.6 0 17 S Garage Frame - Wood M BATH 11 8 0 8 0 64.0 ft2 0 0.1 0.6 0 _ 18 E Exterior Concrete Block - Ext Insul M TOILET 4.1 4 0 8 0 32.0 ft2 0 0 0.6 0 _ 19 S Garage Frame - Wood M TOILET 11 8 0 8 0 64.0 ft2 0 0.1 0.6 0 20 N Exterior Concrete Block- Ext InsdMASTER BE 4.1 13 0 8 8 112.7 112 0 0 0.6 0 21 E Exterior Concrete Block- Ext InsdMASTER BE 4.1 16 0 8 8 138.7 ft2 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 2 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1ft4In tft4in None None _ 2 W 4 Metal Low-E Single Yes 0.65 0.25 N 3.0 112 1 ft 4 in 1 ft4 in None None _ 3 S 7 Metal Low-E Single Yes 0.65 025 N 15.0 ft2 1 H 4 in 1 k 4 in None None _ 4 S 10 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 It 4 in 1 ft 4 in None None 5 S 11 Metal Low-E Single Yes 0.65 0.3 N 20.0 ft' 5 ft 4 in 1 ft 4 in None None 6 N 12 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 It 4 in 1 ft 4 in None None 7 N 13 Metal Low-E Single Yes 0.65 0.3 N 40.0 ft2 11 It 4 in 1 ft 4 in None None 8 E 18 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 1 ft 4 in 1 ft 4 in None None 9 N 20 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 4 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 484 ft' 484 ft2 22 ft 8 ft 11 32720201:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000366 1381.8 75.86 142.66 .1283 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 28 kBtu/hr 840 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPrd Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS —Supply— V # Location R-Value Area —Return— Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC# Heat Cool 1 Attic 6 140 ft' Attic 14 ft' Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable[Cooling(XT��hermostat(: N rD0' VentiDec ng [ ] Jan j ] Feb [X] Mar Apr [r I Cfreiling Fans: 4May r[X]� 4 4 [ Nov [X] Apr [ May [ Jun [ ] Jul [ Aug [ Sep Oct [X] Nov r�X'I [ ] Dec 327/20201:11 PM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 s0 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (IND) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Defauit(8 lbs/sq.ft. 0 ft' 0 It 0.3 BEDROOM 3 Defauit(8 lbs/sq.ft. ft' ft 0.3 CLST 3 Default@ lbs/sq.ft. ft- ft 0.3 BATH 2 Default(8 lbs/sq.ft. ft' it 0.3 CLST 2 Defauft(8lbs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' It 0.3 HALL Defauit(8 lbs/sq.ft. ft' ft 0.3 DINING Defauit(8lbs/sq.ft. ft. It 0.3 FOYER Default(8 lbs/sq.ft. ft' it 0.3 KITCHEN/NOOK Defauit(8lbs/sq.ft. ft' It 0.3 GREAT ROOM Defauit(S lbs/sq.ft. ft2 ft 0.3 LAUNDRY Defauit(6lbs/sq.ft. ft' ft 0.3 M BATH Defautt(8 lbs/sq.ft. ft' it 0.3 M TOILET Defauit(B lbs/sq.ft. ft. it 0.3 M W IC Defauit 8lbs/s .ft. ft- It 0.3 MASTER BEDROO 3f 20201:11 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CIMINO RESIDENCE Builder Name: Street: 6702 DONLON ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: `1 U Owner. VINCENT CIMINO Jurisdiction: ST LUCIE GOUTY w x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable Insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Gelling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rimjoists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation Installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, Insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts In narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall, thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing In exterior walls, or Insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier Installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. Insulated. Electrical/phone box on The air barrier shall be Installed behind electrical or communication exterior walls boxes or airsealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed J sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, Inspection of log walls shall be in accordance with the provisions of ICC-400. 3727/20201:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1439 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.270 14. Heating system: Capacity 27.0 c) Area 7c. 151.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 110. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on instal d code compliant features. Builder Signature: Date: Address of New Home: 6702 DONLON ROAD City/FL Zip: FORT PIERCE. FL 327/20201:11:48 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 F8C 6th Edition (2017) Compliant Software Page 1 of 1