HomeMy WebLinkAboutEnergy CodeComponent Performance Method for Commercial Buildings Form 400B-94 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLA/COM-94 Version 2.1A PROJECT NAME_OFFICE WAREHOUSE___________ PERMITTING OFFICE: ADDRESS: GLADES RD. Fort Pierce ------------------ - ----------------- -------------- - FT. PIERCE, FL CLIMATE ZONE: 6 ----------- OWNER: --------------- CAT RECYCLING PERMIT NO: X ------------ AGENT: JURISDICTION NO:661100 ---------------------------- - ------ BUILDING TYPE: _Factory - Industrial_______ CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: _Finished Building__________ CONDITIONED FLOOR AREA: 500 NUMBER OF ZONES: 1 - --------- MAX. TONNAGE OF EQUIPMENT PER SYSTEM :----------- ---- 2_________________ COMPLIANCE CALCULATION: METHOD B DESIGN CRITERIA RESULT ----------------- ENVELOPE PERFORMANCE ------ 39.82 -------- 67.92 ------ PASSES OTHER ENVELOPE REQUIREMENTS PASSES LIGHTING INTERIOR LIGHTING 880.00 1049.33 PASSES EXTERIOR LIGHTING 120.00 270.00 PASSES LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. SEER 10.00 9.70 PASSES HEATING EQUIPMENT AIR DISTRIBUTION SYSTEM INSULATION LEVEL 1. With Insulated Roof 6.00 4.20 PASSES WATER HEATING EQUIPMENT PIPING INSULATION REQUIREMENTS ---------------------------------------------------------------------------- COMPLIANCE CERTIFICATION: I hereby certify that the plans and specifications covered by this calcu- lation are in compliance with the Florida Energy Efficiency Code. PREPARED BY:_________________________ DATE: I hereby certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER/AGENT: -------------------------- DATE: Review of the plans and specifica- tions covered by this calculation indicates compliance with the Florida Energy Efficiency Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, Florida Statutes. BUILDING OFFICIAL: DATE: I I hereby certify(*) that the system design is in compliance with the Florida Energy Efficiency Code. SYSTEM DESIGNER REGISTRATION/STATE ARCHITECT MECHANICAL : _ h7 - - u ---------- --------------- ,PLUMBING ----------------------------------------------------------------- ELECTRICAL: LIGHTING :______________________ ------------------------------------------- ----------------------------------------------------------------- (*) Signature is required where Florida law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. Y 401.---- ZI GLA•NG�-`-'LONE Elevation Type East Commercial South Commercial BUILDING INFORMATION COMPLIANCE CHECK _------------------------- v_ I--------------- U SC VLT Shading___-___ Area(Sgft)I '----------I 1 31 ---- .67 .73 ------ None 121 1.31 .67 .73 None 121 Total Glass Area in Zone 1 = 241 Total Glass Area = 241. 402.------WALLS--ZONE 1---------------------- --U Added R Elevation Type _ ______ ------ --------------------- West Frame Wall + 3" InS. 0.081 11 South Frame Wall + 3" InS. 0.081 11 0.081 11 East Frame Wall + 3" InS. North Frame Wall + 3" InS•008111 Total Wall Area Zone 1 Total Gross Wall Area = Gross(Sgft) 135 342 135 342 954 954 403.------DOORS--ZONE 1----- - U Area(Sgft)I Elevation Type -----I --------- ------------------------------------------ South 1-3/4 Steel Door -Polyurethane core (18 0.29 401 201 North 1-3/4 Steel Door -Polyurethane core (18 0.29 = 601 Total Door Area in Zone 1 Total Door Area =-601 404 ----ROOFS--ZONE 1------- ---------------------------------- U Added R ------I_ Area(Sgft)I Color Type ------- Type ----------1 ____________ ROOF TRUSSES R-30 INSLULATION Light .03 30 1 = 5701 5701 Total Roof Area in Zone 5701 Total Roof Area = 405.______FLOORS-ZONE 1_ R 1 Area(Sg)I Type ------- ----------I _______ ___ ----------------------------- 0 570I Slab on Grade/Uninsulated Total Floor Area in Zone 1 - 5701 Total Floor Area = 5701 406.------INFILTRATION---------------------- ____________________________I___ ICHECKI Infiltration Criteria in 406.1.ABC.1 have been met.I__--_i--- 407.------COOLING SYSTEMS--------------'--'------- IPLV Tons Type No Efficiency -------------- 1. Single Package 408.------HEATING Type 1. No Heating System 409,------VENTILATION 1 10 10 1.50 No Efficiency --o ---------- Ventilation Criteria in 409.1.ABC.1 have been met. Duct- 410.-----AIR DISTRIBUTION SYSTEM---------D- Location AHU Type Duct- 1. Packaged Constant Volume 411.-----PUMPS AND PIPING -ZONE Type -------I--- BTU/hr01 ----- -I--- ICHECKI I I R-value) With Insulated Roof 6 R-value/in Diameter Thicknessl ---------- -- ---------I 0 0 01 1. Non -Circulating _________-� 412.-----WATER HEATING SYSTEMS -ZONE 1----------------------- Type Efficiency StandbyLoss_InputRate ___Gallons 413.-----ELECTRICAL POWER DISTRIBUTION-------- ---------- ICHECK Metering criteria in 413.1.ABC.1 have been met. I Transformer criteria in 413.1.ABC.2 have been met. I __ --__ ____________________________________I_ 414._____MOTORS ___________ __ Motor efficiencies in 414.1.ABC.1 have been met.-_- 415.-----LIGHTING SYSTEMS -ZONE 1----------------- Space Type No Control Type 1 No Control Type 2 No Watts Area-Sgft) - --- -- Reading, T 1 On/Off 2 None 2 880 4901 Total Watts for Zone 1 - 8801 Total Area for Zone 1 = 4901 Total Watts = 8801 Total Area = 4901 ICHECKI Lighting criteria in 415.I.ABC have been met.--_- -I 1 ------------------------------------------------- 16. HVAC load sizing has been performed. (407.1.ABC.1) I I -------------------------------- ----------------------------------I-----I--- 17. Duct sizing and design have been performed. (410.1.ABC.1.2) ---- ---- ------------------------------- --- 18. Testing and balancing will be performed. (410-i.ABC.4) I 1 -------------------------- ----------------------------------------I-----I--- 19. Operation/maintena-ace manual will be provided to owner.(102_1)I-____I-__ -------------------------- I{. '.::..i is � ,, • • ******** PASSES ******** EXTERIOR LIGHTING CRITERIA: AREA AREA AREA OR ALLOWANCE YICODE DESCRIPTION LENGTH WATTS 2 Entrance (without canopy) 6.00 180.00 2 Entrance (without canopy) 3.00 90.00 Exterior Lighting Power Allowance 270.00 W ******** PASSES ******** THE LIGHTING SYSTEM CONTROL REQUIREMENTS: TOTAL EQUIVALENT SPACE NO. CONTROLS CONTROL POINTS NO. DESCRIPTION AREA TASKS TYPE 1 NO. TYPE 2 NO. INSTLD. REQD. 26 Reading, T 490.0 1 On/Off 2 None 2 2= 2 ******** PASSES ******** PROJECT TITLE OFFICE WAREHOUSE BUILDING TYPE Factory - Industrial BUILDING LOCATION : Fort Pierce BUILDING AREA(ft2): 570 HVAC SYSTEMS PERFORMANCE: Cooling System Type Measure #1 #2 Minim. #1 Minim. #2 System Eff.#1 System Eff.#2 Result for #1 Result for #2 Single Pack. SEER 9.70 0.00 10.00 10.00 PASSES Heating System Measure Minimum Req. Efficiency Result ******** PASSES ******** AIR DISTRIBUTION SYSTEM INSULATION LEVELS: Zone # Duct Location Minimum R-Value Design R-Value Result 1. With Insulated Roof 4.20 6.00 PASSES PROJECT TITLE v BUILDING TYPE BUILDING LOCATION BUILDING AREA(ft2): ******** PASSES ******** OFFICE WAREHOUSE Factory - Industrial Fort Pierce 570 HEATING SYSTEMS PRESCRIPTIVE CRITERIA I t PROJECT TITLE OFFICE WAREHOUSE BUILDING TYPE Factory - Industrial 'B,UILDING LOCATION Fort Pierce BUILDING AREA(ft2): 570 `i%JILDING ENVELOPE N NE COMPONENT WALL E PERFORMANCE ORIENTATION SE S SW W NW WEIGHTED AVER. CRITERIA WALL 342 135 342 135 0.03 0.290 GL 0 12 12 0 WWR WWR SC 0.000 0.670 0.670 0.000 0.34 0.500 PF 0.00 0.00 0.00 0.100 0.00 0.00 VLT 0.00 0.73 0.73 0.00 0.37 N/A Uof 0.000 1.310 1.310 0.000 0.66 1.150 W UO 0.04 0.04 0.04 0.04 0.04 0.371 HCJ 1.52 1.52 1.52 1.52 1.52 1 IP 3 3 3 3 3 N/A 0.176 0.117 L 0 A D S 0.271 0.078 TOTAL HEAT 0.642< 3.691 COOL 12.500 6.847 15.311 4.520 39.178< 64.228 SUM 12.676 6.964 15.582 4.598 39.820< 67.918 ******** PASSES ******* OTHER ENVELOPE REQUIREMENTS MAXIMUM PERCENTAGE OF ROOF AREA IN SKYLIGHTS: DESIGN LIMIT Percentage of Roof Area in Skylights 0.000 = 0.0000 MAXIMUM ALLOWABLE Uo: Roof 0.016 < 0.0868 n ******** PASSES ******* PROJECT TITLE OFFICE WAREHOUSE BUILDING TYPE Factory - Industrial BUILDING LOCATION : Fort Pierce BUILDING AREA(ft2): 570 SYSTEM PERFORMANCE CRITERIA BUILDING DESIGN : Interior Lighting Power Exterior Lighting Power INTERIOR LIGHTING CRITERIA: Space . No. Type Area Clg Ht Spaces A 26 490.0 9.0 1 880 W 120 W AF UPI) PB LPB 1.19 1.80 2.14 1047 Unit Power Density Interior Lighting Power Allowance 1.76 W/Gross ft2 2.14 W/Gross ft2 1049 W Total LPB 1047 System Measure Minimum Maximum Design Design Result Type EF / Et SL EF / Et SL r **** Not Applicable **** 1 `PIPING INSULATION REQUIREMENTS: Pipe Insulation Thickness(in) System Type O.D.(in) Minimum Req. Design Result **** Not Applicable ****