Manual S Compliance Report• • ,t- y Job: Bailey-8347 Calumet Ct E-Calcs' ' Date: Plus; Inc.'' First Floor AH By: E-Cales Plus, Inc. E-Calcs Plus, Inc. j' ? - 9250 Corkw Rd, Suite 8, Estero,.FL 33928 Phone: 239.810.6106 Email: edo@ecelcsplus.com Web: �.ecalcsplus.00m Ummie: HERS Rater ID 0757810 For: Design Conditions Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL• 34996 - 19 MAR 0 6 2020 ST. Lucie County, Permitting 11,.j• F, f • OutdoordesignDB: • 90.6cF -Sensible gain: '30137 Btuh Entenng'ooilDB: •76.5'F Outdoor design WB:' _77.80F ,Latent gain: 6585 Btuh 'Ente'drig'coil WB: 63.1'F Indoor design DB: 75.0°F Total gain: 36721:-,.'Btuh IndoorRH: 50% Estimated airflow: 1550 -.6n Manufacturer's Performance Data at:Actuat DdSIgn,Coddltioris,l- Z.; += ' �)° - r11 •= , t r ' ,+•": Equipment type: Split ASHP - Manufacturer: Lennox'� Model:'XP25-048-230-"'+CBA38MV-060-230•++TDR" Actual airflow: 1550 cfm Sensible capacity: 33452 Btuh 1111% of load Latent capacity: 8495 Btuh 129% of load Total capacity: 41947 Btuh 114e/4 of load SHR: 80% Heating Equipment Design Conditions ,Outdoor design DB: 43.0°F Heat loss:. 29807' Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F I Manufacturer's Performance Data at Actual Desigri;Unditionsi Equipment type: SplltASHP = Manufacturer: Lennoxr+ Model: XP25-048-230-`•+CBA38MV-060-230'++TDR Actual airflow: 0 drn " Output capacity: 47000 Btuh 158% of load A. Capacity balance: 31 OF Supplemental.heattrequired: 0 Btuh Economic balance: -Ok OF Backup equipment type: Elec strip Manufacturer: Lennox Model: Actual airflow: 0 cfm Output capacity: 8.7 kW 100%offload Temp. rise:, 50•,'F,, ` Meets all requirements of ACCA Manual S. &—II is CO Y C =11w tnlit. 202o-Mar0514:39:21 .... .,..,., RlghtSuitalUniversal201919.0.12RSU28254 Pagel ...tlBafley-8347 Calumet Ct- Zoned 3.52020.rup Calc=MJ8 FRum Doorfaces: N Job: Bailey - 8347 Calumet Ct Project Summary : ;rl _. per, Pius Inc104n,s Master Suite Zone i By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Su@e 8, Estero, FL 33928 Phone: 239.810.0106 Emall: edc®ecaksplus.wnn Web: w .ecalcsphn.00m Umnse: HERS Rater ID 0757810 Proiect Information For: Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL 34996 Notes: Design Information Weather:, ,:.Vero Beach Muni, FL, US . Winter Design Conditions Outside db 43 °F . Inside db 70 °F Design TD 27 OF Heating Summary Structure 7015 Btuh Ducts 1499 Btuh Central,vent (25 cfm) 0 Btuh Ir, Humidification 0 Btuh Piping 0 Btuh Equipment load 8514 Btuh Inflltration Method Construction quality Fireplaces Simplified Average 0 1 ' Heating Cooling Area (ft) 644 ;1264,, Volume (fN) 11376 11376 Air changes/hour 0.30 0.16,,-- Equiv. AVF (cfm) , 57 31 Heating Equipment -Summary Make n/a Trade n/a Model n/a AHRI ref n/a Efficiency , Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat n/a- 0,'"Btuh, . 0 OF 0, cfm. 0. cfm/Btuh 0, in H2O n/a , .'.Summer. Design.Conditions Outside db 91 OF Inside db- 75 �'F Design TO 16 OF Daily range L Relative humidity 50 % Moisture difference 59 gr/Ib Sensible C_ ooling'Equipment Load Sizing Structure 8084 Btuh Ducts, < ' ' 1977 Btuh Central vent (25 cfm) 0 Btuh Blower, 0 Btuh Use manufacturer's data y Rate/swing multiplier Equipment load 1.00 sensible - , 10060 Btuh Latent Cooling Equipment Load Sizing Structure 1633 , Btuh Ducts 1471 Btuh Central vent (25 cfm) 0 Btuh Equipment latentlload 3104 Btuh Equipment Total Load (Sen+Lat) 13164 Btuh Req. total capacity at O.70 SHR 1.2 ton :_Cooling Equipment Summary Make n/a Trade n/a Cond n/a Coil n/a AHRI ref n/a Efficiency n/a Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual air flow 0 cfm Airflow factor 0 cfm/Btuh Static pressure 0 In H2O Load sensible heat ratio 0 Calculations approved by ACCA to meet all.requirements of Manual J 8th Ed. M 1011. aoM' 2020-Mar-0514:38:21 --- RlghtSuite4DUnlyersal201919.0.12RSU28254 Page ...Malley-8347 Celurnet Ct- Zoned 3.5.2020.rup Calc=MIB Front Door faces: N Project Summary E-Calcs Office BR2 Zone Plus, Inc.' E-Calcs Plus, Inc. FL 33928 Phone: 239.810.6106 Emal Job: Bailey - 6347 Calumet Ct Data: t I By: E-Calcs Plus, Inc. For: Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL 34996 :1 Notes: Design Information Weather: Vero Beach Muni, FL, US Winter Design Conditions I Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference . •- 59 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 7051 Btuh Structure 8767 Btuh Ducts 1507 Btuh Ducts 2144 Btuh Central vent (24 dm) 0 Btuh Central vent (24 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping • 0 Btuh Equipment load 8557 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 10911 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average , . Fireplaces 10, Structure 2003 Btuh Ducts 1420 Btuh Central vent (24 cfm) 0 Btuh Heating Cooling Area (ft') 1220 1220 Equipment latent load 3422 Btuh Volume (fl') 10980 - 10980 Air changes/hour 0.41 0.22 Equipment Total Load (Sen+Lat) 14333' Btuh Equiv. AVF (cfm) 74 40 Req. total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Make n/a Trade n/a Model n/a AHRI ref n/a Efficiency Heating input Heating output ... Temperature rise Actual air flow Air flow factor Static pressure Space thermostat n/a 0 -Btuh 0 0 cfm 0 cfm/Btuh 0 in H2O n/a Cooling Equipment Summary Make n/a Trade n/a- Cond n/a Coil n/a AHRI ref n/a Efficiency n/a Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling , 0 Btuh Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Static pressure 0 In H2O Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual'J 8th Ed. 41- wrl htsof 2020-Mar-0514.3821 --- RlghtSulte® Universal 2019 19.0.12 RSU28254 Page 7 AM...t18e1ey-8347 Calumet Ct- Zoned 3.52020.rup Calc=MJ8 Front Door faces:N E-Gales Load Short Form i:t Job: Bailey-8347 Calumet Ct Date: Plus, Inc.' Entire House i By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suita 8, Est -am, FL 33928 Phone: 239.810.6106 Emak edc@ecalcsplus.com Web: www.scalcsplus.com License: HERS Rater ID 0757810 Project• • For: Bailey - 8347 Calumet Ct • 8347 Calumet Ct, Stuart, FL 34996 Design• • Htg Clg Infiltration Outside db (°F) 43 91 Method Simplified Inside db (OF) 70 75 r,• Construction quality : Average Design TD (°F) 27 16 Fireplaces 0 Daily range I- 14c L Inside humidity (%) 50 50 Moisture difference (gr/Ib) 22 59 HEATING EQUIPMENT. Make n/a Trade ' n/a Model n/a AHRI ref n/a Efficiency, Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat n/a n/a 0 Btuh 0 ,F 0 cfm 0 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make n/a, Trade n/a Cond We Coil n/a AHRI ref n/a Efficiency n/a Sensible cooling 0 Btuh Latent'cooling' 0 Btuh Total cooling 0 Btuh Actual air flow 0 cfm Air flow.factor 0 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0 ROOM NAME Area - Htg load Clg load Htg AVF 'Cig AVF (fl=) (Btuh) (Btuh) (cfm) (cfm) First Fllior AH ' d ' ' `3510 28543 29411 r 0 1550 Second Floor AH d 4650 29697 36079 0. 1933 Entire House d 8160 58240 65519 0 3590 Other equip loads 3978 2284 Equip. @ 1.00 RSM 67803 Latent cooling 15998 Tf1TC152 1 8160 ' 62 1 I . I .. 1 2 9 8380 3590 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C * wrightsoft- " ` 2020-Mar-0514.38s1 ....-, 1.--., RlghtSulte® Universal 201919.0.12 RSU28254 Pagel ... tlBaliey-8347 Calumet Ct- Zoned 3.5.2020.rup Colo =MJ8 Front Door faces:N Load Short Form' Job: Bailey -8347Calumet Ct E-Calcs Date: Plus, Inc. First Floor AH By: E-Cabe Plus, Imw E-Calcs Plus', Inc. 9250 Corkscrew Rd, Suites, Estero, FL 33928 Phone: 239.8.10.6106 Email: erlC@ecelcsplus.cam Web: v .ecalceplue.com License: HERS Rater ID 0757810 Project Information For. Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL 34996 Htg CI9 Infiltration Outside db (OF) 43 91 Method Simplified Inside db (OF) 70 75 Construction quality Average Design TO (OF) 27 16 Fireplaces Daily range - L Inside humidity (%) 50 50 Moisture difference (glib) 22 59 HEATING EQUIPMENT Make Lennox Trade LENNOX Model XP25-048-230-" AHRI ref 202073556 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacitybalance point= 31 OF 10.2 HSPF 47000 Btuh@47-F 0 OF 0 cfm 0 cfm/Stuh 0.50 in H2O Backup:Lennox Input = 9 kW. Output = 29808 Btuh. 100 AFUE COOLING EQUIPMENT Make Lennox Trade LENNOX Cond XP25-048-230" Coil CBA38MV-060-230•++TDR AHRI ref 202073556 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13.0 EER, 20 SEER 32550 Stull 13950 Btuh 46500 Btuh 1550 cfm 0.053 cfm/Btuh 0.50 in H2O 0.82 ROOM NAME Area YF) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Kit Liv Din 2866 20143 20322 0 1071 Utility 230 3443 2364 0 125 Den 180 1560 3181 0 168 BA 60 337 1065 0 56 WIC 30 676 776 0 41 Pantry 88 1335 950 0 50 Q.-.r..... CC OCA I..t JV VJV IJ7 .- .' Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. YU Wrtghttsofr 2020-Mar-0514:38:21 y�:7.� .,....,,......,..,.�., Right-SulleG Universal 201919.0.12 RSU28254 Paget �+M ...re"ley - 8347 Calumet Ct- Zoned 3.5.2020.rup Calc=Wit Front Door laces: N First Floor AH d 3510 28543 i 29411 r^ 0 1550 Other equip loads 1264 � 726 Equip. @ 1.00 RSM 30137 Latent cooling 6585 ` Y^rA! a I . nun I nnon-1 I n ^A I I v •..ram - _ _ _ _ IJJV_ a Calculations approved by ACCA to meet all requirements of Manual,J 8th Ed. C '*' wrightsofte 2020-Mar-0514:38:21 1�� .+e..,«..r......o� RlghtSuite® Universal 201919.0.12 RSU28254 Page3 /R+Gl1... faalley-8347 Calumet Ct-Zoned 3.5.2020.mp Calc=MJ8 Front Dcorfaces: N Job: Bailey -a347 Calumet Ct ' Load Short Form �' • • oar: E-Calcs ,lus,III S@COnd Floor AH By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: edc@ecalcsplus.com Web: w .enalasplus.wrn License: HERS Rater to 0757610 For: Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL 34996 Htg Clg Outside db (OF) 43 91 _ Ins idedb(OF) 70 75 Design TO (°F) 27 16 Daily range - L Inside humidity (°/a) 50 50 Moisture difference (gr/Ib) 22 59 HEATING EQUIPMENT Make Lennox Trade LENNOX Model XP25-060-230-" AHRI ref 201930689 Efficiency 10 HSPF Heating input 1.. Heating output 54500 Btuh @ 47-F Temperature rise 0 OF Actual air flow 0 cfm . Air flow factor 0 dm/Btuh Static pressure. 0.50 in H2O =. Space thermostat 1. Capacitybalance point= 29 OF Backup: LennoxAFUE 100 inn, it = r lrW rl itnut = 17nR1 Rtiih inn API IF • J 1 Infiltration Method Construction quality Fireplaces Simplified Average 0 COOLING EQUIPMENT Make Lennox Trade LENNOX Cond XP25-060-230" Coil CBA38MV-060-230-++TDR AHRI ref 201930689 Efficiency 12.5 EER, 19.5 SEER Sensible cooling, 40600 'Btuh Latent cooling' 17400 Btuh Total cooling 58000 Btuh Actual air flow,` 1933 dm Air flow factor 0.053 dm/Btuh Static pressure' 0.50 in H2O Load sensible heat ratio 0.72 1. ROOM NAME Area Htg load big load Htg AVF Clg AVF (f 2) (Btuh) (Btuh) (dm) (dm) Master Suite Zone . p 1264 8514 ' - 10060 0 533 Loft OTB Zone p 1542 8425 11971 0 635 Office BR2 Zone p `...1220 '8557 10911 0 579 BR4 BR3 Zone p :} 624 4201 5533 0 293 Second FloorAH d 4650 .29697 36079 0 1933 Other equip loads 2715 1558 Equip. @ 1.00 RSM 37638 Latent cooling 14821 Tl1TA1 [. I ACL/. I 7/IA.1 /f C/fACn I n I AnoJ Calculations,approved byACCA to meet all•requirements of Manual J 8th Ed. wrightsoW 2020-Mar-0514.38:21 .,.,.., RlghtSulte® Universal 201919.0.12 RSU28254 Page a �...NBaDey-8347 Calumet LY-Zoned 3.5.2020aup CaIc=MJB Frant Door lems:N Load Short Form Job: Bailey-8347 Calumet Ct <nI Plus, Inc. Date: E-Calcs BR4 BR3 Zone By: E-Cal1s Plus, Inc. E-Calcs Plus, Inc. 9260 Corksuew Rd, Suite 8, Estem, FL 33928 Phone: 239.810.6106 -Email: edc@KsImplus.com Web: w .ecalmplus.00m License: HERS Rater ID 0757810 Project• • For. Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL 34996 Design• • Htg CIg Infiltration Outside db (OF) 43 91 Method Simplified Inside db (°F) 70 75 Construction quality ' Average Design TD (°F) 27 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/Ib) 22 59 . HEATING EQUIPMENT !'COOLING -EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency - ' ' n/a Heating input Sensible cooling 0 Btuh Heating output 0, Btuh latent cooling.' 0 Btuh Temperature rise 0 OF, Total cooling 0 Btuh Actual air flow 0 cfrn Actual air flowt 0 cfm Air flow factor - 0 cfm/Btuh Air flow factor 0 cfm/Btuh' Static pressure- 0 in H2O Static pressure ' 0• in H2O Space thermostat n/a Load sensible heat ratio . 0• ROOM NAME Area. Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) BR 4 244 1351 2039 0 108 Sinks 48 116 541 0 29 BR 3 272 2319 2678 0 .:I 142 BA 2 60 414 275 0 15 BR4 BR3 Zone p 624 4201 5533 0 293 Other equip loads 0 0 Equip. @ 1.00 RSM 5533 , Latent coaling 1879 Tl1TAI C cne • - •..-� vr� tcW , r t ra V AvJ' Calculations approved by ACCA to meet all requirements of.Manual J 8th Ed. ti wrightsoft- 2020•Mar-0514:38:21 .....•, ..�.,..., Rig htSulte® U nivereel 201919.0.12 RSU28254 Page ...tlBalley-8347 Calumet Ct- Zoned 3.5.2020.mp Celc=MJ8 Front Door faces: N Load Short Form Job: Bailey -8347Calumet Ct E-Calcs''-' Plus. Inc. Loft OTB Zone Date: - By: E-Calce Pius, Inc. E-Calcs Plus, Inc. 9250 Corks: Rd, Sufte 8, Estero, FL 33928 Phone: 239.810.8106 Email: edc@emlmplus.com Web: viww.emtmplus.mm License: HERS Rater ID 0757810 Project• • For: Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL 34996 - Design Information Htg Cig Infiltration Outsidedb (°F) 43 91 Method Simplified InsideAb (°F) 70 75 Construction quality Average Design TD (°F) 27 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/Ib) 22 59 "- HEATING. EQUIPMENT COOLING -EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref We Efficiency n/a Efficiency In/a Heating input Sensible cooling 0 Btuh' Heating output 0 Btuh Latent cooling 0 • Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 0 ctm Actual air flow 0 ctm Air flow factor : 0 cfm/Btuh " Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static'pressure' 0 in H2O ' Space thermostat n/a . , - - Load sensible heat ratio a - ROOM NAME Area.. Htg load Clg load Htg AVF Cig AVF (W) (Btuh) (Btuh) (cfm) (cfm) OTB 540 4437 7156 0 379 Loft 1002 3988 4815 0 255 Loft OTB Zone p 1542 8425 11971 0 635 Other equip loads 1 0 0 Equip. @ 1.00 RSM 11971- Latent cooling 2726 Tn'rA1 C I eeAn I Gene I eAGn-1 I n. l Gnc 'Calculations approved by ACCA to meet all requirements of Manual J Bth Ed. y wrightsoft• 2620-Mar-0514:38:21 !�►y ..w•, �..,., RlghtSuite® Universal 201919.0.12 RSU28254 Page ...tlBatey-8347 Calumet Ct- Zoned 3.5.2020.rup Calc=MJB Front Door faro.N Load Short Form Job: Bailey -8347Calumet Ct E-Calcs Date: Plus, Inc. Master Suite Zone ` By: E-Caics Plus, Inc. E-Calcs Plus, Inc. I 9250 Corks Rd, Suite 8, Emem, FL 33928 Phone: 239.810.6106 Emall: edc@ecalcsplus.com Web: v .ecalcsplus.com License: HERS Rater ID 0757810 Project• • For: Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL 34996 Design Information Htg Clg Infiltration Outside db (°F) 43 91 Method Simplified. Inside db (°F) 70 75 Construction quality Average Design TD (OF) 27 16 Fireplaces0 Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 22 59 -,',HEATING EQUIPMENT Make n/a Trade n/a Model n/a AHRI ref n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat n/a n/a 0 Btuh 0 OF 0 cfm 0 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make n/a Trade n/a Cond n/a Coil n/a AHRI ref n/a Efficiency n/a Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual airflow 0, cfm , Airflow.factor ; 0 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft') (Btuh) (Btuh) (cfm) (cfm) Master BR 600 4174 6023 0 319 Master BA 384 2859 2154 0 114 MT 24 546 555 0 29 His WIC 120 683 647 0 34 Her WIC 136 252 681 0 36 Master Suite Zone p 1264 8514 10060 0 533 Other equip loads - 0 0 Equip. @ 1:00 RSM 10060 Latent cooling 3104 Tr1TAl g I 90cA oe4A I Aonca I n 000 Calculations approved by;ACCA•to meet all requirements,of Manual J 8th Ed. *'wrtght_sofC zoza neaws 14:38:21 L`• ...+-, ..._,...,-. Right -Suits® U niversel 201919.0.12 RSU28254 Page ...tlBalley-8347 Calumet Ct- Zoned 3.5.2020.mp Colo =We Front Door faces: N Load Short Form E-Calcs Office BR2 Zone Plus, Inc. E-Calcs Plus, Inc. Job: Bailey - 8347 Calumet Ct Date: By: ECalcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, Fl- 33928 Phone: 239.810.6106 Email: edc@eoaicspius.=nn Web: w .eralcsplus.com Ucense: HERS Rater ID 0757810 For. Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL 34996 ° Htg Clg Infiltration Outsidedb (°F) 43 91 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 27 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 22 59 HEATING EQUIPMENT COOLING EQUIPMENT Make We Make n/a Trade n/a Trade We Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual airflow 0 cfm Actual airflow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (fl') (Btuh) (Btuh) (cfm) (cfm) Office 484 3781 4824 0 256 Laundry 144 781 1681 0 89 BR 5 272 2285 2365 0 125 BA 3 60 391 257 0 14 BR2 260 1318 1784 0 95 Office BR2 Zone p 1220 8557 10911 0 579 Other equip loads 0 0 Equip. @ 1.00 RSM 10911 Latent cooling 3422 T^TAI C I ,IO 1 OGG7 I .I A0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ' C -Pk wrightsoft• 2020-Mar-0514:38:21 �y .,....,. ...�.., RlghtSuite4DUnNersal2019l9.0.12R5U28254 Pages r� ...lis'lley- 8347 Calumet Ct-Zoned 3.52020.rup Calc=MJ8 Fmnt Door(eces: N i i Job M Bailey - 8347 Calumet Ct Performed by E-Cales'Plus, Inc. for: Bailey -8347 Calumet Ct- 8347 Calumet Ct Stuart, FL 34996 r . First Floor E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8 Estero, FL33928 Phone: 239.810.6106 www.ecaicsplus.com edc@ecalcsplus.00m Scale: 1 : 141 . Page.1 .. PoghtSuite® Universal 2019 19.0.12 RSU28254 2020-Mar-05 14:38:46 ... Calumet Ct-Zoned 3.5.2020.mp s ■ tt i N Second Floor J t Job M Bailey - 8347 Calumet Ct E-Calcs Plus, Inc. Scale: 1 : 1a1 Performed by E-Calcs Plus, Inc. for: Page z Bailey-8347 Calumet Ct 9250 Corkscrew Rd, Suite 8 WghtSulte® Universal 2019 8347 Calumet Ct Estero, FL 33928 19.0.12 RSU28254 Stuart, FL 34996 Phone: 239.810.6106 2020-Mar-05 14:38:48 www.ecaicsplus.com edc@ecalcsplus.com ... Calumet Ct-Zoned 3.5.2020.rup Duct System Summary E-Calcs First Floor AH Plus, Inc. E-Calcs Plus, Inc. Job: Bailey • 8347 Calumet Ct Date: By: E-Cales Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estate, FL 33928 Phone: 239.810.6106 Email: ericQo ecalcsplus.com Web: w .ecalcsplw.com Ucense: HERS Rater ID 0757810 i"roject Intormation For. Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL,34996 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.16 in H2O 0.16 in H2O Available static pressure 0.34 in H2O 0.34 in H2O Supply / return available pressure 0.262 / 0.078 in H2O 0.262 / 0.078 in H2O Lowest friction rate 0.101 in/100ft 0.101 in/100ft Actual air flow 0 cfm 1550 Cfm Total effective length (TEL) 338 ft Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA c 1065 0 56 0.142 6.0 OxO VIFx 54.1 130.0 st1 Den c 3181 0 168 0.151 8.0 Ox0 VIFx 42.8 130.0 st1 Kit Uv Din c 2903 0 153 0.105 8.0 Ox0 VIFx 95.2 155.0 st2 Kit LivDin-A c 2903 0 153 0.141 8.0 OxO VIFx 55.8 130.0 st1 Kit Llv Dln-B o 2903 0 153 0.150 8.0 Ox0 VIFx 44.9 130.0 st1 ict Uv Dln-c c 2903 0 153 0.108 8.0 Ox 0 VIFx 86.7 155.0 st2 Kituvoin-D c 2903 0 153 0.148 8.0 Ox0 VIFx 46.3 130.0 st1 Kit Uv Din-E c 2903 0 153 0.101 8.0 Ox 0 VIFx 105.0 155.0 st2 I9t Ltv Din-F c 2903 0 153 0.152 8.0 Ox0 VIFx .42.6 130.0 st1 Pantry c 950 0 50 0.110 6.0 Ox 0 VIFx 83.7 155.0 st2 Storage c 754 0 40 0.107 5.0 OxO VIFx 89.7 155.0 st2 Utility c 2364 0 125 0.102 8.0 OxO VIFx 96.4 160.0 st2 wic c 776 0 41 0.1361 5.01 Ox 0 VIFx 63.0 130.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 0 877 0.136 628 16.0 0 x 0 VinlFlx st2 Peak AVF 0 673 0.101 630 14.0 0 x 0 VinlFlx !� W rigintSoft- 2020-Mar-0514:38:21 Alvld� .-1 .._,.-.-, Rig htSuite® U niversel 201919.0.12 RSU28264 Pagel ...Malley-8347 Calumet Ct- Zoned 3.52020.mp Cole =We FroMDoor faces: N Return Branch Detail Table Name Grille Size (in) Htg (dm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat] Trunk rb1 Ox 0 ".: _ 0 1550 78.0 .' 0.101: _ 689 - .17.1 "18x -18 RtF g'- p!. wrighLSOgt' 2020-Mar•0514.38.21 u..•-.+�—oft RlghtSulte® Universal 201919.0.12 RSU28254 Paget r� ...ffialley-8347 Calumet Ct- Zoned 3.52020.rup Calc=MJ8 Front Dmr%ws: N Duct System Summary Job: Bailey-8347 Calumet Ct E-Calcs Date: Plus, Inc. Second Floor AH By: E-Cales Plus, Inc. E-Calcs Plus, Inc. 9250 corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: edo@ecaicspius.mm Web: w .eoalcsplus.com License: HERS Rater ID 0757810 I , Project• • For. Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL 34996 External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.176 / 0.164 in H2O 0.084 in/100ft 0 cfm Cftb7 Cooling 0.60 in H2O 0.16 in H2O 0.34 in H2O 0.176 / 0.164 in H2O 0.084 in/100ft 1933 cfm Name Design (Btuh) Hill (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA2 c 275 0 15 0.092 4.0 Ox0 VIFx 62.1 130.0 st3 BA3 C 257 0 14 0.116 4.0 Ox0 VIFx 26.5 125.0 st6 BR 3 c 2678 0 142 0.090 8.0 Ox 0 VIFx 65.8 130.0 st3 BR2 C 1784 0 95 0.125 7.0 Ox0 VIFx 16.0 125.0 st6 BR4 c 2039 0 108 0.087 8.0 OxO VIFx 73.0 130.0 st3 BR 5 C 2365 0 125 0.108 8.0 OxO VIFx 32.4 130.0 st6 Her WIC c 681 0 36 0.099 5.0 OxO VIFx 48.4 130.0 st4 His WIC c 647 0 34 0.093 5.0 Ox0 VIFx 60.2 130.0 st4 Laundry o 1681 0 89 0.120 7.0 OxO VIFx 22.0 125.0 st6 Left c 2408 0 128 0.094 8.0 Ox0 VIFx 56.4 130.0 st5 Loft -A o 240B 0 128 0.094 8.0 Ox0 VIFx 58.0 130.0 sty MT c 555 0 29 0.084 5.0 Ox0 VIFx 69.5 140.0 st4 Master BA c 2154 0 114 0.094 8.0 OxO VIFx 56.8 130.0 st4 Master BR c 3012 0 160 0.098 8.0 Ox0 VIFx 48.8 130.0 st4 Master BR -A c 3012 0 160 0.105 8.0 Ox0 VIFx 37.8 130.0 st4 OTB o 3578 0 190 0.103 9.0 Ox0 VIFx 40.3 130.0 st5 OTB-B c 3578 0 190 0.102 9.0 Ox0 VIFx 43.2 130.0 st5 Office c 2412 0 128 0.115 8.0 Ox0 VIFx 28.0 125.0 st6 Of ice -A c 2412 0 128 0.116 8.0 OxO VIFx 26.2 125.0 st6 Sinks c 541 0 29 0.091 5.0 OxO VIFx 64.3 130.0 st3 ' Wrfghtso t- 2020-Mar-0514.3821 ��►yy ...«, ......,-, Rig ht-Suite® U nlversal 201919.0.12 RSU28254 Page Al.rl+N...tlllailey-8347 Calumet Ct- Zoned 3.5.2020.mp Cale =MJ8 Front Door faces: N Trunk Htg cig Design Veloc Diam - H x W „ Duct Name Type (dm) (cfm) FIR (fpm) (in) (in) Material Trunk st3 Peak AVF 0- - 293 0.087 _ _ 374._-' _ -0 x._0__ -_VinlFlx__--_ st4 Peak AVF 0 ' 533 0.084 499 _12.0 14.0 0 x 0 _ VinlFlx st5 Peak AVF 0 635 0.094 594 14.0 0 x 0 VinlFlx st6 Peak AVF 0 579 0.108 541 14.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mail Trunk rb5 0x0 ••0. 533 80.4 0.204 679 12.0 Ox 0 VIFx rb7 Ox0 0 137 185.6 0.088 392 8.0 Ox 0 VIFx rt4 rb8 0x0 0 157 195.5 0.084 354 9.0 Ox 0 VIFx rt4 rb10 Ox0 0 108 121.7 0.135 405 7.0 Ox 0 VIFx ' rt3 rb9 Ox0 0 125 130.9 0.125 469 7.0 Ox 0 VIFx rt3 rb6 Ox0 0 256 92.4 0.178 579 9.0 Ox 0 VIFx rt2 rb2 I Ox0 01 7241 100.E 1 0.163 677 14.0 Ox 0 VIFx rig Trunk Htg clg Design Veloc Diam H x W Duct Name Type (ofm) (elm) FIR (fpm) (in) (in) Material Trunk rt2 Peak AVF 0 980 0.163 702 16.0 0 x 0 VinlFlx rt3 Peak AVF 0 527 0.084 493 14.0 0 x 0 VinlFlx rt4 Peak AVF 0 293 0.084•,- - 374 12.0 0 x 0 VinlFlx rt3 fY 2020-Mar-0514:3821 wHghtso ..soft Right-Sulte® Universal 201919.0.12 RSU28254 Page AM ... WOW -8347Calumet Ct-Zoned 3.5.2020.rup Calc=MJ8 FrontDoorfaces:N Static Pressure and Friction Rate Job: Bailey -8347Calutneici %r P, lus.In _D IusIn s — Baca: c. First Floor-AH By: E-ales Plus, Inc. E-Calcs Plus, Inc.' 9250 Corkscrew Rd, Sue 8, Estero, FL 33928 Phone: 239.810.6106 Email: edCQecalosplus.mm Web: vmv.ecalcsplus.wrn License: HERS Rater ID 07578.10 For: Bailey - 8347 Calumet Ct - 8347 Calumet Ct, Stuart, FL 34996 Heating Cooling (in H2O) (in H2O) External static pressure 0.50 .0.50 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 - 0.02 Return grilles 0.03 0.02 Filter 0.10 0.1 C Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 , 0.34 Total. supply , Return ' (ft) (ft) Measured length of run -out 27 8 Measured length of trunk 78' 0 Equivalent length of fittings 155 70 Total length 260 78 Total effective length 338 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.101 OK 0.101 OK Return Ducts 0.101 OK 0.101 OK Fitting Equivalent LengthDetails I 4AD=60, 11A=20, 11G=5, 1A=35, 11G=5, 11G=5, 11G=5, 11G=5, 11G=5, 11G=5, 11G=5: TotalEL=155 Return 6M=20, 111=10, 5A=40: TotalEL=70 wNghtsofC zozo-near-0514:3821 !may .....,.r. soll't RlghtSulte® Universal 201919.0.12 RSU28254 Pagel /F+CA� ...asliley- 8347 Calumet Ct. Zoned 3.52020.mp Cain = MJ8 Front Door faces: N fPius Static Pressure and Friction Rate Job: Bailey -8347Calumet Ct ` zl lus jn s Baca: , inc. Second Floor AH By: E-Calca Plus, lRa E-Calcs Plus, Inc. 9250 Corksvew Rd, Suite 8, Estero, Fl. 33928 Phone: 239.810.6106 Email: eric@ecalwp1u9.mm Web: v .eralcsplus.mm Ucense: HERS Rater ID 0757810 For: Bailey - 8347 Calumet Ct 8347 Calumet Ct, Stuart, FL 34996 Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.02 Return grilles 0.03 0.03 Filter 0.10 0.1 C Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 0.34 Total• Supply Return (ft) (ft) Measured length of run -out 37 16 Measured length of trunk 33 64 Equivalent length of fittings 140 115 Total length 210 195 Total effective length 405 Friction Rate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.084 OK 0.084 OK Return Ducts 0.084 OK 0.084 OK Fitting Equivalent Length Details Supply 11A=20, 4AD=60, 11G=5, 11G=5, 11G=5, 1A=35, 11G=5, 11G=5: TotalEL=140 Return 6M=20, 11M=20, 11G=5, 11A=20, 5D=40, 11G=5, 11G=5: TotalEL=115 "�' M gti Soft. 202D-Mar-0514:38:21 f- .....,,..._....,o-, RlghtSulte® Universal 201919.0.12 RSU28254 Page ...118a0ay-8347 Calumet Ct- Zoned 3.5.2020.rup Catc=MJB Front Doorfaces: N