HomeMy WebLinkAboutEngery CalsFlorida Building Code, Sixth Edition (2017) - Energy Conservation
EnergyGauge Summit® Fla/Com-2017, Effective Date: Dec 31, 2017
IECC 2015 - Total Building Performance Compliance Option
Check List
Applications for compliance with the Florida Building Code, Energy Conservation shall
include:
This Checklist
The full compliance report generated by the software that contains the project
summary, compliance summary, certifications and detailed component compliance
reports.
The compliance report must include the full input report generated by the software as
contigous part of the compliance report.
Boxes appropriately checked in the Mandatory Section of the complaince report.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 1 of 20
PROJECT SUMMARY
Short Desc:Offices Description:California Clos - 807 S Kings Hwy
Owner:
Address1:807 S Kings Hwy City:Fort Pierce
Address2:State:FL
Zip:34945
Type:Office Class:Renovation to existing building
Jurisdiction:FORT PIERCE, ST LUCIE COUNTY, FL (661100)
Conditioned Area:1990 SF Conditioned & UnConditioned Area:1990 SF
No of Stories:1 Area entered from Plans 1990 SF
Permit No:0 Max Tonnage 5
If different, write in:______________________
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 2 of 20
ResultCriteriaDesignComponent
Compliance Summary
Gross Energy Cost (in $) 1,087.0 1,578.0 PASSED
LIGHTING CONTROLS PASSES
EXTERNAL LIGHTING No Entry
HVAC SYSTEM PASSES
PLANT No Entry
WATER HEATING SYSTEMS PASSES
PIPING SYSTEMS No Entry
Met all required compliance from Check List?Yes/No/NA
IMPORTANT MESSAGE
Info 5009 -- -- -- An input report of this design building must be submitted along with this
Compliance Report
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 3 of 20
CERTIFICATIONS
I hereby certify that the plans and specifications covered by this calculation are in compliance with the
Florida Energy Code
Prepared By: __________________Building Official: __________________
Date: _________________Date: __________________
I certify that this building is in compliance with the FLorida Energy Efficiency Code
Owner Agent: __________________Date: __________________
If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida Energy
Efficiency Code
Architect: __________________Reg No: __________________
Electrical Designer: __________________Reg No: __________________
Lighting Designer: __________________Reg No: __________________
Mechanical Designer: __________________Reg No: __________________
Plumbing Designer: __________________Reg No: __________________
(*) Signature is required where Florida Law requires design to be performed by registered design
professionals. Typed names and registration numbers may be used where all relevant information is
contained on signed/sealed plans.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 4 of 20
E-Calcs Plus, Inc.
July 14, 2020
Project: Offices
Title: California Clos - 807 S Kings Hwy
Type: Office
(WEA File: FL_ST_LUCIE_CO_INTL.tm3)
1) Proposed 2) Baseline
Total 70.10
$1,087
119.40
$1,856
ELECTRICITY(MBtu/kWh/$)70.10
20580
$1,087
119.40
34956
$1,856
AREA LIGHTS 9.40
2768
$146
35.40
10360
$550
MISC EQUIPMT 29.90
8747
$462
29.90
8747
$464
PUMPS & MISC 0.00
8
$0
0.00
12
$1
SPACE COOL 19.40
5694
$301
28.30
8279
$440
SPACE HEAT 0.00
10
$1
0.20
49
$3
VENT FANS 11.40
3353
$177
25.60
7509
$399
Building End Uses
Credits Applied: None
Passing Criteria = 1578
Design (including any credits) = 1087
Passing requires Proposed Building cost to be at most 85% of
Baseline cost. This Proposed Building is at 58.5%
PASSES
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 5 of 20
CLP
(W)
Area or Length
or No. of Units
(Sqft or ft)
Allowance
(W/Unit)
CategoryDescription
External Lighting Compliance
ELPA
(W)
Tradable?
None
Project: Offices
Title: California Clos - 807 S Kings Hwy
Type: Office
(WEA File: FL_ST_LUCIE_CO_INTL.tm3)
ComplianceDesign
CP
Min
CP
DescriptionAcronym
Lighting Controls Compliance
Ashrae
ID
Area
(sq.ft)
10,004 Exam/Treatment (Hospital) 1,990 1 14 PASSESOffices
PASSES
Project: Offices
Title: California Clos - 807 S Kings Hwy
Type: Office
(WEA File: FL_ST_LUCIE_CO_INTL.tm3)
System Report Compliance
Split AC 1 ea. 5 ton Split AC Constant Volume Air Cooled
Split System < 65000 Btu/hr
Component Category Capacity Design
Eff
Eff
Criteria
Design
IPLV
IPLV
Criteria
Comp-
liance
No. of Units
1
Cooling System Air Conditioners Air
Cooled Split System <
65000 Btu/h Cooling
Capacity
60000 14.00 13.00 12.90 PASSES
Heating System Electric Furnace 34000 1.00 1.00 PASSES
Air Handling
System -Supply
Air Handler (Supply) -
Constant Volume
2000 0.60 0.82 PASSES
PASSES
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 6 of 20
Comp
liance
CategoryMin
IPLV
Min
Eff
Design
IPLV
Design
Eff
SizeInstalled
No
Description
Plant Compliance
None
Project: Offices
Title: California Clos - 807 S Kings Hwy
Type: Office
(WEA File: FL_ST_LUCIE_CO_INTL.tm3)
Comp
liance
Design
Loss
Design
Eff
Max
Loss
Min
EffCategoryTypeDescription
Water Heater Compliance
Water Heater 1 Electric water heater <= 12 [kW] 0.97 0.98 PASSES
PASSES
Piping System Compliance
Category Pipe Dia
[inches]
Ins Cond
[Btu-in/hr
.SF.F]
Operating
Temp
[F]
Is
Runout?
Ins
Thick [in]
Compl-
iance
Req Ins
Thick [in]
None
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 7 of 20
Topic Section Component Description
Yes N/A Exempt
Mandatory Requirements (as applicable)Mandatory requirements compiled by US Department
of Energy and Pacific Northwest National Laboratory.
Adopted with permission
1. To be checked by Designer or Engineer
Insulation C303.2 Envelope Below-grade wall insulation installed per
manufacturer's instructions.
Insulation C303.2 Envelope Slab edge insulation installed per manufacturer's
instructions.
Insulation C303.2 Envelope Above-grade wall insulation installed per
manufacturer's instructions.
Insulation C402.3 Envelope High-albedo roofs satisfy one of the following:
3-year-aged solar reflectance >= 0.55 and thermal
emittance >= 0.75 or 3-year-aged solar
reflectance index >= 64.0.
Fenestration C402.4.4 Envelope U-factor of opaque doors associated with the
building thermal envelope meets requirements.
SYSTEM_SPECIFIC C403.2.12.1 Mechanical HVAC fan systems at design conditions do not
exceed allowable fan system motor nameplate hp
or fan system bhp.
SYSTEM_SPECIFIC C403.2.12.2 Mechanical HVAC fan motors not oversized beyond allowable
limits.
SYSTEM_SPECIFIC C403.2.3(8) Table Mechanical Heat Rejection Equipment: Minimum Efficiency
Requirement meet those listed in Table
C403.2.3(8)
HVAC C403.2.7 Mechanical Exhaust air energy recovery on systems meeting
Table C403.2.7(1) and C403.2.7(2).
SYSTEM_SPECIFIC C403.3 Mechanical Air economizers provided where required, meet
the requirements for design capacity, control
signal, ventilation controls, high-limit shut-off,
integrated economizer control, and provide a
means to relieve excess outside air during
operation.
SYSTEM_SPECIFIC C403.3.2 Mechanical Economizer operation will not increase heating
energy use during normal operation.
SYSTEM_SPECIFIC C403.3.4,
C403.3.4.1,
C403.3.4.2,
C403.3.1
Mechanical Water economizers provided where required,
meet the requirements for design capacity,
maximum pressure drop and integrated
economizer control.
SYSTEM_SPECIFIC C403.4.2.1 Mechanical Three-pipe hydronic systems using a common
return for hot and chilled water are not used.
SYSTEM_SPECIFIC C403.4.2.3.1 Mechanical Hydronic heat pump systems connected to a
common water loop meet heat rejection and heat
addition requirements.
SYSTEM_SPECIFIC C403.4.3.4 Mechanical Open-circuit cooling towers having water cooled
chiller systems and multiple or vairable speed
condenser pumps, are designed so that tower
cells can run in parallel with larger of flow crtieria.
SYSTEM_SPECIFIC C404.2 Mechanical Service water heating equipment meets efficiency
requirements.
Wattage C405.3 Interior Lighting Exit signs do not exceed 5 watts per face.
2. To be checked by Plan Reviewer
Plan Review C103.2 Envelope Plans and/or specifications provide all information
with which compliance can be determined for the
building envelope and document where
exceptions to the standard are claimed.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 8 of 20
Plan Review C103.2 Mechanical Plans, specifications, and/or calculations provide
all information with which compliance can be
determined for the mechanical systems and
equipment and document where exceptions to the
standard are claimed. Load calculations per
acceptable engineering st
Plan Review C103.2 Mechanical Plans, specifications, and/or calculations provide
all information with which compliance can be
determined for the service water heating systems
and equipment and document where exceptions
to the standard are claimed. Hot water system
sized per manufact
Plan Review C103.2 Interior Lighting Plans, specifications, and/or calculations provide
all information with which compliance can be
determined for the interior lighting and electrical
systems and equipment and document where
exceptions to the standard are claimed.
Information provided shoul
Plan Review C103.2 Exterior Lighting Plans, specifications, and/or calculations provide
all information with which compliance can be
determined for the exterior lighting and electrical
systems and equipment and document where
exceptions to the standard are claimed.
Information provided shoul
Insulation C402.2.5 Envelope Slab edge insulation depth/length. Slab insulation
extending away from building is covered by
pavement or >= 10 inches of soil.
Insulation C402.2.6 Project Radiant heating systems panels insulated to
>=R-3.5 on face opposite space being heated.
HVAC C402.2.6 Mechanical Thermally ineffective panel surfaces of sensible
heating panels have insulation >= R-3.5.
Insulation C402.2.6 Envelope Radiant panels and associated components,
designed for heat transfer from the panel surfaces
to the occupants or indoor space are insulated
with a minimum of R-3.5.
Air Leakage C402.5.7 Envelope Vestibules are installed on all building entrances .
Doors have self-closing devices.
SYSTEM_SPECIFIC C403.2.12.3 Mechanical Fans have efficiency grade (FEG) >= 67. The total
efficiency of the fan at the design point of
operation <= 15% of maximum total efficiency of
the fan.
HVAC C403.2.13 Mechanical Unenclosed spaces that are heated use only
radiant heat.
HVAC C403.2.4.2 Mechanical Each zone equipped with setback controls using
automatic time clock or programmable control
system.
SYSTEM_SPECIFIC C403.2.4.4 Mechanical Zone isolation devices and controls installed
where applicable.
SYSTEM_SPECIFIC C403.2.4.7 Mechanical Fault detection and diagnostics installed with
air-cooled unitary DX units having economizers.
SYSTEM_SPECIFIC C403.2.5 Mechanical Hot water boilers supplying heat via one- or
two-pipe systems include outdoor setback control.
HVAC C403.2.6.1 Mechanical Demand control ventilation provided for spaces
>500 ft2 and >25 people/1000 ft2 occupant
density and served by systems with air side
economizer, auto modulating outside air damper
control, or design airflow >3,000 cfm.
SYSTEM_SPECIFIC C403.4.1.1 Mechanical Hydronic and multizone HVAC system controls
areVAV fans driven by mechanical or electrical
variable speed drive per Table C 403.4.1.1.
SYSTEM_SPECIFIC C403.4.1.3 Mechanical Reset static pressure setpoint for DDC controlled
VAV boxes reporting to central controller based on
the zones requiring the most pressure.
SYSTEM_SPECIFIC C403.4.2 Mechanical Temperature reset by representative building
loads in pumping systems for chiller and boiler
systems >500,000 Btu/h.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 9 of 20
SYSTEM_SPECIFIC C403.4.2.3.2.1 Mechanical Closed-circuit cooling tower within heat pump loop
have either automatic bypass valve or lower
leakage positive closure dampers. Open-circuit
tower within heat pump loop have automatic valve
to bypass all heat pump water flow around the
tower. Open- or cl
SYSTEM_SPECIFIC C403.4.2.4 Mechanical Hydronic systems greater than 500,000 Btu/h
designed for variable fluid flow.
SYSTEM_SPECIFIC C403.4.2.5 Mechanical System turndown requirement met through
multiple single-input boilers, one or more
modulating boilers, or a combination of
single-input and modulating boilers.
Boiler input between 1.0 MBtu/h and 5 MBtu/h
has 3:1 turndown ratio, boiler input between 5.0
SYSTEM_SPECIFIC C403.4.2.6 Mechanical Chilled water plants with multiple chillers have
capability to reduce flow automatically through the
chiller plant when a chiller is shut down.
Boiler plants with multiple boilers have the
capability to reduce flow automatically through the
boiler plant
SYSTEM_SPECIFIC C403.4.3,
C403.4.3.2
Mechanical Fan systems with motors >=7.5 hp associated
with heat rejection equipment to have capability to
operate at 2/3 of full-speed and auto speed
controls to control the leaving fluid temperature or
condensing temp/pressure of heat rejection
device.
SYSTEM_SPECIFIC C403.4.4.5 Mechanical Multiple zone HVAC systems have supply air
temperature reset controls.
SYSTEM_SPECIFIC C403.4.4.6 Mechanical Multiple zone VAV systems with DDC of individual
zone boxes have static pressure setpoint reset
controls.
SYSTEM_SPECIFIC C404.2.1 Mechanical Gas-fired water-heating equipment installed in
new buildings: where a singular piece of
water-heating equipment >= 1,000 kBtu/h serves
the entire building, thermal efficiency >= 90 Et.
Where multiple pieces of water-heating
equipment serve the building wi
SYSTEM_SPECIFIC C404.4 Mechanical All piping insulated in accordance with section
details and Table C403.2.10.
SYSTEM_SPECIFIC C404.5, C404.5.1,
C404.5.2
Mechanical Heated water supply piping conforms to pipe
length and volume requirements. Refer to section
details.
SYSTEM_SPECIFIC C404.6.3 Mechanical Pumps that circulate water between a heater and
storage tank have controls that limit operation
from startup to <= 5 minutes after end of heating
cycle.
SYSTEM_SPECIFIC C404.7 Mechanical Water distribution system that pumps water from
a heated-water supply pipe back to the
heated-water source through a cold-water supply
pipe is
a demand recirculation water system. Pumps
within this system have controls that start the
pump upon receiving
Wattage C405.5.1 Exterior Lighting Exterior lighting power is consistent with what is
shown on the approved lighting plans,
demonstrating proposed watts are less than or
equal to allowed watts.
Plan Review C405.6 Project Group R-2 dwelling units have separate electrical
meters.
Plan Review C406 Project Plans, specifications, and/or calculations provide
all information with which compliance can be
determined for the additional energy efficiency
package options.
SYSTEM_SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have
means to balance and have pressure test
connections.
SYSTEM_SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have
means to balance and have pressure test
connections.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 10 of 20
3. To be checked by Inspector
Insulation C303.1 Envelope Roof insulation installed per manufacturer’s
instructions. Blown or poured loose-fill insulation
is installed only where the roof slope is <=3 in 12.
Insulation C303.1 Envelope Building envelope insulation is labeled with
R-value or insulation certificate providing R-value
and other relevant data.
Fenestration C303.1.3 Envelope Fenestration products rated in accordance with
NFRC.
Fenestration C303.1.3 Envelope Fenestration products are certified as to
performance labels or certificates provided.
Insulation C303.2, C402.2.4 Envelope Floor insulation installed per manufacturer's
instructions. Cavity or structural slab insulation
installed in permanent contact with underside of
decking or structural slabs.
Insulation C303.2.1 Envelope Exterior insulation protected against damage,
sunlight, moisture, wind, landscaping and
equipment maintenance activities.
Insulation C303.2.1 Envelope Exterior insulation is protected from damage with
a protective material. Verification for exposed
foundation insulation may need to occur during
Foundation Inspection.
Insulation C402.1.3 Envelope Non-swinging opaque doors have R-4.75
insulation.
Insulation C402.2.2 Envelope Skylight curbs are insulated to the level of roofs
with insulation above deck or R-5.
Insulation C402.2.2 Envelope Insulation intended to meet the roof insulation
requirements cannot be installed on top of a
suspended ceiling. Mark this requirement
compliant if insulation is installed accordingly.
Air Leakage C402.5 Envelope Building envelope contains a continuous air
barrier that has been tested and deemed to limit
air leakage <= 0.40 cfm/ft2.
Air Leakage C402.5.1 Envelope The building envelope contains a continuous air
barrier that is sealed in an approved manner and
either constructed or tested in an approved
manner. Air barrier penetrations are sealed in an
approved manner.
Air Leakage C402.5.1.1 Envelope All sources of air leakage in the building thermal
envelope are sealed, caulked, gasketed, weather
stripped or wrapped with moisture
vapor-permeable wrapping material to minimize
air leakage.
Air Leakage C402.5.1.2.1 Envelope The building envelope contains a continuous air
barrier that is sealed in an approved manner and
material permeability <= 0.004 cfm/ft2. Air barrier
penetrations are sealed in an approved manner.
Air Leakage C402.5.1.2.2 Envelope The building envelope contains a continuous air
barrier that is sealed in an approved manner and
average assembly air leakage <= 0.04 cfm/ft2.
Air barrier penetrations are sealed in an approved
manner.
Air Leakage C402.5.2, C402.5.4 Envelope Factory-built fenestration and doors are labeled
as meeting air leakage requirements.
Air Leakage C402.5.3 Envelope Where open combustion air ducts provide
combustion air to open combustion fuel burning
appliances, the appliances and combustion air
opening are located outside the building thermal
envelope or enclosed in a room, isolated from
inside the thermal envelope
Air Leakage C402.5.5,
C403.2.4.3
Envelope Stair and elevator shaft vents have motorized
dampers that automatically close.
Air Leakage C402.5.5,
C403.2.4.3
Envelope Outdoor air and exhaust systems have motorized
dampers that automatically shut when not in use
and meet maximum leakage rates. Check gravity
dampers where allowed.
Air Leakage C402.5.6 Envelope Weatherseals installed on all loading dock cargo
doors.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 11 of 20
Air Leakage C402.5.8 Envelope Recessed luminaires in thermal envelope to limit
infiltration and be IC rated and labeled. Seal
between interior finish and luminaire housing.
HVAC C403.2.1 Mechanical HVAC systems and equipment design loads
calculated in accordance with
ANSI/ASHRAE/ACCA Standard 183 or by an
approved equivalent computational procedure
SYSTEM_SPECIFIC C403.2.10 Mechanical HVAC piping insulation thickness . Where piping
is installed in or under a slab, verification may
need to occur during Foundation Inspection.
HVAC C403.2.3 Mechanical HVAC equipment efficiency verified.
SYSTEM_SPECIFIC C403.2.3 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in.
labeled for replacement only as per Footnote b to
Table C403.2.3(3).
SYSTEM_SPECIFIC C403.2.4.1 Mechanical Heating and cooling to each zone is controlled by
a thermostat control. Minimum one humidity
control device per installed
humidification/dehumidification system.
SYSTEM_SPECIFIC C403.2.4.1.1 Mechanical Heat pump controls prevent supplemental electric
resistance heat from coming on when not needed.
HVAC C403.2.4.1.2 Mechanical Thermostatic controls have a 5 °F deadband.
HVAC C403.2.4.1.2 Mechanical Thermostatic controls have a 5 °F deadband.
HVAC C403.2.4.1.3 Mechanical Temperature controls have setpoint overlap
restrictions.
HVAC C403.2.4.2.1,
C403.2.4.2.2
Mechanical Automatic Controls: Setback to 55°F (heat) and
85°F (cool); 7-day clock, 2-hour occupant
override, 10-hour backup
SYSTEM_SPECIFIC C403.2.4.2.3 Mechanical Systems include optimum start controls.
HVAC C403.2.4.5,
C403.2.4.6
Mechanical Snow/ice melting system sensors for future
connection to controls. Freeze protection systems
have automatic controls installed.
HVAC C403.2.6.2 Mechanical Enclosed parking garage ventilation has
automatic contaminant detection and capacity to
stage or modulate fans to 50% or less of design
capacity.
HVAC C403.2.9 Mechanical HVAC ducts and plenums insulated . Where ducts
or plenums are installed in or under a slab,
verification may need to occur during Foundation
Inspection.
SYSTEM_SPECIFIC C403.2.9.1.3 Mechanical Ductwork operating >3 in. water column requires
air leakage testing.
SYSTEM_SPECIFIC C403.4.1.2 Mechanical VAV fans have static pressure sensors located so
controller setpoint <=1.2 w.c..
SYSTEM_SPECIFIC C403.4.2.2 Mechanical Two-pipe hydronic systems using a common
distribution system have controls to allow a
deadband >=15ºF, allow operation in one mode
for at least 4 hrs before changeover, and have
rest controls to limit heating and cooling supply
temperature to <=30 ºF.
SYSTEM_SPECIFIC C403.4.2.3.3 Mechanical Two-position automatic valve interlocked to shut
off water flow when hydronic heat pump with
pumping system >10 hp is off.
SYSTEM_SPECIFIC C403.4.4.5,
C403.4.4.5.1-4
Mechanical Zone controls can limit simultaneous heating and
cooling and sequence heating and cooling to each
zone.
SYSTEM_SPECIFIC C403.4.5 Mechanical Condenser heat recovery system that can heat
water to 85ºF or provide 60% of peak heat
rejection is installed for preheating of service hot
water.
SYSTEM_SPECIFIC C403.4.6 Mechanical Hot gas bypass limited to:
<=240 kBtu/h - 50% capacity,
>240 kBtu/h - 25% capacity
SYSTEM_SPECIFIC C404.3 Mechanical Heat traps installed on non-circulating storage
water tanks.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 12 of 20
SYSTEM_SPECIFIC C404.3 Mechanical Heat traps installed on supply and discharge
piping of non-circulating systems.
SYSTEM_SPECIFIC C404.3 Mechanical Heat traps installed on supply and discharge
piping of non-circulating systems.
SYSTEM_SPECIFIC C404.6.1 Mechanical Controls are installed that limit the operation of a
recirculation pump installed to maintain
temperature of a storage tank. System return pipe
is a dedicated return pipe or a cold water supply
pipe.
SYSTEM_SPECIFIC C404.6.1, C404.6.2 Mechanical Automatic time switches installed to automatically
switch off the recirculating hot -water system or
heat trace.
SYSTEM_SPECIFIC C404.9.1 Mechanical Pool heaters are equipped with on/off switch and
no continuously burning pilot light.
SYSTEM_SPECIFIC C404.9.2 Mechanical Time switches are installed on all pool heaters
and pumps.
SYSTEM_SPECIFIC C404.9.2 Mechanical Time switches are installed on all pool heaters
and pumps.
SYSTEM_SPECIFIC C404.9.3 Mechanical Vapor retardant pool covers are provided for
heated pools and permanently installed spas.
Controls C405.2.1 Interior Lighting Lighting controls installed to uniformly reduce the
lighting load by at least 50%.
Controls C405.2.1 Interior Lighting Occupancy sensors installed in required spaces.
Controls C405.2.1,
C405.2.2.3
Interior Lighting Independent lighting controls installed per
approved lighting plans and all manual controls
readily accessible and visible to occupants.
Controls C405.2.2.1 Interior Lighting Automatic controls to shut off all building lighting
installed in all buildings.
Controls C405.2.3 Interior Lighting Daylight zones provided with individual controls
that control the lights independent of general area
lighting.
Controls C405.2.3,
C405.2.3.1,
C405.2.3.2
Interior Lighting Primary sidelighted areas are equipped with
required lighting controls.
Controls C405.2.3,
C405.2.3.1,
C405.2.3.3
Interior Lighting Enclosed spaces with daylight area under
skylights and rooftop monitors are equipped with
required lighting controls.
Controls C405.2.4 Interior Lighting Separate lighting control devices for specific uses
installed per approved lighting plans.
Wattage C405.2.4 Interior Lighting Additional interior lighting power allowed for
special functions per the approved lighting plans
and is automatically controlled and separated
from general lighting.
Controls C405.2.5 Exterior Lighting Automatic lighting controls for exterior lighting
installed. Controls will be daylight controlled, set
based on business operation time-of-day, or
reduce connected lighting > 30%.
Wattage C405.4.1 Interior Lighting Interior installed lamp and fixture lighting power is
consistent with what is shown on the approved
lighting plans, demonstrating proposed watts are
less than or equal to allowed watts.
Mandatory Additional Efficiency PackageC406.4 Project Enhanced digital lighting controls efficiency
package: Interior lighting has following enhanced
lighting controls in accordance with Section
C405.2.2:
Luminaires capable of continuous dimming and
being addressed individually, <= 8 luminaires
controlled in
Mandatory Additional Efficiency PackageC406.6 Project Dedicate outdoor air system efficiency package :
Buildings with hydronic and/or multiple-zone
HVAC systems are equipped with an independent
ventilation system designed to provide >=
100-percent outdoor air to each individual
occupied space, as specified by
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 13 of 20
Mandatory Additional Efficiency PackageC406.7, C406.7.1 Project Enhanced Service Water Heat System efficiency
package. One of the following SWH system
enhancements must satisfy 60 percent of hot
water requirements, or 100 percent if the building
otherwise complies with heat recovery per Section
C403.4.5: Waste heat re
HVAC C408.2.2.1 Mechanical Air outlets and zone terminal devices have means
for air balancing.
HVAC C408.2.2.1 Mechanical Air outlets and zone terminal devices have means
for air balancing.
Testing C408.2.3.2 Mechanical HVAC control systems have been tested to
ensure proper operation, calibration and
adjustment of controls.
4. To be checked by Inspector at Project Completion and Prior to Issuance of
Certificate of Occupancy
Post Construction C303.3, C408.2.5.2 Interior Lighting Furnished O&M instructions for systems and
equipment to the building owner or designated
representative.
Post Construction C303.3, C408.2.5.3 Mechanical Furnished O&M manuals for HVAC systems
within 90 days of system acceptance.
Fenestration C402.4.2.2 Envelope Skylights in office, storage, automotive service,
manufacturing, non-refrigerated warehouse, retail
store, and distribution/sorting area have a
measured haze value > 90 percent unless
designed to exclude direct sunlight.
Post Construction C408.2.1 Mechanical Commissioning plan developed by registered
design professional or approved agency.
Post Construction C408.2.3.1 Mechanical HVAC equipment has been tested to ensure
proper operation.
Post Construction C408.2.3.3 Mechanical Economizers have been tested to ensure proper
operation.
Post Construction C408.2.4 Mechanical Preliminary commissioning report completed and
certified by registered design professional or
approved agency.
Post Construction C408.2.5.1 Mechanical Furnished HVAC as-built drawings submitted
within 90 days of system acceptance.
Post Construction C408.2.5.1 Interior Lighting Furnished as-built drawings for electric power
systems within 90 days of system acceptance.
Post Construction C408.2.5.3 Mechanical An air and/or hydronic system balancing report is
provided for HVAC systems.
Post Construction C408.2.5.4 Mechanical Final commissioning report due to building owner
within 90 days of receipt of certificate of
occupancy.
Post Construction C408.3 Interior Lighting Lighting systems have been tested to ensure
proper calibration, adjustment, programming, and
operation.
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 14 of 20
Input Data Report
Renovation to existing buildingOffice
34945FL807 S Kings Hwy
California Clos - 807 S Kings HwyOfficesProject Title:
Project Information
Building Classification:Building Type:
Zip:State:
Owner:
Address:
Project Name:
1,990
None
1 GrossArea (SF):
Bldg. Rotation:
No.of Stories:
Type DescriptionAcronym
Zones
Area
[sf]
Multi Total Area
[sf]
No
Offices California Clos - 807 S
Kings Hwy
CONDITIONED 1990.0 1 1990.0 1
Width
[ft]
Depth
[ft]
Description
Spaces
Acronym Height
[ft]
No Mult Total
Area
[sf]
Total
Vol[cf]
Type
OfficesIn Zone:
California Clos - 807 S
Kings Hwy
39.80 50.00 16.00 Offices 1 1990.0 31840.0Exam/Treatment (Hospital) 1
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 15 of 20
Control TypePower
[W]
Type
Lighting
No.of
Ctrl pts
No Category No. of
Luminaires
Watts per
Luminaire
In Zone: Offices
In Space: Offices
1 LED 20 Security (continuous) 1Exit Sign 5 4
2 LED 760 Manual On/Off 11General Lighting 19 40
3 LED 144 Manual On/Off 3General Lighting 8 18
Orient
ation
No
Walls (Walls will be rotated clockwise by building rotation value)
Description Width
[ft]
H (Effec)
[ft]
Multi
plier
Area
[sf]
Cond-
uctance
[Btu/h.sf.F]
Dens.
[lb/cf]
Heat
Capacity
[Btu/sf.F]
R-Value
[h.sf.F/Btu]
Type
In Zone: Offices
1 68.00 16.00 1 1088.0 0.0490 1.189 8.85 20.4Hardie Board 2 x6
R-19 1/2" Drywall
SouthPr0Zo1Wa1
No UOrientation
Windows (Windows will be rotated clockwise by building rotation value)
Description
[Btu/hr sf F]
SHGCShaded Vis.Tra W
[ft]
H (Effec)
[ft]
Multi
plier [sf]
Total Area
OfficesIn Zone:
South WallIn Wall:
3 Pr0Zo1Wa8Wi1 South 1.0600 0.45 0.76 7.00 5.00 2 70.0No
4 Pr0Zo1Wa8Wi1 South 1.0600 0.45 0.76 6.00 8.00 1 48.0No
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 16 of 20
Doors
No Description Area
[sf]
Multi
plier
H (Effec)
[ft]
Width
[ft]
Shade?Cond.
[Btu/h.sf.F]
Dens.
[lb/cf]
Ht Cap.
[Btu/sf.
F]
R
[h.sf.F/
Btu]
Type
In Zone:
In Wall:
Roofs
No Description Width
[ft]
Tilt
[deg]
Area
[sf]
Multi
plier
H (Effec)
[ft]
Type Cond.
[Btu/h.Sf. F]
Dens.
[lb/cf]
Heat Cap
[Btu/sf. F]
R-Value
[h.sf.F/Btu
In Zone: Offices
1 Pr0Zo1Rf2 50.00 39.80 1 1990.0 0.00 0.0492 20.3 9.49 1.34 Mtl Bldg Roof/R-19
Batt
UType DescriptionNo
Skylights
SHGC
[Btu/hr sf F]
Vis.Trans W
[ft]
H (Effec)
[ft]
Area
[Sf]
Multi-
plier
Total Area
[Sf]
In Zone:
In Roof:
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 17 of 20
Floors
No Description Area
[sf]
Multi
plier
H (Effec)
[ft]
Width
[ft]
Type Cond.
[Btu/h.sf.F
Dens.
[lb/cf]
Heat Cap.
[Btu/sf. F]
R-Value
[h.sf.F/Btu
In Zone: Offices
1 Pr0Zo1Fl2 50.00 1990.0 1 39.80 1 ft. soil, concrete
floor, with Ceramic
Tile
0.4000 34.00 113.33 2.50
Systems
Split AC 1 ea. 5 ton Split AC Constant Volume Air Cooled
Split System < 65000 Btu/hr
Component Category Capacity Efficiency IPLV
1
No. Of Units
1 Cooling System 60000.00 14.00 12.90
2 Heating System 34000.00 1.00
3 Air Handling System -Supply 2000.00 0.60
Eff.Inst.NoSizeCategory Equipment IPLV
Plant
LossEfficiencyI/P Rt.Cap.UnitCapacityW-Heater Description
Water Heaters
1 Electric water heater 1 [Gal] 3 [kW] 0.9800 [Ef][Btu/h]
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 18 of 20
WattageArea/Len/NoCategory Description
[sf/ft/No][W]
Ext-Lighting
No. of
Lumin-
aires
Watts per
Lumin-
aire
Control
Type
Insulation
Thickness
[in]
Nomonal pipe
Diameter
[in]
Insulation
Conductivity
[ Btu-in/h.sf.F]
Operating
Temp
[F]
Type
Piping
Is
Runout?No
VLTSHGCGlass
Conductance
[Btu/h.sf.F]
No. of
Panes
Glass Type
Fenestration Used
Name
User Defined 1 1.0600 0.4500 0.7600 Storefront Glass
RValue
[h.sf.F/Btu]
Sp. Heat
[Btu/lb.F]
Density
[lb/cf]
Cond-
uctivity
[Btu/h.ft.F
Thick
[ft]DescriptionAcronymMat No
Materials Used
Only
R-Value
Used
187 Matl187 GYP OR PLAS
BOARD,1/2IN
0.0417 0.0920 50.00 0.2000 0.4533 No
265 Matl265 Soil, 1 ft 1.0000 0.5000 100.00 0.2000 2.0000 No
48 Matl48 6 in. Heavyweight concrete 0.5000 1.0000 140.00 0.2000 0.5000 No
23 Matl23 6 in. Insulation 0.5000 0.0250 5.70 0.2000 20.0000 No
94 Matl94 BUILT-UP ROOFING, 3/8IN 0.0313 0.0930 70.00 0.3500 0.3366 No
420 Matl420 0.875 in. Stucco 0.0729 0.4000 16.00 0.2000 0.1822 No
407 Matl407 R-19 Generic Insulation 0.4147 0.0218 0.30 0.2000 19.0000 No
245 Matl245 PLYWOOD, 5/8IN 0.0521 0.0660 34.00 0.2900 0.7894 No
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 19 of 20
Constructs Used
1056 Mtl Bldg Roof/R-19 Batt 0.05 1.34 9.49 20.3
No Name Conductance
[Btu/h.sf.F]
Heat Cap
[Btu/sf.F]
Density
[lb/cf]
RValue
[h.sf.F/Btu]
Layer Material
No.
Material Thickness
[ft]
Framing
Factor
No
Simple
Construct
No
Massless
Construct
1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.000
2 23 6 in. Insulation 0.5000 0.000
1057 1 ft. soil, concrete floor, with
Ceramic Tile
0.40 34.00 113.33 2.5
No Name Conductance
[Btu/h.sf.F]
Heat Cap
[Btu/sf.F]
Density
[lb/cf]
RValue
[h.sf.F/Btu]
Layer Material
No.
Material Thickness
[ft]
Framing
Factor
No
Simple
Construct
No
Massless
Construct
1 265 Soil, 1 ft 1.0000 0.000
2 48 6 in. Heavyweight concrete 0.5000 0.000
1061 Hardie Board 2 x6 R-19 1/2"
Drywall
0.05 1.19 8.85 20.4
No Name Conductance
[Btu/h.sf.F]
Heat Cap
[Btu/sf.F]
Density
[lb/cf]
RValue
[h.sf.F/Btu]
Layer Material
No.
Material Thickness
[ft]
Framing
Factor
No
Simple
Construct
No
Massless
Construct
1 420 0.875 in. Stucco 0.0729 0.000
2 245 PLYWOOD, 5/8IN 0.0521 0.000
3 407 R-19 Generic Insulation 0.4147 0.000
4 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.000
EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017
Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option
7/14/2020 Page 20 of 20
2020-Jul-14 14:08:32
Rig ht-Su ite® U niv er sal 20 19 19 .0.20 RSU2 8254 Page 1
...California Clos - 807 S Kings Hwy 7.14.2020.rup Calc = MN5 Front Door faces: E
California Clos - 807 S Ki...Job:Right -Suite® Unive rsal 2019 Load Summary Jul 13, 2020Date:Offices E-Calcs Plus, Inc.By:
E-Calcs Plus, Inc.
9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810
Project Information
California Clos - 807 S Kings Hwy, Sansone LLCFor:
807 S Kings Hwy, Fort Pierce, FL 34945
COOLING LOADOfficesZone:
Peak load at Aug 1700 LDTat Aug 1700 LDT1. DESIGN CONDITIONS
Inside:°F75 Outside:°F90 TD:°F15
RH:58 %MoistDiff:gr/lb59.4 Mult:1.0 Ins.wb °F63
Sensible Latent
16102. SOLAR RADIATION THROUGH GLASS -
3. TRANSMISSION GAINS Sensible 10346 -
Walls:5035 --
Glass:1464 --
Doors:530 --
Partitions:0 --
Floors:0 --
Ceilings:3316 --
4. INTERNAL HEAT GAIN Sensible Latent 400012603
Occupants:40004750 --
Lights:3361 ---
Motors:0 ---
Appliances:04493 --
5. INFILTRATION:42Outside air cfm:694 1694
6. SUBTOTAL:Space load Sensible Latent 569425253
Envelope 569425253 --
Less external 0 ---
Redistribution 00 --
60807. SUPPLY DUCT -
8. SUBTOTAL:Space load + supply duct 31334 -
1867Actual cfm:at supply TD:20 --
Make-up air cfm:9. VENTILATION:3615219 8823
10. RETURN AIR LOAD:Lighting + plenum (net)0 -
290311. RETURN DUCT -
167963820812. TOTAL LOADS ON EQUIPMENT
HEATING LOAD
13. DESIGN CONDITIONS Mult:1.0
Inside:°F70 Outside:°F43 TD:°F27
14. TRANSMISSION LOSSES 15715
Walls:6340 -
Glass:2889 -
Doors:505 -
Partitions:0 -
Floors:4269 -
Ceilings:1711 -
15. INFILTRATION:5009169Outside air cfm:
16. SUBTOTAL:Space load 20723
Envelope 20723 -
Less external 0 -
Less transfer 0 -
Redistribution 0 -
17. SUPPLY DUCT:5169
18. VENTILATION:6491219Make-up air cfm:
19. HUMIDIFICATION 4690
Piping 0
20. RETURN DUCT 905
21. TOTAL HEATING LOAD ON EQUIPMENT 37979
2020-Jul-14 14:08:33
Rig ht-Su ite® U niv er sal 20 19 19 .0.20 RSU2 8254 Page 1
...California Clos - 807 S Kings Hwy 7.14.2020.rup Calc = MN5 Front Door faces: E
California Clos - 807 S Ki...Job:Righ t-Suite® Univ er sal 20 19 Sh or t F or m Jul 13, 2020Date:Offices E-Calcs Plus, Inc.By:
E-Calcs Plus, Inc.
9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810
Project Information
California Clos - 807 S Kings Hwy, Sansone LLCFor:
807 S Kings Hwy, Fort Pierce, FL 34945
Htg Clg Htg Clg
Outside db 9043(°F)Inside db 7570(°F)
Outside RH 58-(%)Inside RH 50-(%)
Outside wb 78-(°F)Inside wb 63-(°F)
Daily range 15-(°F)Design TD 1527(°F)
Moisture diff.59-(gr/lb)
Cooling EquipmentHeating Equipment
Make York Make York
Model Model YCE60B21
Type Elec strip Type Split AC
Efficiency 100 EFF COP / EER / SEER 14.0
Heating Input kW10.0 Sensible Cooling MBtuh39.2
Heating Output MBtuh34.1 Latent Cooling MBtuh16.8
Humidifier gpd12.4 Total Cooling MBtuh56.0
Leaving Air Temp °F86.6 Leaving Air Temp °F55.0
Actual Heating Fan cfm1867 Actual Cooling Fan cfm1867
Equipment Location Offices
System Type PROPCV
Fan Motor Heat Type BLOWTHRU
Fan & Motor Combined Efficiency %80.0
Static Pressure Across Fan in H2O0.5
NAME Area Heat Sensible Latent Htg Clg Time
ft²Loss Gain Gain cfm cfm
Install Man 220 Aug 1700 LDT247392245249567323
Recycling 132 Aug 1700 LDT12014687324032822
BA 72 Aug 1700 LDT57266591204756
BA 2 48 Aug 1700 LDT4417573939573
Break Room 112 Aug 1700 LDT794080216471059
Scheduling 160 Aug 1700 LDT139108137528952362
Production 150 Aug 1700 LDT250363188349476516
Manager 120 Aug 1700 LDT17721287334763776
Production 2 90 Aug 1700 LDT779772315921978
Admin 94 Aug 1700 LDT9614798019542818
Hall 782 Aug 1700 LDT5853195603121957995
Offices 1980 37979 38208 16796 1867 1867 Aug 1700 LDT
Job #: California Clos - 807 S Kings Hwy
Performed by E-Calcs Plus, Inc. for:
California Clos - 807 S Kings Hwy
807 S Kings Hwy
Fort Pierce, FL 34945
E-Calcs Plus, Inc.
9250 Corkscrew Rd, Suite 8
Estero, FL 33928
Phone: 239.810.6106
www.ecalcsplus.com eric@ecalcsplus.com
Scale: 1 : 211
Page 1
Ri ght-Sui te ® Uni versal 201 9
19.0.20 RSU28254
2020-Jul-14 14:08:58
... - 807 S Kings Hwy 7.14.2020.rup
N
First Floor
Install Man
Recycling
BABA 2Break RoomScheduling
Production Manager Production 2 Admin
Hall
Warehouse