FL # FL17022-R7
Application Type Revision
Code Version 20-17
Application Status Approved
Comments 08118/2017v. date reapply 08/21/17
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phane/Emaff 2160 SW Poma Drive
Palm City, FL, 34990
(772) 872-8034
fivalidabon@yahoo.com
Authorized Signature Richard McKuhen
fivalidation0yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 8-i2-8034
richardC&emfab.net
Quality Assurance Represenbative,
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report. - Hardcopy Received
Florida Engineer or Architect Name who de,.meloped the LOCKE BOWDEN
Evaluation Report
Florida License PE -49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
"I Validation Cheddist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pd
gtgndard
TAS, 125
UL 1897
UL 580
Year
2003
2012
2006
https://www.floridabuHding.orgipr/pr_app jM-aspx?param---viGEVXQwtDqv2aBQpHpQQe6rMZMkUE-oR%2bGxHGxFe5QkGHzEqvOQveeg%3d%3d 1/3
21222019
C rwrk� = T
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
0811012017
0812512017
08,/28/2017
10/10/2017
FL Model, Number or Name
Description
17022-1 1 - "5V Crimp" (P,6) Z6 Gauge steel, 318" rib height, ZV wide lapped roof panel
mechanically attached to. 15132" plywood or Wood Deck with
fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ. No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.p -dL
f
Approved for use outside HVHZ: Yes
Verified By. Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure. +N/A/ -Table A Evaluation Reports
Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.pd
assembly in compliance with the installation method listed in Created by Independent Third Party. Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
-- -- ------------------- ------------ -----
17022,2 2 - "5V Crimp" (R6)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ. yes
Impact Resistant. No
Design Pressure. +N/A/ -Table A
Other: Refer to evaluation report for conditions. I nsta It the
assembly in compliance with the instaflaticia me -had, tistedr in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
3 - "1.5" Mechanical Seam" (RS)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ-. Yes
Impact Resistant- No
Design Pressure. +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.4 14 - "1.5' Mechanical Seam" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ. Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
0.03Z" Aluminum, 3/8* Rib height, 21' wide lapped roof panel
mechanically attached to 15/327 plywood or Wood Deck with
exposed fasteners
Installation Instructions
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssl.-pjlf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pAf
Created by IndependentThird. Party- Yes
1.5' rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32' plywood or wood deck
with clips and fasteners.
Installation Instructions
FL17022 R7 11 FL 17022.3 1.5 MECHANICAL
,seam 24ga ssr.P.!i-f
Verified By., Locke Bowden, RE. 49704
Created by Independent Third Party: yes
Evaluation Reports
FL17022 R7 AE FL 170223 1.5 MECHANICAL
seam 24ga ssr.pd
Created by Independent Third Party: Yes
1.5" rib height, IV wide, 0.032' aluminum, standing seam roof
panel mechanically attached to 15/32" plywood or Wood Deck
with clips and fasteners.
Installation Instructions
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
�ALUMINUM ssr.pLif
Verified By: Locke Bowden, l} E. 49704
Created by Independent Third Party: Yes
Evaluation Reporm
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
.ALUMINUM ssnpff
Created by Independent Third Party: Yes
17022.5 p 5 - "I in. Nail Strip" (RS) I" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attactied to 1,5132" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ. No FL17022 R7 11 FL 17022.5 1.0 NAILSTRIP ssr. f
Approved for use outside HVHZ-. Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/Al-Table A
Evaluation Reports
Other. Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.p f
of use. Install the assembly in compliance with the installation Created by Independent Third Party- Yes
https://www.floridabuilding.org/prlpr_app_�M.aspx?param--mGEVXQwtDqv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEqvooveeg%3d�/�3d 213
2/22[2019 Florida Building Code Online
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
117022.6 6 - "l in. Nail Strip' (RS) rib height, 16" wide, 0.032!' aluminum, standing seam roof
net mechanically attached to attached to 15132' plywood or
Wood Deck fasteners,
with
Limits of Use
j Installation Instructions
Approved for use in HVHZ-- No
Approved for use outside HVH7-- Yes
FL17022 R7 H FL 17022.6 1.0 NAIL STRIP 0,032
ALUM ssr.pdf
Impact Resistant: No
Verified By: Locke Bowden, P. Eo 49704
Design Pressure: +N/A/-Tabie A
1 Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and limitations :1 Evalluation Reports
of use. Install the assembly in compliance with the installation
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
method listed in this report and applicable code sections of
ALUM ssr.pd
FBC. Refer to manufacturer's installation instructions.
-- - — — -- ------------
iCreated by Independent Third Party- Yes
17022.7 17 - "1.5 in. Nail Strip" (RS)
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15132" plywood or wood deck
with fasteners.
limits of Use
j Installation Instructions
Approved for use in HVHZ. No
Approved for use outside HVHZ- Yes
FL17022 R7 11 FL 13022.7 —Nail Strip 26GA Ssr.Ddf
Verified By. Locke Bowden, t? E. 49704
Impact Resistant. No
Design Pressure- +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and limitations
Evaluation Reports
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdrf
of use. Install the assembly in compliance with the installation
Created by Independent Third Party: Yes
i method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
- — ----------------------
17022.8 18 - -EMAX Rib- (RS)
29 gauge steel, tapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Approved for use in HVHZ. No
I Installation Instructions
Approved for use outside HVHZ- Yes
FL17022 R7 II FL 177022.8 EMAX Rib ssrpd
Impact Resistant- No
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
Evaluation Reports
FL17022
of use. Install the assembly in compliance with the installation
R7 AE FL 177022.8 EMALRlt _Ssr. df
j Created by Independent Third Party: Yes
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.9 19 - PBR MAX" (115)
26 gauge steel, tapped roof panel mechanically attached to
— --- — -----------------
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ. No
FL17022 R7 II FL 17022.9 PBR RIB ssr.p f
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant, No
Design
Created by Independent Third Party: Yes
Pressure. +N/Al-Table A
1 Evaluation Reports
Other: Refer to evaluation report for conditions and limitations
FL17022 R7 AE FL 17022.9 PBR RIB
of use. Install the assembly in compliance with the installation
--ssrj)df
Created by Independent Third Party. Yes
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
I
Contact Us :: 2601 Blair Stone Road _Tapia hgKeeLL 2399 fl!jqqij: aS0,-4a7-MZ4
The State of Florida is an AMEEG empleirer.
Lt,slk etas St map.�,rt .. ragrlind Sgateanent
Under Florida law, email addresses are public records. If YOU do net want your e-mail address released in response to a reques,,. do not send electronic
mail to this entity. instead, contact the office by phone or by traditional mad. 11 you have arry questions, Please corlZact- 850.487.1345. -Pursuaot to Section 455.275(1),
Florida Statutes, effective October 1, 2014 licensees licensed under ChapW 455, F S. must provide the Department with an email address if they have one. Tice emails
provided may be used for official communication with the licensee- However email addresses are public recriviL If YOU do net wish to supply a personak address, please
provide the Department with an email address Which can be made available to the public. To determine if you are a. licensee under Chapter 455, F.S, please click —here
product AppirwWall Acmpts:
7M NWW -11 W— 9 ick
MM
Credit Card
Safe
L
https:liwww.floridabudding.orglprlpr_app_Od-aspx?param--wGEVXQwtDqv2aBQpHpQQe6rMZMkUEoR"1.2bGxtiGxFe5QkCHzEqvoQveeg%3d%3d 3/3
t SW Poma Drive{{
Palm City,_FL
Compliant with Ff s • •;•';' •
Compliant:
Product:
Yield ! - • to r plywood s
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
• Height 1"
Corrosion Resistant • •liant: FBC Sec. 1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of #•
Adhesive/Sealant• one s ponent, polyurethane adhesive
3/16" continuous bead application along base of male rib vertical flange at each panel
s To be • s f
Install Details: Table A Allowable loads
METHOD 1 __T-07.25
M®D 2
DESIGN PRESSURE*
-86 PSF Main field
PSF Feri meter
FASTENER SPACING
6" O.C.�
6" O.C.
SEAM ADHESIVE
Not required
_
_ 3/16" continuous bead
(see details)
rcegerence Date ARCHITECTURAL TESTING, INC. TST I 1527
UL 580-06 & UL 1807-04 TEST REPORT D81.01-450-18 /30/15 Specimen #1 & #2
EQUIVALENCY: UL1897-04 is equivalent to Test Standard Li z 12. *Pe srn sq,r e _,�1� e�f safety 2.-Z ►
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acq lre a financial Sf tt Y company manufacturing or distributing products
under this evaluation. A� 8t"? ),
Locke Bowden, P.E. is not owned, operated, or controllp �g, • ' , � ,
report. �� , YV�T� p� Ihany%cturer, or distributing P under this
° seal
STATE OF
6�}ib#��
NAL.
Limitations:
1. Inderlayment to be corrobnce with current Florida Building Code (FBC)2017 6th ed..
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference.
3. Products am compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: I -D
4. Enqjneerinq anaWs for "Druiect %,tw.4TC annroval h'vII'*.j 91 �ftwffiw w/h 14QJjr+,&,j ic rij&,nr
Lel j 0 1 ril
Ib tor
Structural
Loading.
7. This report does not imply warranty, irstaltation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
16"
Panel Profile
16" O.G-
j
3/4'r
i
Deck:
- 15/32" or greater Plywood, or
- Wood plank
For METHOD 2:
Apply 3116" Bead Bostik 915TIO Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 x I" Min. per Table "N'
Pancake Head Wood Screw
1"
FL 17022®5
F.4qtpnpr
I -or meulod 2
15,32"or greater Plywood, or Apply WIV Bead Bostik 915Tm Sealant
Wood plank Continuous Along Mate Rib Vertical Flange
(Refer to Table "A")