Loading...
HomeMy WebLinkAboutEngineering, letter from architectArchitectonic Inc St. Lucie County Building Department St. Lucie County, FL July 22, 2020 RE: 5560 South US Hwy 1 Garage Door Replacement To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed garage door is in compliance with the 2017 Florida Building Code, 165 mph wind zone, exposure "C", risk category II. From Table 1609.3.1: V„it= 165mph From Table 1609.7(1): 14'h x 12'w door, 165 mph = +21.8 / -24.2 From Table 1609.7(2): 30' mean roof height, Exposure C =1.40 Required Design Pressures: +21.8 x 1.40 = 30.5 -24.2 x 1.40 = -33.8 Product: Janus International Group, LLC, Series 3100 — 26 Gauge Door Assembly FL# 12765.3 Product Pressures: +36 & -41.0 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1